Dry Type Distribution Transformers


250 kVA up to 40,000 kVA
Mission Working with us, you have access to a world-
wide network of factories and facilities serving
ABB is a global leader in power and automati-
you locally with a full range of products and
on technologies that enable utility and industry
solutions. Our warranty provides one ABB qua-
customers to improve performance while
lity and service. Working together gives you ac-
lowering environmental impact.
cess to production facilities using the most up
to date technologies, providing the highest qua-
lity for standard and specialty products as well
Introduction to ABB
as solutions.
ABB is the worlds leading supplier of Distribution
Transformers. We offer:
All technologies (Dry/Liquid)
All standards (IEC, ANSI, etc)
Applications up to 72.5 kV

Facts and figures (approx)


Production facilities around the world: 30
Countries with Sales and Services centers: 140
Number of units produced yearly: 400,000

Quality statement
Our production facilities are ISO 9001/14001
certified. Our aim is to deliver your distribution
transformers fast, on time and conform to your
specifications.

ABB 3
RESIBLOC® -
the clean technology
The Challenge:
Environmental Safety & Security
Environmental protection demands are today
constantly rising. Ever more frequently, dry type
transformers user specifications are focused on
creating minimum environmental contamina-
tion and providing the very lowest flammabili-
ty risks. For this reason, our transformers must
today constantly meet more stringent parameters
with respect to electrical system demands, as
well as more extreme operating conditions. Glass fibre reinforcement
Applications today include: high-rise office and eliminates all risk of cracks
public buildings, nuclear power plants, offshore and provides the highest
petrochemical platforms, and high output mechanical strength
industrial process plants.
Development of many new technologies has
enabled our transformer designers to apply
modern materials with the very latest of pro-
cesses, increasing the transformers durability
while ensuring unprecedented product reliability.
Thermal shock proof
If any of the following demands form part of even at the highest and
your transformer application, then ABB has the lowest temperatures
necessary solution:
No environmental or human
contamination risks
Non-explosive and extreme fire resistance
Heavy loading cycles (from cold starts to
full loading)
High short circuit withstand Smooth surfaces restrict
Exposure to extreme conditions (arctic, dust accumulation
tropic, chemicals, moistures etc)
Harmonic overloading, over-voltage peaks
or variable load factors
Minimum maintenance

Glass fibre and epoxy


The solution: resin encapsulation pre-
RESIBLOC® - the cast resin transformer vents ingress of moisture and
protects against aggressive
For over 30 years, we have produced and sup-
environments
plied cast resin transformers all over the world.
RESIBLOC® transformers answer the need for
a safe, reliable transformer designed to fulfil the
most exacting specification requirements, whilst
providing a non-flammable, environmentally
safe product.
High impulse withstand
The glass fibre reinforced RESIBLOC® transfor- through layer winding,
mer offers an extremely robust and proven de- giving a linear voltage
sign for medium voltage transformer require- distribution
ments, conforming to IEC 60076-11 standards.

4 ABB
Main technical data
Power rating (AN) 250 kVA to 40,000 kVA
Classification acc. to IEC 60076-11
Rated voltage up to 45 kV – Climatic classification C2
– Environmental classification E2
– Fire classification F1

Compact self-supporting
winding in a one-piece
block – optimum to with-
stand short-circuit-forces

Cylindrical cooling-ducts
provide the advantage of op-
timal cooling through the
inner coil

Aluminium or Copper foil


used in LV-winding

High short circuit with-


stand through prepreg resin
impregnated LV-foil winding

Self-extinguishing in the
event of secondary fire or
arcing and no raised danger
potential as no toxic gases
are released

ABB 5
Glass fibre reinforcement -
guarantee against cracks
Pure epoxy resin reinforced with glass fibre
rovings is a material of enormous strength.
Modern winding processes, combined with
electronically controlled winding machinery,
ensure an even distribution of glass fibre rovings
and epoxy resin and the highest precision in
the manufacture of transformer windings. Multi-
spaced ribs, built-in during the winding pro-
cess, integrate the HV and LV windings into a
single compact winding block.

Low voltage windings High voltage windings


In RESIBLOC® transformers either aluminium The cylindrical high voltage windings are wound
or copper foils are used in the low voltage directly on the LV-windings, in a further pro-
winding, with thermal class F prepreg windings duction process.
insulation. From the use of a foil winding, a
The RESIBLOC® transformers’ superior lightning
considerable reduction in axial short circuit for-
impulse voltage withstand results from the linear
ces is obtained.
impulse voltage distribution, obtained through
To raise the space factor on smaller rated trans- use of the layer-winding concept.
formers, the LV-windings are produced using a
Circular, or for larger cross-sections, rectangu-
wire layer winding. LV-windings that are to ope-
lar copper conductor material to insulation class
rate with system voltages higher than 1.1 kV
H is used. The outer encapsulation and the in-
are produced in the same manner as the high
termediate layer winding insulation consist of
voltage windings.
insulation class F glass fibre reinforced epoxy
Whenever necessary to ensure satisfactory resin material, applied during the ROVING-
cooling, the LV-windings are equipped with ad- winding process.
ditionally axial cooling ducts.
The finally completed winding block is cured
under rotation, in purpose designed curing
ovens.

LV aluminium foil winding


with prepreg insulation

6 ABB
Glass fibre rovings Layer insulation with glass fibre cross bandage

HV layer winding

ABB 7
Core & Coils –
Optimal Materials & Design Geometry
The glass fibre portion of approx. 80 %, com- As no casting moulds are used to manufacture
bined with glass fibre cross and radial bracings the RESIBLOC® transformers, customised win-
are introduced during the winding process. dings, built to a customers specification are
Exceptionally powerful winding blocks result, easier produced. The smooth outer surfaces of
with high mechanical strength in both axial and the winding restrict dirt and dust from accu-
radial directions. mulating.
Windings with high short circuit withstand levels By using the block winding principle, both high
and extreme thermal shock stability at highest and low voltage windings are bound together by
and lowest temperature levels result. The risks multi-spaced ribs, forming a single, solid block.
of cracking, resulting from different thermal ex- Any movements resulting from either axial or
pansion coefficients between conducting and radial forces during short circuit are therefore
solid resin insulation materials, are effectively prevented. The block winding principle ensures
prevented for the transformers total lifetime. HV- & LV-winding spacings, vital for voltage
Furthermore, cracking caused under extreme withstand is guaranteed, and will remain un-
operational conditions, i.e. arctic frozen climates changed during short circuit, or transformer
or following surge overloads will never arise. movement.
Multiple cooling channels, located within the
HV-windings of larger rated transformers enable
these to be made as self cooled units (AN). The
glass fibre roving technology makes it possible
to produce the largest windings as a single piece,
due to the exceptionally high mechanical strength
achieved from this form of solid insulation.
The windings are effectively protected against
mechanical and chemical effects, through the
encapsulation with glass fibre reinforced epoxy
resin insulation materials, insensitive to humidity
and practically maintenance free.

RESIBLOC® windings Cross section of RESIBLOC® winding

8 ABB
Core design Mechanical structure
The core design is an important factor for the The RESIBLOC® transformers yoke laminates
quality of any transformer. The core materials are are firmly held together by steel core clamps.
geometrically arranged, and greatly determine the The upper and lower yoke core clamps are
unit’s loss and noise levels. connected through core tie-straps.
Grain oriented transformer sheet core steel is RESIBLOC® transformers are provided with flat
used in the core construction, cut from rolls on rollers, enabling both longitudinal and traver-
the most modern, fully automated core cutting se movement. To raise the transformer, four lif-
machinery and stacked into limb and yoke pack- ting holes are situated in the upper core clamps,
ages. The use of the best space factor and hig- designed for use with a chain or cable, with a
hest dimensional accuracy result in low core lift angle of ≥ 60 °
losses and noise values.
Finish
The limb and yoke core section joints are in-
terleaved and mitred at 45°, creating the optimum The RESIBLOC® transformer frame, core clamps,
conformity of magnetic flux pattern to the etc. are given a final RAL 2000 finish colour.
preferred magnetic flow. The modern step-lap
technology (SLT) creates multiple stepped joints
between the limbs and yoke sections. Every
core is given a protective epoxy resin finish, a
lasting protection against corrosion. The block
windings are firmly braced to the core using
purpose made resin insulation strips.

ABB 9
Tested one by one
Tests Fire safety
Prior to dispatch, every single RESIBLOC® trans- RESIBLOC® transformers can safely be charac-
former undergoes a detailed individual test and terised as hard to ignite or self-extinguishing.
inspection, including all routine tests according Less than 5% of the materials used can burn if
to IEC 60076-11 and VDE 0532. These includes: the transformer is drawn into a normal fire. Tests
have proven that RESIBLOC® transformers ful-
Routine Tests fil the requirements of Fire Behaviour Class F1,
acc. to IEC 60076-11:
Measurement of voltage ratio and check of
phase displacement No toxic gases, and no gases appear other
Separate-source AC withstand voltage test than those present in any normal fire.
(applied voltage) This very favourable fire behaviour is a
Induced AC overvoltage withstand test direct result from the use of approx.
Measurement of no load loss and current 80% glass fibre content in the insulation
Measurement of winding resistance material.
Measurement of impedance voltage, short- The excellent self-extinguishing effect is
circuit impedance and load loss achieved without using any
Partial discharge measurement environmentally undesired halogens.
Function- and insulation test of control wi-
ring, auxiliary operation, tests on on-load
tap changers, where appropriate

Additional type- and special tests can be executed


on request:

Type Tests:
Lightning impulse (LI) test
Temperature-rise test

Special Tests:
Determination of sound levels
Determination of capacitances of
windings to earth and between windings
Measurement of zero-sequence
impedance(s) on three-phase transformers Fire test equipement
Measurement of the harmonics of the
no-load current
Measurement of insulation resistance to
earth of the windings, and between the
windings
Partial discharge measurement for isolated
networks

10 ABB
Deep-freeze temperature test at -60°C
RESIBLOC® transformers have been severely te-
sted at the Department of High-Voltage Dielectric
Testing of Karlsruhe University:
The RESIBLOC ® transformer passed a deep-
freeze temperature storage test at -60°C, whereas
the class C2 according to VDE 0532 part 6 and
IEC 60076-11 requires only -25°C.
Additionally, 3 thermal shock load tests have
been made: 2 tests at double rated current at -
-60°C and a third test with 2.55 times rated cur-
rent, also at -60°C. VDE requires only 1 test to
be made at -25°C. Full IEC 60076-11 routine
tests, a well as a partial discharge test were per-
formed before and afterwards.
These tests prove that the RESIBLOC® transfor-
mers exceed the requirements of VDE 0532 resp.
IEC 60076-11, class C2. Therefore the RESI-
BLOC® is very well suited for operation in arc-
tic conditions and for applications with strongly
variable loads.

t/hours

ABB 11
The precise enclosure for any site
Enclosure protection IP 21 enclosures
Standard RESIBLOC® transformers are supplied Enclosures to the class IP 21 provide entry pro-
as protection class IP 00, i.e. without enclosures. tection against solid objects ≥ 12 mm diameter
Additional enclosure protection to different and dripping water. This enclosure type is sup-
protection classes are possible. plied with grilled base-plate and side-mounted
grills to front and rear, enabling good cooling air-
General design flow.
All enclosures are manufactured using galvanised
IP 23 enclosures
sheet steel, with an optional paint finish on re-
quest. The enclosures use bolt on, lift-off, front The IP 23 enclosures offer more protection than
and rear panels for easiest cable connections the IP 21, with resistance to dripping water up
and reconnection of HV-voltage tappings. Cable to a vertical 60° angle. Outdoor units will need
entry cut-outs are provided in the enclosure additional rain covers over the grills, to avoid any
base-plate. rainwater entry.
To ensure adequate cooling air supply, a space Specially adapted units are available.
must exist between the enclosure base-plate
and the floor. The recommended cooling air
volume is approx. 4m3 per kW per minute of Special enclosures
dissipated heat loss at 75°C operating tempera-
Specially designed enclosures can be provided,
ture.
suitable to individual customer requirements,
i.e.:
Protection class IP X4D provides entry pro-
tection against solid objects > 12mm and
also protects against entry of wire ≥ 1mm.
Additionally, this protection class prevents
the entry of sprayed water from all direc-
tions.
Protection class IP 54 offers - in addition to
IP X4D – complete touch protection and
protection against accumulation of dange-
rous dusts. The enclosure is provided with
a cooler on ratings above 1000 kVA, either
as air-water or air-air cooler.

On request, we will gladly bid enclosures to


other protection classes.

Enclosure IP 23
Enclosures in stainless steel or in other materials
can be provided.

Enclosure IP X4D

12 ABB
Enclosure IP 54 IP 23 enclosure with raincover and OLTC

Special outdoor enclosure

ABB 13
RESIBLOC® - special designs
for special applications
Although the standard design of RESIBLOC® The RESIBLOC® is regularly produced in the
cast resin transformers and regularly manufac- following Special Designs, and used for the
tured enclosures satisfy most of our customers following Special Applications:
needs, special operating or site conditions will
always demand the creation of special designs. – Single phase transformer
– Triple winding/Dual secondary transformer
The flexibility in theRESIBLOC® concept ena-
– Dual HV winding transformer
bles most requirements to be fulfilled. Variations
– Energisation transformer
such as single phase, 3-winding transformers,
– Oven transformer
or transformers with special terminal arrange-
– Rectifier transformer
ments, cable supports, flange connections to
– Auto transformer
match busbar systems, are regularly being dispat-
– Traction transformer
ched to clients worldwide. RESIBLOC® trans-
– OLTC transformer
formers can be supplied with additional equip-
– Railway applications
ment, for example: earthing switches, load or
– Marine: propulsion & distribution
no-load break switches and fuses etc.
– Nuclear energy
– Windmill power
– Mining duty

IP 54 RESIBLOC® transformer with AFAF cooler -


mining application
IP 54 RESIBLOC® transformer with AFWF cooler -
marine application

14 ABB
20 MVA RESIBLOC® transformer
with on load tap changer

RESIBLOC® single phase transformer

LV busbar termination

ABB 15
Overloadable to the limit, without risk
Overload capability
The favourable long time-constants of cast resin
transformer windings allow short-period high
overloads during operation. Full benefit can be
taken from this, when considering the trans-
formers power rating. When prior to the over-
load, the RESIBLOC® transformer is only partially
loaded and/or operated at a lower ambient tem-
perature than it’s design value, the windings
end temperature of 155 °C will not be exceeded
by specific overloads.

Overload protection 2 stage temperature control


High ambient site temperatures, inadequate coo-
ling air-flow and heavy system loads may re-
sult as a transformers thermal overloading. Every
RESIBLOC® transformer should have a tempe-
rature monitoring system installed for maximum
protection and safety.
The typical temperature monitoring system would
be equipped with PT100 sensors and controls all
3 winding phases.

Forced air cooling


RESIBLOC ® transformers can optionally be
equipped with cross-flow cooling fans. These
fans will increase the rated output of the trans-
former by up to 40 % and have low noise levels
and ideal long time control of irregular over-
loads.
Thermal sensors automatically control the fans,
avoiding excessive and unnecessary use of the
cooling fans.

Overload protection schematic

Forced air cooling

16 ABB
Technical data
RESIBLOC® transformers can be supplied with Tolerances, according to IEC:
rated voltages up to 45 kV. The HV-windings
can be supplied with reconnectable tappings, 1 Losses
to function from numerous voltages. a) Total losses
+ 10 % total losses
Tapping range
The standard tapping range is ±2 x 2.5%. Other b) No-load and/or load losses
tapping ranges are available on request. + 15 % of no-load or load losses on
condition that the tolerance for total
Impedance voltage losses are not exceeded.

For impedance voltage values refer to the table 2. Voltage ratio


on page 20. Transformers with other impedance Rated voltage ratio (principal tapping)
values are available on request. the lower of the following values:
a) ± 0.5 % of the obligatory rated value
Connection groups b) a percentage of the obligatory
Standard connection group is either Dyn 5 or voltage ratio which equals ± 1/10 of
Dyn 11. Other vector groups are available. the measured rated impedance
voltage percentage
Temperature rise
3. Impedance voltage (principal tapping)
Standard RESIBLOC® transformers are by de- ± 10 % at rated current
sign restricted to 100 K, the temperature rise
limit of class F according to IEC 60076-11 and 4. Impedance voltage for other tappings
VDE 0532. ± 15 % of agreed value for this tapping

Noise levels 5. No-load current


Noise levels are detailed in the table on page 20, + 30 % of the obligatory no-load
and shown in sound-power levels. These levels current
apply for IP 00 transformers, measured at 1 m
distance. Transformer for 60 Hz
Transformers designed for 50 Hz operation can
also operate on a 60 Hz supply with the
following amendments to the technical data:
Power: approx. 97 %
No-load losses: 80 - 85 %
Load losses: approx. 105 %
Impedance: 115 - 120 %

ABB 17
Service conditions
Maximum temperatures Altitude
Unless otherwise requested, the RESIBLOC ® According to IEC 60076-11 and VDE 0523, part
transformer is designed to meet the maximum 6, a normal height above sea level of 1000 m
temperature limits as defined in the standards (3300 feet) must not be exceeded. For operati-
IEC 60076-11 and VDE 0532, part 6: on at higher altitudes, a special technical de-
sign is necessary to allow for the cooling air
Maximum ambient temperature 40 °C
and the dimensioning of the electrical air insu-
Average of the hottest month 30 °C lation distances.
Average in any one year 20 °C
Humidity and pollution
Standard RESIBLOC® transformers can be used
The RESIBLOC® transformer is designed accor-
in ambient temperatures up to 55 °C, provided
ding to the demands of IEC 60076-11 class E2.
correctly reduced loads are applied. As a guide,
for each 10 °C increased ambient temperature, The RESIBLOC® is for use under extreme service
a 7% load reduction must be observed. Specially conditions, with high humidity levels, frequent
designed, fully loadable units for use in higher condensation and/or pollution and for normal
cooling air conditions are available. outdoor application in proper ventilated
enclosures.
Minimum temperatures
The colder temperatures are of special interest
for the dry type transformers, not only during
transport and storage, but also in service. The
RESIBLOC ® transformer can be placed in
operation at temperatures as low as -60°C, with-
out special considerations. There are no re-
strictions, even after longer periods of low
loading, or lengthy times completely switched-
off. The extreme mechanical strength of the
glass fibre reinforced cast resin roving windings
eliminates any danger of cracking in the win-
dings.

18 ABB
Outline drawing - standard ABB RESIBLOC® transformer IP 00

1 HV terminal
2 LV terminal
3 LV star point
4 Ground earth. Terminal
5 Rating plate
6 Terminal strip
7 Lifting eyes

Outline drawing - standard ABB RESIBLOC® transformer IP 23

1 HV terminal
2 LV terminal
3 LV star point
4 Ground earth. Terminal
5 Rating plate
6 Terminal strip
7 Lifting eyes

ABB 19
D= Roller distance
No-Load loss (W)

Total weight (kg)

Total weight (kg)


L = Length (mm)

W= Width (mm)
L= Length (mm)
H= Height (mm)

H= Height (mm)
Noise level (dB)

W= Width (mm)
Impedance (%)

Load loss (W)

Sound power

Vector group
Power (kVA)

HV / LV (kV)

T = 75° C

IP 00

IP 00

IP 00

IP 00

IP 23

IP 23

IP 23

IP 23

(mm)
Normal no load loss
250 10/0.4 6 690 3400 65 Dyn11 1220 660 1280 810 1510 1120 1660 1220 520
400 10/0.4 6 1000 5000 68 Dyn11 1370 810 1360 1420 1660 1170 1710 1580 670
500 10/0.4 6 1200 5700 69 Dyn11 1410 810 1340 1580 1750 1210 1700 1750 670
630 10/0.4 6 1370 6600 70 Dyn11 1470 810 1400 1810 1820 1210 1750 2000 670
800 10/0.4 6 1700 7700 72 Dyn11 1570 810 1430 2250 1940 1250 1760 2450 670
1000 10/0.4 6 2000 8800 73 Dyn11 1490 890 1700 2530 1680 1180 1950 2750 820
1250 10/0.4 6 2400 10500 75 Dyn11 1700 980 1680 2970 1990 1300 2130 3200 820
1600 10/0.4 6 2800 12700 76 Dyn11 1690 980 1890 3690 2060 1340 2260 3950 820
2000 10/0.4 6 3500 15500 78 Dyn11 1770 1050 2070 4460 2150 1360 2540 4740 820
2500 10/0.4 6 4300 19000 81 Dyn11 1790 1300 2230 5350 2170 1570 2800 5690 1070
3150 10/0.4 6 5200 22600 83 Dyn11 1990 1300 2330 6820 2420 1650 2900 7200 1070
Reduced no load loss
250 10/0.4 6 540 3400 57 Dyn11 1200 660 1260 1290 1480 1140 1650 1440 520
400 10/0.4 6 780 5000 60 Dyn11 1350 810 1360 1570 1660 1250 1730 1750 670
500 10/0.4 6 940 5700 61 Dyn11 1350 810 1440 1800 1660 1230 1810 1980 670
630 10/0.4 6 1100 6600 62 Dyn11 1510 810 1410 2100 1850 1280 1740 2300 670
800 10/0.4 6 1330 7700 64 Dyn11 1630 810 1470 2590 1970 1310 1780 2800 670
1000 10/0.4 6 1500 8800 65 Dyn11 1550 980 1750 3030 1900 1370 2080 3260 820
1250 10/0.4 6 1880 10500 67 Dyn11 1630 980 1940 3540 1960 1350 2370 3800 820
1600 10/0.4 6 2100 12700 68 Dyn11 1750 980 1860 4530 2150 1420 2230 4800 820
2000 10/0.4 6 2750 15500 70 Dyn11 1780 1050 2060 5340 2170 1440 2530 5640 820
2500 10/0.4 6 3000 19000 71 Dyn11 1810 1300 2440 6330 2180 1590 3010 6680 1070
3150 10/0.4 6 3900 22600 73 Dyn11 1940 1300 2450 7160 2330 1630 3020 7530 1070
Normal no load loss
250 20/0.4 6 880 3300 65 Dyn11 1320 710 1560 1360 1740 1340 1940 1570 520
400 20/0.4 6 1200 4800 68 Dyn11 1410 810 1630 1700 1800 1340 2020 1920 670
500 20/0.4 6 1400 6000 69 Dyn11 1410 810 1770 1950 1800 1350 2160 2180 670
630 20/0.4 6 1650 6900 70 Dyn11 1430 810 1790 2160 1830 1390 2180 2410 670
800 20/0.4 6 1900 8100 72 Dyn11 1530 820 1830 2570 1940 1400 2200 2820 670
1000 20/0.4 6 2300 9600 73 Dyn11 1610 980 2000 3030 2040 1420 2450 3310 820
1250 20/0.4 6 2700 11500 75 Dyn11 1730 980 1910 3490 2150 1460 2370 3770 820
1600 20/0.4 6 3100 14000 76 Dyn11 1730 980 2210 4420 2160 1500 2680 4720 820
2000 20/0.4 6 4000 16700 78 Dyn11 1810 1050 2450 5260 2220 1500 2920 5590 820
2500 20/0.4 6 5000 20000 81 Dyn11 1890 1300 2410 6220 2340 1690 2880 6590 1070
3150 20/0.4 6 6000 24000 83 Dyn11 1970 1300 2590 7170 2430 1730 3160 7580 1070
Reduced no load loss
250 20/0.4 6 650 3300 57 Dyn11 1430 720 1600 1730 1820 1360 1990 1950 520
400 20/0.4 6 940 4800 60 Dyn11 1410 810 1630 1920 1790 1370 2010 2140 670
500 20/0.4 6 1100 6000 61 Dyn11 1450 810 1780 2200 1850 1390 2160 2440 670
630 20/0.4 6 1250 6900 62 Dyn11 1470 810 1880 2570 1860 1440 2260 2830 670
800 20/0.4 6 1460 8100 64 Dyn11 1590 830 1910 3330 2000 1480 2300 3610 670
1000 20/0.4 6 1800 9600 65 Dyn11 1670 980 1970 3610 2150 1610 2300 3910 820
1250 20/0.4 6 2080 11500 67 Dyn11 1670 980 2190 4090 2060 1450 2650 4390 820
1600 20/0.4 6 2400 14000 68 Dyn11 1730 980 2320 5010 2130 1410 2790 5320 820
2000 20/0.4 6 3100 16700 70 Dyn11 1830 1050 2460 6140 2250 1510 2930 6480 820
2500 20/0.4 6 3600 20000 71 Dyn11 2010 1300 2660 7680 2430 1560 3130 8070 1070
3150 20/0.4 6 4400 24000 73 Dyn11 2090 1300 2630 8510 2540 1650 3200 8920 1070

Subject to change

ABB 20
Distribution transformers offered by ABB Services offered by
ABB Distribution Transformers
Liquid filled distribution transformers:
- Installation and Commissioning
- up to 72,5 kV - Training
- single phase and three phase - Testing and maintenance
- ground mounted, pole mounted or - Retrofits, Revamping and up-grading
pad mounted - Spare parts procurement
Technical information available from
Dry transformers:
abb.com/distributiontransformers
- Open Wound
- Vacuum Cast Coil
- RESIBLOC® Dry Type Transformers

Transformers for special applications:


- Railway application
- Marine: propulsion and distribution
- Carrier Vessel Nuclear
- Rectifier Transformers
- Variable Speed Drive
- Excitation Transformers
- HVDC Converter
- Transformers for windmills
- Autotransformers
- Grounding/Earthing Transformers
- Neutral Earthing Reactors
- Current Limiting Reactors
- Arc Furnace
- Boostertransformers

21 ABB
Leaflet Ident. no. 1LAC000003 Printed in Germany (10.2004)

ABB Transformers Note:


Power Technologies Division We reserve the right to make technical changes or modify the contents of this document
without prior notice. With regard to purchase orders, the agreed particulars shall prevail.
Affolternstrasse, 44 ABB does not accept any responsibility whatsoever for potential errors or possible lack of
8050 Zurich information in this document.

Switzerland We reserve all rights in this document and in the subject matter and illustrations contained
therein. Any reproduction – in whole or in parts – is forbidden without ABB’s prior written
www.abb.com/transformers consent.
e-Mail: info@abb.com
Copyright© 2003 ABB
All rights reserved.

S-ar putea să vă placă și