Sunteți pe pagina 1din 11

R&S® HE300 Diagrams

4 Diagrams
15

10
dB
5
ANTENNA MODULE
0 500 MHz to 7.5 GHz
ANTENNA MODULE
-5 20 MHz to 200 MHz

-10

-20

-25 ANTENNA MODULE


200 MHz to 500 MHz
-30

-35

-40 2 3 4
10 10 10 10
Frequency / MHz
Fig. 4-1: Gain, "Passive" mode.
20

15
dB
ANTENNA MODULE
10
20 MHz to 200 MHz
ANTENNA MODULE
5 500 MHz to 7.5 GHz

-5

-10

-15

-20
ANTENNA MODULE
200 MHz to 500 MHz
-25

-30
10 102 103 104
Frequency / MHz
Fig. 4-2: Gain, "Active" mode.

4067.5945.32-02.00 24
R&S® HE300 Diagrams

50

ANTENNA MODULE
45 500 MHz to 7.5 GHz

40

dB/m
ANTENNA MODULE
35 200 MHz to 500 MHz

30

25

20 ANTENNA MODULE
20 MHz to 200 MHz

15
2 3 4
10 10 10 10
Frequency / MHz

Fig. 4-3: Antenna factor, "Passive" mode.

40

ANTENNA MODULE
35 500 MHz to 7.5 GHz

dB/m

30

25
ANTENNA MODULE
200 MHz to 500 MHz

20

15

10
ANTENNA MODULE
20 MHz to 200 MHz
5
2 3 4
10 10 10 10
Frequency / MHz
Fig. 4-4: Antenna factor, "Active" mode.

4067.5945.32-02.00 25
R&S® HE300 Diagrams

S/N = 1, bandwidth 10 kHz, receiver noise figure 15 dB


40

ANTENNA MODULE
35 500 MHz to 7.5 GHz
dBuV/m
30

ANTENNA MODULE
25
200 MHz to 500 MHz

20

15

10
ANTENNA MODULE
5 20 MHz to 200 MHz

0
2 3 4
10 10 10 10
Frequency / MHz
Fig. 4-5: Sensitivity, "Passive" mode.

S/N = 1, bandwidth 10 kHz, receiver noise figure 15 dB


35
ANTENNA MODULE
30 500 MHz to 7.5 GHz
dBuV/m
25

20 ANTENNA MODULE
200 MHz to 500 MHz

15

10

ANTENNA MODULE
0 20 MHz to 200 MHz

-5
2 3 4
10 10 10 10
Frequency / MHz
Fig. 4-6: Sensitivity, "Active" mode.

4067.5945.32-02.00 26
R&S® HE300 Diagrams

45

Pegel / dB(V/m)
Level / dB(V/m)
40

35

30

25

20

15

10
10-1 100 101 102 103 104
Frequenz / MHz
Frequency / MHz

Fig. 4-7: Destructive field strength, "Active" mode (valid for all standard antenna modules).

4067.5945.32-02.00 27
R&S® HE300 Diagrams

Typical radiation patterns of the antenna module 20 MHz to 200 MHz

Patterns apply to normal handling position (handle upright)2

Horizontaldiagramm Vertikaldiagramm
Frequenz: 20 MHz Frequenz: 20 MHz

Horizontal pattern Vertical pattern


Frequency: 20 MHz Frequency: 20 MHz

1.0 0.8 0.6 0.4 0.2 0 1.0 0.8 0.6 0.4 0.2 0

Fig. 4-8: Radiation pattern, 20 MHz (antenna module 20 MHz to 200 MHz).

Horizontaldiagramm Vertikaldiagramm
Frequenz: 200 MHz Frequenz: 200 MHz

Horizontal pattern Vertical pattern


Frequency: 200 MHz Frequency: 200 MHz

1.0 0.8 0.6 0.4 0.2 0 1.0 0.8 0.6 0.4 0.2 0

Fig. 4-9: Radiation pattern, 200 MHz (antenna module 20 MHz to 200 MHz).

2If the antenna module is turned by 90° when connected, the horizontal and vertical
patterns will be switched.

4067.5945.32-02.00 28
R&S® HE300 Diagrams

Typical radiation patterns of the antenna module 200 MHz to 500 MHz

Patterns apply to normal handling position (handle upright)3

Horizontaldiagramm Vertikaldiagramm
Frequenz: 200 MHz Frequenz: 200 MHz

Horizontal pattern Vertical pattern


Frequency: 200 MHz Frequency: 200 MHz

1.0 0.8 0.6 0.4 0.2 0 1.0 0.8 0.6 0.4 0.2 0

Fig. 4-10: Radiation pattern, 200 MHz (antenna module 200 MHz to 500 MHz).

Horizontaldiagramm Vertikaldiagramm
Frequenz: 500 MHz Frequenz: 500 MHz

Horizontal pattern Vertical pattern


Frequency: 500 MHz Frequency: 500 MHz

1.0 0.8 0.6 0.4 0.2 0 1.0 0.8 0.6 0.4 0.2 0

Fig. 4-11: Radiation pattern, 500 MHz (antenna module 200 MHz to 500 MHz).

3If the antenna module is turned by 90° when connected, the horizontal and vertical
patterns will be switched.

4067.5945.32-02.00 29
R&S® HE300 Diagrams

Typical radiation patterns of the antenna module 500 MHz to 7.5 GHz

Patterns apply to normal handling position (handle upright)4

Horizontaldiagramm Vertikaldiagramm
Frequenz: 500 MHz Frequenz: 500 MHz
bis 7500 MHz bis 7500 MHz

Horizontal pattern Vertical pattern


Frequency: 500 MHz Frequency: 500 MHz
to 7500 MHz to 7500 MHz

1.0 0.8 0.6 0.4 0.2 0 1.0 0.8 0.6 0.4 0.2 0

Fig. 4-12: Radiation pattern, antenna module 500 MHz to 7.5 GHz.

4If the antenna module is turned by 90° when connected, the horizontal and vertical
patterns will be switched.

4067.5945.32-02.00 30
R&S® HE300 Diagrams

-20
-30
dB
-40
-50 Active
Mode
-60
-70
-8 0
-90
-100
-110
-120
-130
Passive
-140 Mode
-150
-160
-170
2 3 4 5
10 10 10 10 10
Frequency / kHz
Fig. 4-13: Gain of HE300 with HE300HF.

100

90
dB/m
80

70
Passive
60 Mode

50 Active
Mode

40

30

20
2 3 4 5
10 10 10 10 10
Frequency / kHz

Fig. 4-14: Antenna factor of HE300 with HE300HF.

4067.5945.32-02.00 31
R&S® HE300 Diagrams

S/N = 1, bandwidth 10 kHz, receiver noise figure 15 dB


90
85
dBuV/m
80
75
70
65

60
55 Passive
50 Mode

45 Active
Mode
40
35
30
25
20
5
10 102 103 104 10
Frequency / kHz
Fig. 4-15: Absolute sensitivity of HE300 with HE300HF.

90

dB(V/m)

80

70

Active
Mode
60

50

40
2 3 4 5
10 10 10 10 10
Frequency / kHz
Fig. 4-16: Destructive field strength of HE300 with HE300HF.

4067.5945.32-02.00 32
R&S® HE300 Diagrams

Typical radiation patterns of the optional antenna module HE300HF, 9 kHz to


20 MHz

Patterns apply to normal handling position (handle upright)5

Horizontaldiagramm Vertikaldiagramm
Frequenz: 9 kHz Frequenz: 9 kHz
bis 20 MHz bis 20 MHz

Horizontal pattern Vertical pattern


Frequency: 9 kHz Frequency: 9 kHz
to 20 MHz to 20 MHz

1.0 0.8 0.6 0.4 0.2 0 1.0 0.8 0.6 0.4 0.2 0

Fig. 4-17: Radiation patterns of optional antenna module HE300HF, 9 kHz to 20 MHz.

5If the antenna module is turned by 90° when connected, the horizontal and vertical
patterns will be switched.

4067.5945.32-02.00 33