Sunteți pe pagina 1din 2

Page 4 2006-01

Page 1 2006-01

Because the viscosity reduces with increasing temperature, oil with a higher basic viscosity (ISO VG150/220) should be used in the dryer section.

Operating manual for installation of Control Valve SV 90


General data:

Wet section Mobil DTE 24 Technical specifications:


Density at 15C, g/cm3 Flash point C Pour point C Viscosity index Viscosity in mm2/s at 40C at 100C Viscosity class ISO

type of valve: material versions: environment:

0.874

200

-30

102

31

5.3

VG 32

Alternative: SHELL ASEOL PLUS 32

max. air pressure: air preparation: (strictly recommended) Installation: 1.

SV 90 -aluminium, -stainless steel -heat resistant up to 150C -resistant against acids and leaches (stainlesssteel-version) 4 bar cleaned, filtered, oiled

Dry section Mobil Pyrolube 830 Technical specifications:


Density at 15C, g/cm3 Flash point C Pour point C Viscosity index Viscosity in mm2/s at 40C at 100C Viscosity class ISO

0.930

270

-46

132

190

21

VG 150/220

If Control Valve is installed in a horizontal position (direction of camshaft) the Sensor Paddle should be rotated away from the fabric and one can insert the stop pin into the drilling in the housing. This allows the Sensor Paddle to lie against the stop pin.
PHONE FAX PHONE FAX 00423 - 375 82 82 00423 - 375 82 99 001-757 485 4371 001-757 485 4473

JUD AG LIECHTENSTEIN
JUD CORPORATION CHESAPEAKE VA.

PHONE FAX PHONE FAX

00423 - 375 82 82 00423 - 375 82 99 001-757 485 4371 001-757 485 4473

JUD AG LIECHTENSTEIN
JUD CORPORATION CHESAPEAKE VA.

Page 2 2006-01

Page 3 2006-01

2.

3.

4.

Revolving the camshaft making sure that the red marks (of guide disk and housing) are corresponding. When installing the Control Valve it has to be placed that the fabric touches the middle of the Paddle and 16 zero position is achieved. (hint: for more aggressive and quicker reaction positioning further to top of Paddle, for more smooth and slower reaction positioning down to bottom of Paddle) Remove stop pin.

Service Unit

Control Valve SV 90

Exhaust air

Manometer Filter

Oiler Bellow guide

1. horizontal arrangement

2. red marks corresponding more aggresive reaction

Recommended lubricant for Service Unit and Control Valve: Because the viscosity of the oil changes, oil appropriate to the operating area should be used. Hydraulic oil to DIN 51524-HLP of viscosity class ISO VG32 is recommended. These oils have a basic viscosity (at 40C) of 32 mm2/s and are suitable for use in the wet section.

3. middle of paddle; 16 zero position smooth reaction

JUD AG LIECHTENSTEIN
JUD CORPORATION CHESAPEAKE VA.

PHONE FAX PHONE FAX

00423 - 375 82 82 00423 - 375 82 99 001-757 485 4371 001-757 485 4473

JUD AG LIECHTENSTEIN
JUD CORPORATION CHESAPEAKE VA.

PHONE FAX PHONE FAX

00423 - 375 82 82 00423 - 375 82 99 001-757 485 4371 001-757 485 4473