HP StorageWorks 4x00/6x00/8x00 Enterprise Virtual Array hardware conguration guide

Part number: 5697-7338 Fifth edition: February 2008

Legal and notice information Copyright 2005-2008 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.

Contents
About this guide
Intended audience . . . . . . . . Related documentation . . . . . . Document conventions and symbols Rack stability . . . . . . . . . . HP technical support . . . . . . . Customer self repair . . . . . . . Product warranties . . . . . . . . Subscription service . . . . . . . HP websites . . . . . . . . . . . Documentation feedback . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . 9 . . 9 . . 9 . 10 . 10 . 11 . 11 . 11 . 11 . 11

1 EVA 4x00/6x00/8x00 hardware . . . . . . . . . . . . . . . . .


Storage rack . . . . . . . . . . . . . . . . 36U rack . . . . . . . . . . . . . . . . 42U rack . . . . . . . . . . . . . . . . Fibre Channel drive enclosures . . . . . . . . . Fibre Channel loop switches . . . . . . . . . . EVA8x00 HSV210-A/B controllers . . . . . . . EVA6x00 and EVA4x00 HSV200-A/B controllers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . .

. . . . . . .

13

13 13 13 13 14 16 17

2 EVA8x00 congurations . . . . . . . . . . . . . . . . . . . . .

2C2D congurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2C6D congurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2C12D conguration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

19

19 23 27

3 EVA6x00 congurations . . . . . . . . . . . . . . . . . . . . .
2C4D 2C5D 2C6D 2C7D 2C8D conguration conguration conguration conguration conguration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . .

. . . . .

31

31 33 35 37 39

4 EVA4x00 congurations . . . . . . . . . . . . . . . . . . . . .
2C1D 2C2D 2C3D 2C4D conguration conguration conguration conguration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . .

. . . .

43

43 45 47 49

A Specications . . . . . . . . . . . . . . . . . . . . . . . . . .

Physical specications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Environmental specications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Power specications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

53
53 53 54

B Low-voltage Japanese cabinets

General description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Reference documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . .

59

59 59

4x00/6x00/8x00 Enterprise Virtual Array hardware conguration guide

Power congurations . . . . Specications . . . . . . . EVA cabinet footprint . . Weights and dimensions Center of gravity . . . . Tip stability . . . . . .

. . . . . .

. . . . . .

. . . . . .

. . . . . .

. . . . . .

. . . . . .

. . . . . .

. . . . . .

. . . . . .

. . . . . .

. . . . . .

. . . . . .

. . . . . .

. . . . . .

. . . . . .

. . . . . .

. . . . . .

. . . . . .

. . . . . .

. . . . . .

. . . . . .

. . . . . .

. . . . . .

. . . . . .

. . . . . .

. . . . . .

. . . . . .

. . . . . .

. . . . . .

. . . . . .

. . . . . .

. . . . . .

59 60 61 61 61 62

Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

63

Figures
1 FC drive enclosurefront and rear views . . . . . . . . . . . . . . . . . . . . . . 2 30-10022-01 FC loop switch . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 30-10010-02 FC loop switch . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 HSV210/200 controllerfront view . . . . . . . . . . . . . . . . . . . . . . . . 5 HSV210-A/B controllerrear view 6 HSV200-A/B controllerrear view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 15 15 16 17 18 19 20 21 22 23 24 25 26 27 28 31 32 33 34 35 36 37 38 39 40 43 44 45 46 47 48 49

7 2C2D Storage-Centric conguration . . . . . . . . . . . . . . . . . . . . . . . . 8 EVA8x00 2C2D Storage-Centric cable diagram . . . . . . . . . . . . . . . . . . . 9 2C2D Multi-Product conguration . . . . . . . . . . . . . . . . . . . . . . . . . 10 EVA8x00 2C2D Multi-Product cable diagram . . . . . . . . . . . . . . . . . . . . 11 2C6D Storage-Centric conguration . . . . . . . . . . . . . . . . . . . . . . . . 12 EVA8x00 2C6D Storage-Centric conguration cable diagram . . . . . . . . . . . . . 13 2C6D Multi-Product conguration . . . . . . . . . . . . . . . . . . . . . . . . . 14 EVA8x00 2C6D Multi-Product conguration cable diagram . . . . . . . . . . . . . . 15 2C12D conguration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 EVA8x00 2C12D cable diagram . . . . . . . . . . . . . . . . . . . . . . . . . 17 2C4D conguration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 EVA6x00 2C4D cable diagram . . . . . . . . . . . . . . . . . . . . . . . . . . 19 2C5D conguration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 EVA6x00 2C5D cable diagram . . . . . . . . . . . . . . . . . . . . . . . . . . 21 2C6D conguration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 EVA6x00 2C6D cable diagram . . . . . . . . . . . . . . . . . . . . . . . . . . 23 2C7D conguration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 EVA6x00 2C7D cable diagram . . . . . . . . . . . . . . . . . . . . . . . . . . 25 2C8D conguration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 EVA6x00 2C8D cable diagram . . . . . . . . . . . . . . . . . . . . . . . . . . 27 2C1D conguration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 EVA4x00 2C1D cable diagram . . . . . . . . . . . . . . . . . . . . . . . . . . 29 2C2D conguration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 EVA4x00 2C2D cable diagram . . . . . . . . . . . . . . . . . . . . . . . . . . 31 2C3D conguration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 EVA4x00 2C3D cable diagram . . . . . . . . . . . . . . . . . . . . . . . . . . 33 2C4D conguration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4x00/6x00/8x00 Enterprise Virtual Array hardware conguration guide

34 EVA4x00 2C4D cable diagram . . . . . . . . . . . . . . . . . . . . . . . . . . 35 HP StorageWorks 42U low-voltage cabinet . . . . . . . . . . . . . . . . . . . . . 36 HP StorageWorks 36U low-voltage cabinet . . . . . . . . . . . . . . . . . . . . . 37 EVA cabinet footprint . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

50 60 60 61

Tables
1 Document conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Maximum storage capacities for the 2C2D conguration . . . . . . . . . . . . . . . 4 Maximum storage capacities for the 2C6D conguration . . . . . . . . . . . . . . . 5 Maximum storage capacities for the 2C12D conguration . . . . . . . . . . . . . . 6 Maximum storage capacities for the 2C4D conguration . . . . . . . . . . . . . . . 7 Maximum storage capacities for the 2C5D conguration . . . . . . . . . . . . . . . 8 Maximum storage capacities for the 2C6D conguration . . . . . . . . . . . . . . . 9 Maximum storage capacities for the 2C7D conguration . . . . . . . . . . . . . . . 10 Maximum storage capacities for the 2C8D conguration . . . . . . . . . . . . . . . 11 Maximum storage capacities for the EVA4x00 2C1D conguration . . . . . . . . . . 12 Maximum storage capacities for the 2C2D conguration . . . . . . . . . . . . . . . 13 Maximum storage capacities for the 2C3D conguration . . . . . . . . . . . . . . . 14 Maximum storage capacities for the 2C4D conguration . . . . . . . . . . . . . . . 15 Enterprise Virtual Array 4x00/6x00/8x00 Product Dimensions, Weight and Clearance . . 16 Environmental specications . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Enterprise storage system AC input line voltages . . . . . . . . . . . . . . . . . . . 18 Power Data (North America/Europe/Japan) maximum conguration . . . . . . . . . . 19 EVA4x00 power specications 208 Volts 20 EVA4x00 power specications 230 Volts 21 EVA6x00 power specications 208 Volts 22 EVA6x00 power specications 230 Volts 23 EVA8x00 power specications 208 Volts 24 EVA8x00 power specications 230 Volts 26 HP StorageWorks 36U low-voltage cbinet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 23 27 29 33 35 37 39 41 44 46 48 51 53 54 54 55 55 55 56 56 57 57 61 61 62 62

25 HP StorageWorks 42U low-voltage cabinet . . . . . . . . . . . . . . . . . . . . . 27 Center of gravity measurements 42U low-voltage cabinet . . . . . . . . . . . . . . 28 Center of gravity measurements 36U low-voltage cabinet . . . . . . . . . . . . . .

4x00/6x00/8x00 Enterprise Virtual Array hardware conguration guide

About this guide


This hardware conguration guide provides information to help you: Learn about the Enterprise Virtual Array hardware components. Understand the supported storage rack congurations. Understand the supported copper cable congurations.

Intended audience
This book is intended for use by Enterprise Virtual Array customers involved in the installation, operation, and management of the EVA 4x00/6x00/8x00 storage systems and who are experienced with the following: SANs and storage systems. Networking and virtual storage concepts. Enterprise Virtual Array products.

Related documentation
Additional documentation is available from the HP website at http://www.hp.com/support/manuals. Select Disk Storage Systems from Storage, and then select either HP StorageWorks 4000/6000/8000 Enterprise Virtual Arrays or HP StorageWorks 4100/6100/8100 Enterprise Virtual Arrays from EVA Disk Arrays.

Document conventions and symbols


Table 1 Document conventions Convention
Blue text: Table 1 Blue, underlined text: http://www.hp.com

Element
Cross-reference links and e-mail addresses website addresses Keys that are pressed Text typed into a GUI element, such as a box GUI elements that are clicked or selected, such as menu and list items, buttons, tabs, and check boxes Text emphasis File and directory names System output Code Commands, their arguments, and argument values

Bold text

Italic text

Monospace text

Monospace, italic text Monospace, bold text

Code variables Command variables Emphasized monospace text

4x00/6x00/8x00 Enterprise Virtual Array hardware conguration guide

WARNING! Indicates that failure to follow directions could result in bodily harm or death.

CAUTION: Indicates that failure to follow directions could result in damage to equipment or data.

IMPORTANT: Provides clarifying information or specic instructions.

NOTE: Provides additional information.

TIP: Provides helpful hints and shortcuts.

Rack stability
Rack stability protects personnel and equipment. WARNING! To reduce the risk of personal injury or damage to equipment: Extend leveling jacks to the oor. Ensure that the full weight of the rack rests on the leveling jacks. Install stabilizing feet on the rack. In multiple-rack installations, fasten racks together securely. Extend only one rack component at a time. Racks can become unstable if more than one component is extended.

HP technical support
For worldwide technical support information, see the HP support website: http://www.hp.com/support Before contacting HP, collect the following information: Product model names and numbers Technical support registration number (if applicable) Product serial numbers Error messages Operating system type and revision level Detailed questions

10

About this guide

Customer self repair


HP customer self repair (CSR) programs allow you to repair your StorageWorks product. If a CSR part needs replacing, HP ships the part directly to you so that you can install it at your convenience. Some parts do not qualify for CSR. Your HP-authorized service provider will determine whether a repair can be accomplished by CSR. For more information about CSR, contact your local service provider. For North America, see the CSR website: http://www.hp.com/go/selfrepair This product has no customer replaceable components.

Product warranties
For information about HP StorageWorks product warranties, see the warranty information website: http://www.hp.com/go/storagewarranty

Subscription service
HP recommends that you register your product at the Subscriber's Choice for Business website: http://www.hp.com/go/e-updates After registering, you will receive e-mail notication of product enhancements, new driver versions, rmware updates, and other product resources.

HP websites
For additional information, see the following HP websites: http://www.hp.com http://www.hp.com/go/storage http://www.hp.com/service_locator

Documentation feedback
HP welcomes your feedback. To make comments and suggestions about product documentation, please send a message to storagedocsFeedback@hp.com. All submissions become the property of HP.

4x00/6x00/8x00 Enterprise Virtual Array hardware conguration guide

11

12

About this guide

1 EVA 4x00/6x00/8x00 hardware


This chapter discusses the hardware components in the Enterprise Virtual Array (EVA). The following topics are discussed: Storage rack Fibre Channel drive enclosures Fibre Channel loop switches EVA8x00 HSV210-A/B controllers EVA6x00 and EVA4x00 HSV200-A/B controllers

Storage rack
Racks are available for the EVA storage system in 36U and 42U congurations. The storage rack can hold a maximum of 12 Fibre Channel (FC) drive enclosures and two controllers.

36U rack
The 36U rack is graphite in color and 1000 mm (39.4 inches) deep. The 19inch (482.6 mm) industry-standard rack provides an enclosure for rack-mountable products with a height capacity of 36U. Perforated front and back doors are included, and 36U side panels and stabilizer kits are optional.

42U rack
The 42U rack is graphite in color and 909 mm (35.8 inches) deep. The storage rack features standard 19inch (482.6 mm) mounting rails. The 42U rack can support Enterprise Virtual Array congurations that include FC loop switches or expansion panels. Perforated front and back doors are included, and 42U side panels and stabilizer kits are optional.

Fibre Channel drive enclosures


Each FC drive enclosure includes the following features: 3U drive enclosure Dual redundant, active-to-active, 2Gbps Fibre Channel loops Fourteen 1inch Fibre Channel disks per enclosure Dual 2Gbps Fibre Channel I/O moduleA and B Enhanced fault detection Small Form-Factor Pluggables (SFPs) Dual 500W redundant hot-plug power supplies and fans For ease of reference, the disk drives are usually referred to by their physical location in the drive bay. Figure 1 shows the front and rear views of the FC drive enclosure and the physical location of each drive bay.

4x00/6x00/8x00 Enterprise Virtual Array hardware conguration guide

13

Front

10
Rear

10

9
0112a

Figure 1 FC drive enclosurefront and rear views


1. Drive bay 1 3. EMU 5. Blower 1 7. Blower 2 9. I/O module A 2. Drive bay 14 4. I/O module B 6. Power supply 1 8. Power supply 2 10. Status indicators (EMU, enclosure power, enclosure fault)

Fibre Channel loop switches


The Enterprise Virtual Array uses FC loop switches to connect all of the drive enclosures to the controller pair via copper cables. Each FC loop switch acts as a central point of interconnection and establishes a physical loop topology. Switch use: EVA4000/4100 does not use switches on any conguration EVA6000/6100 uses switches on all congurations EVA8000/8100 only uses switches with more than four disk enclosures The storage system uses one of the following loop switches: 30-10022-01 loop switchused with 2 Gb and 4 Gb controllers (required on EVA 4100/6100/8100) 30-10010-02 loop switchused with 2 Gb and 4 Gb controllers CAUTION: When using the 30-10022-01 loop switch, ensure that there is no disk in bays 12, 13, and 14 in enclosures 17, 20, and 24. Slots 13 and 14 are assigned the same ALPA as the controllers and slot 12 is assigned ALPA 4, which is taken by the 30-10022-01 loop switch. Failure to adhere to this rule will disrupt storage system operation. HP also recommends that you keep three additional bays open to maintain the maximum device count of 120. For ease of use and consistency in congurations, HP recommends keeping bays 12, 13, and 14 open in enclosures 16 and 19. The major features of the FC loop switch are: 2.125 Gbps operating speed

14

EVA 4x00/6x00/8x00 hardware

Twelve ports Half-width, 1U size System and port status indicators An Ethernet port Universal power supply that operates between 100 to 250 VAC (or 50 to 60 Hz) SFP transceivers

Figure 2 shows the rear view of the 30-10022-01 Fibre Channel loop switch.
1 2 3 4

100-240V~, 50/60 H Z

POWER FAULT TEMP 7 8 9 10 11 12

10101

Figure 2 30-10022-01 FC loop switch


1. Ethernet activity 3. Port status 2. Ethernet link 4. System status

Figure 3 shows the front and rear views of the 30-10010-02 Fibre Channel loop switch.

4 2

4 2

10

Figure 3 30-10010-02 FC loop switch


1. Handle 3. Alignment tabs 5. SFP status indicator 7. POST fault indicator 9. Power indicator 2. Bezel snaps 4. Walk-up RS-232 port 6. Port Bypassed indicator 8. Over Temp indicator 10. Loop operational indicator

4x00/6x00/8x00 Enterprise Virtual Array hardware conguration guide

15

EVA8x00 HSV210-A/B controllers


Two high-performance HSV210 controllers are included in each EVA8x00 rack. The EVA8000 controller is identied as HSV210-A and the EVA8100 controller is identied as HSV210-B. Each controller is contained in a separate enclosure and provides the following features: High-performance PowerPC microprocessor An Operator Control Panel (OCP) for easy operation 4U rack space required for both controller enclosures Four 4Gbps Fibre Channel-Switched Fabric host ports Four 2Gbps FC-AL device ports Arranged in redundant pairs Data load/performance balanced across a pair Supports up to 240 disks (120 disks per pair) 2 GB cache per controller, mirrored, with battery backup 2 Gbps FC cache mirroring port with device port backups Two mirror ports Dual power supplies

The controller is the interface between HP StorageWorks Command View EVA and the Enterprise Virtual Array (the interface between hosts and disks). Up to 18 drive enclosures are supported by one HSV210-A/B controller pair (two controllers). Figure 4 shows the front of the controller. Figure 5 shows the controller rear view.
6

4 4

Figure 4 HSV210/200 controllerfront view


1. Battery 0 3. Blower 0 5. Operator Control Panel (OCP) 7. Unit ID 2. Battery 1 (EVA8x00 only) 4. Blower 1 6. Status indicators

16

EVA 4x00/6x00/8x00 hardware

10

Figure 5 HSV210-A/B controllerrear view


1. Dual controller interconnect 3. Unit ID 5. FC device ports 7. FC host ports 9. Power supply 1 2. CAB (cabinet address bus) 4. Power ON switch 6. FC cache mirror ports 8. Power supply 0 10. Service connectors (not for customer use)

EVA6x00 and EVA4x00 HSV200-A/B controllers


Two high-performance HSV200 controllers are included in each EVA6x00 and EVA4x00 storage system. The EVA4000/6000 controllers are identied as HSV200-A. The EVA4100/6100 controllers are identied as HSV200-B. Each controller is installed in a separate enclosure and provides the following features: High-performance, PowerPC microprocessor An Operator Control Panel (OCP) for easy operation 4U rack space required for both controller enclosures Two 4Gbps, FC-Switch Fabric host ports Two 2Gbps, FC-AL device ports Arranged as a single redundant pair Data load/performance balanced across a pair Support for up to 112 drives 1 GB cache per controller, mirrored, with battery backup 2 Gbps, FC cache mirroring port with device port backups Each HSV200-A/B controller supports four drive enclosures on the EVA4x00, and eight drive enclosures on the EVA6x00. Figure 4 shows the front of the controller. Figure 6 shows the controller rear view.

4x00/6x00/8x00 Enterprise Virtual Array hardware conguration guide

17

10

Figure 6 HSV200-A/B controllerrear view


1. Dual controller interconnect 3. Unit ID 5. FC device ports 7. FC host ports 9. Power supply 1 2. CAB (cabinet address bus) 4. Power ON switch 6. FC cache mirror ports 8. Power supply 0 10. Service connectors (not for customer use)

18

EVA 4x00/6x00/8x00 hardware

2 EVA8x00 congurations
This chapter discusses the standard EVA8x00 congurations. Each section describes the placement of HSV controllers, drive enclosures, enclosure address bus shelf ID expansion cables, and copper Fibre Channel cables. NOTE: The congurations described in this guide are the preferred congurations. Other congurations may be used, but they should conform to the following: Disk enclosures should be balanced across the two back-end loop pairs. Use of enclosure ID 7 for disk enclosures is not allowed.

2C2D congurations
There are two 2C2D congurations: the Storage-Centric (Figure 7) and the Multi-Product (Figure 9). Each conguration provides a maximum storage capacity of 8.4 TB and can contain a maximum of 28 disks. These congurations are available in a 42U rack and have two HSV210-A/B controllers and two drive enclosures. The Storage-Centric conguration can be expanded (by adding drive enclosures) while remaining online. The Multi-Product more easily allows multiple products to be racked with the EVA, but can only be expanded by powering it down to make these expansion modications.

2 3

1
16358

Figure 7 2C2D Storage-Centric conguration 1. Drive enclosure 2. HSV210-A/B controller pair 3. 3U blank The 2C2D Storage-Centric conguration cable routing diagram is located in Figure 8.

4x00/6x00/8x00 Enterprise Virtual Array hardware conguration guide

19

2 1

3 7 4

3
0178c

Figure 8 EVA8x00 2C2D Storage-Centric cable diagram 1. 2. 3. 4. 5. 6. 7. ID port 14 Top terminator Drive enclosure HSV210-A/B controller pair Bottom terminator Y cable Dual controller interconnect cable

20

EVA8x00 congurations

1 2 3 2 4
M n ai 1 2 3 4 M n ai 1 2 3 4

16354

Figure 9 2C2D Multi-Product conguration 1. 2. 3. 4. 3U blank Drive enclosure HSV210-A/B controller pair Power distribution units

The 2C2D Multi-Product conguration cable routing diagram is located in Figure 10.

4x00/6x00/8x00 Enterprise Virtual Array hardware conguration guide

21

2 6 3 4 5 7 6 8
16357

Figure 10 EVA8x00 2C2D Multi-Product cable diagram 1. 2. 3. 4. 5. 6. 7. 8. Top terminator ID port 6 Y cable Dual controller interconnect cable Bottom terminator Drive enclosure HSV210-A/B controller pair Power distribution units

2C2D features
The following features are included in the 2C2D: One storage rack Two controllers Two 14drive bay FC drive enclosures Seven 2port enclosure address bus shelf ID expansion cables Eight AC strips Two 0U PDUs in Storage-Centric conguration; two 1U PDUs in Multi-Product conguration

NOTE: Disks must be ordered separately.

22

EVA8x00 congurations

Table 3 Maximum storage capacities for the 2C2D conguration Disk size
72 GB 146 GB 250 GB 300 GB 500 GB

Maximum capacity
2.0 TB 4.0 TB 7.0 TB 8.4 TB 14.0 TB

2C6D congurations
There are two 2C6D congurations: the Storage-Centric (Figure 11) and the Multi-Product (Figure 13). Each conguration provides a maximum storage capacity of 25.2 TB and contains a maximum of 84 disks. These congurations are available in a 42U rack and have two loop switches, two HSV210-A/B controllers, and six drive enclosures. The Storage-Centric conguration can be expanded (by adding drive enclosures) while remaining online. The Multi-Product more easily allows multiple products to be racked with the EVA, but can only be expanded by powering it down to make these expansion modications.

3 4

16359

Figure 11 2C6D Storage-Centric conguration 1. 2. 3. 4. 3U blank Drive enclosures FC switches HSV210-A/B controller pair

The 2C6D Storage-Centric conguration cable routing diagram is located in Figure 12.

4x00/6x00/8x00 Enterprise Virtual Array hardware conguration guide

23

2 1

4 8 5 7 4

3
0177b

Figure 12 EVA8x00 2C6D Storage-Centric conguration cable diagram 1. 2. 3. 4. 5. 6. 7. 8. ID port 14 Top terminator Drive enclosure FC switches HSV210-A/B controller pair Bottom terminator Y cable Dual controller interconnect cable

24

EVA8x00 congurations

3 4 3

16355

Figure 13 2C6D Multi-Product conguration 1. 2. 3. 4. 5. 3U blank Drive enclosures FC switches HSV210-A/B controller pair Power distribution units

The 2C6D Multi-Product conguration cable routing diagram is located in Figure 14.

4x00/6x00/8x00 Enterprise Virtual Array hardware conguration guide

25

1 6 2 7 8 3 4 6 5 9
16356

Figure 14 EVA8x00 2C6D Multi-Product conguration cable diagram 1. 2. 3. 4. 5. 6. 7. 8. 9. Top terminator ID port 8 Dual controller interconnect cable Y cable Bottom terminator Drive enclosures FC switches HSV210-A/B controller pair Power distribution units

2C6D features
The following features are included in the 2C6D: One storage rack Two controllers Six 14drive bay FC drive enclosures Four FC loop switches Seven 2port enclosure address bus shelf ID expansion cables Eight AC strips Two 0U PDUs in Storage-Centric conguration; two 1U PDUs in Multi-Product conguration

NOTE: Disks must be ordered separately. The 2C6D conguration can contain 84 disk drives has and a maximum storage capacity of 25.2 TB. See Table 4.

26

EVA8x00 congurations

Table 4 Maximum storage capacities for the 2C6D conguration Disk size
72 GB 146 GB 250 GB 300 GB 500 GB

Maximum capacity
6.0 TB 12.0 TB 21.0 TB 25.2 TB 42.0 TB

2C12D conguration
The 2C12D conguration provides a maximum storage capacity of 50.4 TB. This conguration can contain a maximum of 168 disks. This conguration is available in a 42U rack and has two HSV210-A/B controllers, twelve drive enclosures, and four loop switches.

2 3

16360

Figure 15 2C12D conguration 1. Drive enclosures 2. FC switches 3. HSV210-A/B controller pair The 2C12D cable routing diagram is located in Figure 16.

4x00/6x00/8x00 Enterprise Virtual Array hardware conguration guide

27

2 1

4 8 5 7 4

3
0165b

Figure 16 EVA8x00 2C12D cable diagram 1. 2. 3. 4. 5. 6. 7. 8. ID port 14 Top terminator Drive enclosure FC switches HSV210-A/B controller pair Bottom terminator Y cable Dual controller interconnect cable

2C12D features
The following features are included with the 2C12D conguration: One storage rack Two controllers 12 14drive bay FC drive enclosures Four FC loop switches Seven 2port enclosure address bus shelf ID expansion cables Eight AC strips Two 0U PDUs

NOTE: Disks must be ordered separately.

28

EVA8x00 congurations

Table 5 Maximum storage capacities for the 2C12D conguration Disk size
72 GB 146 GB 250 GB 300 GB 500 GB

Maximum capacity
12.0 TB 24.0 TB 42.0 TB 50.4 TB 84.0 TB

4x00/6x00/8x00 Enterprise Virtual Array hardware conguration guide

29

30

EVA8x00 congurations

3 EVA6x00 congurations
This chapter discusses the standard EVA6x00 congurations. Each section describes the placement of HSV controllers, drive enclosures, enclosure address bus shelf ID expansion cables, and copper Fibre Channel cables. NOTE: The congurations described in this guide are the preferred congurations. Other congurations may be used, but ensure that enclosure ID 7 is not used for any disk enclosure.

2C4D conguration
The 2C4D conguration provides a maximum storage capacity of 16.8 TB. This conguration can contain a maximum of 56 disks. This conguration is available in a 42U, 41U, 36U, 33U, 25U, or 22U rack and has two HSV200-A/B controllers, four drive enclosures, and two loop switches.

Figure 17 2C4D conguration 1. 2. 3. 4. 3U blank FC switches HSV200-A/B controller pair Drive enclosures

The 2C4D cable routing diagram is located in Figure 18.

4x00/6x00/8x00 Enterprise Virtual Array hardware conguration guide

31

1 6 2 5 3

0170b

Figure 18 EVA6x00 2C4D cable diagram 1. 2. 3. 4. 5. 6. 7. 8. FC switches HSV200-A/B controller pair Drive enclosure Bottom terminator Dual controller interconnect cable Y cable ID port 10 Top terminator

2C4D features
The following features are included with the 2C4D conguration: One storage rack Four 14drive bay FC drive enclosures One pair of FC-AL loop switches One 2port enclosure address bus shelf ID expansion cable Six AC strips Two 1U PDUs (not shown in gure)

NOTE: Disks must be ordered separately.

32

EVA6x00 congurations

Table 6 Maximum storage capacities for the 2C4D conguration Disk size
72 GB 146 GB 250 GB 300 GB 500 GB

Maximum capacity
4.0 TB 8.1 TB 14.0 TB 16.8 TB 28.0 TB

2C5D conguration
The 2C5D conguration provides a maximum storage capacity of 21.0 TB. This conguration can contain a maximum of 70 disks. This conguration is available in a 42U, 41U, 36U, 33U, 25U, or 22U rack and has two HSV200-A/B controllers, ve drive enclosures, and two loop switches.

Figure 19 2C5D conguration 1. 2. 3. 4. 3U blank Drive enclosures Switch HSV200-A/B controller pair

The 2C5D cable routing diagram is located in Figure 20.

4x00/6x00/8x00 Enterprise Virtual Array hardware conguration guide

33

1 6

2
3

1
0169b

Figure 20 EVA6x00 2C5D cable diagram 1. 2. 3. 4. 5. 6. 7. 8. Drive enclosure FC switches HSV200-A/B controller pair Bottom terminator Dual controller interconnect cable Y cable ID port 10 Top terminator

2C5D features
The following features are included with the 2C5D conguration: One storage rack Five 14drive bay FC drive enclosures One pair of FC-AL loop switches One 2port enclosure address bus shelf ID expansion cable Six AC strips Two 1U PDUs (not shown in gure)

NOTE: Disks must be ordered separately.

34

EVA6x00 congurations

Table 7 Maximum storage capacities for the 2C5D conguration Disk size
72 GB 146 GB 250 GB 300 GB 500 GB

Maximum capacity
5.0 TB 10.0 TB 17.5 TB 21.0 TB 35.0 TB

2C6D conguration
The 2C6D conguration provides a maximum storage capacity of 25.2 TB. This conguration can contain a maximum of 84 disks. This conguration is available in a 42U, 41U, 36U, 33U, or 25U rack, and has two HSV200-A/B controllers, six drive enclosures, and four loop switches.

Figure 21 2C6D conguration 1. 2. 3. 4. 3U blank Drive enclosures FC switches HSV200-A/B controller pair

The 2C6D cable routing diagram is located in Figure 22.

4x00/6x00/8x00 Enterprise Virtual Array hardware conguration guide

35

7 1
6

2 3

1
0168b

Figure 22 EVA6x00 2C6D cable diagram 1. 2. 3. 4. 5. 6. 7. 8. Drive enclosure FC switches HSV200-A/B controller pair Bottom terminator Dual controller interconnect cable Y cable ID port 10 Top terminator

2C6D features
The following features are included with the 2C6D conguration: One storage rack Six 14drive bay FC drive enclosures One pair of FC-AL loop switches One 2port enclosure address bus shelf ID expansion cable Six AC strips Two 1U PDUs (not shown in gure)

NOTE: Disks must be ordered separately.

36

EVA6x00 congurations

Table 8 Maximum storage capacities for the 2C6D conguration Disk size
72 GB 146 GB 250 GB 300 GB 500 GB

Maximum capacity
6.0 TB 1.0 TB 21.0 TB 25.2 TB 42.0 TB

2C7D conguration
The 2C7D conguration provides a maximum storage capacity of 29.4 TB. This conguration can contain a maximum of 98 disks. This conguration is available in a 42U, 41U, 36U, or 33U rack and has two HSV200-A/B controllers, seven drive enclosures, and two loop switches.

Figure 23 2C7D conguration 1. 2. 3. 4. 3U blank Drive enclosures FC switches HSV200-A/B controller pair

The 2C7D cable routing diagram is located in Figure 24.

4x00/6x00/8x00 Enterprise Virtual Array hardware conguration guide

37

2 6 3 5

1
0167b

Figure 24 EVA6x00 2C7D cable diagram 1. 2. 3. 4. 5. 6. 7. 8. Drive enclosure FC switches HSV200-A/B controller pair Bottom terminator Dual controller interconnect cable Y cable ID port 10 Top terminator

2C7D features
The following features are included with the 2C7D conguration: One storage rack Seven 14drive bay FC drive enclosures One pair of FC-AL loop switches One 2port enclosure address bus shelf ID expansion cable Six AC strips Two 1U PDUs (not shown in gure)

NOTE: Disks must be ordered separately.

38

EVA6x00 congurations

Table 9 Maximum storage capacities for the 2C7D conguration Disk size
72 GB 146 GB 250 GB 300 GB 500 GB

Maximum capacity
7.0 TB 14.0 TB 24.5 TB 29.4 TB 49.0 TB

2C8D conguration
The 2C8D conguration provides a maximum storage capacity of 33.6 TB. This conguration can contain a maximum of 112 disks. This conguration is available in a 42U, 41U, 36U, or 33U rack and has two HSV200-A/B controllers, eight drive enclosures, and two loop switches.

Figure 25 2C8D conguration 1. 2. 3. 4. 3U blank Drive enclosures FC switches HSV200-A/B controller pair

The 2C8D cable routing diagram is located in Figure 26.

4x00/6x00/8x00 Enterprise Virtual Array hardware conguration guide

39

8 1 7

2 6 3 5

1
0166b

Figure 26 EVA6x00 2C8D cable diagram 1. 2. 3. 4. 5. 6. 7. 8. Drive enclosure FC switches HSV200-A/B controller pair Bottom terminator Dual controller interconnect cable Y cable ID port 10 Top terminator

2C8D features
The following features are included with the 2C8D conguration: One storage rack Eight 14drive bay FC drive enclosures One pair of FC-AL loop switches One 2port enclosure address bus cable Six AC strips Two 1U PDUs (not shown in gure)

NOTE: Disks must be ordered separately.

40

EVA6x00 congurations

Table 10 Maximum storage capacities for the 2C8D conguration Disk size
72 GB 146 GB 250 GB 300 GB 500 GB

Maximum capacity
8.0 TB 16.0 TB 28.0 TB 33.6 TB 56.0 TB

4x00/6x00/8x00 Enterprise Virtual Array hardware conguration guide

41

42

EVA6x00 congurations

4 EVA4x00 congurations
This chapter briey discusses the standard EVA4x00 congurations. Each section describes the placement of HSV controllers, drive enclosures, enclosure address bus shelf ID expansion cables, and copper Fibre Channel cables. NOTE: The congurations described in this guide are the preferred congurations. Other congurations may be used, but ensure that enclosure ID 7 is not used for any disk enclosure.

2C1D conguration
The 2C1D conguration provides a maximum storage capacity of 4.2 TB. This conguration can contain a maximum of 14 disks. This conguration is available in a 42U, 41U, 36U, 33U, 25U, or 22U rack and has two HSV200-A/B controllers and one drive enclosure.

Figure 27 2C1D conguration 1. 3U blank 2. HSV200-A/B controller pair 3. Drive enclosure The 2C1D cable routing diagram is located in Figure 28.

4x00/6x00/8x00 Enterprise Virtual Array hardware conguration guide

43

Figure 28 EVA4x00 2C1D cable diagram 1. 2. 3. 4. 5. 6. 7. HSV200-A/B controller pair Drive enclosure Bottom terminator Dual controller interconnect cable Y cable ID port 6 Top terminator

2C1D features
The following features are included with the 2C1D conguration: One storage rack One 14drive bay FC drive enclosures One 2port enclosure address bus shelf ID expansion cable Six AC strips Two 1U PDUs (not shown in gure)

NOTE: Disks must be ordered separately.

Table 11 Maximum storage capacities for the EVA4x00 2C1D conguration Disk size
72 GB 146 GB 250 GB 300 GB 500 GB

Maximum capacity
1 TB 2 TB 3.5 TB 4.2 TB 7.0 TB

44

EVA4x00 congurations

2C2D conguration
The 2C2D conguration provides a maximum storage capacity of 8.4 TB. This conguration can contain a maximum of 28 disks. This conguration is available in a 42U, 41U, 36U, 33U, 25U, or 22U rack and has two HSV200-A/B controllers and two drive enclosures.

Figure 29 2C2D conguration 1. 3U blank 2. HSV200-A/B controller pair 3. Drive enclosures The 2C2D cable routing diagram is located in Figure 30.

4x00/6x00/8x00 Enterprise Virtual Array hardware conguration guide

45

7 6

5
1

4 3

2 2
0173b

Figure 30 EVA4x00 2C2D cable diagram 1. 2. 3. 4. 5. 6. 7. HSV200-A/B controller pair Drive enclosure Bottom terminator Dual controller interconnect cable Y cable ID port 6 Top terminator

2C2D features
The following features are included with the 2C2D conguration: One storage rack Two 14drive bay FC drive enclosures One 2port enclosure address bus shelf ID expansion cable Six AC strips Two 1U PDUs (not shown in gure)

NOTE: Disks must be ordered separately. Table 12 Maximum storage capacities for the 2C2D conguration Disk size
72 GB 146 GB 250 GB 300 GB 500 GB

Maximum capacity
2.0 TB 4.0 TB 7.0 TB 8.4 TB 14.0 TB

46

EVA4x00 congurations

2C3D conguration
The 2C3D conguration provides a maximum storage capacity of 12.6 TB. This conguration can contain a maximum of 42 disks. This conguration is available in a 42U, 41I, 36U, 33U, 25U, or 22U rack and has two HSV200-A/B controllers and three drive enclosures.

Figure 31 2C3D conguration 1. 3U blank 2. HSV200-A/B controller pair 3. Drive enclosures The 2C3D cable routing diagram is located in Figure 32

4x00/6x00/8x00 Enterprise Virtual Array hardware conguration guide

47

7 6

5 1 4 3 2
0172b

Figure 32 EVA4x00 2C3D cable diagram 1. 2. 3. 4. 5. 6. 7. HSV200-A/B controller pair Drive enclosure Bottom terminator Dual controller interconnect cable Y cable ID port 6 Top terminator

2C3D features
The following features are included with the 2C3D conguration: One storage rack Three 14drive bay FC drive enclosures One 2port enclosure address bus shelf ID expansion cable Six AC strips Two 1U PDUs (not shown in gure)

NOTE: Disks must be ordered separately. Table 13 Maximum storage capacities for the 2C3D conguration Disk Size
72 GB 146 GB 250 GB 300 GB 500 GB

Maximum Capacity
3.0 TB 6.1 TB 10.5 TB 12.6 TB 21.0 TB

48

EVA4x00 congurations

2C4D conguration
The 2C4D conguration provides a maximum storage capacity of 16.8 TB. This conguration can contain a maximum of 56 disks. This conguration is available in a 42U, 41U, 36U, 33U, 25U, or 22U rack and has two HSV200-A/B controllers and four drive enclosures.

Figure 33 2C4D conguration 1. 3U blank 2. HSV200-A/B controller pair 3. Drive enclosures The 2C4D cable routing diagram is located in Figure 34.

4x00/6x00/8x00 Enterprise Virtual Array hardware conguration guide

49

7 6

5 1 4 2

2
0171b

Figure 34 EVA4x00 2C4D cable diagram 1. 2. 3. 4. 5. 6. 7. HSV200-A/B controller pair Drive enclosure Bottom terminator Dual controller interconnect cable Y cable ID port 6 Top terminator

2C4D features
The following features are included with the 2C4D conguration: One storage rack Four drive bay FC drive enclosures One 2port enclosure address bus shelf ID expansion cable Six AC strips Two 1U PDUs (not shown in gure)

NOTE: Disks must be ordered separately.

50

EVA4x00 congurations

Table 14 Maximum storage capacities for the 2C4D conguration Disk size
72 GB 146 GB 250 GB 300 GB 500 GB

Maximum capacity
4.0 TB 8.0 TB 14.0 TB 16.8 TB 28.0 TB

4x00/6x00/8x00 Enterprise Virtual Array hardware conguration guide

51

52

EVA4x00 congurations

A Specications
This appendix denes the physical, environmental, and power specications of the EVA 4x00/6x00/8x00 storage systems. The following topics are included: Physical specications Environmental specications Power specications

Physical specications
This section describes the physical specications of the drive enclosure and elements. Table 15 denes the dimensions and weights of the storage system components. Table 15 Enterprise Virtual Array 4x00/6x00/8x00 Product Dimensions, Weight and Clearance Physical Dimensions
EVA4x00/8x00 2C2D (42U rack) EVA6x00/8x00 2C6D (42U rack) EVA8x00 2C12D (42U rack) EVA4x00/6x00/ 8x00 Controller Assembly M5314B/ M5314C Drive Enclosure

Height in/cm
78.75 (200.03) 78.75 (200.03) 78.75 (200.03) 7.0/17.78 5.25/ 13.34

Width in/cm
23.7 (60.3) 23.7 (60.3) 23.7 (60.3) 17.6/ 44.70 19.0/ 42.26

Depth in/cm
40.2 (102.2) 40.2 (102.2) 40.2 (102.2) 27.5/69.85

Max Weight lb/kg


537 (244.1) 854 (308.2) 1290 (586.4 120/54.55

Req. Front Clearance in/cm


30 (76.2) 30 (76.2) 30 (76.2) N/A

Req. Rear Clearance in/cm


30 (76.2) 30 (76.2) 30 (76.2) N/A

20/50.8

71/32.21

N/A

N/A

Environmental specications
To ensure optimum product operation, you must maintain the operational environmental specications listed in Table 16. The ambient temperature (the enclosure air intake or room temperature) is especially critical.

4x00/6x00/8x00 Enterprise Virtual Array hardware conguration guide

53

Table 16 Environmental specications


Operating Temperature Shipping Temperature Humidity Shipping Humidity Altitude Air Quality 50 to 95 F (10 to 35 C) - Reduce rating by 1 F for each 1000 ft altitude (1.8 C/1,000 m) -40 to 150 F (-40 to 66 C) 10% to 90% non-condensing 5% to 90% non-condensing Up to 8,000 ft (2,400 m) Not to exceed 500,000 particles per cubic foot of air at a size of 0.5 micron or larger

Power specications
The input voltage is a function of the country-specic input voltage to Enterprise storage system rack power distribution units (PDUs). Enterprise storage system AC input line voltages denes the AC input power available to the drive enclosure power supplies. CAUTION: The AC power distribution within a rack ensures a balanced to each PDA and reduces the possibility of an overload condition. Changing the cabling to or from a PDM could cause an overload condition. Table 17 Enterprise storage system AC input line voltages Specication
AC Line Voltage AC Line VoltageJapan AC Line VoltageNorth America AC Line VoltageEurope AC Line Frequency AC Line VoltageJapan AC Line VoltageNorth America AC Line VoltageNorth America AC Line VoltageEurope

Minimal 60 Hz service
57 Hz 180 VAC 180 VAC 208 VAC 50 Hz service 47 Hz 180 VAC 190 VAC 200 VAC 208 VAC

Nominal
60 Hz 202 VAC 208 VAC 240 VAC

Maximum
63 Hz 220 VAC 220 VAC 254 VAC

50 Hz 202 VAC 220 VAC 230 VAC 240 VAC

53 Hz 220 VAC 235 VAC 244 VAC 254 VAC

54

Specications

Table 18 Power Data (North America/Europe/Japan) maximum conguration


AC plug type (quantity 2) Number of phases Rated current Nominal Line Voltage Range Line Voltage Line Frequency North America 3 wire NEMA No. L6-30P, 30 amp (208 to 240V, 5060Hz, 30A) Europe 3 wire, 2 pole IEC 309, 30 amp, (220 to 240V, 50Hz, 32A) Single 17A @ 200V-240V AC, 60Hz total, 4.25 A per power cord North America 208 or 230V Europe 230V Japan 206V 187 to 256V North America 60Hz, Europe 50Hz, Japan 50 or 60 Hz

Table 19 EVA4x00 power specications 208 Volts Specication


Total System Wattage Typical1 Total System BTU/hour Input Current (A) Typical per system In Rush Current (A) Failover Mode Input Current (A) - Maximum per system

2C1D
638 1729 1.6 98 2.7

2C2D
1013 3014 2.6 132 4.3

2C3D
1390 4300 3.5 170 5.9

2C4D
1767 5585 4.4 220 7.5

1 Typical is described as a system in normal steady state operation (that is, both PDUs operating normally, the array

reading/writing to disk drives in a production environment).

This data represents fully populated drive enclosures with 15K RPM disk drives. Other drive types may vary slightly. For example, if you are using 10K RPM drives, the power specications will be approximately 20% less than the 15K RPM drives.

Table 20 EVA4x00 power specications 230 Volts Specication


Total System Wattage Typical1 Total System BTU/hour Input Current (A) Typical per system In Rush Current (A) Failover Mode Input Current (A) - Maximum per system

2C1D
638 1729 1.5 104 2.6

2C2D
1013 3014 2.4 147 4.1

2C3D
1390 4300 3.3 190 5.5

2C4D
1767 5585 4.2 244 7.1

1 Typical is described as a system in normal steady state operation (that is, both PDUs operating normally, the array reading/writing to disk drives in a production environment).

This data represents fully populated drive enclosures with 15K RPM disk drives. Other drive types may vary slightly. For example, if you are using 10K RPM drives, the power specications will be approximately 20% less than the 15K RPM drives.

4x00/6x00/8x00 Enterprise Virtual Array hardware conguration guide

55

Table 21 EVA6x00 power specications 208 Volts Specication


Total System Wattage Total System BTU/hour Typical1 Input Current (A) - Typical per system In Rush Current (A) Failover Mode Input Current (A) - Maximum per system

2C4D
1837 6268 4.6 220 7.8

2C5D
2214 7553 5.5 250 9.4

2C6D
2590 8838 6.5 280 11.0

2C7D
2967 10124 7.4 321 12.6

2C8D
3344 11409 8.4 363 14.2

1 Typical is described as a system in normal steady state operation (that is, both PDUs operating normally, the array

reading/writing to disk drives in a production environment).

This data represents fully populated drive enclosures with 15K RPM disk drives. Other drive types may vary slightly. For example, if you are using 10K RPM drives, the power specications will be approximately 20% less than the 15K RPM drives.

Table 22 EVA6x00 power specications 230 Volts Specication


Total System Wattage Total System BTU/hour Typical1 Input Current (A) - Typical per system In Rush Current (A) Failover Mode Input Current (A) - Maximum per system

2C4D
1837 6268 4.3 244 7.3

2C5D
2214 7553 5.2 272 8.8

2C6D
2590 8838 6.1 311 10.0

2C7D
2967 10124 7.0 357 11.9

2C8D
3344 11409 7.9 403 13.3

1 Typical is described as a system in normal steady state operation (that is, both PDUs operating normally, the array

reading/writing to disk drives in a production environment).

This data represents fully populated drive enclosures with 15K RPM disk drives. Other drive types may vary slightly. For example, if you are using 10K RPM drives, the power specications will be approximately 20% less than the 15K RPM drives.

56

Specications

Table 23 EVA8x00 power specications 208 Volts Specication


Total System Wattage Total System BTU/hour Typical1 Input Current (A) - Typical per system In Rush Current (A) Failover Mode Input Current (A) - Maximum per system

2C2D
1153 3936 2.9 132 4.9

2C6D
2660 9077 6.7 280 11.3

2C8D
3414 11648 8.5 363 14.5

2C10D
4167 14218 10.4 451 17.7

2C12D
4920 16789 12.3 528 20.8

1 Typical is described as a system in normal steady state operation (that is, both PDUs operating normally, the array

reading/writing to disk drives in a production environment).

This data represents fully populated drive enclosures with 15K RPM disk drives. Other drive types may vary slightly. For example, if you are using 10K RPM drives, the power specications will be approximately 20% less than the 15K RPM drives.

Table 24 EVA8x00 power specications 230 Volts Specication


Total System Wattage Total System BTU/hour Typical1 Input Current (A) - Typical per system In Rush Current (A) Failover Mode Input Current (A) - Maximum per system

2C2D
1153 3936 2.7 147 4.6

2C6D
2660 9077 6.3 311 10.6

2C8D
3414 11648 8.1 403 13.7

2C10D
4167 14218 9.8 500 16.7

2C12D
4920 16789 11.6 586 19.7

1 Typical is described as a system in normal steady state operation (that is, both PDUs operating normally, the array

reading/writing to disk drives in a production environment).

This data represents fully populated drive enclosures with 15K RPM disk drives. Other drive types may vary slightly.

4x00/6x00/8x00 Enterprise Virtual Array hardware conguration guide

57

58

Specications

B Low-voltage Japanese cabinets


General description
This specication describes HP's requirements for low voltage EVA storage cabinets. These low voltage cabinets are congured with two redundant sets of PDUs in order to provide system required power. Each PDU set is limited to 2550 W at a minimum voltage of 108. Each PDU is limited to one power strip to limit the number of EVA component attachment to eight components per power PDU. Power strip additions will likely overload the PDU systems.

Reference documents
Reference documents are for informational purposes only. No requirement is implied by the inclusion or exclusion of reference documents. ANSI/EIA-310-D-1992, Cabinets, Racks, Panels and Associated Equipment EN60950:2000, Safety of Information Technology Equipment FCC Part 15 Code of Federal Regulations, Title 47, FCC Part 15 Radio Frequency Devices, Subpart B, Unintentional Radiators EN55022 (1998), Limits and Methods of Measurement of Radio Interference Characteristics of Information Technology Equipment EN55024 (1998), Information Technology Equipment Immunity Characteristics and Methods of Measurement EN61000, Electromagnetic Compatibility CAN/CSA-C22.2 No. 60950-00/3rd Edition, Safety of Information Technology Equipment All brands, names, trademarks and logos are the property of their respective owners.

Power congurations
There are two power congurations: the AD572A and the AD573A. The AD572A uses the HP StorageWorks 42U Low-voltage cabinet (Figure 35) and the AD573A uses the HP StorageWorks 36U Low-voltage cabinet (Figure 36).

4x00/6x00/8x00 Enterprise Virtual Array hardware conguration guide

59

42 U 41 U 40 U 39 U 38 U 37 U 36 U 35 U 34 U 33 U 32 U 31 U 30 U 29 U 28 U 27 U 26 U 25 U 24 U 23 U 22 U 21 U 20 U 19 U 18 U 17 U 16 U 15 U 14 U 13 U 12 U 11 U 10 U 09 U 08 U 07 U 06 U 05 U 04 U 03 U 02 U 01 U 0156a

Figure 35 HP StorageWorks 42U low-voltage cabinet

36 U 35 U 34 U 33 U 32 U 31 U 30 U 29 U 28 U 27 U 26 U 25 U 24 U 23 U 22 U 21 U 20 U 19 U 18 U 17 U 16 U 15 U 14 U 13 U 12 U 11 U 10 U 09 U 08 U 07 U 06 U 05 U 04 U 03 U 02 U 01 U 0157a

Figure 36 HP StorageWorks 36U low-voltage cabinet

Specications
This section contains information on: EVA cabinet footprint Weights and dimensions of the low-voltage cabinets Center of gravity and stability Torque specications Environmental specications Electrical specications

60

Low-voltage Japanese cabinets

EVA cabinet footprint


Figure 37 shows the dimensions of the EVA cabinet footprint.
23.73"

60.96"

37.46"

90

0158a

Figure 37 EVA cabinet footprint

Weights and dimensions


Table 25 shows the weights and dimensions for the 42U low-voltage cabinet. Table 26 shows the same information for the 36U low-voltage cabinet. Table 25 HP StorageWorks 42U low-voltage cabinet Weight lbs
Assembly Packaged Assy 254 367

Height in
78.85 84.63

Width in
23.73 35.50

Depth in
40.22 46.50

Table 26 HP StorageWorks 36U low-voltage cbinet Weight lbs


Assembly Packaged Assy NA NA

Height in
68.35 68.76

Width in
23.73 35.50

Depth in
40.22 46.50

Center of gravity
Table 27 shows the center of gravity measurements for the 42U low-voltage cabinet. Table 28 shows the same information for the 36U low-voltage cabinet. The center of gravity of the assemblies is measured from the front mounting face of the vertical mounting rails, the top inside surface of the cabinet base, and the center of the cabinet (1.5 inches).

4x00/6x00/8x00 Enterprise Virtual Array hardware conguration guide

61

Table 27 Center of gravity measurements 42U low-voltage cabinet Measurement


Depth from mounting face of vertical mounting rails Height from inside base Distance from cabinet center (viewing front of cabinet) 16.56 37.09 0.46 (left of center line)

Inches

Table 28 Center of gravity measurements 36U low-voltage cabinet Measurement


Depth from mounting face of vertical mounting rails Height from inside baseNA Distance from cabinet center (viewing front of cabinet) NA NA NA

Inches

Tip stability
The system must pass tip stability testing for a 10 tip test and 250N side-force tip test per CAN/CSA-C22.2 No. 60950-00/3rd Edition, Safety of Information Technology Equipment. Results of tip and tilt calculations show that the testing of this conguration is not necessary. Center of gravity locations, within the 10 boundaries show no danger of tip. Force tip testing calculations indicate that the rear force tip test need not be performed.

62

Low-voltage Japanese cabinets

Index
2C2D conguration describing features, 22, 46 36U rack, 13 42U rack, 13

Symbols

O P

opal rack, 13

controller dened, 16 conventions document, 9 text symbols, 10 customer self repair, 11

physical specications enclosures, 53 power specications drive enclosure, 54 prerequisites, 9

rack stability warning, 10

document conventions, 9 prerequisites, 9 documentation providing feedback, 11

enclosures, physical specications, 53 environmental specications drive enclosure, 53

SFP, 15 specications physical, 53 power, 54 storage racks, 13, 13 Subscriber's Choice, HP, 11 symbols in text, 10

FC drive enclosures describing features, 13 FC loop switches describing features, 14 Fibre Channel drive enclosure, 13

technical support HP, 10 service locator website, 11 text symbols, 10 topology, 14 transceivers, 15

help obtaining, 10 HP technical support, 10 HSV Controllers dened, 16

warning rack stability, 10 websites customer self repair, 11 HP , 11 HP Subscriber's Choice for Business, 11

loop topology, 14

4x00/6x00/8x00 Enterprise Virtual Array hardware conguration guide

63

S-ar putea să vă placă și