Alarm Unit Alarm no Possible faulty plug in units

2 CLAB FAILUREIN
RAM FAILURE CLAB 2761 CLAB, CLAB-x, SBUS
3 SYNCHRONIZATION UNIT
TG FAILURE IN SYNCRONIZATION CLS 1630 CLG-x, CLCP, CLxTG, CLxTG-x
4 UNIT
FAILURE IN COMMUNICATION CLS 2057 CLxTG, CLxTG-x, strappings
5 CHANNEL ACTIVATION CLS 2172 CLG-x, CLCP, CLOS
6 PHASE METER FAILURE CLS 2630 CLPM
7 OSCILLATOR FAILURE
FAILURE IN THE CHOICE OF CLS 2632 CLG-x, CLOS, CLxTG, CLxTG-x
8 SYNCHRONIZATION
POWER FAILURE IN SIGNAL CLS 2633 CLG-x, CLPM, CLxTG, CLxTG-x
9 SYNCHRONIZATION UNIT
ABSENT PLUG-IN UNIT IN CLS 2634 Power supply, CLxTG, CLxTG-x
10 SYNCHRONIZATION UNIT
FAILURE IN OUTGOING CLOCK CLS 2635 CLOS, CLPM, CLCP
11 SIGNAL
FAILURE IN BUS BETWEEN CLS 2636 CLG-x, CLxTG, CLxTG-x
12 SYNCHRONIZATION UNITS
FAILURE IN SYNCHRONIZATION CLS 2638 CLG-x, CLCP, CLxTG, CLxTG-x
13 UNIT SWITCHOVER
OUTGOING SIGNALS NOT IN CLS 2639 CLG-x, CLOS, CLxTG, CLxTG-x
14 PHASE
CHECKSUM ERROR IN CLS 2640 CLG-x, CLOS, CLxTG, CLxTG-x
15 SYNCHRONIZATION UNIT
FAULTY TIME SLOT IN ROM OF
TESTING CLS 2642 CLG-x, CLCP, CLxTG, CLxTG-x
16 TIME
TOTALSLOT BASED
FAILURE OFUNIT
TIME SLOT CNFC 2621 CNFC
ECHO CANCELLER
17 BASED UNIT
DAUGHTERBOARD LOADING CNFC 2623 CNFC
18 FAILURE ET 1037 EC2ET-x, ECE2-x
ET1E, ET2E/ET4E/ET2A,
19 ET CLOCK FAILURE ET 2039 ET1E
ECET, FRAL, IR/TR, AFS-x,
20 ET FAILURE ET 2202 AFS-x
21 AIS COMMAND ACK ET 2203 ET1E, FRAL, IR/TR
ET1E, FRAL, AFS-x, or other
22 ET2 FAILURE ET 2205 ET2E/ET4E/ET2A
plug-in units in the switching
23 AFS
ECHOCONNECTION
CANCELLER FAILURE
CHANNEL ET 2402 network
24 FAILURE
ECHO CANCELLER SELF TEST ET 2737 EC2ET-x, ECE2-x
25 FAILED
ECHO CANCELLER COMPONENT ET 2738 EC2ET-x, ECE2-x
26 FAILURE
ECHO CANCELLER CLOCK ET 2746 EC2ET-x, ECE2-x
27 FAILURE ET
M (CLO 2747 EC2ET-x, ECE2-xCP5xxx,
CP3xxx, CP4xxx,
28 UNIT RESTARTED GSW)
M (CLO 1001 CP6xxx,
CP3xxx, CP7xxx
CP4xxx, CP5xxx,
29 RAM FAILURE GSW)
M (CLO 1002 CP6xxx,
CP3xxx, CP7xxx CP5xxx,
CP3xxx, CP4xxx,
CP4xxx, CP5xxx,
30 PARITY ERROR TO
NO RESPONSE IN RAM
UNIT GSW)
M (CLO 1003 CP6xxx,
CP6xxx, CP7xxx
CP7xxx, SWCOP,
31 SUPERVISION
ERROR IN MESSAGE
SWITCH COMPARE GSW)
M (CLO 1010 SWCOP-x,
SWCOP, MBIF-x SWCSM,
SWCOP-x,
ERROR BETWEEN MARKER CP3xxx, CP4xxx, CP5xxx,
32 TEST
TABLES AND SWITCH GSW) 1044 SWCSM-x, SWSPS, SWSPS-x
NO RESPONSE FROM CONTROL M (CLO CP6xxx, CP7xxx, SWCSM,
33 MEMORY
CONTROLLER OF SWITCHING GSW)
M (CLO 1045 SWCSM-x
SWCOP, SWCOP-x, SWCSM,
34 NETWORK
CONTROLLER OF SWITCHING GSW)
M (CLO 1047 SWCSM-x, SWSPS, SWSPS-x
SWCOP, SWCOP-x, SWCSM,
ERROR BETWEEN MARKER
35 NETWORK
TABLES ANDRESTARTED
LSW CONTROL GSW)
M (CLO 1048 SWCSM-x, SWSPS, SWSPS-x
36 MEMORY
CHECKSUM ERROR IN LOAD GSW)
M (CLO 1059 SWCOP-x
CP3xxx, CP4xxx, CP5xxx,
37 MODULE GSW)
M (CLO 2005 CP6xxx, CP7xxx
38 GSW)
M (CLO 2020 CLG, CLG-x, CLB
39 MFCU CLOCK FAILURE GSW)
M (CLO 2021 CLG, CLG-x, CLB
40 CLOCK BUFFER ALARM GSW)
M (CLO 2022 CLG, CLG-x, CLB
41 MAIN CLOCK FAILURE GSW)
M (CLO 2023 CLG
42 MAIN
MAIN CLOCK
CLOCK NEEDS ADJUSTMENT GSW)
SYNCHRONIZATION M (CLO 2024 CLG
43 SIGNAL MISSING GSW) 2025 CLG
M (CLO
44 MAIN CLOCK FAILURE GSW)
M (CLO 2029 CLG
45 MB CLOCK FAILURE GSW)
M (CLO 2031 CLG, CLG-x, CLB, MBIF-x
46 GSW CLOCK FAILURE GSW)
M (CLO 2033 CLG, CLG-x, CLB
47 EXCESSIVE ERRORS IN GSW)
M (CLO 2040 TG, TG-x,SWCOP-x,
SWCOP, TGFP-x SWCSM,
48 SWITCHING GSW) 2041 CP3xxx, CP4xxx,
SWCSM-x, SWSPS, CP5xxx,
SWSPS-x
EXCESSIVE ERRORS IN SWITCH M (CLO CP6xxx, CP7xxx, SWCOP,
49 TESTING MODULE
EXCESSIVE GSW) 2043 SWCOP, SWCOP-x
EXCESSIVE ERRORS
ERRORS IN SWITCH
BETWEEN M (CLO SWCOP-x, SWCSM,
CP3xxx, CP4xxx, SWCSM-x,
CP5xxx,
50 COMPARE TEST
SWITCH FILE AND SWITCH GSW)
M (CLO 2044 SWSPS, SWSPS-x
CP6xxx, CP7xxx, SWCSM,
51 CONTROL MEMORY GSW)
M (CLO 2045 SWCSM-x
SWCSM, SWCSM-x, SWSPS,
52 GSW)
M (CLO 2050 SWSPS-x
53 SWITCH CLOCK FAILURE
CHECKSUM ERROR IN SWCOP GSW)
M (CLO 2052 SWCSM, SWCSM-x
54 PROM
CHECKSUM ERROR IN BOOT GSW)
M (CLO 2053 SWCOP, SWCOP-x
CP3xxx, CP4xxx, CP5xxx,
55 PROM GSW)
M (CLO 2054 CP6xxx, CP7xxx
56 VANG FAILURE
CHECKSUM ERROR IN VANG GSW)
M (CLO 2055 VANG, VANG-x
57 SAMPLE
LOOP TEST FAILED IN SIGNALLING GSW)
M (CLO 2056 VANG,
SWCOP,VANG-x
SWCOP-x, SWCSM,
58 LINK
LOOPTERMINAL
TEST FAILED IN PRIMARY GSW)
M (CLO 2079 SWCSM-x, SWSPS, SWSPS-x
SWCSM, SWCSM-x, SWSPS,
59 RATE ACCESS TERMINAL GSW)
M (CLO 2252 SWSPS-x
60 TONE GENERATOR FAILURE GSW)
M (CLO 2409 TGFP-x
CP3xxx, CP4xxx, CP5xxx,
61 CHECKSUM ERROR IN FILE BLOCK GSW)
M (CLO 2426 CP6xxx, CP7xxx
62 VANG PCM INTERFACE FAULTY GSW)
M (CLO 2626 VANG,
MBIF-x,VANG-x
CLxTG,CLxTG-x,
63 CARTRIDGE CLOCK FAILURE
CARTRIDGE POWER SUPPLY GSW)
M (CLO 2755 CLAB, CLAB-x
64 FAILURE
CARTRIDGE NON-REDUNDANT GSW)
M (CLO 2756 Cartridge power supply
MBIF-x, CLxTG,CLxTG-x,
65 POWER SUPPLY
OPERATING FAILURE
SYSTEM ERROR GSW) 2757 CLAB,CLAB-x
66 COUNTER INCREASED MB 1015 MBIF-x
67 MB INTERFACE FAILURE MB 1016 MBIF-x
MBIF-x, CLG ,CLG-x, CLB,
68 MB COMMUNICATION ERROR MB 2015 MBIF-x
CLAB, CLAB-x, CLxTG, CLxTG-
69 MB CLOCK FAILURE MB 2031 xCP3xxx, CP4xxx, CP5xxx,
70 UNIT RESTARTED OMU 1001 CP6xxx,
CP3xxx, CP7xxx
CP4xxx, CP5xxx,
71 RAM FAILURE OMU 1002 CP6xxx,
CP3xxx, CP7xxx
CP4xxx, CP5xxx,
72 PARITY ERROR IN RAM OMU 1003 CP6xxx, CP7xxx
73 ASS PLUG-IN UNIT
NO RESPONSE TO RAM
ASS FAILURE OMU 1172 ASS, ASS-x
74 SUPERVISION MESSAGE
X.25/ETHERNET DATA TERMINAL OMU 1174 ASS, ASS-x
75 SPONTANEOUS RESTART OMU 1260 AC25-x, AS7-x
76 AS7 RESTARTED
NO RESPONSE TO AS7 OMU 1891 AS7-x
77 SUPERVISION MESSAGE
CHECKSUM ERROR IN LOAD OMU 1894 AS7-x
CP3xxx, CP4xxx, CP5xxx,
78 MODULE OMU 2005 CP6xxx, CP7xxx
79 PLUG-IN
PLUG-IN UNIT
UNIT LOCATION
SOFTWAREERROR OMU 2137 AC25-x, AS7-x
80 PACKAGE CHECK
PLUG-IN UNIT SUM ERROR
SOFTWARE OMU 2138 AC25-x, AS7-x
81 PACKAGE LOAD
PLUG-IN UNIT FAILURE
INITIALIZATION OMU 2139 AC25-x, AS7-x
82 FAILURE
PLUG-IN UNIT SUPERVISION OMU 2141 AC25-x, AS7-x
83 FAILURE OMU 2142 AC25-x, AS7-x
84 CHECKSUM ERROR IN ASS ROM OMU 2170 ASS, ASS-x
85 AAL FAILURE OMU 2400 AAL, AAL-x
86 SERIAL CHANNEL FAILURE OMU 2403 SERO
CP3xxx, CP4xxx, CP5xxx,
87 CHECKSUM ERROR IN FILE BLOCK OMU 2426 CP6xxx, CP7xxx
88 HWAT FAILURE OMU 2760 HWAT,
CP3xxx,HWAT-x
CP4xxx, CP5xxx,
89 UNIT RESTARTED STU 1001 CP6xxx,
CP3xxx, CP7xxx
CP4xxx, CP5xxx,
90 RAM FAILURE STU 1002 CP6xxx,
CP3xxx, CP7xxx CP5xxx,
CP3xxx, CP4xxx,
CP4xxx, CP5xxx,
91 PARITY ERROR TO
NO RESPONSE IN RAM
UNIT STU 1003 CP6xxx,
CP6xxx, CP7xxx
CP7xxx, MBIF-x,
92 SUPERVISION MESSAGE
CHECKSUM ERROR IN LOAD STU 1010 SCSIF
CP3xxx, CP4xxx, CP5xxx,
93 MODULE STU 2005 CP6xxx,
CP3xxx, CP7xxx
CP4xxx, CP5xxx,
94 CHECKSUM ERROR IN FILE BLOCK STU 2426 CP6xxx,
CP3xxx, CP7xxx
CP4xxx, CP5xxx,
95 UNIT RESTARTED CM 1001 CP6xxx,
CP3xxx, CP7xxx
CP4xxx, CP5xxx,
96 RAM FAILURE CM 1002 CP6xxx,
CP3xxx, CP7xxx
CP4xxx, CP5xxx,
97 PARITY ERROR TO
NO RESPONSE IN RAM
UNIT CM 1003 CP6xxx,
CP3xxx, CP7xxx
CP4xxx, CP5xxx,
98 SUPERVISION MESSAGE CM 1010 CP6xxx, CP7xxx, MBIF-x
99 MB INTERFACE
EXCESSIVE FAILURE
DISTURBANCES IN CM 1016 MBIF-x
100 SUPERVISION
CHECKSUM ERROR IN LOAD CM 1023 SECMO-x
CP3xxx, CP4xxx, CP5xxx,
101 MODULE CM 2005 CP6xxx, CP7xxx
102 VANG FAILURE
CHECKSUM ERROR IN VANG CM 2055 VANG, VANG-x
103 SAMPLE
SEND BUFFER OVERFLOW IN CM 2056 VANG, VANG-x
104 SIGNALLING TERMINAL CM 2133 SECMO-x
105 PLUG-IN
PLUG-IN UNIT
UNIT LOCATION
SOFTWAREERROR CM 2137 SECMO-x
106 PACKAGE CHECK
PLUG-IN UNIT SUM ERROR
SOFTWARE CM 2138 SECMO-x
107 PACKAGE LOAD FAILURE CM 2139 SECMO-x
108 PLUG-IN UNIT MEMORY FAILURE CM 2416 SECMO-x
109 HARDWARE INTERFACE ERROR CM 2418 SECMO-x
110 PLUG-IN
PLUG-IN UNIT
UNIT START FAILED
SECURITY CM 2419 SECMO-x
111 VIOLATION CM 2237 SECMO-x
CP3xxx, CP4xxx, CP5xxx,
112 CHECKSUM ERROR IN FILE BLOCK CM 2426 CP6xxx, CP7xxx
113 VANG PCM INTERFACE FAULTY CM 2626 VANG, VANG-x
114 UNIT RESTARTED CMM 1001 CP5xxx, CP6xxx, CP7xxx
115 RAM FAILURE CMM 1002 CP5xxx, CP6xxx, CP7xxx
116 PARITY ERROR TO
NO RESPONSE IN RAM
UNIT CMM 1003 CP5xxx,
CP5xxx, CP6xxx,
CP6xxx, CP7xxx
CP7xxx,
117 SUPERVISION MESSAGE CMM 1010 MBIF-x, SWCOP-A
118 MB INTERFACE
ERROR FAILURE CMM 1016 MBIF-x
ERROR IN SWITCH
BETWEEN COMPARE
MARKER
119 TEST
TABLES AND SWITCH CMM 1044 SWCOP-A
NO RESPONSE FROM CONTROL
120 MEMORY
CONTROLLER OF SWITCHING CMM 1045 CP5xxx, CP6xxx, CP7xxx
121 NETWORK
CONTROLLER OF SWITCHING CMM 1047 SWCOP-A
ERROR BETWEEN MARKER
122 NETWORK RESTARTED
TABLES AND LSW CONTROL CMM 1048 SWCOP-A
123 MEMORY
CHECKSUM ERROR IN LOAD CMM 1059 SWCOP-A
124 MODULE CMM 2005 CP5xxx, CP6xxx, CP7xxx
125 MB CLOCK FAILURE
EXCESSIVE ERRORS IN CMM 2031 MBIF-x
126 SWITCHING
EXCESSIVE ERRORS IN SWITCH CMM 2041 SWCOP-A
127 TESTING MODULE
EXCESSIVE CMM 2043 SWCOP-A
EXCESSIVE ERRORS
ERRORS IN SWITCH
BETWEEN CP5xxx, CP6xxx, CP7xxx,
128 COMPARE TEST
SWITCH FILE AND SWITCH CMM 2044 SWCOP-A
129 CONTROL MEMORY CMM 2045 CP5xxx, CP6xxx, CP7xxx
CHECKSUM ERROR IN SWCOP
130 PROM
CHECKSUM ERROR IN BOOT CMM 2053 SWCOP-A
131 PROM CMM 2054 CP5xxx, CP6xxx, CP7xxx
132 VANG FAILURE
CHECKSUM ERROR IN VANG CMM 2055 VANG-A
133 SAMPLE
LOOP TEST FAILED IN SIGNALLING CMM 2056 VANG-A
134 LINK TERMINAL CMM 2079 SWCOP-A
135 TONE GENERATOR FAILURE CMM 2409 TGFP-A
136 CHECKSUM ERROR IN FILE BLOCK CMM 2426 CP5xxx, CP6xxx, CP7xxx
137 VANG PCM INTERFACE FAULTY CMM 2626 VANG-A
138 CARTRIDGE
CARTRIDGE CLOCK FAILURE
NON-REDUNDANT CMM 2755 MBIF-x
139 POWER SUPPLY FAILURE CMM 2757 MBIF-x
140 UNIT RESTARTED GSU 1001 CP5xxx, CP6xxx, CP7xxx
141 RAM FAILURE GSU 1002 CP5xxx, CP6xxx, CP7xxx
142 PARITY ERROR TO
NO RESPONSE IN RAM
UNIT GSU 1003 CP5xxx,
CP5xxx, CP6xxx,
CP6xxx, CP7xxx
CP7xxx,
143 SUPERVISION MESSAGE GSU 1010 MBIF-x
ERROR BETWEEN MARKER
144 MB INTERFACE
TABLES FAILURE
AND SWITCH CONTROL GSU 1016 MBIF-x
145 MEMORY
SIGNALLING LINK OUT OF GSU 1045 CP5xxx, CP6xxx, CP7xxx
146 SERVICE
X.25/ETHERNET DATA TERMINAL GSU 1072 AS7–x
147 SPONTANEOUS RESTART GSU 1260 AS7–x
148 AS7 RESTARTED
NO RESPONSE TO AS7 GSU 1891 AS7–x
149 SUPERVISION MESSAGE
CHECKSUM ERROR IN LOAD GSU 1894 AS7–x
150 MODULE GSU 2005 CP5xxx, CP6xxx, CP7xxx
151 MB CLOCK FAILURE IN SWITCH
EXCESSIVE GSU 2031 MBIF-x
EXCESSIVE ERRORS
ERRORS BETWEEN
152 COMPARE TEST
SWITCH FILE AND SWITCH GSU 2044 CP5xxx, CP6xxx, CP7xxx
153 CONTROL
CHECKSUM MEMORY
ERROR IN BOOT GSU 2045 CP5xxx, CP6xxx, CP7xxx
154 PROM
LOOP TEST FAILED IN SIGNALLING GSU 2054 CP5xxx, CP6xxx, CP7xxx
155 LINK TERMINAL GSU 2079 AS7–x
156 PLUG-IN
PLUG-IN UNIT
UNIT LOCATION
SOFTWAREERROR GSU 2137 AS7–x
157 PACKAGE CHECK
PLUG-IN UNIT SUM ERROR
SOFTWARE GSU 2138 AS7–x
158 PACKAGE LOAD
PLUG-IN UNIT FAILURE
INITIALIZATION GSU 2139 AS7–x
159 FAILURE
PLUG-IN UNIT SUPERVISION GSU 2141 AS7–x
160 FAILURE GSU 2142 AS7–x
161 CHECKSUM ERROR IN FILE BLOCK GSU 2426 CP5xxx, CP6xxx, CP7xxx
162 CARTRIDGE
CARTRIDGE CLOCK FAILURE
NON-REDUNDANT GSU 2755 MBIF-x
163 POWER SUPPLY FAILURE GSU 2757 MBIF-x
164 UNIT RESTARTED DBDU 1001 CP5xxx, CP6xxx, CP7xxx
165 RAM FAILURE DBDU 1002 CP5xxx, CP6xxx, CP7xxx
166 PARITY ERROR TO
NO RESPONSE IN RAM
UNIT DBDU 1003 CP5xxx,
CP5xxx, CP6xxx,
CP6xxx, CP7xxx
CP7xxx,
167 SUPERVISION MESSAGE DBDU 1010 MBIF-x
168 MB INTERFACE
EXCESSIVE FAILURE
DISTURBANCES DBDU 1016 MBIF-x
ERROR BETWEEN MARKER IN
169 SUPERVISION
TABLES AND SWITCH CONTROL DBDU 1023 SECMO-x
170 MEMORY
SIGNALLING LINK OUT OF DBDU 1045 CP5xxx, CP6xxx, CP7xxx
171 SERVICE
PREPROCESSOR UNIT DBDU 1072 AS7–x
172 RESTARTED DBDU 1182 SECMO-x
X.25/ETHERNET DATA TERMINAL
173 SPONTANEOUS RESTART DBDU 1260 AS7–x
174 AS7 RESTARTED
NO RESPONSE TO AS7 DBDU 1891 AS7–x
175 SUPERVISION MESSAGE
CHECKSUM ERROR IN LOAD DBDU 1894 AS7–x
176 MODULE DBDU 2005 CP5xxx, CP6xxx, CP7xxx
177 MB CLOCK FAILURE IN SWITCH
EXCESSIVE DBDU 2031 MBIF-x
EXCESSIVE ERRORS
ERRORS BETWEEN
178 COMPARE TEST
SWITCH FILE AND SWITCH DBDU 2044 CP5xxx, CP6xxx, CP7xxx
179 CONTROL
CHECKSUM MEMORY
ERROR IN BOOT DBDU 2045 CP5xxx, CP6xxx, CP7xxx
180 PROM
LOOP TEST FAILED IN SIGNALLING DBDU 2054 CP5xxx, CP6xxx, CP7xxx
181 LINK
SENDTERMINAL
BUFFER OVERFLOW IN DBDU 2079 AS7–x
182 SIGNALLING TERMINAL DBDU 2133 SECMO-x
183 PLUG-IN
PLUG-IN UNIT
UNIT LOCATION
SOFTWAREERROR DBDU 2137 AS7–x
184 PACKAGE CHECK
PLUG-IN UNIT SUM ERROR
SOFTWARE DBDU 2138 AS7–x
185 PACKAGE LOAD
PLUG-IN UNIT FAILURE
INITIALIZATION DBDU 2139 AS7–x, SECMO-x
186 FAILURE
PLUG-IN UNIT SUPERVISION DBDU 2141 AS7–x
187 FAILURE DBDU 2142 AS7–x
188 PLUG-IN UNIT MEMORY FAILURE DBDU 2416 SECMO-A
189 HARDWARE
PLUG-IN UNITINTERFACE
SECURITY ERROR DBDU 2418 SECMO-A
190 VIOLATION DBDU 2237 SECMO-x
191 PREPROCESSOR UNIT FAILURE
HARDWARE INTERFACE DBDU 2770 SECMO-x
192 INITIALIZATION ERROR DBDU 2275 SECMO-x
193 PLUG-IN UNIT START FAILED DBDU 2419 SECMO-x
194 CHECKSUM ERROR IN FILE BLOCK DBDU 2426 CP5xxx, CP6xxx, CP7xxx
195 CARTRIDGE
CARTRIDGE CLOCK FAILURE
NON-REDUNDANT DBDU 2755 MBIF-x
196 POWER SUPPLY FAILURE DBDU 2757 MBIF-x
197 UNIT RESTARTED EMU 1001 CP5xxx, CP6xxx, CP7xxx
198 RAM FAILURE EMU 1002 CP5xxx, CP6xxx, CP7xxx
199 PARITY
NO ERROR TO
RESPONSE IN RAM
UNIT EMU 1003 CP5xxx, CP6xxx, CP7xxx
ERROR BETWEEN MARKER
200 SUPERVISION MESSAGE
TABLES AND SWITCH CONTROL EMU 1010 CP5xxx, CP6xxx, CP7xxx
201 MEMORY
SIGNALLING LINK OUT OF EMU 1045 CP5xxx, CP6xxx, CP7xxx
202 SERVICE
X.25/ETHERNET DATA TERMINAL EMU 1072 AS7–x
203 SPONTANEOUS RESTART EMU 1260 AS7–x
204 AS7 RESTARTED
NO RESPONSE TO AS7 EMU 1891 AS7–x
205 SUPERVISION MESSAGE
CHECKSUM ERROR IN LOAD EMU 1894 AS7–x
206 MODULE
EXCESSIVE EMU 2005 CP5xxx, CP6xxx, CP7xxx
EXCESSIVE ERRORS
ERRORS IN SWITCH
BETWEEN
207 COMPARE TEST
SWITCH FILE AND SWITCH EMU 2044 CP5xxx, CP6xxx, CP7xxx
208 CONTROL
CHECKSUM MEMORY
ERROR IN BOOT EMU 2045 CP5xxx, CP6xxx, CP7xxx
209 PROM
LOOP TEST FAILED IN SIGNALLING EMU 2054 CP5xxx, CP6xxx, CP7xxx
210 LINK TERMINAL EMU 2079 AS7–x
211 PLUG-IN
PLUG-IN UNIT
UNIT LOCATION
SOFTWAREERROR EMU 2137 AS7–x
212 PACKAGE CHECK
PLUG-IN UNIT SUM ERROR
SOFTWARE EMU 2138 AS7–x
213 PACKAGE LOAD
PLUG-IN UNIT FAILURE
INITIALIZATION EMU 2139 AS7–x
214 FAILURE
PLUG-IN UNIT SUPERVISION EMU 2141 AS7–x
215 FAILURE EMU 2142 AS7–x
216 CHECKSUM ERROR IN FILE BLOCK EMU 2426 CP5xxx, CP6xxx, CP7xxx
217 UNIT RESTARTED MFSU 1001 CP5xxx, CP6xxx, CP7xxx
218 RAM FAILURE MFSU 1002 CP5xxx, CP6xxx, CP7xxx
219 PARITY ERROR TO
NO RESPONSE IN RAM
UNIT MFSU 1003 CP5xxx,
CP5xxx, CP6xxx,
CP6xxx, CP7xxx
CP7xxx,
220 SUPERVISION MESSAGE MFSU 1010 MBIF-x
ERROR BETWEEN MARKER
221 MB INTERFACE
TABLES FAILURE
AND SWITCH CONTROL MFSU 1016 MBIF-x
222 MEMORY
CHECKSUM ERROR IN LOAD MFSU 1045 CP5xxx, CP6xxx, CP7xxx
223 MODULE MFSU 2005 CP5xxx, CP6xxx, CP7xxx
224 MB CLOCK FAILURE IN SWITCH
EXCESSIVE MFSU 2031 MBIF-x
EXCESSIVE ERRORS
ERRORS BETWEEN
225 COMPARE TEST
SWITCH FILE AND SWITCH MFSU 2044 CP5xxx, CP6xxx, CP7xxx
226 CONTROL
CHECKSUM MEMORY
ERROR IN BOOT MFSU 2045 CP5xxx, CP6xxx, CP7xxx
227 PROM MFSU 2054 CP5xxx, CP6xxx, CP7xxx
228 PLUG-IN
PLUG-IN UNIT
UNIT LOCATION
SOFTWAREERROR MFSU 2137 MFST-A
229 PACKAGE CHECK
PLUG-IN UNIT SUM ERROR
SOFTWARE MFSU 2138 MFST-A
230 PACKAGE LOAD
PLUG-IN UNIT FAILURE
INITIALIZATION MFSU 2139 MFST-A
231 FAILURE
PLUG-IN UNIT SUPERVISION MFSU 2141 MFST-A
232 FAILURE MFSU 2142 MFST-A
CP5xxx, CP6xxx, CP7xxx,
233 CHECKSUM ERROR IN FILE BLOCK MFSU 2426 MFST-A
234 MFST FUNCTION FAULTY MFSU 2625 MFST-A
235 CARTRIDGE
CARTRIDGE CLOCK FAILURE
NON-REDUNDANT MFSU 2755 MBIF-x
236 POWER SUPPLY FAILURE MFSU 2757 MBIF-x
CP3xxx, CP4xxx, CP5xxx,
237 UNIT RESTARTED LSU 1001 CP6xxx,
CP3xxx, CP7xxx
CP4xxx, CP5xxx,
238 RAM FAILURE LSU 1002 CP6xxx,
CP3xxx, CP7xxx CP5xxx,
CP3xxx, CP4xxx,
CP4xxx, CP5xxx,
239 PARITY ERROR TO
NO RESPONSE IN RAM
UNIT LSU 1003 CP6xxx,
CP6xxx, CP7xxx
CP7xxx, LSP, LSP-x,
240 SUPERVISION MESSAGE
SIGNALLING LINK OUT OF LSU 1010 AFS-x
241 SERVICE LSU 1072 AS7-x
242 LSP RESTARTED LSU 1101 LSP, LSP-x
243 LSP RAM FAILURE
NO RESPONSE TO LSP LSU 1102 LSP, LSP-x
244 SUPERVISION MESSAGE LSU 1104 LSP, LSP-x
245 AS7 RESTARTED
NO RESPONSE TO AS7 LSU 1891 AS7-x
246 SUPERVISION MESSAGE
CHECKSUM ERROR IN LOAD LSU 1894 AS7-x
CP3xxx, CP4xxx, CP5xxx,
247 MODULE
LOOP TEST FAILED IN SIGNALLING LSU 2005 CP6xxx, CP7xxx
248 LINK TERMINAL LSU 2079 AS7-x
249 CHECKSUM ERROR IN LSP ROM LSU 2100 LSP, LSP-x
250 PLUG-IN
PLUG-IN UNIT
UNIT LOCATION
SOFTWAREERROR LSU 2137 AS7-x
251 PACKAGE CHECK
PLUG-IN UNIT SUM ERROR
SOFTWARE LSU 2138 AS7-x
252 PACKAGE LOAD
PLUG-IN UNIT FAILURE
INITIALIZATION LSU 2139 AS7-x
253 FAILURE
PLUG-IN UNIT SUPERVISION LSU 2141 AS7-x
254 FAILURE LSU 2142 AS7-x
CP3xxx, CP4xxx, CP5xxx,
255 CHECKSUM ERROR IN FILE BLOCK LSU 2426 CP6xxx,
CP3xxx, CP7xxx
CP4xxx, CP5xxx,
256 UNIT RESTARTED CCSU 1001 CP6xxx,
CP3xxx, CP7xxx
CP4xxx, CP5xxx,
257 RAM FAILURE CCSU 1002 CP6xxx,
CP3xxx, CP7xxx
CP4xxx, CP5xxx,
258 PARITY ERROR IN RAM CCSU 1003 CP6xxx, CP7xxx
NO RESPONSE TO UNIT CP3xxx, CP4xxx, CP5xxx,
259 SUPERVISION MESSAGE
SIGNALLING LINK OUT OF CCSU 1010 CP6xxx, CP7xxx, AFS-x
260 SERVICE CCSU 1072 AS7-x
261 AS7 RESTARTED
NO RESPONSE TO AS7 CCSU 1891 AS7-x
262 SUPERVISION MESSAGE
CHECKSUM ERROR IN LOAD CCSU 1894 AS7-x
CP3xxx, CP4xxx, CP5xxx,
263 MODULE
LOOP TEST FAILED IN SIGNALLING CCSU 2005 CP6xxx, CP7xxx
264 LINK TERMINAL CCSU 2079 AS7-x
265 PLUG-IN
PLUG-IN UNIT
UNIT LOCATION
SOFTWAREERROR CCSU 2137 AS7-x
266 PACKAGE CHECK
PLUG-IN UNIT SUM ERROR
SOFTWARE CCSU 2138 AS7-x
267 PACKAGE LOAD
PLUG-IN UNIT FAILURE
INITIALIZATION CCSU 2139 AS7-x
268 FAILURE
PLUG-IN UNIT SUPERVISION CCSU 2141 AS7-x
269 FAILURE CCSU 2142 AS7-x
270 AFS FAILURE CCSU 2406 AFS-x
CP3xxx, CP4xxx, CP5xxx,
271 CHECKSUM ERROR IN FILE BLOCK CCSU 2426 CP6xxx,
CP3xxx, CP7xxx
CP4xxx, CP5xxx,
272 UNIT RESTARTED PAU 1001 CP6xxx,
CP3xxx, CP7xxx
CP4xxx, CP5xxx,
273 RAM FAILURE PAU 1002 CP6xxx,
CP3xxx, CP7xxx
CP4xxx, CP5xxx,
274 PARITY ERROR TO
NO RESPONSE IN RAM
UNIT PAU 1003 CP6xxx,
CP3xxx, CP7xxx
CP4xxx, CP5xxx,
275 SUPERVISION MESSAGE
SIGNALLING LINK OUT OF PAU 1010 CP6xxx, CP7xxx, AFS-x
276 SERVICE PAU 1072 AS7-x
277 AS7 RESTARTED
NO RESPONSE TO AS7 PAU 1891 AS7-x
278 SUPERVISION MESSAGE
CHECKSUM ERROR IN LOAD PAU 1894 AS7-x
CP3xxx, CP4xxx, CP5xxx,
279 MODULE
LOOP TEST FAILED IN SIGNALLING PAU 2005 CP6xxx, CP7xxx
280 LINK TERMINAL PAU 2079 AS7-x
281 PLUG-IN UNIT LOCATION
PLUG-IN UNIT SOFTWARE ERROR PAU 2137 AS7-x
282 PACKAGE CHECK
PLUG-IN UNIT SUM ERROR
SOFTWARE PAU 2138 AS7-x
283 PACKAGE LOAD
PLUG-IN UNIT FAILURE
INITIALIZATION PAU 2139 AS7-x
284 FAILURE
PLUG-IN UNIT SUPERVISION PAU 2141 AS7-x
285 FAILURE PAU 2142 AS7-x
286 AFS FAILURE PAU 2406 AFS-x
CP3xxx, CP4xxx, CP5xxx,
287 CHECKSUM ERROR IN FILE BLOCK PAU 2426 CP6xxx,
CP3xxx, CP7xxx
CP4xxx, CP5xxx,
288 UNIT RESTARTED CASU 1001 CP6xxx,
CP3xxx, CP7xxx
CP4xxx, CP5xxx,
289 RAM FAILURE CASU 1002 CP6xxx,
CP3xxx, CP7xxx
CP4xxx, CP5xxx,
290 PARITY ERROR TO
NO RESPONSE IN RAM
UNIT CASU 1003 CP6xxx,
CP3xxx, CP7xxx
CP4xxx, CP6xxx,
291 SUPERVISION MESSAGE
SIGNALLING LINK OUT OF CASU 1010 CP7xxx, MBIF-x
292 SERVICE CASU 1072 AS7-x
293 AS7 RESTARTED
NO RESPONSE TO AS7 CASU 1891 AS7-x
294 SUPERVISION
CHECKSUM ERRORMESSAGE
IN LOAD CASU 1894 AS7-x
CP3xxx, CP4xxx, CP5xxx,
295 MODULE
LOOP TEST FAILED IN SIGNALLING CASU 2005 CP6xxx, CP7xxx
296 LINK TERMINAL CASU 2079 AS7-x
297 PLUG-IN
PLUG-IN UNIT
UNIT LOCATION
SOFTWAREERROR CASU 2137 MFST, MFST-A, AS7-x
298 PACKAGE CHECK
PLUG-IN UNIT SUM ERROR
SOFTWARE CASU 2138 MFST, MFST-A, AS7-x
299 PACKAGE LOAD
PLUG-IN UNIT FAILURE
INITIALIZATION CASU 2139 MFST, MFST-A, AS7-x
300 FAILURE
PLUG-IN UNIT SUPERVISION CASU 2141 MFST, MFST-A, AS7-x
301 FAILURE CASU 2142 MFST, MFST-A, AS7-x
302 AFS FAILURE CASU 2406 AFS-x
CP3xxx, CP4xxx, CP5xxx,
303 CHECKSUM ERROR
FAULTY TIME IN TESTING
SLOT IN FILE BLOCK
OF CASU 2426 CP6xxx, CP7xxx
304 MFST CASU 2624 MFST, MFST-A
305 MFST FUNCTION FAULTY CASU 2625 MFST,
CP3xxx,MFST-A
CP4xxx, CP5xxx,
306 UNIT RESTARTED CHU 1001 CP6xxx,
CP3xxx, CP7xxx
CP4xxx, CP5xxx,
307 RAM FAILURE CHU 1002 CP6xxx,
CP3xxx, CP7xxx CP5xxx,
CP3xxx, CP4xxx,
CP4xxx, CP5xxx,
308 PARITY ERROR TO
NO RESPONSE IN RAM
UNIT CHU 1003 CP6xxx,
CP6xxx, CP7xxx
CP7xxx, MBIF-x,
309 SUPERVISION MESSAGE
CHECKSUM ERROR IN LOAD CHU 1010 SCSIF
CP3xxx, CP4xxx, CP5xxx,
310 MODULE CHU 2005 CP6xxx,
CP3xxx, CP7xxx
CP4xxx, CP5xxx,
311 CHECKSUM ERROR IN FILE BLOCK CHU 2426 CP6xxx,
CP3xxx, CP7xxx
CP4xxx, CP5xxx,
312 UNIT RESTARTED CCMU 1001 CP6xxx,
CP3xxx, CP7xxx
CP4xxx, CP5xxx,
313 RAM FAILURE CCMU 1002 CP6xxx,
CP3xxx, CP7xxx
CP4xxx, CP5xxx,
314 PARITY ERROR TO
NO RESPONSE IN RAM
UNIT CCMU 1003 CP6xxx,
CP3xxx, CP7xxx
CP4xxx, CP5xxx,
315 SUPERVISION MESSAGE
CHECKSUM ERROR IN LOAD CCMU 1010 CP6xxx,
CP3xxx, CP7xxx,
CP4xxx, MBIF-x
CP5xxx,
316 MODULE CCMU 2005 CP6xxx,
CP3xxx, CP7xxx
CP4xxx, CP5xxx,
317 CHECKSUM ERROR IN FILE BLOCK CCMU 2426 CP6xxx,
CP3xxx, CP7xxx
CP4xxx, CP5xxx,
318 UNIT RESTARTED HLRU 1001 CP6xxx,
CP3xxx, CP7xxx
CP4xxx, CP5xxx,
319 RAM FAILURE HLRU 1002 CP6xxx,
CP3xxx, CP7xxx CP5xxx,
CP3xxx, CP4xxx,
CP4xxx, CP5xxx,
320 PARITY ERROR TO
NO RESPONSE IN RAM
UNIT HLRU 1003 CP6xxx,
CP6xxx, CP7xxx
CP7xxx, MBIF-x,
321 SUPERVISION MESSAGE
CHECKSUM ERROR IN LOAD HLRU 1010 SCSIF
CP3xxx, CP4xxx, CP5xxx,
322 MODULE HLRU 2005 CP6xxx,
CP3xxx, CP7xxx
CP4xxx, CP5xxx,
323 CHECKSUM ERROR IN FILE BLOCK HLRU 2426 CP6xxx,
CP3xxx, CP7xxx
CP4xxx, CP5xxx,
324 UNIT RESTARTED EIRU 1001 CP6xxx,
CP3xxx, CP7xxx
CP4xxx, CP5xxx,
325 RAM FAILURE EIRU 1002 CP6xxx,
CP3xxx, CP7xxx
CP4xxx, CP5xxx,
326 PARITY ERROR TO
NO RESPONSE IN RAM
UNIT EIRU 1003 CP6xxx,
CP3xxx, CP7xxx
CP4xxx, CP5xxx,
327 SUPERVISION MESSAGE
CHECKSUM ERROR IN LOAD EIRU 1010 CP6xxx,
CP3xxx, CP7xxx,
CP4xxx, MBIF-x
CP5xxx,
328 MODULE EIRU 2005 CP6xxx,
CP3xxx, CP7xxx
CP4xxx, CP5xxx,
329 CHECKSUM ERROR IN FILE BLOCK EIRU 2426 CP6xxx,
CP3xxx, CP7xxx
CP4xxx, CP5xxx,
330 UNIT RESTARTED VLRU 1001 CP6xxx,
CP3xxx, CP7xxx
CP4xxx, CP5xxx,
331 RAM FAILURE VLRU 1002 CP6xxx,
CP3xxx, CP7xxx
CP4xxx, CP5xxx,
332 PARITY ERROR TO
NO RESPONSE IN RAM
UNIT VLRU 1003 CP6xxx,
CP3xxx, CP7xxx
CP4xxx, CP5xxx,
333 SUPERVISION MESSAGE
CHECKSUM ERROR IN LOAD VLRU 1010 CP6xxx,
CP3xxx, CP7xxx,
CP4xxx, MBIF-x
CP5xxx,
334 MODULE VLRU 2005 CP6xxx, CP7xxx
CP3xxx, CP4xxx, CP5xxx,
335 CHECKSUM ERROR IN FILE BLOCK VLRU 2426 CP6xxx,
CP3xxx, CP7xxx
CP4xxx, CP5xxx,
336 UNIT RESTARTED CMU 1001 CP6xxx,
CP3xxx, CP7xxx
CP4xxx, CP5xxx,
337 RAM FAILURE CMU 1002 CP6xxx,
CP3xxx, CP7xxx
CP4xxx, CP5xxx,
338 PARITY ERROR TO
NO RESPONSE IN RAM
UNIT CMU 1003 CP6xxx,
CP3xxx, CP7xxx
CP4xxx, CP5xxx,
339 SUPERVISION MESSAGE
CHECKSUM ERROR IN LOAD CMU 1010 CP6xxx,
CP3xxx, CP7xxx,
CP4xxx, MBIF-x
CP5xxx,
340 MODULE CMU 2005 CP6xxx,
CP3xxx, CP7xxx
CP4xxx, CP5xxx,
341 CHECKSUM ERROR IN FILE BLOCK CMU 2426 CP6xxx,
CP3xxx, CP7xxx
CP4xxx, CP5xxx,
342 UNIT RESTARTED BSU 1001 CP6xxx,
CP3xxx, CP7xxx
CP4xxx, CP5xxx,
343 RAM FAILURE BSU 1002 CP6xxx,
CP3xxx, CP7xxx
CP4xxx, CP5xxx,
344 PARITY ERROR IN RAM BSU 1003 CP6xxx, CP7xxx
NO RESPONSE TO UNIT CP3xxx, CP4xxx, CP5xxx,
345 SUPERVISION MESSAGE
SIGNALLING LINK OUT OF BSU 1010 CP6xxx, CP7xxx, MBIF-x
346 SERVICE BSU 1072 AS7-x
347 AS7 RESTARTED
NO RESPONSE TO AS7 BSU 1891 AS7-x
348 SUPERVISION MESSAGE
CHECKSUM ERROR IN LOAD BSU 1894 AS7-x
CP3xxx, CP4xxx, CP5xxx,
349 MODULE
LOOP TEST FAILED IN SIGNALLING BSU 2005 CP6xxx, CP7xxx
350 LINK TERMINAL BSU 2079 AS7-x
351 PLUG-IN
PLUG-IN UNIT
UNIT LOCATION
SOFTWAREERROR BSU 2137 AS7-x
352 PACKAGE CHECK
PLUG-IN UNIT SUM ERROR
SOFTWARE BSU 2138 AS7-x
353 PACKAGE LOAD
PLUG-IN UNIT FAILURE
INITIALIZATION BSU 2139 AS7-x
354 FAILURE
PLUG-IN UNIT SUPERVISION BSU 2141 AS7-x
355 FAILURE BSU 2142 AS7-x
356 AFS FAILURE BSU 2406 AFS-x
CP3xxx, CP4xxx, CP5xxx,
357 CHECKSUM ERROR IN FILE BLOCK BSU 2426 CP6xxx, CP7xxx
358 UNIT RESTARTED IWCU 1001 CP3xxx, CP4xxx
359 RAM FAILURE IWCU 1002 CP3xxx, CP4xxx
360 PARITY ERROR TO
NO RESPONSE IN RAM
UNIT IWCU 1003 CP3xxx, CP4xxx
361 SUPERVISION MESSAGE
SIGNALLING LINK OUT OF IWCU 1010 CP3xxx, CP4xxx, MBIF-x
362 SERVICE IWCU 1072 AS7-x
363 AS7 RESTARTED
NO RESPONSE TO AS7 IWCU 1891 AS7-x
364 SUPERVISION MESSAGE
CHECKSUM ERROR IN LOAD IWCU 1894 AS7-x
365 MODULE
LOOP TEST FAILED IN SIGNALLING IWCU 2005 CP3xxx, CP4xxx
366 LINK TERMINAL IWCU 2079 AS7-x
367 PLUG-IN UNIT LOCATION
PLUG-IN UNIT SOFTWARE ERROR IWCU 2137 AS7-x
368 PACKAGE CHECK
PLUG-IN UNIT SUM ERROR
SOFTWARE IWCU 2138 AS7-x
369 PACKAGE LOAD
PLUG-IN UNIT FAILURE
INITIALIZATION IWCU 2139 AS7-x
370 FAILURE
PLUG-IN UNIT SUPERVISION IWCU 2141 AS7-x
371 FAILURE IWCU 2142 AS7-x
372 CHECKSUM ERROR IN FILE BLOCK IWCU 2426 CP3xxx,
CP3xxx, CP4xxx
CP4xxx, CP5xxx,
373 UNIT RESTARTED ACU 1001 CP6xxx,
CP3xxx, CP7xxx
CP4xxx, CP5xxx,
374 RAM FAILURE ACU 1002 CP6xxx,
CP3xxx, CP7xxx
CP4xxx, CP5xxx,
375 PARITY ERROR TO
NO RESPONSE IN RAM
UNIT ACU 1003 CP6xxx,
CP3xxx, CP7xxx
CP4xxx, CP5xxx,
376 SUPERVISION MESSAGE
EXCESSIVE DISTURBANCES IN ACU 1010 CP6xxx, CP7xxx, MBIF-x
377 SUPERVISION
PREPROCESSOR UNIT ACU 1023 SECMO-x
378 RESTARTED
CHECKSUM ERROR IN LOAD ACU 1182 SECMO-x
CP3xxx, CP4xxx, CP5xxx,
379 MODULE
SEND BUFFER OVERFLOW IN ACU 2005 CP6xxx, CP7xxx
380 SIGNALLING TERMINAL ACU 2133 SECMO-x
381 PLUG-IN
PLUG-IN UNIT
UNIT LOCATION
SOFTWAREERROR ACU 2137 SECMO-x
382 PACKAGE CHECK
PLUG-IN UNIT SUM ERROR
SOFTWARE ACU 2138 SECMO-x
383 PACKAGE LOAD FAILURE
PLUG-IN UNIT SUPERVISION ACU 2139 SECMO-x
384 FAILURE ACU 2142 SECMO-x
385 PREPROCESSOR UNIT FAILURE
HARDWARE INTERFACE ACU 2770 SECMO-x
386 INITIALIZATION ERROR ACU 2275 SECMO-x
387 PLUG-IN UNIT MEMORY FAILURE ACU 2416 SECMO-x
388 HARDWARE INTERFACE ERROR ACU 2418 SECMO-x
389 PLUG-IN
PLUG-IN UNIT
UNIT START FAILED
SECURITY ACU 2419 SECMO-x
390 VIOLATION ACU 2237 SECMO-x
CP3xxx, CP4xxx, CP5xxx,
391 CHECKSUM ERROR IN FILE BLOCK ACU 2426 CP6xxx,
CP3xxx, CP7xxx
CP4xxx, CP5xxx,
392 UNIT RESTARTED BDCU 1001 CP6xxx,
CP3xxx, CP7xxx
CP4xxx, CP5xxx,
393 RAM FAILURE BDCU 1002 CP6xxx,
CP3xxx, CP7xxx
CP4xxx, CP5xxx,
394 PARITY ERROR TO
NO RESPONSE IN RAM
UNIT BDCU 1003 CP6xxx,
CP3xxx, CP7xxx
CP4xxx, CP5xxx,
395 SUPERVISION MESSAGE
SIGNALLING LINK OUT OF BDCU 1010 CP6xxx, CP7xxx, MBIF-x
396 SERVICE
X.25/ETHERNET DATA TERMINAL BDCU 1072 AS7-x
397 SPONTANEOUS RESTART BDCU 1260 AC25-x, AS7-x, COCEN
398 AS7 RESTARTED
NO RESPONSE TO AS7 BDCU 1891 AS7-x
399 SUPERVISION MESSAGE
CHECKSUM ERROR IN LOAD BDCU 1894 AS7-x
CP3xxx, CP4xxx, CP5xxx,
400 MODULE
LOOP TEST FAILED IN SIGNALLING BDCU 2005 CP6xxx, CP7xxx
401 LINK TERMINAL BDCU 2079 AS7-x
402 PLUG-IN
PLUG-IN UNIT
UNIT LOCATION
SOFTWAREERROR BDCU 2137 AC25-x, AS7-x
403 PACKAGE CHECK
PLUG-IN UNIT SUM ERROR
SOFTWARE BDCU 2138 AC25-x, AS7-x
404 PACKAGE LOAD
PLUG-IN UNIT FAILURE
INITIALIZATION BDCU 2139 AC25-x, AS7-x
405 FAILURE
PLUG-IN UNIT SUPERVISION BDCU 2141 AC25-x, AS7-x
406 FAILURE BDCU 2142 AC25-x,
CP3xxx, AS7-x
CP4xxx, CP5xxx,
407 CHECKSUM ERROR IN FILE BLOCK BDCU 2426 CP6xxx, CP7xxx
408 DSCO FAILURE
PIU OFF THE CARTRIDGE IN CDSU CDSU 2421 DSCO
409 UNIT
CDSU CHANNEL SUPERVISION CDSU 2776 DSMA, DSMA-S
410 FAILED
MOST OF CDSU CHANNELS ARE IN CDSU 2777 DSMA, DSMA-S
411 FAULTY
CDSU PIUSTATE
SOFTWARE LOADING CDSU 2778 DSMA, DSMA-S
412 FAILED CDSU 2779 DSMA, DSMA-S
413 DSCO FAILURE
PIU OFF THE CARTRIDGE IN CDSU NDSM 2421 DSCO
414 UNIT
CDSU CHANNEL SUPERVISION NDSM 2776 DSMA, DSMA-S
415 FAILED
MOST OF CDSU CHANNELS ARE IN NDSM 2777 DSMA, DSMA-S
416 FAULTY
CDSU PIUSTATE
SOFTWARE LOADING NDSM 2778 DSMA, DSMA-S
417 FAILED NDSM 2779 DSMA, DSMA-S
418 DSCO FAILURE
PIU OFF THE CARTRIDGE IN CDSU NDSD 2421 DSCO
419 UNIT
CDSU CHANNEL SUPERVISION NDSD 2776 DSMA, DSMA-S
420 FAILED
MOST OF CDSU CHANNELS ARE IN NDSD 2777 DSMA, DSMA-S
421 FAULTY
CDSU PIUSTATE
SOFTWARE LOADING NDSD 2778 DSMA, DSMA-S
422 FAILED NDSD 2779 DSMA, DSMA-S
423 COCA/EC1P RAM FAILURE MPC 1543 COCA-S
424 DSP OUT OFERROR
CHECKSUM USE IN COCA/EC1P MPC 2542 DASA-S
425 ROM MPC 2544 COCA-S
COCA-S, DM2, VF10, VF10-x,
426 DM2 COCA CONNECTION FAILURE MPC 2546 ET1E
427 MODEM FAILURE MPC 2547 ECMFAST, FAXMO
428 COCA/EC1P FAILURE
DATA SERVICE UNIT IS NOT MPC 2548 COCA-S
429 AVAILABLE MPC 2671 COCA-S
430 MODEM FLOW CONTROL ALARM MPC 2736 ECMFAST, FAXMO
431 COCA/EC1P RAM FAILURE DIC 1543 COCA-S
432 DSP OUT OFERROR
CHECKSUM USE IN COCA/EC1P DIC 2542 DASA-S
433 ROM DIC 2544 COCA-S
434 DM2 COCA CONNECTION FAILURE DIC 2546 COCA-S, DM2, DIU, ET1E
435 COCA/EC1P FAILURE DIC 2548 COCA-S
436 DM2
DATADIU FAILURE
SERVICE UNIT IS NOT DIC 2647 DIU
437 AVAILABLE DIC 2671 COCA-S
438 COCA/EC1P RAM FAILURE DIPC 1543 COCA, COCA-S
439 DSP OUT OFERROR
CHECKSUM USE IN COCA/EC1P DIPC 2542 DASA-S
440 ROM DIPC 2544 COCA, COCA-S
441 COCA/EC1P
DATA FAILURE DIPC 2548 COCA, COCA-S
ECHO SERVICE UNIT IS NOT
CANCELLER
442 AVAILABLE
DAUGHTERBOARD LOADING DIPC 2671 COCA, COCA-S
443 FAILURE ECU 1037 EC1P, EC1P-x
444 COCA/EC1P RAM FAILURE ECU 1543 EC1P, EC1P-x, COCA
445 DSP OUT OFERROR
CHECKSUM USE IN COCA/EC1P ECU 2542 EC08
446 ROM ECU 2544 EC1P, EC1P-x, COCA
447 COCA/EC1P FAILURE ECU 2548 EC1P, EC1P-x, COCA
448 EC08
ECHOOUT OF USE CHANNEL
CANCELLER ECU 2561 EC08
449 FAILURE
ECHO CANCELLER SELF TEST ECU 2737 EC1P, EC1P-x
450 FAILED
ECHO CANCELLER COMPONENT ECU 2738 EC1P, EC1P-x
451 FAILURE
ECHO CANCELLER CLOCK ECU 2746 EC1P, EC1P-x
452 FAILURE ECU 2747 EC1P, EC1P-x