Danced JPRS- SSP PATPUR VIDYUT VITRAN NIGAM LIMITED >< OFFICE OF THE CHIGF ENGINEER COMMERCIAL VIDYUT BHAWAN, JANPATH, JATPUR No. JPD /CE (C)/C./F.4(261)/Pt.1X/D, 5 4) Dt. 4+03'09 QRDER Sub: Installation of Dry/Oil Type Transformers in Residential/Commercial buildings and their testing in Nigam’s Central Testing Laboratory (CTL) prior to installation. As per provisions of the” Indian Electricity Rules-1956” only Dry-type transformer shall be used for installation inside the Residential/Commercial buildings. The relevant provisions under Rule 64(2) (e)(iv) of Indian Electricity Rules-1956 is reproduced hereunder:- “Not withstanding any thing Contained in Rule-64(2)(a) & 64(2)(f)(1i), only dry type transformers shall be used buildings.” To elaborate, following directions are issued:- i) If the distribution transformer is to be installed in a Vou residential/commercial building in an enclosed premises at the Ground Floor, it shall be dry type transformer only. Pai, or Sercrintending Paein-er (AT @ cre) 2b25F 12. 2.09 : sty, a= SBT & Gay "If the distribution transformer is to be installed in a buildin al commereial buslding In the basement of the building or In axflaor ather than Ground ‘floor of the building, it has to:be adry type transformer only. iit) oa however the distribution transformer is to be installed SC&e; Not in an enclosed Premises, it can be Dry or Gil filled Distribution transformer, 1m order to make compliance’ of the provisions as stated above, requesting for new Clectrification/ release of Connections for residential and commercial buildings, the use of Dry -type transformer is Mandatory except in For New connection Based on Discoms and CBIP specification, the requirement of basic electrical al losses, load losses, Percentage impedance etc, to be. complied by the users and checked/verified by the Central Testing Laboratory (CTL) of the Nigam for differént ratings of “Oil Fillea” 11/0.4 KV Distribution transformers. are indicated in Annexure-A, Pa), Annexure-B, Accordingly, following proceidisre 's hereby prescribed for checking of electrical Parameters for different ratings of transformers to be installed by the Applicant’s/ Prospective consumers; - ) ii) ili) iv) v) PH vi) The standard. electrical Darameters of | distcipution transformers should be Informed to the prospective consumer through demand Notice (while issuing Of the Parameters will be checked in the CTL of the Nigam at applicant's cost, ‘ The distribution transformer shall be transported to the by the consumer on recommendations of the concerned AEn (O&™), The testing fee shai be deposited by the consumer in the office of Accounts Officer MM), Jaipur Discom,Old Power House, Jaipur, The testing of the transformer will be done at the CTL and after testing the test report shall be forwarded by CTL to the concerned AEn (O&M) and the consumer. The tested transformer is to be delivered to the concerned AEn (O&M) by CTL, Jaipur. P-3/, Zesting Fee for transfarmer for tests to be carried out at Sentral Testing Laboratory (CTL) i s. ] ‘Name of items Particulars of | Testing tharges in Rs. (Service Tax ] No. test extra) up to calendar year 2009 i 11/0.4 KV Distribution | 7) No load test Rs. 5,290/- 11) Full load test | Transformer up to 250 KVA | [Full oad test |2 ]11/0.4~ kV Bistributior 1) No load test Rs. 7,935/- | ii} Fall Toad test __| Transformer above 250 kya |) Fal impedance | 3 [33/11 KV Power Transformer] ) No load test Rs. 19,838/- S'MVA rating Hl) Full toad test l 3.15 MVA rating iil) % impedance It is also to clarify that in case the calculated rating of the transformer(s) to be used by the applicant happens to be different, the nearest of higher or lower rating available in annexure will be allowed and chosen. This. is in supersession of earlier Order’No.2343 dt.23.9. issued on the subject. Encl: Annexure -A&B A/mariyamma/CE(C)2 08 (JPR5-498) By order, 43009 (N.M, Sareen) Chief Engineer (CommI.) PW ee Annexure-a Basic Electricals parameters for Oil-fled Transformers fe @ 11/0.4 kVA class TRS 537 Maximum [Maximum Full [9 oC reensence at |” Magnetizing cuentas ¥ oF full noload | load Cu. Loss | 75 (tolerance + load current at 75°C At 100% rated |__(Watts) For Distribution Transfor i. (i) Winding-50 °c (i) Top oil-40 °c (8) For Power Transformers Le, 33 KV class (i) Winding-50 °c (ii) Top oil-as » 2. Thickness of Transformers Tank (rolling tolerance as per Is) (A) For Distritution Transformers (1) Top & Bottom: 5.00 mrs (il) Sides : 4.00 mm (B) Power Transformers {Top & bottom: 8.00 mm(+2mm for rating more than 5 MVA) Amit Mahou 2\Bhendat ir doe Annexure-B Basic Electricals parameters for Dry-type Transformers ' TPRE-S3z (i) 11/0.4 kVA class ; Rating | Maximum ‘| Maximum full % Impendence at Magnetizing current as % of full | no load | load Cu. Loss | 75 «¢ (tolerance + foad current users at 75°C -10%) At 100% rated |” at 110% rated voltage voltage 5.00 2.5 4.5 | 5.00 2.5 4.5 5.00 2.5 45} 5.00 25 4.5 5.00 2.5 45 5.00 2.0 4.00 5.00 2.0 4.00 5.00 2.0 4.00 5.00 2.0 4.00 5.00 15 3.0 6.25 [ 15 3.0 6.25 [ 15 3.0, 6.25 Tf 15 3.0 | 7.00 1s I 3.0 | 7.00 15 3.0 7.00 1.5 3.0 | 7.00 15 3.0 7.00 1.25 2.5 7.00 =| 1.25 2.5 | 75 efi 3.0 75 oO 75 EX Ea 75 3.0 7.5 2.5 | [ 7.5) 1.25 L 25 ] Note: 1. Max, Permissible temperature rise of winding 115 °c 2. Class of Insulation () Winding conductor: class *¢# (i) Other Insulating material: Class “HW” DAAmit Malhotre-2\Bhandar ji doe y Copy Submitted forwarded to the following tor information and :fecessary action:~ ch. The Director (Finance ), SVVNL, Jaipur (with 45 spare copies), . rector (7 NL, Jaipur, ‘3. The Zonal/Dy. Chiet Engineer ( Zone/Rp), JWNL, Jaipur/kota, 4 The Dy. Chie? Engineer (mm), IVVNL, Jaipur, 5. The ada, Supdt. of Police (Vig), SVVNL, Jaipur. (with 39 Spare Ss. The Chief Personne} Officer, JVVNL, Jaipur. . 7. The Chief Accounts Officer, VVNL, Jaipur. 8. The Dy. chier Engineer / Supdtg. Engineer (Power), R11co, Jaipur, ‘he Sup gineer NL, * ————__ 10. The Secretary , JVVNL, Jaipur, ‘AAO ( » JVANL, Jaipur, 12. The Executive Engineer ( ), IVVNL, . 13. The Executive Engineer ( ), JWWNL, : alongwith 19 pies: for “sending” the same upto re coy The OENS/AROS/ accouporie level under his jurisdiction. The Executive Engineer (Elect. ), 3.D.4./R.H.B., Jaipur. iL, ur, 20, P.s, to Sec; 21. The Public 22. The Media adv; 3 L, : 23. Sr, ccounts Officer (FP-5), AG, Audit, Shed No.14/1 Jaipur, 24, Sr, Accounts Officer (CAW-tnr), AG, Audit, Shea No.4/1, Jaipur, 25. The Asstt, Engineer ( ), IVVNL, 26. The Zonal Commissioner, Ombudsman, tint Secretariat, Near Collectorate, Jaipur. + The Supdtg, Engineer CT & CRP), Jaipur Discom, Jaipur for Putting UP the order on the website cf Discom, le 3 retary (Energy), Govt, of Rajasthan, Jaipur, Relatio, icer, Jaipur, 28, Chief Engineer (Commi) Conn 2 mone on fhe

S-ar putea să vă placă și