Sunteți pe pagina 1din 1

Chapter 3,5,1

Name Bob Pressure Test Record


Approved by (Top mngmt)
Approved by (Dept mngmt)
Date of Approval
Domingo prada

30/08/007
C A ROIL

CAROIL DRILLING COMPANY BOP PRESSURE TEST RECORD

RIG # DATE OF TEST 13/08/007 TOOLPUSHJULIO CO

ANNULAR: BLIND/SHEAR RAMS: CHOKE MANIFOLD & VALVES UPPER KINSIDE BOP
TYPE SHAFFER TYPE shaffer SL TYPE cameron fcc - f - fb TYPE HYDRILL
SIZE 13 5/8'' SIZE 13 5/8" SIZE 41/16-31/16 SIZE 4 1/4"
PSI RATING 5000 PSI RATING 5000 PSI RATING 10/5 K. PSI RATING 10000
LO TEST 300 PSI LO TEST 500 PSI LO TEST 500 PSI LO TEST 300 PSI
HELD FOR 3 MIN. HELD FOR 5 MIN. HELD FOR 5 MIN. HELD FOR 3 MIN.
HI TEST 4000 PSI HI TEST 3000 PSI HI TEST 300 PSI HI TEST 4000^ PSI
HELD FOR 10 MIN. HELD FOR 10 MIN. HELD FOR 10 MIN. HELD FOR 10 MIN.
TEST # O2 TEST # 2 TEST # 2 TEST # 2
TOP RAM PREVENTER: 3RD RAM PREVENTER: STANDPIPE & VALVES SAFETY VALVE # 1:
TYPE shaffer SL TYPE shaffer SL TYPE GATE TYPE HYDRILL
SIZE 13 5/" SIZE 13 5/8" SIZE 4" SIZE 3 1/2"
PSI RATING 5000 PSI RATING 5000 PSI RATING 5000 PSI RATING 10000
LO TEST 500 PSI LO TEST 500 PSI LO TEST 500 PSI LO TEST 500 PSI
HELD FOR 3 MIN. HELD FOR 5 MIN. HELD FOR 5 MIN. HELD FOR 500 MIN.
HI TEST 3000 PSI HI TEST 3000 PSI HI TEST 3000 PSI HI TEST 3000 PSI
HELD FOR 10 MIN. HELD FOR 10 MIN. HELD FOR 10 MIN. HELD FOR 10 MIN.
TEST # 2 TEST # 2 TEST # 2 TEST # 2
2ND RAM PREVENTER: CHOKE & KILL LINE VALVES ISIDE
LOWER K BOP SAFETY VALVE # 2:
TYPE TYPE cameron F TYPE HYDRILL TYPE
SIZE SIZE 2 1/16-4 1/16 SIZE 3 1/2" SIZE
PSI RATING PSI RATING 10,000 PSI RATING 10,000 PSI RATING
LO TEST PSI LO TEST 500 PSI LO TEST 500 PSI LO TEST PSI
HELD FOR MIN. HELD FOR 5 MIN. HELD FOR 5 MIN. HELD FOR MIN.
HI TEST PSI HI TEST 3000 PSI HI TEST 3000 PSI HI TEST PSI
HELD FOR MIN. HELD FOR 10 MIN. HELD FOR 10 MIN. HELD FOR MIN.
TEST # TEST # 2 TEST # 2 TEST #

IF AUTOMATIC RAM LOCKS TOP RAMS 2ND RAMS 3RD RAMS BLIND/SHEAR RAMS
DATE OF LAST TEST: LOCKED(PSI) 1400 1400 1400
13/08 8 UNLOCK(PSI) 300 300 300

TOP DRIVE: LO TEST PSI FOR MIN. HI TEST PSI FOR MIN.
TEST PLUG: PLUG TESTER. YES CUP TESTER NO
TYPE OF FLUID IN BOP STACK DURING TEST: X WATER WATER MUD: WT.PPG
ACCUMULATOR UNIT PRESSURES DURING TEST:
ACCUMULATOR 3000 PSI. MANIFOLD 1400 PSI. ANNULAR 1100 PSI.
DATE OF LAST BOP TEST: OCTOBER 26 , 1995
LIST ALL REPAIRS TO BOP SYSTEM AS A RESULT OF THIS TEST. ( INCLUDE PART NUMBERS FOR ALL REPLACEMENT PARTS,
RUBBER ASSEMBLIES, SEALS, RAM HEADS, ETC. DO NOT USE PART NUMBERS FROM INVOICES OR SERVICE TICKETS. USE
ONLY NUMBERS STAMPED ON THE PART BODY OR PRINTED ON THE CARTON OR CONTAINER FOR THAT PART. )

COMMENTS:

--RESULTS ON BOP. TEST OK.

CAROIL . SUPT. COMPANY REP. SER. CO. REP

****** RECORD ALL BOP TEST AND RESULTS ON THE IADC DRILLING REPORT******

Rev No:
Date of Revision: 09 March 06 Page 1 / 1