Sunteți pe pagina 1din 18

/dev/hd4 1.50 0.94 0.

56 63% /
/dev/hd2 6.94 4.18 2.76 61% /usr
/dev/hd9var 4.12 2.21 1.92 54% /var
/dev/hd3 9.19 1.38 7.81 16% /tmp
/dev/hd1 4.56 2.27 2.29 50% /home
/proc - - - - /proc
/dev/hd10opt 2.06 1.05 1.01 52% /opt
/dev/usr-sapint 2.00 1.75 0.25 88% /usr/sapint/sap_bi_orig
/dev/EPP_lv 24.00 5.90 18.10 25% /oracle/BWQ
/dev/sapmntEPP_lv 5.00 1.88 3.12 38% /sapmnt/BWQ
/dev/usrsapEPP_lv 35.00 29.29 5.71 84% /usr/sap/BWQ
/dev/sapdata1EPP_lv 60.00 41.69 18.31 70% /oracle/BWQ/sapdata1
/dev/sapdata2EPP_lv 60.00 37.26 22.74 63% /oracle/BWQ/sapdata2
/dev/sapdata3EPP_lv 60.00 41.04 18.96 69% /oracle/BWQ/sapdata3
/dev/sapdata4EPP_lv 60.00 29.76 30.24 50% /oracle/BWQ/sapdata4
/dev/920_64EPP_lv 4.50 3.87 0.63 87% /oracle/BWQ/920_64
/dev/sapreorgEPP_lv 2.00 0.10 1.90 6% /oracle/BWQ/sapreorg
/dev/saparchEPP_lv 6.00 0.04 5.96 1% /oracle/BWQ/saparch
/dev/sapdata5EPP_lv 60.00 47.96 12.04 80% /oracle/BWQ/sapdata5
/dev/sapdata6EPP_lv 60.00 50.33 9.67 84% /oracle/BWQ/sapdata6
/dev/sapdata7EPP_lv 70.00 46.12 23.88 66% /oracle/BWQ/sapdata7
/dev/fslv00 30.00 16.02 13.98 54% /REFRESH
/dev/stage_lv 14.00 6.23 7.77 45% /oracle/stage
/dev/usr-users 0.50 0.05 0.45 10% /usr/users
/dev/dwhfin 1.00 0.75 0.25 75% /usr/sap/dwhfin
/dev/usrsap-edi 1.00 0.00 1.00 1% /usr/sap/edi
/dev/decunix 5.00 0.15 4.85 3% /usr/decunix
/dev/origlogBEPP_lv 0.50 0.22 0.28 45% /oracle/BWQ/origlogB
/dev/mirrlogAEPP_lv 0.50 0.20 0.30 40% /oracle/BWQ/mirrlogA
/dev/mirrlogBEPP_lv 0.50 0.20 0.30 40% /oracle/BWQ/mirrlogB
/dev/oraarchEPP_lv 20.00 2.60 17.40 14% /oracle/BWQ/oraarch
/dev/origlogAEPP_lv 0.50 0.22 0.28 45% /oracle/BWQ/origlogA
merry:/usr/sap/trans 25.50 17.28 8.22 68% /usr/sap/trans
merry:/staging 87.00 36.51 50.49 42% /staging

prtconf

System Model: IBM,8204-E8A


Machine Serial Number: 10FCB51
Processor Type: PowerPC_POWER6
Processor Implementation Mode: POWER 6
Processor Version: PV_6_Compat
Number Of Processors: 2
Processor Clock Speed: 4204 MHz
CPU Type: 64-bit
Kernel Type: 64-bit
LPAR Info: 12 npbsapBWQ-GIMLI
Memory Size: 11264 MB
Good Memory Size: 11264 MB
Platform Firmware level: EL340_116
Firmware Version: IBM,EL340_116
Console Login: enable
Auto Restart: true
Full Core: false
Network Information
Host Name: gimli
IP Address: 10.231.23.206
Sub Netmask: 255.255.255.0
Gateway: 10.231.23.1
Name Server: 10.1.2.10
Domain Name: la.mindspeed.com
Paging Space Information
Total Paging Space: 30720MB
Percent Used: 3%
Volume Groups Information
==============================================================================
rootvg:
PV_NAME PV STATE TOTAL PPs FREE PPs FREE DISTRIBUTION
hdisk1 active 639 22 19..00..00..00..03
hdisk2 active 639 22 19..00..00..00..03
==============================================================================
gimli_EPP:
PV_NAME PV STATE TOTAL PPs FREE PPs FREE DISTRIBUTION
hdisk4 active 798 0 00..00..00..00..00
hdisk5 active 798 0 00..00..00..00..00
hdisk6 active 798 0 00..00..00..00..00
hdisk7 active 798 0 00..00..00..00..00
hdisk8 active 798 147 00..00..00..00..147
hdisk9 active 798 0 00..00..00..00..00
hdisk10 active 798 0 00..00..00..00..00
hdisk11 active 798 0 00..00..00..00..00
hdisk16 active 798 0 00..00..00..00..00
hdisk17 active 798 76 00..00..00..00..76
hdisk18 active 798 256 00..00..00..96..160
hdisk19 active 798 0 00..00..00..00..00
==============================================================================
gimli:
PV_NAME PV STATE TOTAL PPs FREE PPs FREE DISTRIBUTION
hdisk3 active 199 64 01..00..00..23..40
==============================================================================
INSTALLED RESOURCE LIST
The following resources are installed on the machine.
+/- = Added or deleted from Resource List.
* = Diagnostic support not available.
Model Architecture: chrp
Model Implementation: Multiple Processor, PCI bus
+ sys0 System Object
+ sysplanar0 System Planar
* vio0 Virtual I/O Bus
* ent1 U8204.E8A.10FCB51-V12-C3-T1 Virtual I/O Ethern
et Adapter (l-lan)
* vscsi1 U8204.E8A.10FCB51-V12-C5-T1 Virtual SCSI Clien
t Adapter
* vscsi0 U8204.E8A.10FCB51-V12-C4-T1 Virtual SCSI Clien
t Adapter
* hdisk19 U8204.E8A.10FCB51-V12-C4-T1-L8f0000000000 Virtual SCSI Disk
Drive
* hdisk18 U8204.E8A.10FCB51-V12-C4-T1-L8e0000000000 Virtual SCSI Disk
Drive
* hdisk17 U8204.E8A.10FCB51-V12-C4-T1-L8b0000000000 Virtual SCSI Disk
Drive
* hdisk16 U8204.E8A.10FCB51-V12-C4-T1-L890000000000 Virtual SCSI Disk
Drive
* hdisk11 U8204.E8A.10FCB51-V12-C4-T1-L870000000000 Virtual SCSI Disk
Drive
* hdisk10 U8204.E8A.10FCB51-V12-C4-T1-L860000000000 Virtual SCSI Disk
Drive
* hdisk9 U8204.E8A.10FCB51-V12-C4-T1-L850000000000 Virtual SCSI Disk
Drive
* hdisk8 U8204.E8A.10FCB51-V12-C4-T1-L940000000000 Virtual SCSI Disk
Drive
* hdisk7 U8204.E8A.10FCB51-V12-C4-T1-L930000000000 Virtual SCSI Disk
Drive
* hdisk6 U8204.E8A.10FCB51-V12-C4-T1-L920000000000 Virtual SCSI Disk
Drive
* hdisk5 U8204.E8A.10FCB51-V12-C4-T1-L910000000000 Virtual SCSI Disk
Drive
* hdisk4 U8204.E8A.10FCB51-V12-C4-T1-L900000000000 Virtual SCSI Disk
Drive
* hdisk3 U8204.E8A.10FCB51-V12-C4-T1-L840000000000 Virtual SCSI Disk
Drive
* hdisk2 U8204.E8A.10FCB51-V12-C4-T1-L830000000000 Virtual SCSI Disk
Drive
* hdisk1 U8204.E8A.10FCB51-V12-C4-T1-L820000000000 Virtual SCSI Disk
Drive
* ent0 U8204.E8A.10FCB51-V12-C2-T1 Virtual I/O Ethern
et Adapter (l-lan)
* vsa0 U8204.E8A.10FCB51-V12-C0 LPAR Virtual Seria
l Adapter
* vty0 U8204.E8A.10FCB51-V12-C0-L0 Asynchronous Termi
nal
+ L2cache0 L2 Cache
+ mem0 Memory
+ proc0 Processor
+ proc2 Processor

netstat -nr

Routing tables
Destination Gateway Flags Refs Use If Exp Groups
Route Tree for Protocol Family 2 (Internet):
default 10.231.23.1 UG 5 19364916 en0 - -
10.231.23.0 10.231.23.206 UHSb 0 0 en0 - - =
>
10.231.23/24 10.231.23.206 U 3 2766319 en0 - -
10.231.23.206 127.0.0.1 UGHS 68 302594052 lo0 - -
10.231.23.255 10.231.23.206 UHSb 0 4 en0 - -
10.231.25.0 10.231.25.194 UHSb 0 0 en1 - - =
>
10.231.25/24 10.231.25.194 U 1 1382314487 en1 - -
10.231.25.194 127.0.0.1 UGHS 2 55 lo0 - -
10.231.25.255 10.231.25.194 UHSb 0 4 en1 - -
127/8 127.0.0.1 U 24 27087489 lo0 - -
Route Tree for Protocol Family 24 (Internet v6):
::1 ::1 UH 0 492 lo0 - -

ifconfig -a

en0: flags=1e080863,480<UP,BROADCAST,NOTRAILERS,RUNNING,SIMPLEX,MULTICAST,GROUPR
T,64BIT,CHECKSUM_OFFLOAD(ACTIVE),CHAIN>
inet 10.231.23.206 netmask 0xffffff00 broadcast 10.231.23.255
tcp_sendspace 262144 tcp_recvspace 262144 rfc1323 1
en1: flags=1e080863,480<UP,BROADCAST,NOTRAILERS,RUNNING,SIMPLEX,MULTICAST,GROUPR
T,64BIT,CHECKSUM_OFFLOAD(ACTIVE),CHAIN>
inet 10.231.25.194 netmask 0xffffff00 broadcast 10.231.25.255
tcp_sendspace 262144 tcp_recvspace 262144 rfc1323 1
lo0: flags=e08084b<UP,BROADCAST,LOOPBACK,RUNNING,SIMPLEX,MULTICAST,GROUPRT,64BIT
>
inet 127.0.0.1 netmask 0xff000000 broadcast 127.255.255.255
inet6 ::1/0
tcp_sendspace 131072 tcp_recvspace 131072 rfc1323 1

lsvg -p rootvg
rootvg:
PV_NAME PV STATE TOTAL PPs FREE PPs FREE DISTRIBUTION
hdisk1 active 639 22 19..00..00..00..03
hdisk2 active 639 22 19..00..00..00..03

lsvg
rootvg
gimli_EPP
gimli

lspv
hdisk1 000fcb517c4a9722 rootvg active
hdisk2 000fcb517c4a97a9 rootvg active
hdisk3 000fcb517c5a34da gimli active
hdisk4 000fcb517c7b1a48 gimli_EPP active
hdisk5 000fcb517c7b1a99 gimli_EPP active
hdisk6 000fcb517c7b1ae1 gimli_EPP active
hdisk7 000fcb517c7b1b38 gimli_EPP active
hdisk8 000fcb517c7b1b84 gimli_EPP active
hdisk9 000fcb517c7b1bd4 gimli_EPP active
hdisk10 000fcb517c7b1c3f gimli_EPP active
hdisk11 000fcb517c7b1cb9 gimli_EPP active
hdisk16 000fcb517c7b1d27 gimli_EPP active
hdisk17 000fcb517c7b1da4 gimli_EPP active
hdisk18 000fcb517c7b1e0c gimli_EPP active
hdisk19 000fcb517c7b1e77 gimli_EPP active

lscfg -pv | pg

INSTALLED RESOURCE LIST WITH VPD


The following resources are installed on your machine.
Model Architecture: chrp
Model Implementation: Multiple Processor, PCI bus
sys0 System Object
sysplanar0 System Planar
vio0 Virtual I/O Bus
ent1 U8204.E8A.10FCB51-V12-C3-T1 Virtual I/O Ethern
et Adapter (l-lan)
Network Address.............6E2393D98103
Displayable Message.........Virtual I/O Ethernet Adapter (l-lan)
Hardware Location Code......U8204.E8A.10FCB51-V12-C3-T1
vscsi1 U8204.E8A.10FCB51-V12-C5-T1 Virtual SCSI Clien
t Adapter
Hardware Location Code......U8204.E8A.10FCB51-V12-C5-T1
vscsi0 U8204.E8A.10FCB51-V12-C4-T1 Virtual SCSI Clien
t Adapter
Hardware Location Code......U8204.E8A.10FCB51-V12-C4-T1
hdisk19 U8204.E8A.10FCB51-V12-C4-T1-L8f0000000000 Virtual SCSI Disk
Drive
hdisk18 U8204.E8A.10FCB51-V12-C4-T1-L8e0000000000 Virtual SCSI Disk
Drive
hdisk17 U8204.E8A.10FCB51-V12-C4-T1-L8b0000000000 Virtual SCSI Disk
Drive
hdisk16 U8204.E8A.10FCB51-V12-C4-T1-L890000000000 Virtual SCSI Disk
Drive
hdisk11 U8204.E8A.10FCB51-V12-C4-T1-L870000000000 Virtual SCSI Disk
Drive
hdisk10 U8204.E8A.10FCB51-V12-C4-T1-L860000000000 Virtual SCSI Disk
Drive
hdisk9 U8204.E8A.10FCB51-V12-C4-T1-L850000000000 Virtual SCSI Disk
Drive
hdisk8 U8204.E8A.10FCB51-V12-C4-T1-L940000000000 Virtual SCSI Disk
Drive
hdisk7 U8204.E8A.10FCB51-V12-C4-T1-L930000000000 Virtual SCSI Disk
Drive
hdisk6 U8204.E8A.10FCB51-V12-C4-T1-L920000000000 Virtual SCSI Disk
Drive
hdisk5 U8204.E8A.10FCB51-V12-C4-T1-L910000000000 Virtual SCSI Disk
Drive
hdisk4 U8204.E8A.10FCB51-V12-C4-T1-L900000000000 Virtual SCSI Disk
Drive
hdisk3 U8204.E8A.10FCB51-V12-C4-T1-L840000000000 Virtual SCSI Disk
Drive
hdisk2 U8204.E8A.10FCB51-V12-C4-T1-L830000000000 Virtual SCSI Disk
Drive
hdisk1 U8204.E8A.10FCB51-V12-C4-T1-L820000000000 Virtual SCSI Disk
Drive
ent0 U8204.E8A.10FCB51-V12-C2-T1 Virtual I/O Ethern
et Adapter (l-lan)
Network Address.............6E2393D98102
Displayable Message.........Virtual I/O Ethernet Adapter (l-lan)
Hardware Location Code......U8204.E8A.10FCB51-V12-C2-T1
vsa0 U8204.E8A.10FCB51-V12-C0 LPAR Virtual Seria
l Adapter
Hardware Location Code......U8204.E8A.10FCB51-V12-C0
vty0 U8204.E8A.10FCB51-V12-C0-L0 Asynchronous Termi
nal
L2cache0 L2 Cache
mem0 Memory
proc0 Processor
proc2 Processor
PLATFORM SPECIFIC
Name: IBM,8204-E8A
Model: IBM,8204-E8A
Node: /
Device Type: chrp
System VPD:
Record Name.................VSYS
Flag Field..................XXSV
Brand.......................P0
Hardware Location Code......U8204.E8A.10FCB51
Machine/Cabinet Serial No...10FCB51
Machine Type and Model......8204-E8A
System Unique ID (SUID).....0004AC112A9A
World Wide Port Name........C05076004EB5
Version.....................ipzSeries
Physical Location: U8204.E8A.10FCB51
CEC:
Record Name.................VCEN
Flag Field..................XXEV
Brand.......................P0
Hardware Location Code......U78A0.001.DNWGH18
Machine/Cabinet Serial No...DNWGH18
Machine Type and Model......78A0-001
Controlling CEC ID..........8204-E8A 10FCB51
Rack Serial Number..........0000000000000000
Feature Code/Marketing ID...78A0-001
Version.....................ipzSeries
Physical Location: U78A0.001.DNWGH18
SYSTEM BACKPLANE:
Record Name.................VINI
Flag Field..................XXBP
Hardware Location Code......U78A0.001.DNWGH18-P1
Customer Card ID Number.....28A3
Serial Number...............YL12HA847017
CCIN Extender...............1
Product Specific.(VZ).......01
FRU Number..................07P6906
Part Number.................07P6907
Power.......................2A00000000000000
Product Specific.(HE).......0001
Product Specific.(CT).......40F30023
Product Specific.(HW).......0001
Product Specific.(B3).......000000000001
Product Specific.(B4).......00
Product Specific.(B7).......000000000000000000000000
Version.....................ipzSeries
Physical Location: U78A0.001.DNWGH18-P1
QUAD ETHERNET :
Record Name.................VINI
Flag Field..................XXET
Hardware Location Code......U78A0.001.DNWGH18-P1-C6
Customer Card ID Number.....1819
Serial Number...............YL13W806404M
CCIN Extender...............1
Product Specific.(VZ).......04
FRU Number..................10N9622
Part Number.................10N9623
Product Specific.(HE).......0001
Product Specific.(CT).......40910006
Product Specific.(HW).......0001
Product Specific.(B3).......000000000001
Product Specific.(B4).......00
Product Specific.(B7).......000000000000000000000000
Product Specific.(B1).......00145E52B0000020
Version.....................ipzSeries
Physical Location: U78A0.001.DNWGH18-P1-C6
ANCHOR :
Record Name.................VINI
Flag Field..................XXAV
Hardware Location Code......U78A0.001.DNWGH18-P1-C9
Customer Card ID Number.....52AE
Serial Number...............YL1107002176
CCIN Extender...............1
Product Specific.(VZ).......01
FRU Number..................10N8696
Part Number.................10N8696
Power.......................8100300000000000
Product Specific.(HE).......0010
Product Specific.(CT).......40B40000
Product Specific.(HW).......0001
Product Specific.(B3).......000000000001
Product Specific.(B4).......00
Product Specific.(B7).......000000000000000000000000
Product Specific.(B9).......43538127102533326B79535032905B01922F27A54D
31C384615247A8187A4D3235603803B957F9234D33
1D918AE516D6431D4D34322D7012BE0708FB
Version.....................ipzSeries
Physical Location: U78A0.001.DNWGH18-P1-C9
THERMAL PWR MGMT:
Record Name.................VINI
Flag Field..................XXTP
Hardware Location Code......U78A0.001.DNWGH18-P1-C12
Customer Card ID Number.....2A0E
Serial Number...............YL11W80580A6
CCIN Extender...............1
Product Specific.(VZ).......01
FRU Number..................10N9588
Part Number.................10N9588
Product Specific.(HE).......0001
Product Specific.(CT).......40B60003
Product Specific.(HW).......0001
Product Specific.(B3).......000000000001
Product Specific.(B4).......00
Product Specific.(B7).......000000000000000000000000
Version.....................ipzSeries
Physical Location: U78A0.001.DNWGH18-P1-C12
2 WAY PROC CUOD :
Record Name.................VINI
Flag Field..................XXPF
Hardware Location Code......U78A0.001.DNWGH18-P1-C13
Customer Card ID Number.....53E1
Serial Number...............YL1008000513
CCIN Extender...............1
Product Specific.(VZ).......03
FRU Number..................10N9725
Part Number.................46K6593
Power.......................3300200100028000
Product Specific.(HE).......0001
Product Specific.(CT).......40170102
Product Specific.(HW).......0001
Product Specific.(B3).......000000000001
Product Specific.(B4).......00
Product Specific.(B7).......000000000000000000000000
Product Specific.(B9).......43538038163253A00AA05350779F2B7760B3C7B94D
317C6AD8D7B35C88C24D325B9CEA81C57115F44D33
A0EF6585019377AC4D341BB87F2B74455FDA
Version.....................ipzSeries
Physical Location: U78A0.001.DNWGH18-P1-C13
Memory DIMM:
Record Name.................VINI
Flag Field..................XXMS
Hardware Location Code......U78A0.001.DNWGH18-P1-C13-C1
Customer Card ID Number.....31A6
Serial Number...............YLD0003B0E90
CCIN Extender...............1
Product Specific.(VZ).......01
FRU Number..................77P6500
Part Number.................77P6500
Power.......................4400000000000000
Size........................4096
Version.....................ipzSeries
Physical Location: U78A0.001.DNWGH18-P1-C13-C1
Memory DIMM:
Record Name.................VINI
Flag Field..................XXMS
Hardware Location Code......U78A0.001.DNWGH18-P1-C13-C2
Customer Card ID Number.....31A6
Serial Number...............YLD0043B0E88
CCIN Extender...............1
Product Specific.(VZ).......01
FRU Number..................77P6500
Part Number.................77P6500
Power.......................4400000000000000
Size........................4096
Version.....................ipzSeries
Physical Location: U78A0.001.DNWGH18-P1-C13-C2
Memory DIMM:
Record Name.................VINI
Flag Field..................XXMS
Hardware Location Code......U78A0.001.DNWGH18-P1-C13-C3
Customer Card ID Number.....31A6
Serial Number...............YLD0023B0E9D
CCIN Extender...............1
Product Specific.(VZ).......01
FRU Number..................77P6500
Part Number.................77P6500
Power.......................4400000000000000
Size........................4096
Version.....................ipzSeries
Physical Location: U78A0.001.DNWGH18-P1-C13-C3
Memory DIMM:
Record Name.................VINI
Flag Field..................XXMS
Hardware Location Code......U78A0.001.DNWGH18-P1-C13-C4
Customer Card ID Number.....31A6
Serial Number...............YLD0063B0EAD
CCIN Extender...............1
Product Specific.(VZ).......01
FRU Number..................77P6500
Part Number.................77P6500
Power.......................4400000000000000
Size........................4096
Version.....................ipzSeries
Physical Location: U78A0.001.DNWGH18-P1-C13-C4
Memory DIMM:
Record Name.................VINI
Flag Field..................XXMS
Hardware Location Code......U78A0.001.DNWGH18-P1-C13-C6
Customer Card ID Number.....31A6
Serial Number...............YLD001004083
CCIN Extender...............1
Product Specific.(VZ).......01
FRU Number..................77P6500
Part Number.................77P6500
Power.......................4400000000000000
Size........................4096
Version.....................ipzSeries
Physical Location: U78A0.001.DNWGH18-P1-C13-C6
Memory DIMM:
Record Name.................VINI
Flag Field..................XXMS
Hardware Location Code......U78A0.001.DNWGH18-P1-C13-C7
Customer Card ID Number.....31A6
Serial Number...............YLD005006044
CCIN Extender...............1
Product Specific.(VZ).......01
FRU Number..................77P6500
Part Number.................77P6500
Power.......................4400000000000000
Size........................4096
Version.....................ipzSeries
Physical Location: U78A0.001.DNWGH18-P1-C13-C7
Memory DIMM:
Record Name.................VINI
Flag Field..................XXMS
Hardware Location Code......U78A0.001.DNWGH18-P1-C13-C8
Customer Card ID Number.....31A6
Serial Number...............YLD003006093
CCIN Extender...............1
Product Specific.(VZ).......01
FRU Number..................77P6500
Part Number.................77P6500
Power.......................4400000000000000
Size........................4096
Version.....................ipzSeries
Physical Location: U78A0.001.DNWGH18-P1-C13-C8
Memory DIMM:
Record Name.................VINI
Flag Field..................XXMS
Hardware Location Code......U78A0.001.DNWGH18-P1-C13-C9
Customer Card ID Number.....31A6
Serial Number...............YLD007007070
CCIN Extender...............1
Product Specific.(VZ).......01
FRU Number..................77P6500
Part Number.................77P6500
Power.......................4400000000000000
Size........................4096
Version.....................ipzSeries
Physical Location: U78A0.001.DNWGH18-P1-C13-C9
2 WAY PROC CUOD :
Record Name.................VINI
Flag Field..................XXPF
Hardware Location Code......U78A0.001.DNWGH18-P1-C14
Customer Card ID Number.....53E1
Serial Number...............YL1008000565
CCIN Extender...............1
Product Specific.(VZ).......03
FRU Number..................10N9725
Part Number.................46K6593
Power.......................3300200100028000
Product Specific.(HE).......0001
Product Specific.(CT).......40170102
Product Specific.(HW).......0001
Product Specific.(B3).......000000000001
Product Specific.(B4).......00
Product Specific.(B7).......000000000000000000000000
Product Specific.(B9).......435380392032205657D753505CAF1FC4AC9D77634D
31C15B6107BBFFFEA64D3229B74E72B04441164D33
0A0A54EF5A7C671C4D3449A54AF4FF30E8A3
Version.....................ipzSeries
Physical Location: U78A0.001.DNWGH18-P1-C14
Memory DIMM:
Record Name.................VINI
Flag Field..................XXMS
Hardware Location Code......U78A0.001.DNWGH18-P1-C14-C1
Customer Card ID Number.....31A6
Serial Number...............YLD008522B0E
CCIN Extender...............1
Product Specific.(VZ).......01
FRU Number..................77P6500
Part Number.................77P6500
Power.......................4400000000000000
Size........................4096
Version.....................ipzSeries
Physical Location: U78A0.001.DNWGH18-P1-C14-C1
Memory DIMM:
Record Name.................VINI
Flag Field..................XXMS
Hardware Location Code......U78A0.001.DNWGH18-P1-C14-C2
Customer Card ID Number.....31A6
Serial Number...............YLD00C3ACC78
CCIN Extender...............1
Product Specific.(VZ).......01
FRU Number..................77P6500
Part Number.................77P6500
Power.......................4400000000000000
Size........................4096
Version.....................ipzSeries
Physical Location: U78A0.001.DNWGH18-P1-C14-C2
Memory DIMM:
Record Name.................VINI
Flag Field..................XXMS
Hardware Location Code......U78A0.001.DNWGH18-P1-C14-C3
Customer Card ID Number.....31A6
Serial Number...............YLD00A2277E8
CCIN Extender...............1
Product Specific.(VZ).......01
FRU Number..................77P6500
Part Number.................77P6500
Power.......................4400000000000000
Size........................4096
Version.....................ipzSeries
Physical Location: U78A0.001.DNWGH18-P1-C14-C3
Memory DIMM:
Record Name.................VINI
Flag Field..................XXMS
Hardware Location Code......U78A0.001.DNWGH18-P1-C14-C4
Customer Card ID Number.....31A6
Serial Number...............YLD00E3ACC9E
CCIN Extender...............1
Product Specific.(VZ).......01
FRU Number..................77P6500
Part Number.................77P6500
Power.......................4400000000000000
Size........................4096
Version.....................ipzSeries
Physical Location: U78A0.001.DNWGH18-P1-C14-C4
Memory DIMM:
Record Name.................VINI
Flag Field..................XXMS
Hardware Location Code......U78A0.001.DNWGH18-P1-C14-C6
Customer Card ID Number.....31A6
Serial Number...............YLD009732DB3
CCIN Extender...............1
Product Specific.(VZ).......01
FRU Number..................77P6500
Part Number.................77P6500
Power.......................4400000000000000
Size........................4096
Version.....................ipzSeries
Physical Location: U78A0.001.DNWGH18-P1-C14-C6
Memory DIMM:
Record Name.................VINI
Flag Field..................XXMS
Hardware Location Code......U78A0.001.DNWGH18-P1-C14-C7
Customer Card ID Number.....31A6
Serial Number...............YLD00D3AE360
CCIN Extender...............1
Product Specific.(VZ).......01
FRU Number..................77P6500
Part Number.................77P6500
Power.......................4400000000000000
Size........................4096
Version.....................ipzSeries
Physical Location: U78A0.001.DNWGH18-P1-C14-C7
Memory DIMM:
Record Name.................VINI
Flag Field..................XXMS
Hardware Location Code......U78A0.001.DNWGH18-P1-C14-C8
Customer Card ID Number.....31A6
Serial Number...............YLD00B2275F1
CCIN Extender...............1
Product Specific.(VZ).......01
FRU Number..................77P6500
Part Number.................77P6500
Power.......................4400000000000000
Size........................4096
Version.....................ipzSeries
Physical Location: U78A0.001.DNWGH18-P1-C14-C8
Memory DIMM:
Record Name.................VINI
Flag Field..................XXMS
Hardware Location Code......U78A0.001.DNWGH18-P1-C14-C9
Customer Card ID Number.....31A6
Serial Number...............YLD00F3AE3E3
CCIN Extender...............1
Product Specific.(VZ).......01
FRU Number..................77P6500
Part Number.................77P6500
Power.......................4400000000000000
Size........................4096
Version.....................ipzSeries
Physical Location: U78A0.001.DNWGH18-P1-C14-C9
2 WAY PROC CUOD :
Record Name.................VINI
Flag Field..................XXPF
Hardware Location Code......U78A0.001.DNWGH18-P1-C15
Customer Card ID Number.....53E1
Serial Number...............YL1110078000
CCIN Extender...............1
Product Specific.(VZ).......03
FRU Number..................10N9725
Part Number.................46K8039
Power.......................3300200100028000
Product Specific.(HE).......0001
Product Specific.(CT).......40170102
Product Specific.(HW).......0001
Product Specific.(B3).......000000000001
Product Specific.(B4).......00
Product Specific.(B7).......000000000000000000000000
Product Specific.(B9).......43530189214401937B60535027D7672738060B2F4D
3160F32E505FA368724D32B6CD2862F7D2645E4D33
05FFCABA8A9A34FC4D34B49AFEF4F52CE25D
Version.....................ipzSeries
Physical Location: U78A0.001.DNWGH18-P1-C15
Memory DIMM:
Record Name.................VINI
Flag Field..................XXMS
Hardware Location Code......U78A0.001.DNWGH18-P1-C15-C1
Customer Card ID Number.....31A6
Serial Number...............YLD0102275EF
CCIN Extender...............1
Product Specific.(VZ).......01
FRU Number..................77P6500
Part Number.................77P6500
Power.......................4400000000000000
Size........................4096
Version.....................ipzSeries
Physical Location: U78A0.001.DNWGH18-P1-C15-C1
Memory DIMM:
Record Name.................VINI
Flag Field..................XXMS
Hardware Location Code......U78A0.001.DNWGH18-P1-C15-C2
Customer Card ID Number.....31A6
Serial Number...............YLD0143B0F56
CCIN Extender...............1
Product Specific.(VZ).......01
FRU Number..................77P6500
Part Number.................77P6500
Power.......................4400000000000000
Size........................4096
Version.....................ipzSeries
Physical Location: U78A0.001.DNWGH18-P1-C15-C2
Memory DIMM:
Record Name.................VINI
Flag Field..................XXMS
Hardware Location Code......U78A0.001.DNWGH18-P1-C15-C3
Customer Card ID Number.....31A6
Serial Number...............YLD0122277E6
CCIN Extender...............1
Product Specific.(VZ).......01
FRU Number..................77P6500
Part Number.................77P6500
Power.......................4400000000000000
Size........................4096
Version.....................ipzSeries
Physical Location: U78A0.001.DNWGH18-P1-C15-C3
Memory DIMM:
Record Name.................VINI
Flag Field..................XXMS
Hardware Location Code......U78A0.001.DNWGH18-P1-C15-C4
Customer Card ID Number.....31A6
Serial Number...............YLD0163B0E93
CCIN Extender...............1
Product Specific.(VZ).......01
FRU Number..................77P6500
Part Number.................77P6500
Power.......................4400000000000000
Size........................4096
Version.....................ipzSeries
Physical Location: U78A0.001.DNWGH18-P1-C15-C4
Memory DIMM:
Record Name.................VINI
Flag Field..................XXMS
Hardware Location Code......U78A0.001.DNWGH18-P1-C15-C6
Customer Card ID Number.....31A6
Serial Number...............YLD011622B0F
CCIN Extender...............1
Product Specific.(VZ).......01
FRU Number..................77P6500
Part Number.................77P6500
Power.......................4400000000000000
Size........................4096
Version.....................ipzSeries
Physical Location: U78A0.001.DNWGH18-P1-C15-C6
Memory DIMM:
Record Name.................VINI
Flag Field..................XXMS
Hardware Location Code......U78A0.001.DNWGH18-P1-C15-C7
Customer Card ID Number.....31A6
Serial Number...............YLD0153B0F63
CCIN Extender...............1
Product Specific.(VZ).......01
FRU Number..................77P6500
Part Number.................77P6500
Power.......................4400000000000000
Size........................4096
Version.....................ipzSeries
Physical Location: U78A0.001.DNWGH18-P1-C15-C7
Memory DIMM:
Record Name.................VINI
Flag Field..................XXMS
Hardware Location Code......U78A0.001.DNWGH18-P1-C15-C8
Customer Card ID Number.....31A6
Serial Number...............YLD0136239AA
CCIN Extender...............1
Product Specific.(VZ).......01
FRU Number..................77P6500
Part Number.................77P6500
Power.......................4400000000000000
Size........................4096
Version.....................ipzSeries
Physical Location: U78A0.001.DNWGH18-P1-C15-C8
Memory DIMM:
Record Name.................VINI
Flag Field..................XXMS
Hardware Location Code......U78A0.001.DNWGH18-P1-C15-C9
Customer Card ID Number.....31A6
Serial Number...............YLD0173B0F00
CCIN Extender...............1
Product Specific.(VZ).......01
FRU Number..................77P6500
Part Number.................77P6500
Power.......................4400000000000000
Size........................4096
Version.....................ipzSeries
Physical Location: U78A0.001.DNWGH18-P1-C15-C9
CEC OP PANEL :
Record Name.................VINI
Flag Field..................XXOP
Hardware Location Code......U78A0.001.DNWGH18-D1
Customer Card ID Number.....296C
Serial Number...............YL10W806409A
CCIN Extender...............1
Product Specific.(VZ).......02
FRU Number..................44V4749
Part Number.................44V4747
Product Specific.(HE).......0001
Product Specific.(CT).......40B50000
Product Specific.(HW).......0001
Product Specific.(B3).......000000000000
Product Specific.(B4).......00
Product Specific.(B7).......000000000000000000000000
Version.....................ipzSeries
Physical Location: U78A0.001.DNWGH18-D1
Voltage Reg :
Record Name.................VINI
Flag Field..................XXRG
Hardware Location Code......U78A0.001.DNWGH18-P1-C13-C10
Customer Card ID Number.....2A29
FRU Number.................. 42R6492
Version.....................RS6K
Physical Location: U78A0.001.DNWGH18-P1-C13-C10
Voltage Reg :
Record Name.................VINI
Flag Field..................XXRG
Hardware Location Code......U78A0.001.DNWGH18-P1-C13-C5
Customer Card ID Number.....2A2C
FRU Number.................. 42R6498
Version.....................RS6K
Physical Location: U78A0.001.DNWGH18-P1-C13-C5
Voltage Reg :
Record Name.................VINI
Flag Field..................XXRG
Hardware Location Code......U78A0.001.DNWGH18-P1-C14-C10
Customer Card ID Number.....2A29
FRU Number.................. 42R6492
Version.....................RS6K
Physical Location: U78A0.001.DNWGH18-P1-C14-C10
Voltage Reg :
Record Name.................VINI
Flag Field..................XXRG
Hardware Location Code......U78A0.001.DNWGH18-P1-C14-C5
Customer Card ID Number.....2A2C
FRU Number.................. 42R6498
Version.....................RS6K
Physical Location: U78A0.001.DNWGH18-P1-C14-C5
Voltage Reg :
Record Name.................VINI
Flag Field..................XXRG
Hardware Location Code......U78A0.001.DNWGH18-P1-C15-C10
Customer Card ID Number.....2A29
FRU Number.................. 42R6492
Version.....................RS6K
Physical Location: U78A0.001.DNWGH18-P1-C15-C10
Voltage Reg :
Record Name.................VINI
Flag Field..................XXRG
Hardware Location Code......U78A0.001.DNWGH18-P1-C15-C5
Customer Card ID Number.....2A2C
FRU Number.................. 42R6498
Version.....................RS6K
Physical Location: U78A0.001.DNWGH18-P1-C15-C5
A IBM AC PS :
Record Name.................VINI
Flag Field..................XXPS
Hardware Location Code......U78A0.001.DNWGH18-E1
Customer Card ID Number.....51C3
Serial Number...............YL10HA837262
Part Number.................44V4951
FRU Number.................. 44V4951
Version.....................RS6K
Physical Location: U78A0.001.DNWGH18-E1
A IBM AC PS :
Record Name.................VINI
Flag Field..................XXPS
Hardware Location Code......U78A0.001.DNWGH18-E2
Customer Card ID Number.....51C3
Serial Number...............YL10HA7AL062
Part Number.................44V4951
FRU Number.................. 44V4951
Version.....................RS6K
Physical Location: U78A0.001.DNWGH18-E2
IBM Air Mover :
Record Name.................VINI
Flag Field..................XXAM
Hardware Location Code......U78A0.001.DNWGH18-A1
Customer Card ID Number.....27B8
FRU Number.................. 42R7657
Version.....................RS6K
Physical Location: U78A0.001.DNWGH18-A1
IBM Air Mover :
Record Name.................VINI
Flag Field..................XXAM
Hardware Location Code......U78A0.001.DNWGH18-A2
Customer Card ID Number.....27B8
FRU Number.................. 42R7657
Version.....................RS6K
Physical Location: U78A0.001.DNWGH18-A2
IBM Air Mover :
Record Name.................VINI
Flag Field..................XXAM
Hardware Location Code......U78A0.001.DNWGH18-A3
Customer Card ID Number.....27B8
FRU Number.................. 42R7657
Version.....................RS6K
Physical Location: U78A0.001.DNWGH18-A3
IBM Air Mover :
Record Name.................VINI
Flag Field..................XXAM
Hardware Location Code......U78A0.001.DNWGH18-A4
Customer Card ID Number.....27B8
FRU Number.................. 42R7657
Version.....................RS6K
Physical Location: U78A0.001.DNWGH18-A4
PSBPD6E4 3GSAS:
Record Name.................VINI
Flag Field..................XXDB
Hardware Location Code......U78A0.001.DNWGH18-P2
Customer Card ID Number.....2875
Serial Number...............YL1AW910508C
FRU Number.................. 46K6634
Part Number.................44V5561
CCIN Extender...............1
Product Specific.(VZ).......06
Product Specific.(B2).......5005076C0DA805000000000000000000
Version.....................RS6K
Physical Location: U78A0.001.DNWGH18-P2
System Firmware:
Code Level, LID Keyword.....Phyp_1 08392009112080A00701
Code Level, LID Keyword.....PFW 09112009102281CF0681
Code Level, LID Keyword.....FSP_Ker 16002010012681E00100
Code Level, LID Keyword.....FSP_Fil 16072010012681E00101
Code Level, LID Keyword.....FipS_BU 16072010012681E00200
Code Level, LID Keyword.....SPCN3 124620060531A0E00A11
Code Level, LID Keyword.....SPCN1 183020070213A0E00D00
Code Level, LID Keyword.....SPCN2 183420070213A0E00D20
Microcode Image.............EL340_116 EL340_075 EL340_116
Hardware Location Code......U8204.E8A.10FCB51-Y1
Physical Location: U8204.E8A.10FCB51-Y1
Name: openprom
Model: IBM,EL340_116
Node: openprom
Name: interrupt-controller
Model: IBM, Logical PowerPC-PIC, 00
Node: interrupt-controller@0
Device Type: PowerPC-External-Interrupt-Presentation
Name: vty
Node: vty@30000000
Device Type: serial
Physical Location: U8204.E8A.10FCB51-V12-C0
Name: l-lan
Node: l-lan@30000002
Device Type: network
Physical Location: U8204.E8A.10FCB51-V12-C2-T1
Name: l-lan
Node: l-lan@30000003
Device Type: network
Physical Location: U8204.E8A.10FCB51-V12-C3-T1
Name: v-scsi
Node: v-scsi@30000004
Device Type: vscsi
Physical Location: U8204.E8A.10FCB51-V12-C4-T1
Name: v-scsi
Node: v-scsi@30000005
Device Type: vscsi
Physical Location: U8204.E8A.10FCB51-V12-C5-T1