Sunteți pe pagina 1din 72

Evolution Series

User Manual
General

B4065 Rev. F

This manual is the property of Nera Networks AS. No parts of the manual may be copied, rewritten or distributed to third parties without the
written permission from Nera Networks AS.
In addition to the WEB edition
the manual is available in
paper format
The manual is divided in 5 main parts:

General This part gives a general overview of the Evolution Series equipment

Installation Gives the details on how to install the equipment

Operation Describes how to operate the system with emphasis on the Evolution Series Manager

Maintenance Gives details on maintenance of the equipment

Appendices A collection of frequency plans, alarm lists, technical specifications etc.


Table of Contents

General
Revision History
About this Manual
Legal Information
Intended use of equipment
Declaration of Conformity
Warnings
System Overview
Configuration
IFU Overview
SU Overview
RIU Overview
FAN Overview
LIU El Overview
LIU Opt Overview
LIU 12xE1 Overview
LIU 25xE1 Overview
LIU 8xT1 Overview
LIU 16xT1 Overview
LIU 3xDS3/E3 Overview
Gigabit Ethernet Unit
Overview
DXC Overview
EOW Overview
Handset
64kb/s Overview
Alarm & Control Unit Overview
E1/T1 Wayside Overview
ODU Overview

How to contact Nera


Revision History
Revision Applies to System release Date Amendments
A R1 03-04-2006 Initial version
B R2 03-06-2006 New AUX Units: Engineering Orderwire Unit and 4x64kb/s Unit.
New Frequency plans: U6G, 11G, 18G and 23G.
C R3 13-11-2006 New system Type; XPAND, introduced. New Plug-in Units: LIU 25xE1 and Gigabit Ethernet.
D R3B 15-01-2007 New AUX Unit: Alarm & Control Unit.
New Plug-in Units: LIU 12xE1 and LIU 3xDS3/E3.
Applies to system release R3B
E R4A 02-04-2007 New Plug-in Units: LIU 8xT1 and LIU 16x T1.
Applies to system release R4A
F R4B 30-05-2007 New AUX unit: Wayside Unit
PDH X-connect supported
Applies to system release RB
About this Manual

General
This manual describes the installation, use and maintenance of the Nera Evolution Series equipment.
As the equipment is modular based, a wide range of system configurations are available. Not all configurations are described in
this manual.

Target Group
The manual is intended for use by trained technicians and will not describe basic technical procedures.

Conventions
The following conventions are used to emphasise important statments and increase the readability of this manual.

Tip: Useful information!

Note: Important information

Warning: Special care must be taken


Button: Starts an action

Text box: Description of features and equipment handling


Legal Information
The information in this documentation is subject to change without notice and describes only the product defined in the
introduction of this documentation. This documentation is intended for the use of Nera's customers only for the purposes of
the agreement under which the documentation is submitted, and no part of it may be reproduced or transmitted in any form
or means without the prior written permission of Nera.

The information or statements given in this documentation concerning the suitability, capacity, or performance of the
mentioned hardware or software products cannot be considered binding but shall be defined in the agreement made
between Nera and the customer. However, Nera has made all reasonable efforts to ensure that the instructions contained in
the documentation are adequate and free of material errors and omissions. Nera will, if necessary, explain issues that may
not be covered by the documentation. Nera's liability for any errors in the documentation is limited to the documentary
correction of errors.

NERA WILL NOT BE RESPONSIBLE IN ANY EVENT FOR ERRORS IN THIS DOCUMENTATION OR FOR ANY
DAMAGES, INCIDENTAL OR CONSEQUENTIAL (INCLUDING MONETARY LOSSES), that might arise from the use of this
documentation or the information in it. This documentation and the product it describes are considered protected by
copyright according to the applicable laws.

NERA logo is a registered trademark of Nera ASA. Other product names mentioned in this documentation may be
trademarks of their respective companies, and they are mentioned for identification purposes only.

Copyright © Nera 2005. All rights reserved.


Intended use of equipment
Evolution Series is a point to point microwave radio. It is typically used for interconnection of access points in private
or public networks. It is used both in Ethernet and TDM based networks.

Note! Use of this equipment requires a separate frequency license to be applied for by the operator.

Declaration of Conformity
This section applies to countries who have implemented the R&TTE directive
NFORMAL
•esky NERA Networks AS tímto prohlašuje, že tento Evolution Series je ve shodě se základními požadavky a dalšími p•íslušnými ustanoveními směrnice 1999/5/ES.
Dansk NERA Networks AS erklærer herved, at Evolution Series overholder de væsentlige krav og øvrige relevante krav i direktiv 1999/5/EF.
Deutch Hiermit erklärt NERA Networks AS, dass sich das Gerät Evolution Series in Übereinstimmung mit den grundlegenden Anforderungen und den übrigen einschlägigen
Bestimmungen der Richtlinie 1999/5/EG befindet.
Eesti Käesolevaga kinnitab NERA Networks AS seadme Evolution Series vastavust direktiivi 1999/5/EÜ põhinõuetele ja nimetatud direktiivist tulenevatele teistele asjakohastele
sätetele.
English Hereby, NERA Networks AS, declares that Evolution Series is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC.
Español Por medio de la presente NERA Networks AS declara que el Evolution Series cumple con los requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de
la
Ελληνικ• ΜΕ ΤΗΝ ΠΑΡΟΥΣΑ NERA Networks AS ∆ΗΛΩΝΕΙ ΟΤΙ Evolution Series ΣΥΜΜΟΡΦΩΝΕΤΑΙ ΠΡΟΣ ΤΙΣ ΟΥΣΙΩ∆ΕΙΣ ΑΠΑΙΤΗΣΕΙΣ ΚΑΙ ΤΙΣ ΛΟΙΠΕΣ ΣΧΕΤΙΚΕΣ ∆ΙΑΤΑΞΕΙΣ
ΤΗS Ο∆ΗGΙΑΣ 1999/5/ΕΚ.
Français Par la présente NERA Networks AS déclare que l'appareil Evolution Series est conforme aux exigences essentielles et aux autres dispositions pertinentes de la directive
1999/5/CE.
Italiano Con la presente NERA Networks AS dichiara che questo Evolution Series è conforme ai requisiti essenziali ed alle altre disposizioni pertinenti stabilite dalla direttiva 1999/5/CE.
Latviski Ar šo NERA Networks AS deklarē, ka Evolution Series atbilst Direktīvas 1999/5/EK būtiskajām prasībām un citiem ar to saistītajiem noteikumiem.
Lietuvi• Šiuo NERA Networks AS deklaruoja, kad šis Evolution Series atitinka esminius reikalavimus ir kitas 1999/5/EB Direktyvos nuostatas.
Nederlands Hierbij verklaart NERA Networks AS dat het toestel Evolution Series in overeenstemming is met de essentiële eisen en de andere relevante bepalingen van richtlijn 1999/5/EG.
Malti Hawnhekk, NERA Networks AS, jiddikjara li dan Evolution Series jikkonforma mal-ħti•ijiet essenzjali u ma provvedimenti oħrajn relevanti li hemm fid-Dirrettiva 1999/5/EC.
Magyar Alulírott, NERA Networks AS nyilatkozom, hogy a Evolution Series megfelel a vonatkozó alapvetõ követelményeknek és az 1999/5/EC irányelv egyéb elõírásainak.
Polski Niniejszym NERA Networks AS o•wiadcza, ze Evolution Series jest zgodny z zasadniczymi wymogami oraz pozostałymi stosownymi postanowieniami Dyrektywy 1999/5/EC.
Português NERA Networks AS declara que Evolution Series está conforme com os requisitos essenciais e outras disposições da Directiva 1999/5/CE.
Slovensko NERA Networks AS izjavlja, da je ta Evolution Series v skladu z bistvenimi zahtevami in ostalimi relevantnimi dolo•ili direktive 1999/5/ES.
Slovensky NERA Networks AS týmto vyhlasuje, že Evolution Series sp••a základné požiadavky a všetky príslušné ustanovenia Smernice 1999/5/ES.
Suomi NERA Networks AS vakuuttaa täten että Evolution Series tyyppinen laite on direktiivin 1999/5/EY oleellisten vaatimusten ja sitä koskevien direktiivin muiden ehtojen mukainen.
Svenska Härmed intygar NERA Networks AS att Evolution Series står i överensstämmelse med de väsentliga egenskapskrav och övriga relevanta bestämmelser som framgår av
direktiv 1999/5/EG.
Íslenska Hér með lýsir NERA Networks AS yfir því að Evolution Series er í samræmi við grunnkröfur og aðrar kröfur, sem gerðar eru í tilskipun 1999/5/EC.
Norsk NERA Networks AS erklærer herved at utstyret Evolution Series er i samsvar med de grunnleggende krav og øvrige relevante krav i direktiv 1999/5/EF.
WARNINGS!

High Frequency Electromagnetic Fields

Exposure to strong high frequency electromagnetic fields may cause thermal damage to
personnel. The eye (cornea and lens) is easily exposed.

Any unnecessary exposure is undesirable and should be avoided.

In radio-relay communication installations, orderly setup for normal operation, the general RF
radiation level will be well below the safety limit.

In the antennas and directly in front of them the RF intensity normally will exceed the danger
level, within limited portions of space.

Dangerous radiation may be found in the neighbourhood of open waveguide flanges or horns
where the power is radiated into space.

To avoid dangerous radiation the following precautions must be taken:

❍ During work within and close to the front of the antenna; make sure that transmitters will
remain turned off.

❍ Before opening coaxial - or waveguide connectors carrying RF power, turn off


transmitters.

❍ Consider any incidentally open RF connector as carrying power, until otherwise proved.
Do not look into coaxial connectors at closer than reading distance (30 cm). Do not look into an open
waveguide unless you are absolutely sure that the power is turned off.
ESD

This equipment contains components which are sensitive to "ESD" (Electro Static Discharge).

It is therefore essential that whenever disassembling the equipment and/or handling PC boards,
special precautions to avoid ESD have to be made.

These precautions include personnel grounding, grounding of work bench, grounding of tools
and instruments as well as transport and storage in special antistatic bags and boxes.
Laser

CAUTION
Use of controls or adjustments or performance of procedures other than those specified herein may result in
hazardous radiation exposure.

The optical interface must only be serviced by qualified personnel, who are aware of the
hazards involved to repair laser products.

When handling laser products the following precautions must be taken:

❍ Never look directly into an open connector or optical cable

❍ Before disconnecting an optical cable from the optical transmitter, the power should be
switched off. If this is not possible, the cable must be disconnected from the transmitter
before it is disconnected from the receiver.

❍ When the cable is reconnected it must be connected to the receiver before it is


connected to the transmitter.
EARTHING

This equipment has a connection between the earthed conductor of the d.c. supply circuit and
the earthing conductor.

NOTE!
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and
used in accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at his own
expense.
System Overview
Introduction
The Evolution Series microwave radio is designed to transmit data rates from about 6 Mb/s to 600Mb/s, in the frequency bands 5 GHz to 38
GHz. The configuration of capacity and modulation is software configurable, giving an optimal balance between system gain and spectral
efficiency.

Available interfaces are: E1, T1, E3, DS3, STM-1/OC-3, STM-4/OC12, 100BASE-TX, Gigabit Ethernet.

The Evolution Series products can be configured in two different modes, selected by the SW license.

The METRO mode

● 155 Mb/s, 311Mb/s and 622 Mb/s transmission capacity


● Configurations up to 3+1/4+0
● CCDP configuration with XPIC
● 28, 40 and 55/56 MHz BW
● Options for embedded ADM mux / X-connect
● TDM traffic : 63xE1, 3xE3/DS3, 64xT1
● Advanced Ethernet : 4xFE and 1xGbE with QoS, nxVC-12(VT1.5), nxVC-3(STS-1) or nxVC-4(STS-3-3c) mapping
● Traffic Node with 4 radio directions, SNCP with Ring, Chain, Star or Mesh topology

The XPAND mode (ETSI)

● Scalable 8, 16, 32, 40, 80, 100, 150 Mb/s transmission capacity
● 7, 14 and 28 MHz BW
● Scalable TDM/Ethernet mix (step of 2Mb/s)
● 4, 8, 16, 20, 40, 50, 75 E1 capacity
● Ethernet 1xFE, scalable with 2 Mbit/s granularity
● Ring protection for E1s, based on SNCP
The XPAND mode (ANSI)

● Scalable 6, 12, 25, 50, 100, 125, 150 Mb/s transmission capacity
● 5, 10, 20 and 30 MHz BW
● Scalable TDM/Ethernet mix (step of 1.5Mb/s)
● 4, 8, 16, 32, 64, 80, 96 T1 capacity
● Ethernet 1xFE, 1.5 Mbit/s granularity
● Ring protection for T1s, based on SNCP

Features
The ODU can be mounted directly on the antenna, both in unprotected and protected configurations. The ODU can also be mounted on the
antenna pole, using a short flexible waveguide to the antenna.

The Universal IFU can easily be expanded from a single channel system up to a traffic node handling up to 8 ODUs. The Universal IFU
contains the line interface, baseband processing and multiplexing, management and radio interfaces.

The optional embedded ADM/DXC function provides multiplexing for user traffic into the STM-1/OC-3 signal. In traffic node systems, the
digital cross connect (DXC) routes the user traffic between the various link directions without the need for cabling or external multiplexers.
Chain, ring, star and mesh topologies are supported, with individual choice of unprotected or protected (SNCP) traffic circuits. The
multiplexer supports a mix of traffic types, such as E1, T1, E3, DS3 and Ethernet.

The equipment configuration, licences and the operating software version, can be stored on the memory key available for plug-in, at the
front of the equipment or downloaded to a computer. When a new Supervisory Unit is inserted, the equipment configuration can then easily
be restored to the radio equipment.

System description
The Evolution Series microwave radio system comprises an indoor part (Universal IFU), and an outdoor part (ODU) and an antenna. The
Universal IFU and ODU are interconnected using a coaxial cable which carries the transmit and receive user traffic, management
communication between the Universal IFU and ODU, and the power supply to the ODU. In protected configurations, two cables are used;
one for each ODU.

Interface Unit (IFU) description


The Evolution Series Universal IFU is a 1RU high modular unit, containing 9 plug-in slots for various modules. The modular architecture
with plug-in slots enables a high degree of flexibility, easy upgrading/changing configurations and maintenance.
Interface Unit (IFU) description
The Evolution Series Universal IFU is a 1RU high modular unit, containing 9 plug-in slots for various modules. The modular architecture
with plug-in slots enables a high degree of flexibility, easy upgrading/changing configurations and maintenance.

The Universal IFU Basic Frame is common in all configurations and up to four IFU frames can be stacked together by an IFU connection
panel.

● When an SU is part of the IFU frame, it will always occupy slot 1. The Supervisory Unit is handling the configuration of all the system
units as well as reporting system status to the NMS system.
● Slot 6 houses the FAN unit, handling the ventilation and temperature management of the IFU frame.
● Slot 2and 3 house the various user traffic interfaces and optional DXC unit. The PDH and Ethernet traffic interfaces are full height
and cover the upper Aux/Serv. position as well.
● Slot 4 and 5 house the RIU unit(s). The RIU unit provides connection to the ODU and supplies power to the IFU Basic Frame with
plug-in units and the ODU. If the DXC unit is used, slot 4 and 5 can be used for traffic interfaces as well.
● Slot 7-9 house any Auxiliary or Service Channel units, such as Alarm Unit, Wayside Traffic Unit, 64 kb/s Data Channels unit and
EOW unit.

All units can be replaced in the field. Non traffic carrying units can be replaced without interrupting the service.

OutDoor Unit (ODU) description


The ODU hardware is capacity and modulation independent. It consists of a transceiver and a diplexer. The transceiver is tuneable over the
whole frequency band, both high and low part. The diplexer determines the sub-band coverage. The ODU may be mounted directly to the
antenna. In HSB and 1+1/2+0 configurations an RF-coupler is used when connecting the ODUs to a single antenna interface. A pole
mount interface is also available.

Configuration examples
Configuration

The Evolution Series equipment can be arranged in various system configurations by means of plug-in units and software licensing. The
examples below show systems without the optional AUX plug-in units.
Select one of the configuration examples:

METRO
1+0 (Unprotected)
1+0 Add-Drop Repeater w/Cross Connect
1+1 (Hot Standby)
1+1 (Hot Standby) - Dual Baseband
1+1 (Hot Standby) - Dual Antenna/Space Diversity
1+1 Frequency Diversity
1+1 Frequency Diversity - Dual Polarization
2+0 Dual Frequency - Single Polarization (DF-SP)
2+0 Single Frequency - Dual Polarization (SF-DP/CCDP)

XPAND
1+0 (Unprotected)
1+1 (Hot Standby)
1+1 (Hot Standby) - Dual Antenna/Space Diversity
1+1 Frequency Diversity
1+1 Frequency Diversity - Dual Polarization
Legend
ALM External alarm input/output
AUX Auxiliary function plug-in units
EMF Embedded Management Functions
EOW Engineering Order Wire
LAN Local Area Network port (10/100BASE-TX Ethernet)
LIU Line Interface Unit (plug-in unit)
RIU Radio Interface Unit (plug-in unit)
PWR Power Supply
SERV Service function (plug-in unit)
SU Supervisory (plug-in unit)
USB Universal Serial Bus
XCVR Transmitter/Receiver
Interface Unit (IFU) overview
The IFU is modular based and can be configured in different ways by means of plug-in units.

By clicking on a unit in the table below, possible slot positions are indicated in the figure above.
Legal slot positions for different configurations are defined by the Housekeeping wizard.
To learn more about the different units; click on the unit name in the table below.

Note! In IFU configurations using DXC Unit and one RIU, slot 4 and 5 can be used for a plug-in interface.

Note! Line Interface units operating with traffic rates > 155 Mb/s, must be placed inn IFU Slot 3.

Line Interface Units Auxiliary Units


LIU Electrical EOW overview
SU overview
overview

64kb/s overview
LIU Optical overview
RIU overview Alarm & Ctrl Unit
LIU 12xE1 overview overview
LIU 8xT1 overview E1/T1 Wayside
overview
PWIU overview LIU 25xE1 overview
LIU 16xT1 overview

LIU 3xDS3/E3
overview
Gigabit Ethernet Unit
FAN overview
overview

DXC Unit overview

One IFU is capable of handling radio systems for 1+0, 1+1, HSB and 2+0 channel arrangements. Larger systems are implemented by
interconnecting IFUs using the expansion port on the back of the IFU and a sub-rack. A total of 4 IFUs and 1 DXC Frame can be stacked and
interconnected. Each IFU and DXC frame is 1U (Unit) high, and can be mounted in both an ETSI and a 19” rack solution as well as standalone.
Supervisory Unit overview

The SU is responsible for configuration and alarm collecting from all the boards in one IFU system. The maximum IFU system may
consist of 5 IFUs that can be controlled from only one SU located in an arbitrary IFU slot. The SU communicates with all boards and
functions needing SU awareness.

Connectors
USB
The USB device connector (USB type B connector) is used to open a text based console interface to the SU. This interface can be used
for basic SU configuration, for instance setting the IP address. The USB device interface complies with USB v1.1

The USB host connector (USB type A connector) can be used for connecting a USB disk on key, to perform software update. This host
connector can also be used as a RS232 interface using a USB to RS232 converter. The USB host interface complies with USB Rev 2.0
full-speed (12Mbit/s).

Ethernet
The Ethernet Port A (ETH1) is the SU management interface port. The Web server, FTP, SNMP and Telnet server are available from
this port.

The Ethernet Port B (ETH2) usage is configuration dependent:


● When the SU is configured for 100/10 Mbit/s Ethernet over the radio hop, port B is the physical interface for this connection

● Else port B is equivalent with port A. Port A and Port B together with the SU CPU form a 3-port Ethernet switch

See Evolution Manager for setup of the Supervisory Unit


Radio Interface Unit overview

The Radio Interface Unit is used for interconnection between the IFU and Radio
The RIU is supplied with -48V DC via the power connector. -48V DC is then fed to the radio and to the IFU. Short circuit and over
voltage protection for the radio is placed in the RIU. The Short circuit and over voltage protection for the IFU is placed on the mother
board.
The IFU has two RIU slots.

See Evolution Manager for setup of the Radio Interface Unit


Power Interface Unit overview

The Power Interface Unit is used as power supply for IFUs where a Radio Interface Unit is not required.
Line Interface Electrical STM-1/STS-3 Unit overview

The Line Interface Electrical STM-1/STS-3 Unit has a CMI encoded 155 Mb/s customer interface.
Electrical interface is according to ITU-T Rec. G.703, ANSI T1.102 and Telecordia GR-253-CORE.
Jitter Performance is compliant with ANSI T1.105.03, ITU-T G.825 and Telecordia GR-253-CORE.
Some of the characteristic parameters of this interface are given below:
Bitrate: 155.520 Mb/s ± 20 ppm
Line code: CMI
Impedance: 75 Ω unbalanced
Return loss (8 MHz to 240 MHz): ≥ 15 dB
Pulse amplitude: 1.0 V ± 0.1 V
Maximum attenuation of input signal at 78 MHz: 12.7 dB
Connector type: DIN47297; 1.0/2.3mm

See Evolution Manager for setup of the Line Interface Unit


Line Interface Optical STM-1/OC-3 Unit overview

The Line Interface Optical STM-1/OC-3 unit is delivered in the following versions:

Line Interface Unit Optical SFP S-1.1/OC-3 IR-1 LIU S-1.1/OC-3 IR-1

Line Interface Unit Optical SFP OC-3 SR-0 LIU OC-3 SR-0

Line Interface Unit Optical SFP L-1.1/OC-3 LR-1 LIU L-1.1/OC-3 LR-1

Line Interface Unit Optical SFP L-1.2/OC-3 LR-2 LIU L-1.2/OC-3 LR-2
LIU S-1.1/OC-3 IR-1
155Mb/s (OC-3/STM-1) Intermediate Reach 1310 nm Single Mode Optical Interface Unit. Transmission target distance is approximately
15 km according to ITU-T G.957.

The Optical Line Interface Unit has a 155.520 Mb/s (OC-3/STM-1) customer interface, according to ITU-T recommendation G.957 and
ANSI recommendation T1.105.06-2002.

In the receive direction, the optical LIU receives a 155.52 Mb/s NRZ encoded optical signal and converts it to an electrical NRZ signal.

In the transmit direction, the LIU receives a STM-1 framed signal and converts it to a NRZ-encoded optical signal.

Warning! The optical interface plugin module (SFP) is an integrated part of the Optical Line Interface Unit and has been tested to comply with Nera
Networks recommendations. The module is not intended for field replacement.

See Evolution Manager for setup of the LIU Optical Unit


Line Interface 12xE1 Unit overview

The 12xE1 Intfc Unit contains 12 x E1 electrical interfaces, according to the ITU-T Rec; G.703

Connector type: 50 positions Amplimite .050 series


Connector Channel no. and Colour code for cable
Pin no. Signal type pair
1A Ch 1 out P Blue/ 15A Ch 8 out P Brown
26A Ch 1 out N White 40A Ch 8 out N Yellow
2A Ch 1 in P Orange/ 16A Ch 8 in P Blue/
27A Ch 1 in N White 41A Ch 8 in N Red
3A Ch 2 out P Green/ 17A Ch 9 out P Orange/
28A Ch 2 out N White 42A Ch 9 out N Red
4A Ch 2 in P Gray/ 18A Ch 9 in P Green/
29A Ch 2 in N White 43A Ch 9 in N Red
5A Ch 3 out P Brown/ 19A Ch 10 out P Gray/
30A Ch 3 out N White 44A Ch 10 out N Red
6A Ch 3 in P Blue/ 20A Ch 10 in P Brown/
31A Ch 3 in N Turquoise 45A Ch 10 in N Red
7A Ch 4 out P Orange/ 21A Ch 11 out P Blue/
32A Ch 4 out N Turquoise 46A Ch 11 out N Black
8A Ch 4 in P Green 22A Ch 11 in P Orange/
33A Ch 4 in N Turquoise 47A Ch 11 in N Black
9A Ch 5 out P Gray 23A Ch 12 out P Green/
34A Ch 5 out N Turquoise 48A Ch 12 out N Black
10A Ch 5 in P Brown 24A Ch 12 in P Gray/
35A Ch 5 in N Turquoise 49A Ch 12 in N Black
11A Ch 6 out P Blue/ 25A Not used Brown/
36A Ch 6 out N Yellow 50A Not used Black
12A Ch 6 in P Orange/
37A Ch 6 in N Yellow
13A Ch 7 out P Green See Evolution Manager for setup of the LIU 12xE1 Unit
38A Ch 7 out N Yellow
14A Ch 7 in P Gray
39A Ch 7 in N Yellow
Line Interface 25xE1 Unit overview

The 25xE1 Intfc Unit contains 25 x E1 electrical interfaces, according to the ITU-T Rec; G.703

Connector type: 2x50 positions Amplimite .050 series


Connector Channel no. and Colour code for Connector Channel no. and Colour code for
Pin no. Signal type cable pair Pin no. Signal type cable pair
1A Ch 1 out P Blue/ 1B Ch 13 out P Blue/
26A Ch 1 out N White 26B Ch 13 out N White
2A Ch 1 in P Orange/ 2B Ch 13 in P Orange/
27A Ch 1 in N White 27B Ch 13 in N White
3A Ch 2 out P Green/ 3B Ch 14 out P Green/
28A Ch 2 out N White 28B Ch 14 out N White
4A Ch 2 in P Gray/ 4B Ch 14 in P Gray/
29A Ch 2 in N White 29B Ch 14 in N White
5A Ch 3 out P Brown/ 5B Ch 15 out P Brown/
30A Ch 3 out N White 30B Ch 15 out N White
6A Ch 3 in P Blue/ 6B Ch 15 in P Blue/
31A Ch 3 in N Turquoise 31B Ch 15 in N Turquoise
7A Ch 4 out P Orange/ 7B Ch 16 out P Orange/
32A Ch 4 out N Turquoise 32B Ch 16 out N Turquoise
8A Ch 4 in P Green 8B Ch 16 in P Green
33A Ch 4 in N Turquoise 33B Ch 16 in N Turquoise
9A Ch 5 out P Gray 9B Ch 17 out P Gray
34A Ch 5 out N Turquoise 34B Ch 17 out N Turquoise
10A Ch 5 in P Brown 10B Ch 17 in P Brown
35A Ch 5 in N Turquoise 35B Ch 17 in N Turquoise
11A Ch 6 out P Blue/ 11B Ch 18 out P Blue/
36A Ch 6 out N Yellow 36B Ch 18 out N Yellow
12A Ch 6 in P Orange/ 12B Ch 18 in P Orange/
37A Ch 6 in N Yellow 37B Ch 18 in N Yellow
13A Ch 7 out P Green 13B Ch 19 out P Green
38A Ch 7 out N Yellow 38B Ch 19 out N Yellow
14A Ch 7 in P Gray 14B Ch 19 in P Gray
39A Ch 7 in N Yellow 39B Ch 19 in N Yellow
15A Ch 8 out P Brown 15B Ch 20 out P Brown
40A Ch 8 out N Yellow 40B Ch 20 out N Yellow
16A Ch 8 in P Blue/ 16B Ch 20 in P Blue/
41A Ch 8 in N Red 41B Ch 20 in N Red
17A Ch 9 out P Orange/ 17B Ch 21 out P Orange/
42A Ch 9 out N Red 42B Ch 21 out N Red
18A Ch 9 in P Green/ 18B Ch 21 in P Green/
43A Ch 9 in N Red 43B Ch 21 in N Red
19A Ch 10 out P Gray/ 19B Ch 22 out P Gray/
44A Ch 10 out N Red 44B Ch 22 out N Red
20A Ch 10 in P Brown/ 20B Ch 22 in P Brown/
45A Ch 10 in N Red 45B Ch 22 in N Red
21A Ch 11 out P Blue/ 21B Ch 23 out P Blue/
46A Ch 11 out N Black 46B Ch 23 out N Black
22A Ch 11 in P Orange/ 22B Ch 23 in P Orange/
47A Ch 11 in N Black 47B Ch 23 in N Black
23A Ch 12 out P Green/ 23B Ch 24 out P Green/
48A Ch 12 out N Black 48B Ch 24 out N Black
24A Ch 12 in P Gray/ 24B Ch 24 in P Gray/
49A Ch 12 in N Black 49B Ch 24 in N Black
25A Ch 25 out P Brown/ 25B Ch 25 in P Brown/
50A Ch 25 out N Black 50B Ch 25 in N Black

See Evolution Manager for setup of the LIU 25xE1 Unit


Line Interface 8xT1 Unit overview

Return to IFU overview

The 8xT1 Intfc Unit contains 8 x T1 electrical interfaces, according to the ANSI Rec; T1.102

Connector type: 50 positions Amplimite .050 series

Connector Channel no. and Colour code for cable


Pin no. Signal type pair
1A Ch 1 out P Blue/
26A Ch 1 out N White 19A Not used Gray/
2A Ch 1 in P Orange/ 44A Not used Red
27A Ch 1 in N White 20A Not used Brown/
3A Ch 2 out P Green/ 45A Not used Red
28A Ch 2 out N White 21A Not used Blue/
4A Ch 2 in P Gray/ 46A Not used Black
29A Ch 2 in N White 22A Not used Orange/
5A Ch 3 out P Brown/ 47A Not used Black
30A Ch 3 out N White 23A Not used Green/
6A Ch 3 in P Blue/ 48A Not used Black
31A Ch 3 in N Turquoise 24A Not used Gray/
7A Ch 4 out P Orange/ 49A Not used Black
32A Ch 4 out N Turquoise 25A Not used Brown/
8A Ch 4 in P Green 50A Not used Black
33A Ch 4 in N Turquoise
9A Ch 5 out P Gray
34A Ch 5 out N Turquoise See Evolution Manager for setup of the LIU 8xT1 Unit
10A Ch 5 in P Brown
35A Ch 5 in N Turquoise
11A Ch 6 out P Blue/
36A Ch 6 out N Yellow
12A Ch 6 in P Orange/
37A Ch 6 in N Yellow
13A Ch 7 out P Green
38A Ch 7 out N Yellow
14A Ch 7 in P Gray
39A Ch 7 in N Yellow
15A Ch 8 out P Brown
40A Ch 8 out N Yellow
16A Ch 8 in P Blue/
41A Ch 8 in N Red
17A Not used Orange/
42A Not used Red
18A Not used Green/
43A Not used Red
Line Interface 16xT1 Unit overview

Return to IFU overview

The 16xT1 Intfc Unit contains 16 x T1 electrical interfaces, according to the ANSI Rec; T1.102

Connector type: 2x50 positions Amplimite .050 series


Connector Channel no. and Colour code for Connector Channel no. and Colour code for
Pin no. Signal type cable pair Pin no. Signal type cable pair
1A Ch 1 out P Blue/ 1B Ch 13 out P Blue/
26A Ch 1 out N White 26B Ch 13 out N White
2A Ch 1 in P Orange/ 2B Ch 13 in P Orange/
27A Ch 1 in N White 27B Ch 13 in N White
3A Ch 2 out P Green/ 3B Ch 14 out P Green/
28A Ch 2 out N White 28B Ch 14 out N White
4A Ch 2 in P Gray/ 4B Ch 14 in P Gray/
29A Ch 2 in N White 29B Ch 14 in N White
5A Ch 3 out P Brown/ 5B Ch 15 out P Brown/
30A Ch 3 out N White 30B Ch 15 out N White
6A Ch 3 in P Blue/ 6B Ch 15 in P Blue/
31A Ch 3 in N Turquoise 31B Ch 15 in N Turquoise
7A Ch 4 out P Orange/ 7B Ch 16 out P Orange/
32A Ch 4 out N Turquoise 32B Ch 16 out N Turquoise
8A Ch 4 in P Green 8B Ch 16 in P Green
33A Ch 4 in N Turquoise 33B Ch 16 in N Turquoise
9A Ch 5 out P Gray 9B Not used Gray
34A Ch 5 out N Turquoise 34B Not used Turquoise
10A Ch 5 in P Brown 10B Not used Brown
35A Ch 5 in N Turquoise 35B Not used Turquoise
11A Ch 6 out P Blue/ 11B Not used Blue/
36A Ch 6 out N Yellow 36B Not used Yellow
12A Ch 6 in P Orange/ 12B Not used Orange/
37A Ch 6 in N Yellow 37B Not used Yellow
13A Ch 7 out P Green 13B Not used Green
38A Ch 7 out N Yellow 38B Not used Yellow
14A Ch 7 in P Gray 14B Not used Gray
39A Ch 7 in N Yellow 39B Not used Yellow
15A Ch 8 out P Brown 15B Not used Brown
40A Ch 8 out N Yellow 40B Not used Yellow
16A Ch 8 in P Blue/ 16B Not used Blue/
41A Ch 8 in N Red 41B Not used Red
17A Ch 9 out P Orange/ 17B Not used Orange/
42A Ch 9 out N Red 42B Not used Red
18A Ch 9 in P Green/ 18B Not used Green/
43A Ch 9 in N Red 43B Not used Red
19A Ch 10 out P Gray/ 19B Not used Gray/
44A Ch 10 out N Red 44B Not used Red
20A Ch 10 in P Brown/ 20B Not used Brown/
45A Ch 10 in N Red 45B Not used Red
21A Ch 11 out P Blue/ 21B Not used Blue/
46A Ch 11 out N Black 46B Not used Black
22A Ch 11 in P Orange/ 22B Not used Orange/
47A Ch 11 in N Black 47B Not used Black
23A Ch 12 out P Green/ 23B Not used Green/
48A Ch 12 out N Black 48B Not used Black
24A Ch 12 in P Gray/ 24B Not used Gray/
49A Ch 12 in N Black 49B Not used Black
25A Not used Brown/ 25B Not used Brown/
50A Not used Black 50B Not used Black

See Evolution Manager for setup of the LIU 16xT1 Unit


EOW Unit overview

The EOW (Engineering Order Wire) Unit includes 4 ports (RJ45):

● Port1; Service Telephone handset. Selective call (00 to 99) or collective call (*)
● Port2; 64kb/s, G.703 Co-directional / Analog interface
● Port3; 64kb/s, G.703 Co-directional / HDLC / Analog interface
● Port4; 4Wire transformer isolated interface

1......8

Pin no. PORT1 PORT2 PORT3 PORT4


1 NC Ch1_64kb/s_ codir._OutA Ch2_64kb/s-codir._OutA Call_Out
2 NC Ch1_64kb/s_ codir._OutB Ch2_64kb/s-codir._OutB NC
3 NC Ch1_64kb/s_ codir._InpA Ch2_64kb/s-codir._InpA Call_Inp
4 Tel_Ring OE1- OutA OE2- OutA 4Wire- OutA
5 Tel_Tip OE1- OutB OE2- OutB 4Wire- OutB
6 NC Ch1_64kb/s_ codir._InpB Ch2_64kb/s-codir._InpB NC
7 NC OE1- InpA OE2- InpA 4Wire- InpA
8 NC OE1- InpB OE2- InpB 4Wire- InpB

See Evolution Manager for setup of the EOW Unit.


Handset
The handset connector is inserted in Port 1 of the EOW Unit.
Call
Push the ON/OFF HOOK button for activation / de-activation of the handset. When the handset is activated, the "IN USE"
lamp is lit.
Dial the number.

Memory
One number can be stored in memory.

● Push the "ON/OFF HOOK" button (the "IN USE" lamp is lit).
● Dial the number to be stored in memory (if required a 3s pause can be added to the number, by means of the "Pause"
button).
● Push the "MEM" button.
● Push the "ON/OFF HOOK" button (the "IN USE" lamp is switched off).

Dial from memory

● Push the "ON/OFF HOOK" button (the "IN USE" lamp is lit).
● Push the "MEM" button.

Battery
This handset uses one R03/LR03/AAA battery. The battery is used for holding the handset memories (MEM and REDIAL)
when the handset is disconnected from the EOW unit.
With exeption of "MEM" and "Redial" the handset is fully functional without battery,
The battery compartment is placed on the back of the handset. Before the compartment lid is removed, the connector must
be unplugged from the EOW unit, and the lid screw must be unscrewed.
4x64kb/s Auxiliary Unit overview

The 4x64kb/s Auxiliary Unit includes 4 ports (RJ45):

The Unit contains interfaces for 4, 64kb/s channels:


2 according to ITU-T Rec.G703, co-dir. timing
1 according to ITU-T Rec.G703, contra-dir. timing
1 according to ITU-T Rec. V.11 Contra-/CO-dir. timing without byte timing.

1......8

Pin no. PORT1 PORT2 PORT3 PORT4


1 Data_64kb/s_contra_Tx- 64kb/s_co._Tx1- 64kb/s_co._Tx2- Data_64kb/s_V11_Tx-
2 Data_64kb/s_contra_Tx+ 64kb/s_co._Tx1+ 64kb/s_co._Tx2+ Data_64kb/s_V11_Tx+
3 Clk_64kHz_contra_Tx+ NC NC Clk_64kHz_V11_Tx-
4 Clk_64kHz_contra_Tx- NC NC Clk_64kHz_V11_Tx+
5 Data_64kHz_contra_Rx+ 64kb/s_co._Rx1+ 64kb/s_co._Rx2+ Data_64kHz_V11_Rx-
6 Data_64kHz_contra_Rx- 64kb/s_co._Rx1- 64kb/s_co._Rx2- Data_64kHz_V11_Rx+
7 Clk_64kb/s_contra_Rx+ NC NC Clk_64kb/s_V11_Rx-
8 Clk_64kb/s_contra_Rx- NC NC Clk_64kb/s_V11_Rx+

See Evolution Manager for setup of the 4x64kb/s Unit


Alarm & Control Unit Overview

The Alarm & Control Auxiliary Unit includes 4 ports (RJ45):

The main functions of the unit are:

● Collection of alarms from external equipment


● Control of external processes
● Access to analogue readings from external equipment
● Access of the external modules with the supervisory system.
● Interface with the supervisory system.

1......8

Pin no. PORT1 PORT2 PORT3 PORT4


1 Analog_1 Alm_In_1+ Alm_In_5+ Relay_1+
2 Analog_2 Alm_In_1- Alm_In_5- Relay_1-
3 Analog_3 Alm_In_2+ Alm_In_6+ Relay_2+
4 Analog_4 Alm_In_2- Alm_In_6- Relay_2-
5 Analog_5 Alm_In_3+ Alm_In_7+ Relay_3+
6 Analog_6 Alm_In_3- Alm_In_7- Relay_3-
7 Analog_7 Alm_In_4+ Alm_In_8+ Relay_4+
8 Com_AD_GND Alm_In_4- Alm_In_8- Relay_4-

See Evolution Manager for setup of the Alarm & Control Unit
E1/T1 Wayside Unit overview

Return to IFU overview

The E1/T1 Wayside Unit has two wayside channels supporting E1 (2.048 Mb/s) or T1 (1.544 Mb/s) traffic.
E1 physical interface is compliant with ITU-T Rec. G.703, 120 ohm balanced [4].
T1 (DS1) physical interface is compliant with ANSI Rec. T1.102-1993 [5] and Telcordia Rec. GR-499 [6], 100 ohm balanced.

1......8

Pin no. PORTA PORTB


1 Channel 1 Input (RXP 1) Channel 2 Input (RXP 2)
2 Channel 1 Input (RXN 1) Channel 2 Input (RXN 2)
3 NC NC
4 Channel 1 Output (TXP 1) Channel 2 Output (TXP 2)
5 Channel 1 Output (TXN 1) Channel 2 Output (TXN 2)
6 NC NC
7 GND GND
8 GND GND

See Evolution Manager for setup of the E1/T1 Wayside Unit.


FAN overview

In order to control the temperature as well as increase component lifetime, a Fan Unit is implemented as cooling mechanism.

See Evolution Manager for details on FAN Unit


Digital Cross Connect Unit (DXC) Overview

The DXC unit has 2 main functions; the Digital cross(X) connect (DXC) function and node synchronization; SETS.
The SETS provides the DXC with timing clock to retime data streams.
The SETS function has a 1.5 Mb/s or 2 MHz customer interface for timing input and output
The SETS function applies to: ITU-T G.823 (03/2000), ITU-T K.41, ITU_T G.813 (03/2003)Prepubl. and ANSI T1.105-2001.

The DXC function is a full non-blocking cross connect of 4 different 155Mb/s data streams according to VC-11.

SYNCH connector

1......8

Pin no. Signal


1 RX_Ring
2 RX_Tip
3 NC Evolution Manager for setup of the DXC Unit
4 TX_Ring
5 TX_Tip
6 NC
7 GND
8 GND
Line Interface 3xDS3/E3 Unit overview

The Line Interface 3xDS3/E3 LIU contains 3xDS3/E3 electrical customer interfaces,
according to the ITU-T Rec; G.703, ANSI; T1-102 and Bellcore; GR-499

Connector type: DIN47297; 1.0/2.3mm dual coax connector x3

See Evolution Manager for setup of the LIU 3xDS3/E3 Unit


Gigabit Ethernet Unit overview

All the interfaces (Ports) may be enabled / disabled individually. However, if the 1000 Base-X (SFP) is selected, a maximum of 3x10/100
Base-T are available.

Connectors
Port 1 to 3
RJ45 connectors for 10/100 Base-T traffic

Port 4
RJ45 connectors for 10/100/1000 Base-T traffic
Port 5
SFP module for 1000Base-X traffic (Plug-in module is required)

See Evolution Manager for setup of the Gigabit Ethernet Unit


Outdoor Unit (ODU) Overview
The ODU consists of a transceiver and a diplexer unit interconnected by means of coaxial connectors (6 to 11 GHz) or waveguide interface (13 GHz <).
The figure below shows the features and interfaces.
ODU Marking
There are 3 labels on the ODU;

● One XCVR identification label, placed on the tranceiver right side (seen from front).
● One Diplexer identification label, placed on one side of the Diplexer.
● One ODU identification label, placed on the Diplexer (opposite side of Diplexer identification)

See illustrations below:

XCVR
identification
label

Diplexer
identification
label
ODU
identification
label

(placed opposite
side of Diplexer
identification
label)

Warning! The XCVR and Diplexer shall not be separated. Separation of XCVR/Diplexer will result in waranty void.

S-ar putea să vă placă și