Documente Academic
Documente Profesional
Documente Cultură
Calculation of traffic
proportion:
P1=0.71
P2=0.839
P3=0.813
P4=0.737
Design of Rotary with Standard Weaving Length
Weaving length=40m
Width of carriage at entry(e1)=6.5m
Width of carriage at exit=6.5m
Width of non-weaving section(e2)=6.5m
Width of weaving section(w)=10m
Capacity Qp =2661 passenger car units (Pcu) per hour
Design of rotary wit widened road but with manipulated weaving length
Considerations
Use sparingly and as a measure of last resort. Most appropriate over busy, high-
speed highways, railroad tracks, or natural barriers.
Pedestrians will not use if a more direct route is available or if the grade is
relatively flat.
Lighting, drainage, graffiti removal, and security are also major concerns with
underpasses.
Must be wheelchair accessible, which generally results in long ramps on either
end of the overpass.
Underpasses for Doebum Lam
Present subways
Currently there are two underpasses for Doebum Lam. One is located near the
Swimming Pool Junction and the other one is located near the Chhubha Chhu
Circle below Changangkha School. The current situations of these two
underpasses are:
1. The underpasses are not used by the pedestrians
2. The underpasses are not in condition to be used
3. The underpasses are facing water leakage problem from the adjacent drains
present, making the subways slippery and not usable for the general public
4. The underpasses don’t have proper lighting facilities
5. The underpasses are used as toilets by the general public
With all the points keeping in mind, one can conclude that the subways are
facing functional failure.
Reasons for functional failure of these two Underpasses
The pedestrians prefer to cross the road from the part where the separator blocks
are removed. This causes inconvenience for both pedestrians as well as vehicles and
both the parties are prone to inter or intra accidents.
Underpasses situated below the road, seeing at those just gives the pedestrians a
notion, that it is tiresome job to go through them.
The subway is not in a condition to be used.
No proper lighting facilities are provided for these subways, so, it just is
inconvenient to be used at nights.
Comment: The problem for both the vehicles and pedestrians is that, the peak hours
for both of them coincides and level of service is not enjoyed by both of them.
Proposals for the Underpasses to attract Pedestrians
Keeping the subway clean and providing it with lighting facilities.
The walls too need to be renovated and just like any other underpasses; this
underpass too deserves decoration which would be source of attraction for
general public to use the pedestrians. The walls either should be tiled or plastered
in order to look usable.
The floor too needs to be renovated with tiles or marble or any other flooring
material that gives the subway an expensive look.
Proper accessibility should be provided especially for the one situated at the
Swimming Pool Junction.
Thank You