2A-41 lost communication to TRU
2A:23 Climate capacities reduced (Check fans and the Fan Control Unit)
2A:9 Power limits exceeded (Related faults: RXOTX 1B:2 TRU faulty need replacement)
Page 2 of 3
RXASP: MO=RXOTG-tg$; (to find the all alarm and reason of block)
IF LOCAL MODE found than try to make REMOTE otherwise
Check the fault code by command
RXMFP:MO=mo$; (to find the exact fault code to make decision that hardware if faulty
or not if hardware is faulty and need replacement then book the fault to ericsson and if
the hardware is not faulty the BLOCK/DEBLOCK to make unit operational )
If any mo not block then check the half rate is on or off
For checking half rate use command
RLDHP: CELL=cell; (DHA=ON)
If DHA not ON use command to on it
RLDHC: CELL=cell, DHA=ON;
If traffic is more than for witch site is configured (as erlang B table ) then increase the
value of half rate by using command
RLDHC: CELL=cell, DTHAMR=100, DTHNAMR=100;
Erlang B table
TRU (Per sector) Traffic that supported on full rate
1 2.2E
2 8.0E
3 14.5E
4 21.4E
5 28.5E
6 35.8E
7 43.1E
8 50.5E
If none of the above case so new BTS is required to release congestion