Sunteți pe pagina 1din 94

Company Confidential

Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 1 2009 Nokia Siemens Networks
Nokia Siemens Networks
NSN Optimizer 2.2 CD2
MBNL User Guide
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 2 2009 Nokia Siemens Networks
Checking Needs to be Done Each Morning
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 3 2009 Nokia Siemens Networks
Checking the status of Auto-retrievaI Process from
the Task Management Option
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 4 2009 Nokia Siemens Networks
ExampIe: The 3G PM Auto-RetrievaI is OK
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 5 2009 Nokia Siemens Networks
ExampIe: Showing Auto-retrievaI errors
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 6 2009 Nokia Siemens Networks
Importing Sites Configuration into
Optimizer
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 7 2009 Nokia Siemens Networks
Define the new sites into the ExceI fiIe
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 8 2009 Nokia Siemens Networks
Import the new site ExceI fiIe into Optimizer using the
Optimizer Antenna Data Editor
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 9 2009 Nokia Siemens Networks
After the import, the new sites wiII be highIighted
in grey in the Optimizer Antenna Data Editor
Error found
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 10 2009 Nokia Siemens Networks
Refresh the new site data in the Optimizer in
FiIe->CM Data Exchange
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 11 2009 Nokia Siemens Networks
Check CM Refresh Progress from the Task Manager
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 12 2009 Nokia Siemens Networks
Defining the required Scope or PIan Area
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 13 2009 Nokia Siemens Networks
Define 3UK F1 using CeII Group
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 14 2009 Nokia Siemens Networks
Define 3UK F3 using CeII Group
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 15 2009 Nokia Siemens Networks
Define TMO F9 using CeII Group
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 16 2009 Nokia Siemens Networks
SeIect required CeII groups and Locate on Map
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 17 2009 Nokia Siemens Networks
Defined the seIected ceIIs as Scope or PIan area.
On the seIected ceIIs->right hand cIick->Scope->Create new scope
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 18 2009 Nokia Siemens Networks
Start the WCDMA Measurement
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 19 2009 Nokia Siemens Networks
Step- 1: Define RNC Scopes
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 20 2009 Nokia Siemens Networks
Step-2: Start Defining WCDMA Measurements from
Optimizer
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 21 2009 Nokia Siemens Networks
Step-3: Defining two 1-hour WCDMA
Measurements in Optimizer
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 22 2009 Nokia Siemens Networks
Step-3: Define Starting Time and Duration of
WCDMA Measurement
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 23 2009 Nokia Siemens Networks
Step 4: Define RNC Scopes.
CIick Start
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 24 2009 Nokia Siemens Networks
Step 5: After the start button is pressed. The
status of the Measurement can be monitored here
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 25 2009 Nokia Siemens Networks
ADJS DeIetion
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 26 2009 Nokia Siemens Networks
Make sure the PM measurements have vaIid data on the
date that you want to use for ADJS DeIetion Optimisation
Select Date where Measurement were made for RAS06 RNC
Choose SHO Attempt Rate and
SHO Share to check whether
there are valid PM Measurement
on map
Select Scope
Right hand click on selected cells->Show Adjacencies->Show all Adjacencies
Select Date where Measurement were made for RU10 RNC
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 27 2009 Nokia Siemens Networks
Start ADJS DeIetion Process
(1) Select Date where Measurement were made for RAS06 RNC
(1) Select Date where Measurement were made for RU10 RNC
(2) Select Scope
(3) Start ADJ Optimisation Tool
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 28 2009 Nokia Siemens Networks
SeIect ADJS
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 29 2009 Nokia Siemens Networks
Define ADJS RuIes
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 30 2009 Nokia Siemens Networks
Define Minimum and Maximum ADJS Iist Iength.
Note, the minimum vaIues is set to 20
Outgoing and incoming
adjacencies are both deleted if
both have at least one poor
optimization value.
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 31 2009 Nokia Siemens Networks
Define the ADJS DeIetion ThreshoIds
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 32 2009 Nokia Siemens Networks
ADJS DeIetion ResuIts
(2) Examine the ADJS Deletion Results
(4) List the ADJS Deletion Plan to browser
(3) Save the ADJS Deletion Results to Plan
(1) Start ADJS Deletion Tool
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 33 2009 Nokia Siemens Networks
The ADJS DeIetion ResuIts for aII ceIIs
ADJS Deletion Results.
Black Dotted lines
ADJS Creation Results.
White Dotted lines
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 34 2009 Nokia Siemens Networks
The ADJS DeIetion ResuIts for one ceIIs
ADJS Deletion Results.
Black Dotted lines
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 35 2009 Nokia Siemens Networks
The ADJS DeIetion ResuIts for one ceIIs
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 36 2009 Nokia Siemens Networks
Once you are happy with the ADJS, you can export the resuIts as a
pIan into CM Operations Manager by cIicking here
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 37 2009 Nokia Siemens Networks
(1) In the CM Operations Manager, you can provision the
ADJS DeIetion pIan into the network
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 38 2009 Nokia Siemens Networks
(2) In the CM Operations Manager, you can provision the
ADJS DeIetion pIan into the network
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 39 2009 Nokia Siemens Networks
ADJS Creation
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 40 2009 Nokia Siemens Networks
Define ADJS TempIate
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 41 2009 Nokia Siemens Networks
Define ADJS tempIate in the CM Editor
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 42 2009 Nokia Siemens Networks
Define the ADJS tempIate to be used in the Optimizer
To be able to manage template assignment
rules, you either need to have the Optimizer
Administrator role or the permission operation
EDIT_TEMPLATE_ASSIGNMENT_RULES
included in the role assigned to you
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 43 2009 Nokia Siemens Networks
Define the ADJS tempIate to each RNC
To be able to manage template assignment
rules, you either need to have the Optimizer
Administrator role or the permission operation
EDIT_TEMPLATE_ASSIGNMENT_RULES
included in the role assigned to you
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 44 2009 Nokia Siemens Networks
Check Content of WCDMA
Measurement
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 45 2009 Nokia Siemens Networks
Make sure the WCDMA and PM measurements have vaIid data on the
date that you want to use for ADJS Optimisation
Select Date where Measurement were made for RAS06 RNC
Choose RSCP to check whether
there are valid WCDMA
Measurement on map.
Then choose SHO Attempt Rate to
check PM Measurement on map
Select Scope
Right hand click on selected cells->Show Adjacencies->Show all Adjacencies
Select Date where Measurement were made for RU10 RNC
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 46 2009 Nokia Siemens Networks
ADJS Creation Optimisation
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 47 2009 Nokia Siemens Networks
Start ADJ Optimisation tooI
(1) Select Date where Measurement were made for RAS06 RNC
(1) Select Date where Measurement were made for RU10 RNC
(2) Select Scope
(3) Start ADJ Optimisation Tool
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 48 2009 Nokia Siemens Networks
Start ADJS Optimisation tooI
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 49 2009 Nokia Siemens Networks
Define ADJS RuIes
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 50 2009 Nokia Siemens Networks
Define the Minimum & Maximum Number of ADJS per CeII
Check = Outgoing and incoming
adjacencies are both created if
the outgoing adjacency has all
good optimization values.
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 51 2009 Nokia Siemens Networks
Check this Option
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 52 2009 Nokia Siemens Networks
Define ADJS Creation ThreshoIds
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 53 2009 Nokia Siemens Networks
Save the ADJS ResuIts to PIan.
(1) Press Start
Optimisation button.
(2) The ADJS
Creation will show
here.
(3) Save the ADJS
Results to Plan.
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 54 2009 Nokia Siemens Networks
List the ADJS Creation resuIts onto the browser
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 55 2009 Nokia Siemens Networks
List the ADJS Creation resuIts on Map
The browser shows the
ADJS Creation results
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 56 2009 Nokia Siemens Networks
Examine AII the ADJS Creation resuIts on Map
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 57 2009 Nokia Siemens Networks
Examine the ADJS Creation resuIts on Map for one CeII.
Dotted Iines are the new Proposed ADJS Creations. SoIid
Iines are the Iive ADJSs.
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 58 2009 Nokia Siemens Networks
Examine the ADJS Creation resuIts on Map for one CeII.
Dotted Iines are the new Proposed ADJS Creations. SoIid
Iines are the Iive ADJSs.
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 59 2009 Nokia Siemens Networks
If you are not happy with the ADJS proposaI, you
can deIete it from the pIan
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 60 2009 Nokia Siemens Networks
Once you are happy with the ADJS, you can export the resuIts as a
pIan into CM Operations Manager by cIicking here
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 61 2009 Nokia Siemens Networks
(1) In the CM Operations Manager, you can provision the
ADJS pIan into the network
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 62 2009 Nokia Siemens Networks
(2) In the CM Operations Manager, you can provision the
ADJS pIan into the network
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 63 2009 Nokia Siemens Networks
ADJG Optimisation
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 64 2009 Nokia Siemens Networks
ADJG Optimisation
The ADJG Optimisation done using the following method:
- Reduce the number ADJGs within the ADJG list of each cell
in the plan area down to about, say, 25 per cell using the
MBNL in-house process or Optimizer.
- Create the Rotation ADJG list as ADJG plans using the
Optimizer
- Provision the 1
st
Rotation ADJG plan into the network. Make
WCDMA measurement for 1 day.
- Repeat the last process until all the ADJG plan has been
provisioned into the network. Note, the last plan is used to set
the network back to its original state. Therefore, you do not
need to make WCDMA measurement after the last plan.
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 65 2009 Nokia Siemens Networks
ADJG Optimisation: SeIect Measurement Date, then Start
Adjacency Optimisation TooI
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 66 2009 Nokia Siemens Networks
ADJG Optimisation : SeIect ADJG
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 67 2009 Nokia Siemens Networks
ADJG Optimisation: Define the ADJG parameters
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 68 2009 Nokia Siemens Networks
ADJG Optimisation :
(1) Define the Distance threshoIds,
(2) Press start optimisation button.
(3) Press save pIan button and define the Rotation PIan name
(1)
(2)
(3)
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 69 2009 Nokia Siemens Networks
ADJG Optimisation : After defining the Rotation pIan name. Two Rotation pIans wiII be
created by the Optimizer. In this exampIe, the "ADJG Rotation PIan" is created for measuring the
quaIity of the surrounding ceIIs that are not in the actuaI ADJG Iist. The "ADJG Rotation PIan_2" is
created to set the ADJG Iist in the pIan area back to the originaI state.
The ADJG Optimisation process is described in the foIIowing:
(1) Export the "ADJG Rotation PIan" into CM Operations Manager. From the CM Operations Manager
provision the pIan into the network.
(2) Make WCDMA measurement of the pIan area for 1 day
(3) Export the "ADJG Rotation PIan_2" into CM Operations Manager. From the CM Operations
Manager provision the pIan into the network. This wiII set the ADJG in the pIan area back to the
originaI state, i.e. before (1)
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 70 2009 Nokia Siemens Networks
ADJG Optimisation :
(1) Set the WCDMA Measurement date to the date when the Rotation Measurement was made.
(2) Start the ADJG Adjacency Optimisation tooI
(3) Define the ADJG Creation parameters
(4) Press Start Optimisation button
(5) Save the ADJG optimisation pIan by pressing the save button
(6) examine the ADJG pIan in the browser by seIecting FiIe->List PIanned EIements
(7) Examine the ADJG pIan on the map by seIecting the ADJG on the browser and Iist to map
(8) Once you are happy with the ADJG proposaI on the map. Export the proposed "ADJG pIan" into
CM Operations Manager. From the CM Operations Manager provision the pIan into the network.
(1)
(4)
(3)
(5)
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 71 2009 Nokia Siemens Networks
Interference AnaIysis
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 72 2009 Nokia Siemens Networks
(1) Create Interference Mantrix
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 73 2009 Nokia Siemens Networks
(1) Create Interference Mantrix
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 74 2009 Nokia Siemens Networks
(1) Create Interference Mantrix: SeIect either date (when the
CDMA measurement was made) or Measurement name
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 75 2009 Nokia Siemens Networks
(1) Create Interference Mantrix: Activate the WCDMA
measurement that you want to anaIyse the interference of
the ceIIs
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 76 2009 Nokia Siemens Networks
(1) Create Interference Mantrix: SeIect the Show
Sets button
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 77 2009 Nokia Siemens Networks
(1) Create Interference Matrix: After the Show Sets button is pressed,
the interference matrix between the source ceII and the surrounding
ceIIs are shown in the tabIe beIow
Source cell
Surrounding cells
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 78 2009 Nokia Siemens Networks
(2) Showing Interference Matrix
GeographicaIIy
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 79 2009 Nokia Siemens Networks
(2) Showing Interference Matrix GeographicaIIy:
Define the Parameter for the Interference Line
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 80 2009 Nokia Siemens Networks
(2) Showing Interference Matrix GeographicaIIy:
Define which ceII to anaIyse interference
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 81 2009 Nokia Siemens Networks
(2) Showing Interference Matrix GeographicaIIy
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 82 2009 Nokia Siemens Networks
(3) ManuaI Interference Matrix
AnaIysis
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 83 2009 Nokia Siemens Networks
(3) ManuaI Interference Matrix AnaIysis: Activate
the Interference matrix here, then SeIect this
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 84 2009 Nokia Siemens Networks
(3) ManuaI Interference Matrix AnaIysis:
Press the AnaIyze button to start the
anaIysis
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 85 2009 Nokia Siemens Networks
(3) ManuaI Interference Matrix AnaIysis: The tabIe shows
the Interference Matrix (IM). SeIect the IM that you want to
anaIyse and press Iocate on Map button
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 86 2009 Nokia Siemens Networks
(3) ManuaI Interference Matrix AnaIysis:
DispIay IM GeographicaIIy
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 87 2009 Nokia Siemens Networks
(3) ManuaI Interference Matrix AnaIysis: SeIect aII
the IM in the IM tabIe. Press the Show Chart Button
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 88 2009 Nokia Siemens Networks
(3) ManuaI Interference Matrix AnaIysis: Each bIue dot represents how
far a particuIar target ceII is away from its source ceII and how much
this target ceII is interfering the source ceII
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 89 2009 Nokia Siemens Networks
(4) Automated Interference Matrix
AnaIysis
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 90 2009 Nokia Siemens Networks
(4) Automated Interference Matrix AnaIysis: SeIect
the RuIe to anaIyse. Then press the Run button
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 91 2009 Nokia Siemens Networks
(4) Automated Interference Matrix AnaIysis:
The resuIts show GeographicaIIy
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 92 2009 Nokia Siemens Networks
(5) Propagation DeIay VisuaIisation
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 93 2009 Nokia Siemens Networks
(5) Propagation DeIay VisuaIisation
(1) Define WCDMA Measurement
(3) Define Distance colour
(4) Press here
(2) Select
Company Confidential
Optimizer 2.2 CD2 User Guide / Chik Chen / 25-9-2009 94 2009 Nokia Siemens Networks
(5) Propagation DeIay VisuaIisation: SeIect
Scope->Anaysis->Show on histogram

S-ar putea să vă placă și