Sunteți pe pagina 1din 2

OTDR Report

General Information
Filename: Test date: Test time: Job ID: Comments: Fiber0014.trc 08/03/2011 10:22 p.m. (GMT-05:00) Cable ID: Fiber ID: Customer: Company: Fiber0000

Location A
Location: Operator: Units model: Units s/n: FTB-7200D-023B-EI 484214

Location B
Location: Operator:

Results
Span length: Span loss: Average loss: 11.0968 km 2.295 dB 0.207 dB/km Average splice loss: Maximum splice loss: Span ORL:

Test Parameters
Wavelength: Range: Pulse: 1550 nm 20.0000 km 1.0 s (9 m) Duration: High resolution: Resolution: 30 s No 2.552 m

Test Settings
IOR: Backscatter: Helix factor: 1.468325 -81.87 dB 0.00 % Splice loss threshold: Reflectance threshold: End-of-fiber threshold: 0.020 dB -72.0 dB 5.000 dB

Graphic

Signature:

Date: 09/03/2011

Pgina 1 de 2

OTDR Report
Event Table
Type Number Location/Length (km) Loss (dB) Reflection (dB) Attenuation (dB/km) Cumul. (dB)

Launch Level Section Reflective Event

1 2

0.0000 11.0968 11.0968 2.295

-23.7 0.207 -15.6

0.000 2.295 2.295

Markers Information
A: a: B-A: 7.9985 km 3.9992 km 3.9992 km 5.997 dB 6.445 dB 3.261 dB B: b: 11.9977 km 15.9970 km 2.736 dB 2.208 dB

Manual Measurements
4-pt. ev. loss: A-B LSA loss: 2-pt. sect. att.: 4.400 dB -1.572 dB 0.815 dB/km A-B LSA att.: 3-pt. reflectance: A-B ORL: -0.393 dB/km ***** 16.95 dB

Signature:

Date: 09/03/2011

Pgina 2 de 2