X-RAY RADIATION PRECAUTION 1. Operation of the receiver outside the cabinet or with the back cover removed presents a shock hazard from the receiver. The high voltage of this receiver must not under any circumstances exceed 2S.3V.
X-RAY RADIATION PRECAUTION 1. Operation of the receiver outside the cabinet or with the back cover removed presents a shock hazard from the receiver. The high voltage of this receiver must not under any circumstances exceed 2S.3V.
Drepturi de autor:
Attribution Non-Commercial (BY-NC)
Formate disponibile
Descărcați ca PDF, TXT sau citiți online pe Scribd
X-RAY RADIATION PRECAUTION 1. Operation of the receiver outside the cabinet or with the back cover removed presents a shock hazard from the receiver. The high voltage of this receiver must not under any circumstances exceed 2S.3V.
Drepturi de autor:
Attribution Non-Commercial (BY-NC)
Formate disponibile
Descărcați ca PDF, TXT sau citiți online pe Scribd
SERVICE MANUAL
4BUSH
era e474 eae
COLOUR TELEVISION
ALBA +BuUSsH [fad HINARI‘TV BROADCAST STANDARD
RECEIVING CHANNELS
NUMBER OF PRESET CHANNELS
CHANNEL INDICATOR
RF AERIAL INPUT
PICTURE TUBES:
‘SPEAKER:
AUDIO OUTPUT POWERS:
OPERATING VOLTAGES
POWER CONSUMPTIONS
DIMENSIONS (MM)
NET WEIGHTS (KG)
ar azozaeset
gl aru Sd
PAL COR
UHF (BAND | & Ill) 2114
UHF (BAND U) 2114
UHF (BAND U) 2020/2321
0
LED DISPLAY
75 OHM (UNBALANCED)
14° PIL 90° 2t14
20" PIL 90° 2020
21° FST PIL 90° 2321
80HM
1.5W (MAX)
180-270V AC 50 HZ
6oW 2114
85w 2020
85Ww 2321
460X315X350 2114
610X420X455 2020
‘STTXA22X465 2321
125 2114
25 2020
25 221er aeoaneset
SAFETY INSTRUCTIONS
WARNING:
BEFORE SERVICING THIS CHASSIS, PLEASE READ THE “X-RAY RADIATION PRECAUTION’,
“SAFETY PRECAUTION” AND “PRODUCT SAFETY NOTICE” DESCRIBED BELOW.
X-RAY RADIATION PRECAUTION
1. Excessive high voltages can produce potentially hazardous X-RAY RADIATION. To avoid such
hazards, the high voltage must not be above the specified limit. The nominal value ofthe high
voltage of this receiver is 22.5KV at zero beam current (minimum brightness) under specified
ower source. The high voltage must not under any circumstances exceed 25.3V.
2. The only source of X-RAY RADIATION iin this TV receiver isthe picture tube. For continued
X-RAY RADIATION protection, the replacement tube must be of the same type tube as that
specified in the parts list.
‘SAFETY PRECAUTION
1. Potentials as high as 24,000 volts are present when this receiver is operating. Operation of the
Feceiver outside the cabinet or with the back cover removed presents a shock hazard from the
receiver.
(a) Servicing should not be attempted by anyone who is not thoroughly familiar withthe precuations
necessary whan working on high-voltage equipmert.
(b) Always discharge the picture tube anode to the CHASSIS GROUND to remove shock hazard
before disconnecting the anode cap.
(c) Completely discharge the high potential of the picture tube before handling. The picture tube is
highly evacuated and i broken glass fragments will be violently expelled.
2. Inthe event of fuse replacement, it should be replaced with the fuse type specified in the chassis
parts list.
3. When replacing parts or circuit boards, wind the lead wires around terminals before soldering
4. When replacing a high wattage resistor (oxide metal fim resistor in the circuit board the resistor
should be mounted 10mm away from circuit board.
PRODUCT SAFETY NOTICE
Many electrical and mechanical parts in this chassis have special safety-related characteristics.
These characteristics are often passed unnoticed by visual inspection and the X-RAY RADIATION
protection afforded by them cannot necessarily be obtained by using replacement components rated
for higher voltage, wattage, etc. Replacement parts which have these special safety characterstics
are identified by 7. in this manual and its supplements.
Before replacing any of these components, read the parts list this manual carefully. The use of
substitute replacement parts which do not have the same safety characteristics as spectfid in the
parts ist may create X-RAY RADIATION.
’