Sunteți pe pagina 1din 1

223 Double Braid (Equivalent to RG 223)

MECHANICAL PARAMETERS
Inner Conductor Silver plated copper wire 0.89 mm
Dielectric PE 2.95 mm
Shield Double Braid of tinned Copper wire Coverage about 95%
Diameter Over Shield 4.0 mm
Diameter Over Outer Jacket 5.4 mm
Cable Weight 58 kg/km
Tensile Strength 250 N
Minimum Bending Radius, Single Turn 27 mm
Minimum Bending Radius, Repeated 43 mm
Number of bends Minimum (Typical) 50
Installation Temperature Range -250C to + 600C
Operating Temperature Range -400C to + 800C

ELECTRICAL PARAMETERS
Impedance 50 + /-2 Ohm Frequency Attenuation Peak Power
MHz db/100 M Rating
Relative Velocity of propagation 66% 100 13.0 0.21
Capacitance 101 pF/m 200 19.0 0.15
Inductance 0.250 µH/m 300 23.0 0.12
Maximum Operating Frequency 25 GHz 400 27.4 0.11
Cut Off Frequency 33 GHz 450 29.3 0.10
Peak Power Rating 2 KW 600 34.5 0.09
DC Break Down Voltage 2000 V 700 37.8 0.08
Jacket Spark, Volts RMS 2000 V 800 40.8 0.08
Inner Conductor DC Resistance 30 Ohm / km 894 43.5 0.07
Outer Conductor DC Resistance 7 Ohm / km 960 45.4 0.07
Return Loss 800 – 2200 MHz ≥ 20 dB 1000 46.0 0.07
1500 59.1 0.06
1700 63.7 0.05
1800 66.0 0.05
2000 71.0 0.05
2100 72.4 0.05
2200 74.5 0.04
2300 76.5 0.04
2500 82.0 0.04
3000 90.2 0.03
3400 108.1 0.03
5800 137.4 0.03
# All data are typical values