Review After Configuration

Picture and Explaining


NE attributes

Notice: The default NE ID is 3,or 4. when commissioning links, We must modify NE ID as designed.But no need modify Ext
different sites with unique NE ID.

1+1 Protection

l 2.IF 1+1 protection configuration


Notice: If there is 1+1 link, before configing services we should create a protection group fitst. Usually, we use slot5&7 is a rotec
protection group. We also set slot 5(6) as working board and slot 7(8) as protection board.
After commissioning the link, we should make sure the" Switching Status of Device" is "Normal", not "Forced". So it c
working board to protection board if anything happen.

NE Time Synchronization

Notice: When commissioning links, we usually select "NM" as Synchronous Mode. It means NE time will be isochronous with N
laptop which we used for configurature. When NMS system installed in OMC, all NEs should synchronize with this system.

NE Clock Setting
Notice: Create an external clock source. First priority source must be on the top. There is a rule : all Nes should trace BSC cloc

IF Radio Work Mode

Notice: Set modulation as required in design file. If there is 1+1 link and you already config protection group, then only set "R
board, the other board will be automatically change work mode as same as working board.

ODU Frequency Attributes

Notice: Set Transmit Frequency as same as design doc.T/R data is "0" means it'll recognise T/R spacing from ODU hardware p
cinfig T/R Spacing.
Power Attributes

l 3.Equipment information

l 4.Advanced attributes

Notice: Set the tranmission power according design. Query "Actual Receive Power" to inspect quality of link.

Advanced Attributes

Notice: Query "Actual Transmission Status" of ODUs, working ODU should be unmute, and Protection ODU shoud be mute.(

Service Configuration
Notice: According design there should be services configured.

NE Performance Monitor

Notice: First click the item and check the Monitor time is started or not. Before start monitoring, ensure NE already synchron
function will be failed.

ECC Management
Notice: Each NE should be configured as "Auto mode".