Sunteți pe pagina 1din 92

www.moeller.

net

Intreruptoare automate de putere pana la 6300 A

Catalog suplimentar 2009

Intreruptoare automate IZMX16, IZM26

Caracteristici tehnice Intreruptor automat IZMX16, Intreruptor separator INX16


IZMX16, INX16
Icu/Ics la Ue = 440/690 V c.a. Icu: Capacitate nominala de rupere limita la scurt-circuit la tensiunea nominala de utilizare Ue Ics: Capacitatea nominala de rupere de serviciu la scurt-circuit, la tensiunea nominala de utilizare Ue Capacitate de rupere de baza (B) Capacitate de rupere normala (N) Capacitate de rupere ridicata (H)

440 V Intreruptor automat IZMX16 630 1600 42/42 Curent nominal In A Icu / Ics kA

690 V Icu / Ics kA 42/42

440 V Icu / Ics kA 50/50

690 V Icu / Ics kA 42/42

440 V Icu / Ics kA 65/50

690 V Icu / Ics kA 42/42

Icw t = 1 s Icw: Curent nominal admisibil de scurta durata

Capacitate de rupere de baza (B) t=1s

Capacitate de rupere normala (N) t=1s Icw kA 42

Capacitate de rupere ridicata (H) t=1s Icw kA 42

Intreruptor automat, Intreruptor separator IZMX16 INX16

Curent nominal In A 630 1600

Icw kA 42

Icm la Ue = 440/690 V AC Icm: Capacitate nominala de inchidere la scurt-circuit la tensiunea nominala de utilizare Ue

Capacitate de rupere de baza (B) 440/690 V c.a.

Capacitate de rupere normala (N) 440/690 V c.a. Icm kA 88,2

Capacitate de rupere ridicata (H) 440/690 V c.a. Icm kA 88,2

Intreruptor separator INX16

Curent nominal In A 630 1600

Icm kA 88,2

Caracteristici functionale Declansatoare electronice pentru intreruptoare automate IZMX16


IZMX16...
IZMX16...V... Protectie selectiva DTV Digitrip 520 LSI(G) IZMX16...U... Protectie universala DTU Digitrip 520M LSI(G)

Domeniu curent Masurare valoare efectiva (RMS) Functii protectie Generale Optiuni Fisa curent nominal (In) Declansare supratemperatura Protectie suprasarcina Domeniu reglaj declansare suprasarcina Temporizare tr la 6 x Ir Memorie termica Protectie scurtcircuit temporizata Domeniu reglaj protectie scurtcircuit temporizata Temporizare tsd la 8 x Ir, caracteristica i2t Temporizare, caracteristica palier Temporizare cu selectivitate zonala ZSI1) Protectie la scurtcircuit instantanee Domeniu protectie la scurtcircuit instantanee Deconectabila (OFF) Declansare la inchidere (MCR) Optiuni protectie la defect cu pamantul Alarma la defect cu pamantul Declansare la defect cu pamantul Temporizare Ig la 0,625 x In, caracteristica i2t Temporizare, caracteristica palier Selectivitate zonala ZSI la defecte cu pamantul ZSI1) Memorie termica la defecte cu pamantul Protectie neutru Diagnoza Stare/ suprasarcina cu LED Afisare cauza declansare cu LED Curentul in momentul declansarii Contact semnalizare la distanta declansare/ alarmare la defect cu pamantul Contact la distanta "sarcina crescuta" Supraveghere Afisaj digital Comunicare pe magistrala Functii suplimentare Testare 2) ARMS (Arcflash Reduction Maintenance System) Indicatii

200 A 1600 A K

200 A 1600 A K

LSI, LSIG K K L 0,5 - 1,0 x (In) 2 - 24 s K S 200 - 1000 % x (Ir) 100 - 500 ms 100 - 500 ms k I 200 - 1200 % x (In) K K G 25 - 100 % x (In)3) 100 - 500 ms 100 - 500 ms k K K K K Aparat manual ln = Rating Plug (fisa curent nominal) =Transformator curent nominal; lr = Selector reglaj valori (declansare suprasarcina) 1) Este necesara o sursa de alimentare externa de 24 V c.c. a circuitelor de comanda 2) Tester de mana pentru simulare curent secundar 3) In combinatii cu functia ARMS este limitat la 1200 A

LSI, LSIG, LSIA K K 0,5 - 1,0 x (In) 2 - 24 s K 200 - 1000 % x (Ir) 100 - 500 ms 100 - 500 ms k 200 - 1200 % x (In) K K k1) 25 - 100 % x (In)3) 100 - 500 ms 100 - 500 ms k K K K K K1) K1) K1) LCD 4 caractere optional: Modbus, Profibus Aparat manual k1) K Standard k Optional

Componentele sistemului Intreruptor automat IZMX16


IZMX16

3 2 12

11

10

An Eaton

Brand

Componentele sistemului Intreruptor automat IZMX16


IZMX16
Intreruptor automat IZMX16 a pag 8 1 Rama de etansare Inclusa in livrare Declansator electronic (Digitrip 520M) Nu poate fi comandat separat! Declansator deschidere a pag 11 Declansator de minima tensiune a pag 12 Contact semnalizare declansare Contact semnalizare declansare (OTS), 2 comutatoare a pag 13 Electromagnet de inchidere a pag 11 7

Racorduri principale 2 Racord universal, 3 si 4 poli orizontal/ vertical a pag 16 Caseta pentru unitati debrosabile 3 Caseta 1600 A cu sau fara conector circuite de comanda a pag 10 Conector circuite de comanda la alegere 8, 20 sau 30 blocuri a pag 16 Contact auxiliar normal Contact ON/OFF a pag 12 4

10

11

12

Actionare cu motor 6 Armeaza arcurile pentru a permite operarea prin comanda de la distanta sau locala. a pag 10

Codificare IZM IN X16 B N H 3 4 V U 06 08 10 12 16 W F

IZM, IN = Familia de produse Gabarite X16: Intreruptor compact, 630 - 1600 A Capacitate de rupere B = Baza N = Normala H = Ridicata 3-poli 4-poli Caracteristici de declansare V = Protectie selectiva

= Digitrip 520 LSI(G)


U = Protectie universala

= Digitrip 520MC LSI(G)


Curent nominal 06: 630 A 08: 800 A 10: 1000 A 12: 1250 A 16: 1600 A Constructie W = debrosabil F = fix

Prezentare generala Intreruptoare automate in aer IZMX16, Intreruptoare-separatoare INX16


IZMX16, INX16

IZMX16: Dimensiuni reduse de gabarit Conceptul inovativ al intreruptorului automat IZMX16 face posibila instalarea a doua intreruptoare automate debrosabile unul langa altul intr-o sectiune de latime 600 mm. Se realizeaza economii si se reduce spatiul necesar. Designul aparatului mai economic si inglobeaza o tehnologie de ultima generatie.

Echipare standard IZMX16 este echipat standard cu un declansator electronic. Montarea standard este pe o placa de montaj orizontala sau pe o traversa orizontala intr-un tablou. IZMX16 poate fi fixat deasemenea si pe o placa de montaj verticala La intreruptoarele tetrapolare, conductorul de nul este pe partea stanga (vedere frontala) Conductorul de nul poate fi incarcat 100 % precum conductorii de faza. Intreruptoarele automate sunt prevazute cu un mecanism de blocare mecanica a inchiderii. Dupa o declansare la suprasarcina, uzual in primul rand sunt analizate cauzele. Dupa ce eroarea este identificata si rectificata mecanismul de blocare mecanica a inchiderii este resetat prin apasarea indicatorului de declansare de culoare rosie aflat in partea din fata a intreruptorului. Optional poate fi comandata functia "Resetare automata". Aceasta permite intreruptorului sa fie pus in functiune imediat de fiecare data cand mecanismul cu arc este retensionat. In aceste aplicatii analiza obligatorie a erorilor este intentionat evitata. Numarul de blocuri de borne auxiliare depinde de accesoriile instalate Daca o caseta este comandata fara intreruptor, aceasta poate fi deja echipata cu un numar maxim de blocuri de borne auxiliare. Pentru economisirea spatiului din tablou, caseta este oferita fara blocuri de borne auxiliare, astfel ca montarea poate fi facuta mai tarziu in instalatie sau dupa o solicitare ulterioara a accesoriilor. Standard sunt 2 contacte comutatoare pentru semnalizarea pozitiei ON/OFF. Un mecanism de codare intre intreruptor si caseta previne combinatiile nepermise ("Rejection Interlock"). Echipare standard extinsa pentru IZMX16 Anumite articole comandate in trecut, nu mai pot fi gasite acum, caci sunt continute in livrarea standard: Rama de etansare este acum intodeauna inclusa in livrare . La variantele debrosabile aceasta este livrata cu caseta. Capac peste camerele de stingere pentru varianta debrosabila. Intreruptorul automat poate fi scos si verificata camera de stingere. La variantele fixe, se recomanda lasarea unui spatiu deasupra intreruptorului suficient pentru verificarea camerei de stingere. Nu este necesar un capac suplimentar. Toate intreruptoarele cu protectie universala (Digitrip 520M) sunt prevazute cu display. Fiecare intreruptor automat este dotat din fabrica cu un declansator electronic integrat, cu capac de protectie sigilabil. Daca se comanda un dispozitiv de actionare cu motor, acesta este livrat automat cu un contact auxiliar arc armat.

Aplicatii Exista patru utilizari de baza, in functie de tipul consumatorului protejat. Intreruptoarele automate se impart pe patru domenii principale de utilizare: Protectia instalatiei Protectia motorului Protectia transformatorului Protectia generatorului Aceste utilizari de baza impun conditii diferite, indeplinite de diversele declansatoare electronice. Intreruptoare cu electromagnet de inchidere Sunt destinate in special pentru aplicatii cu sincronizare. Intreruptoare de cupla Alaturi de intreruptoarele automate IZMX16 sunt disponibile intreruptoarele-separatoare INX16 care sunt utilizate, de exemplu, drept cuple intre partile unei retele. Modularitate Echiparea ulterioara cu accesorii este posibila intr-un mod foarte comod prin montajul din fata. In acest mod puteti reactiona intodeauna in mod flexibil la modificarea cerintelor din instalatia dumneavoastra.

Prezentare generala Intreruptoare automate in aer IZMX16, Intreruptoare-separatoare INX16


IZMX16, INX16
Alte beneficii ale intreruptorului automat IZMX16 Designul racordurilor principale ofera flexibilitate maxima. Racordurile orizontale pot fi simplu rotite in instalatie astfel incat pot fi utilizate ca racorduri verticale. Caseta intreruptorului automat IZMX16 are integrata o flansa racord de care pot fi prinse sistemul de bare, conectate astfel direct fara utilizarea adaptorilor. Din acest motiv, adaptorii de racord principal pentru IZMX16 nu sunt continuti in livrarea standard. Nu uitati sa comandati suplimentar adaptorii de racord daca acestia sunt solicitati. Un contor de manevre poate fi acum utilizat datorita pozitiei separate de montaj, independent de dispozitivul de actionare cu motor. Manevrarea variantei debrosabile: Intreruptorul este dotat cu o manivela de mana, continuta in livrarea standard. Aceasta este acum posibila si cu o scula standard (levier patrat de 1/4 "). Sursa externa 24-V Functiile de protectie standard ale intreruptorului automat IZMX16 sunt independente de sursa de tensiune externa. Alimenatarea unitatilor electronice, de exemplu pentru protectia la suprasarcina si scurt-circuit, este implementata printr-un transformator de curent integrat in intreruptorul automat. Declansatorul cu protectie universala cu display poate fi alimentat optional la o sursa de 24 V c.c. daca functiile display-ului vor fi utilizate fara incarcare. Sursa externa de 24V c.c. este necesara daca functiile de comunicatie sunt solicitate. Capacitate de comunicatie Siguranta mare pentru personalul de intretinere cu ARMSTM Daca IZMX16 este dotat cu noul sistem ARMS (Arcflash Reduction Maintenance System), in cazul unui defect de tip arc este deconectat instantaneu. Acesta deconectare este chiar mai rapida decat la declansatorul de scurtcircuit instantaneu. Aceste functii pot fi activate direct pe intreruptorul automat sau printr-un intreruptor extern atunci cand personalul de intretinere intra in zona periculaosa. Alte componente ale sistemului de protectie ARCON in legatura cu IZMX16 pot oferi protectie in caz de erori de arc in etape. ARCON pe Internet: www.moeller.net/arcon Criterii de alegere a intreruptoarelor automate IZMX16 Criteriile de baza pentru alegerea intreruptoarelor automate sunt: Curent maxim la scurtcircuit n poziia de montaj a ntreruptorului automat Ik max: Aceast valoare determin capacitatea de rupere la scurtcircuit, respectiv capacitatea de a suporta curentul de scurt durat al ntreruptorului automat prin comparare cu valorile Icu, Ics si Icw ale comutatorului i determin efectivgabaritul acestuia a Date tehnice. Curentul nominal In care trebuie s circule prin ramificaia respectiv: Aceast valoare nu trebuie s depeasc intensitatea maxim a curentului nominal al ntreruptorului automat. Curentul nominal este strict legat in cazul IZM de modulul pentru curentul nominal. Temperatura ambiant a ntreruptorului automat: De regul, aceasta este temperatura interioar a tabloului. n cazul temperaturii ambientale crescute, consultai tabelele cu informatii a Date tehnice Construcie: montaj fix sau debroat, tripolar sau tetrapolar. Curentul minim de scurtcircuit, care circul prin aparatul de comutare: Declanatorul trebuie s recunoasc aceast valoare tot drept scurtcircuit i s reacioneze cu o declanare Funciile de protecie ale ntreruptorului automat: Acestea sunt stabilite prinalegerea declanatorului respectiv pentru supracurent. Documentaie Manual de utilizare AWB1230-1628de AWB1230-1628en Program caracteristici CurveSelect Setarile specifice, caracteristicile de declansare si evaluarea competenta a interactiunii lor le gasiti la: www.moeller.net/de/support

Intreruptoarele automate IZMX16, prin capacitatea acestora de comunicatie deschid noi posibilitati in distributia energiei. Un nou aparat tip P cu display color este in pregatire. Acestea furnizeaza toate informatiile importante pentru functionare si le transmit mai departe. Astfel, creste transparenta instalatiei, iar intervalele de reactie la conditii speciale , de exemplu supracurent, nesimetria fazelor si supratensiune, se scurteaza. Printr-o interventie rapida in cadrul procesului, pot fi indicate de exemplu defectiuni ale instalatiei sau pot fi planificate lucrari de intretinere. O interfata Moldbus este oferita ca alternativa a interfetei Profibus.

Coduri de comanda Intreruptoare automate in aer,compacte,tripolare


IZMX16
Capacitate de rupere Icu/Ics kA Curent nominal In = Iu A Fixe Tip Cod comanda Debrosabile Tip Cod comanda Casetele trebuie comandate separat.

Domeniu de reglare Declansator la Declansator la scurtcircuit suprasarcina temporizat instantaneu Ir Isd = Ir x Ii = In x A

I
Intreruptoare automate pentru protectie selectiva Piesele de racord nu sunt incluse, se comanda separat. 42/42 630 315 630 2 - 10 800 1000 1250 1600 50/50 630 800 1000 1250 1600 65/50 630 800 1000 1250 1600 400 800 500 1000 625 1250 800 1600 315 630 400 800 500 1000 625 1250 800 1600 315 630 400 800 500 1000 625 1250 800 1600

2 - 12, OFF

IZMX16B3-V06F 123346 IZMX16B3-V08F 123347 IZMX16B3-V10F 123348 IZMX16B3-V12F 123349 IZMX16B3-V16F 123350 IZMX16N3-V06F 123371 IZMX16N3-V08F 123372 IZMX16N3-V10F 123373 IZMX16N3-V12F 123374 IZMX16N3-V16F 123375 IZMX16H3-V06F 123396 IZMX16H3-V08F 123397 IZMX16H3-V10F 123398 IZMX16H3-V12F 123399 IZMX16H3-V16F 123405

IZMX16B3-V06W 122851 IZMX16B3-V08W 122918 IZMX16B3-V10W 122920 IZMX16B3-V12W 122922 IZMX16B3-V16W 122924 IZMX16N3-V06W 123097 IZMX16N3-V08W 123099 IZMX16N3-V10W 123101 IZMX16N3-V12W 123103 IZMX16N3-V16W 123106 IZMX16H3-V06W 123146 IZMX16H3-V08W 123147 IZMX16H3-V10W 123148 IZMX16H3-V12W 123149 IZMX16H3-V16W 123150

Intreruptoare automate pentru protectie universala Piesele de racord nu sunt incluse, se comanda separat. 42/42 630 315 630 2 - 10 800 1000 1250 1600 50/50 630 800 1000 1250 1600 65/50 630 800 1000 1250 1600 400 800 500 1000 625 1250 800 1600 315 630 400 800 500 1000 625 1250 800 1600 315 630 400 800 500 1000 625 1250 800 1600 2 - 12, OFF IZMX16B3-U06F 123351 IZMX16B3-U08F 123352 IZMX16B3-U10F 123353 IZMX16B3-U12F 123354 IZMX16B3-U16F 123355 IZMX16N3-U06F 123376 IZMX16N3-U08F 123377 IZMX16N3-U10F 123378 IZMX16N3-U12F 123379 IZMX16N3-U16F 123380 IZMX16H3-U06F 123411 IZMX16H3-U08F 123417 IZMX16H3-U10F 123423 IZMX16H3-U12F 123429 IZMX16H3-U16F 123435 IZMX16B3-U06W 122940 IZMX16B3-U08W 122941 IZMX16B3-U10W 122979 IZMX16B3-U12W 122984 IZMX16B3-U16W 123020 IZMX16N3-U06W 123109 IZMX16N3-U08W 123111 IZMX16N3-U10W 123114 IZMX16N3-U12W 123129 IZMX16N3-U16W 123130 IZMX16H3-U06W 123151 IZMX16H3-U08W 123152 IZMX16H3-U10W 123153 IZMX16H3-U12W 123154 IZMX16H3-U16W 123155

Coduri de comanda Intreruptoare automate in aer, compacte, tetrapolare


IZMX16
Capacitate de rupere Icu/Ics kA Curent nominal In = Iu A Fixe Tip Cod comanda Debrosabile Tip Cod comanda Casetele trebuie comandate separat.

Domeniu de reglare Declansator la Declansator la scurtcircuit suprasarcina temporizat instantaneu Ir Isd = Ir x Ii = In x A

I
Intreruptoare automate pentru protectie selectiva Piesele de racord nu sunt incluse, se comanda separat. 42/42 630 315 630 2 - 10 800 1000 1250 1600 50/50 630 800 1000 1250 1600 65/50 630 800 1000 1250 1600 400 800 500 1000 625 1250 800 1600 315 630 400 800 500 1000 625 1250 800 1600 315 630 400 800 500 1000 625 1250 800 1600

2 - 12, OFF

IZMX16B4-V06F 123471 IZMX16B4-V08F 123472 IZMX16B4-V10F 123473 IZMX16B4-V12F 123474 IZMX16B4-V16F 123475 IZMX16N4-V06F 123496 IZMX16N4-V08F 123497 IZMX16N4-V10F 123498 IZMX16N4-V12F 123499 IZMX16N4-V16F 123500 IZMX16H4-V06F 123531 IZMX16H4-V08F 123537 IZMX16H4-V10F 123543 IZMX16H4-V12F 123549 IZMX16H4-V16F 123555

IZMX16B4-V06W 123221 IZMX16B4-V08W 123222 IZMX16B4-V10W 123223 IZMX16B4-V12W 123224 IZMX16B4-V16W 123225 IZMX16N4-V06W 123246 IZMX16N4-V08W 123247 IZMX16N4-V10W 123248 IZMX16N4-V12W 123249 IZMX16N4-V16W 123250 IZMX16H4-V06W 123271 IZMX16H4-V08W 123272 IZMX16H4-V10W 123273 IZMX16H4-V12W 123274 IZMX16H4-V16W 123275

Intreruptoare automate pentru protectie universala Piesele de racord nu sunt incluse, se comanda separat. 42/42 630 315 630 2 - 10 800 1000 1250 1600 50/50 630 800 1000 1250 1600 65/50 630 800 1000 1250 1600 400 800 500 1000 625 1250 800 1600 315 630 400 800 500 1000 625 1250 800 1600 315 630 400 800 500 1000 625 1250 800 1600 2 - 12, OFF IZMX16B4-U06F 123476 IZMX16B4-U08F 123477 IZMX16B4-U10F 123478 IZMX16B4-U12F 123479 IZMX16B4-U16F 123480 IZMX16N4-U06F 123501 IZMX16N4-U08F 123502 IZMX16N4-U10F 123503 IZMX16N4-U12F 123504 IZMX16N4-U16F 123505 IZMX16H4-U06F 123561 IZMX16H4-U08F 123567 IZMX16H4-U10F 123573 IZMX16H4-U12F 123579 IZMX16H4-U16F 123580 IZMX16B4-U06W 123226 IZMX16B4-U08W 123227 IZMX16B4-U10W 123228 IZMX16B4-U12W 123229 IZMX16B4-U16W 123230 IZMX16N4-U06W 123251 IZMX16N4-U08W 123252 IZMX16N4-U10W 123253 IZMX16N4-U12W 123254 IZMX16N4-U16W 123255 IZMX16H4-U06W 123276 IZMX16H4-U08W 123277 IZMX16H4-U10W 123278 IZMX16H4-U12W 123279 IZMX16H4-U16W 123285

10

Coduri de comanda Accesorii pentru IZMX16


IZMX-CAS..., IZMX-SH..., IZMX-M16...
Curent nominal In A Variante debrosabile Caseta Echipare standard: capac peste camerele de stingere, kit interblocare cu aparatul de baza F 1600 F 65 3 IZMX163-...W INX163-...W F 1600 F 65 3 IZMX163-...W INX163-...W F 1600 F 1600 F 1600 F 1600 F 65 F 65 F 65 F 65 3 4 4 4 IZMX163-...W INX163-...W IZMX164-...W INX164-...W IZMX164-...W INX164-...W IZMX164-...W INX164-...W Capacitate nominala de deschidere la scurt-circuit Icu kA Poli Utilizabil pentru Tip Cod comanda Tip suplimentar +IZM... Cod comanda cand se comanda cu aparatul de baza Indicatii

IZMX-CAS163-1600 101537 +IZMX-CAS163-1600 101536 IZMX-CAS163-1600-SEC 123986 IZMX-CAS164-1600 101539 +IZMX-CAS164-1600 101538 IZMX-CAS164-1600-SEC 124175

Neechipat cu cleme pentru circuitele auxiliare Echipat numai cu cleme pentru circuitele auxiliare comandate Echipare completa cu cleme pentru circuitul auxiliare Neechipat cu cleme pentru circuitele auxiliar Echipat numai cu clemele pentru circuitele auxiliare comandate. Echipare completa cu cleme pentru circuitele auxiliare.

Jaluzele (protectie contra atingerii) Acopera automat caile principale de forta ale casetei atunci cand intreruptorul automat nu este in pozitia conectat. 800 - 1600 3 (+)IZMX-CAS163 800 - 1600 800 - 1600 800 - 1600 3 4 4 (+)IZMX-CAS163 (+)IZMX-CAS164 (+)IZMX-CAS164

IZMX-SH163 101542 +IZMX-SH163 101541 IZMX-SH164 101544 +IZMX-SH164 101543

Tensiune nominala alimentare circuit de comanda Us V

Utilizabil pentru

Tip Cod comanda Tip suplimentar +IZM... Cod comanda cand se comanda cu aparatul de baza

Indicatii

Dispozitiv de armare cu motor Motorul tensioneaza automat arcul pentru comanda inchidere de la distanta sau locala. Un contact semnalizare de tip "Resort armat" inclus in livrare. 24 c.c. IZMX16 INX16 24 c.c. IZMX16 INX16 48 c.c. IZMX16 INX16 48 c.c. IZMX16 INX16 110 - 125 c.c. IZMX16 INX16 110 - 125 c.c. IZMX16 INX16 220 - 250 c.c. IZMX16 INX16 220 - 250 c.c. IZMX16 INX16 110 - 127 c.a. IZMX16 INX16 110 - 127 c.a. IZMX16 INX16 220 - 240 c.a. IZMX16 INX16 220 - 240 c.a. IZMX16 INX16

IZMX-M16-24DC 123594 +IZMX-M16-24DC 123593 IZMX-M16-48DC 123596 +IZMX-M16-48DC 123595 IZMX-M16-110DC 123598 +IZMX-M16-110DC 123597 IZMX-M16-220DC 123600 +IZMX-M16-220DC 123599 IZMX-M16-110AC 123602 +IZMX-M16-110AC 123601 IZMX-M16-230AC 123604 +IZMX-M16-230AC 123603

La echiparea ulterioara sunt necesare doua cleme de comanda a pag 16

Coduri de comanda Accesorii pentru IZMX16


IZMX-OC16, IZMX-ST..., +IZMX-STS..., IZMX-SR...
Tensiune nominala alimentare circuit de comanda Us V Utilizabil pentru Tip Cod comanda Tip suplimentar +IZM... Cod comanda cand se comanda cu aparatul de baza Indicatii

11

Contor de manevre Contorizeaza numarul de actionari ON/OFF. Montaj si in absenta dispozitivului de armare cu motor. IZMX16 INX16 IZMX16 INX16 Declansatoare voltmetrice Un electromagnet de inchidere se poate combina cu un declansator de deschidere si un declansator de minima tensiune sau cu doua declansatoare de deschidere. Declansator de deschidere 24 c.c. IZMX16 INX16 24 c.c. 48 c.c. 48 c.c. 110 - 125 c.c. 110 - 127 c.a. 110 - 125 c.c. 110 - 127 c.a. 220 - 250 c.c. 208 - 240 c.a. 220 - 250 c.c. 208 - 240 c.a. Declansator de deschidere nr.2 Nu se poate combina cu un declansator de tensiune minima. 24 c.c. 48 c.c. 110 - 125 c.c. 110 - 127 c.a. 220 - 250 c.c. 208 - 240 c.a. Electromagnet de inchidere Fara contact de semnalizare pregatit de inchidere. 24 c.c. 24 c.c. 48 c.c. 48 c.c. 110 - 125 c.c. 110 - 127 c.a. 110 - 125 c.c. 110 - 127 c.a. 220 - 250 c.c. 208 - 240 c.a. 220 - 250 c.c. 208 - 240 c.a.

IZMX-OC16 123606 +IZMX-OC16 123605

IZMX-ST24DC 123608 +IZMX-ST24DC 123607 IZMX-ST48DC 123656 +IZMX-ST48DC 123616 IZMX-ST110AD 123728 +IZMX-ST110AD 123696 IZMX-ST230AD 123730 +IZMX-ST230AD 123729

La echipare ulterioara este necesara o clema de comanda suplimentara a pag 16

IZMX16 INX16

+IZMX-STS24DC 123731 +IZMX-STS48DC 123732 +IZMX-STS110AD 123733 +IZMX-STS230AD 123734

La echipare ulterioara este necesara o clema de comanda suplimentara a pag 16

IZMX16 INX16

IZMX-SR24DC 123736 +IZMX-SR24DC 123735 IZMX-SR48DC 123738 +IZMX-SR48DC 123737 IZMX-SR110AD 123740 +IZMX-SR110AD 123739 IZMX-SR230AD 123742 +IZMX-SR230AD 123741

La echipare ulterioara este necesara o clema de comanda suplimentara a pag 16

12

Coduri de comanda Accesorii pentru IZMX16


IZMX-UVR..., IZMX-AS22
Tensiune nominala alimentare circuit de comanda Us V Utilizabil pentru Tip Cod comanda Tip suplimentar +IZM... Cod comanda cand se comanda cu aparatul de baza Indicatii

Declansatoare voltmetrice Declansator de tensiune minima Nu se poate combina cu un al doilea declansator de deschidere. 24 c.c. 24 c.c. 32 c.c. 32 c.c. 48 c.c. 48 c.c. 110 - 125 c.c. 110 - 127 c.a. 110 - 125 c.c. 110 - 127 c.a. 220 - 250 c.c. 208 - 240 c.a. 220 - 250 c.c. 208 - 240 c.a. 380 - 415 c.a. 380 - 415 c.a. 480 c.a. 480 c.a. 600 c.a. 600 c.a. Contacte auxiliare Contacte auxiliare standard pentru semnalizare ON/OFF. 2 ND si 2 NI sunt incluse in echiparea aparatului de baza. 2 ND si 2 NI pot fi comandate suplimentar

IZMX16 INX16

IZMX-UVR24DC 123744 +IZMX-UVR24DC 123743 IZMX-UVR32DC 123746 +IZMX-UVR32DC 123745 IZMX-UVR48DC 123748 +IZMX-UVR48DC 123747 IZMX-UVR110AD 123801 +IZMX-UVR110AD 123761 IZMX-UVR220AD 123873 +IZMX-UVR220AD 123841 IZMX-UVR400AC 123875 +IZMX-UVR400AC 123874 IZMX-UVR480AC 123877 +IZMX-UVR480AC 123876 IZMX-UVR600AC 123879 +IZMX-UVR600AC 123878

La echipare ulterioara este necesara o clema de comanda suplimentara a pag 16

IZMX16 INX16

IZMX-AS22 123881 +IZMX-AS22 123880

La echipare ulterioara sunt necesare trei cleme de comanda suplimentare a pag 16

Coduri de comanda Accesorii pentru IZMX16


IZMX-OTS, IZMX-RR..., IZMX-RA, IZMX-PLPC16, IZMX-KL...
Tensiune nominala alimentare circuit de comanda Us V Semnalizare declansare si optiuni Reset Contacte semnalizare declansare Semnalizare declansare cu doua contacte comutatoare. Resetare de la distanta Resetare electrica de la distanta a contactului de semnalizare de declansare si a pinului rosu (Semnalizare de declansare mecanica). Nu se combina cu resetarea automata. 24 c.c. IZMX16 24 c.c. 110 - 127 c.a./c.c. 110 - 127 c.a./c.c. 208 - 250 c.a./c.c. 208 - 250 c.a./c.c. Resetare automata Intreruptorul automat este pregatit de inchidere imediat dupa declansare. Intreruptorul nu este dotat cu pinul rosu indicator. Nu se combina cu resetarea la distanta. IZMX16 Accesorii pentru blocare Capac blocabil cu lacat pentru butoane Capacul blocabil limiteaza acesul la butoanele ON si OFF. Blocare cu cheie in OFF (deconectat). Blocarea cu cheie "SAFE-OFF" securizeaza intreruptorul in pozitia OFF. Interblocajul functioneaza impreuna cu comanda locala sau de la distanta. IZMX16 INX16 Utilizabil pentru Tip Cod comanda Tip suplimentar +IZM... Cod comanda cand se comanda cu aparatul de baza Indicatii

13

IZMX16

IZMX-OTS 123889 +IZMX-OTS 123888

La echipare ulterioara sunt necesare trei cleme de comanda suplimentare a pag 16

IZMX-RR24DC 123891 +IZMX-RR24DC 123890 IZMX-RR110AD 123893 +IZMX-RR110AD 123892 IZMX-RR230AD 123896 +IZMX-RR230AD 123895

IZMX-RA 123898 +IZMX-RA 123897

IZMX16 INX16

IZMX-PLPC16 123946 +IZMX-PLPC16 123906

IZMX-KLP-SO16-CASTELL 124184 +IZMX-KLP-SO16-CASTELL 124187 IZMX-KLP-SO16-RONIS 124186 +IZMX-KLP-SO16-RONIS 124185 IZMX-KLP-SO16-KIRK 126481 +IZMX-KLP-SO16-KIRK 126480 IZMX-KLP-SO16-CES 126479 +IZMX-KLP-SO16-CES 126478

Set piese Castell pentru interblocare fara cilindru de inchidere. Set piese Castell pentru interblocare fara cilindru de inchidere. Set piese Ronis pentru interblocare fara cilindru de inchidere. Set piese Ronis pentru interblocare fara cilindru de inchidere. Set de piese Kirk pentru interblocare fara cilindru de inchidere. Set de piese Kirk pentru interblocare fara cilindru de inchidere. Set de piese CES pentru interblocare fara cilindru de inchidere. Set de piese CES pentru interblocare fara cilindru de inchidere.

14

Coduri de comanda Accesorii pentru IZMX16


IZMX-DTV..., IZMX-DTU..., IZMX-TEST, IZMX-DTUP...
Tensiune nominala alimentare circuit de comanda Us V Utilizabil pentru Tip Cod comanda Tip suplimentar +IZM... Cod comanda cand se comanda cu aparatul de baza Indicatii

Optiuni si accesorii pentru declansatoarele electronice Functii suplimentare pentru declansatorul selectiv tip V (echipate cu Digitrip 520LSI) Protectie impotriva defectelor cu IZMX16-V pamantul (Digitrip 520LSI) IZMX16-V Selectivitatea zonala (scade intarzierea (Digitrip 520LSI) la declansare in circuitele cu coordonarea temporizarii). Functii suplimentare pentru declansatorul tip U (echipat cu Digitrip 520M) Declansatoarele tip U sunt echipate standard cu: Afisaj Capabilitate de comunicatie Alarma la suprasarcina" Highloadalarm" In locul alarmei de suprasarcina (HLA) se poate alege functia de protectie la defecte cu pamantul (EP) sau alarma (EA) impotriva defectelor cu pamantul.Pentru comunicatia in retea trebuie sa va alegeti suplimentar un modul de comunicatie. 24 c.c. IZMX16-U Protectie impotriva defectelor cu (Digitrip 520M) pamantul. Aceasta inlocuieste alarma la suprasarcina. 24 c.c. IZMX16-U Alarma impotriva defectelor cu (Digitrip 520M) pamantul. Aceasta inlocuieste alarma la suprasarcina. 24 c.c. IZMX16-U Functia ARMS (Digitrip 520M) Functia ARMS (Arcflash Reduction TM) mareste Maintenance System siguranta personalului, printr-o metoda simpla si sigura de a reduce timpii de declansare la defecte. 24 c.c. IZMX16-U Selectivitate zonala (Digitrip 520M) Selectivitatea zonala scade intarzierea la declansare in circuitele cu coordonarea temporizarii. Dispozitiv de testare declansatoare digitale IZMX16 Kit testare functionala (100 - 240 V c.a.) Module de comunicatie Modul de comunicatie IZMX16 MODBUS Modul de comunicatie IZMX16 PROFIBUS

+IZMX-DTV-EP 124016 +IZMX-DTV-ZSI 124017

+IZMX-DTU-EP 124018 +IZMX-DTU-EA 124019 +IZMX-DTU-ARMS 124020

+IZMX-DTU-ZSI 124021

IZMX-TEST 124169 IZMX-DTUP-MOD 124023 IZMX-DTUP-DP 124024

La echipare ulterioara sunt necesare patru cleme de comanda suplimentare. a pag16

Coduri de comanda Accesorii pentru IZMX16


IZMX-RP16..., IZMX-CT16-N
Curent nominal In A Utilizabil pentru Tip Cod comanda Tip suplimentar +IZM... Cod comanda cand se comanda cu aparatul de baza Indicatii

15

Optiuni si accesorii pentru declansatoarele electronice Fise de curent nominal (Rating Plugs) Prin inlocuirea acestei fise se reduce curentul nominal al intreruptorului nominal al intreruptorului asigurand astfel o adaptare la schimbarea conditiilor aplicatiei. Valoarea nominala a fisei poate fi doar mai mica sau aceeasi cu a curentilor nominali ai aparatului de baza. Fisa poate fi inlocuita fara a fi necesara schimbarea senzorului de curent. 200 Iu F 800 A 200 250 250 300 300 400 400 400 500 500 500 630 630 630 800 800 800 800 1000 1000 1000 1250 1250 1250 1600 Senzor de curent pentru conductorul de nul Senzor de curent extern pentru detectia curentului pe nul. Protectia la defectele cu pamantul pentru intreruptoarele automate tripolare in sisteme cu patru conductoare. Iu F 800 A Iu F 800 A Iu F 800 A Iu F 800 A Iu F 800 A Iu F 800 A 1000 A F Iu F 1250 A Iu F 1250 A Iu F 800 A 1000 A F Iu F 1250 A Iu F 1250 A Iu F 800 A 1000 A F Iu F 1250 A 800 A F Iu F 1250 A Iu F 800 A 1000 A F Iu F 1250 A Iu = 1600 A 1000 A F Iu F 1600 A 1000 A F Iu F 1250 A Iu = 1600 A 1250 A F Iu F 1600 A Iu F 1250 A Iu = 1600 A Iu = 1600 A Iu = 1600 A

IZMX-RP16A-200 124027 +IZMX-RP16-200 124026 IZMX-RP16A-250 124029 +IZMX-RP16-250 124028 IZMX-RP16A-300 124031 +IZMX-RP16-300 124030 IZMX-RP16A-400 124033 IZMX-RP16B-400 124034 +IZMX-RP16-400 124032 IZMX-RP16A-500 124036 IZMX-RP16B-500 124037 +IZMX-RP16-500 124035 IZMX-RP16A-630 124039 IZMX-RP16B-630 124040 +IZMX-RP16-630 124038 IZMX-RP16A-800 124042 IZMX-RP16B-800 124043 IZMX-RP16C-800 124051 +IZMX-RP16-800 124041 IZMX-RP16B-1000 124131 IZMX-RP16C-1000 124156 +IZMX-RP16-1000 124091 IZMX-RP16B-1250 124158 IZMX-RP16C-1250 124159 +IZMX-RP16-1250 124157 IZMX-RP16C-1600 124160 IZMX-CT16-N 124188

IZMX16

La echipare ulterioara este necesara o clema de comanda suplimentara a pag 16

16

Coduri de comanda Accesorii pentru IZMX16


IZMX-THV..., IZMX-SEC16-TB..., IZMX-DEG16, IZMX-DC16
Curent nominal In A Set racorduri principale In continutul livrarii aparatului de baza si a casetei nu sunt incluse racordurile principale. Acest adaptor universal poate fi montat pentru racordare orizontala sau verticala. Un set contine racordurile pentru partea de sus si de jos. Racord universal spate pentru 800 - 1600 montaj fix 800 - 1600 Racord universal spate pentru montaj debrosabil 800 - 1600 800 - 1600 Alte accesorii Cleme de racord circuite de comanda pentru montaj fix Cleme de racord, 8 blocuri Cleme de racord, 20 blocuri Cleme de racord, 30 blocuri Cleme de racord circuite de comanda pentru montaj debrosabil Cleme de racord, 8 blocuri Cleme de racord, 20 blocuri Cleme de racord, 30 blocuri Nr.poli Utilizabil pentru Tip Cod comanda

3 4 3 4

IZMX163-...F INX163-...F IZMX164-...F INX164-...F IZMX163-...W INX163-...W IZMX164-...W INX164-...W

IZMX-THV163H-F 124180 IZMX-THV164H-F 124182 IZMX-THV163H-W 124176 IZMX-THV164H-W 124178

IZMX16F INX16F IZMX16F INX16F IZMX16F INX16F IZMX16W INX16W IZMX16W INX16W IZMX16W INX16W

IZMX-SEC16-TB8-F 124166 IZMX-SEC16-TB20-F 124167 IZMX-SEC16-TB30-F 124168 IZMX-SEC16-TB8-W 124162 IZMX-SEC16-TB20-W 124163 IZMX-SEC16-TB30-W 124165

Capac de protectie Capacul de protectie asigura un grad de protectie mai mare. Rama pentru decupare usa Acopera decuparea (pentru dezvoltari ulterioare) Kit interblocare cu caseta Aceasta este o piesa de schimb. Asigura interblocare intre aparatul de baza si caseta. Manivela pentru brosare Aceasta este o piesa de schimb. Manivela este continuta in livrarea intreruptorului automat debrosabil. IZMX16W INX16W IZMX-LT16 124174 IZMX16W INX16W IZMX-CRB16 124173 IZMX16 INX16 IZMX-BC16 124172 IZMX16 INX16 IZMX-DC16 124171

Indrumari de proiectare Dispunerea contactelor


IZMX16

17

Intern
Declansator de deschidere Declansator de minima tensiune Contact semnalizare declansare (OTS) 1

Cleme

2 ST2 4 UV2 6 OT1M 8 OT2B

1 ST1 3 UV1 5 OT1C 7 OT1B 9 OT2C 11 ALMC 13 ALMC 15 N1 17 G1 19 SGF2 21 +24V 23 CMM1 25 CMM3 27 ZOUT 29 ZIN 31 33 ARMS2 35 SR1 37 E01 39 SC 41 LCC 43 C1

Contact semnalizare declansare (OTS) 2


10 OT2M 12 ALM1

Alarma

14

Intrare senzor pentru neutru


Intrare senzor neutru stea transformator

16 N2 18 G2 20 SGF1 22 AGND 24 CMM2 26 CMM4

Declansator electronic Digitrip

Validare semnal senzor neutru trafo Sursa de alimentare 24 V c.c.

Comunicatie

Selectivitate zonala ZSI

28 ZCOM 30 32

(ARMS) Electromagnet de inchidere Dispozitiv de actionare cu motor Semnalizare arc armat Semnalizare "Pregatit de inchidere"
M

34 ARMS1 36 SR2 38 E02 40 LCB 42 LCM 44 A1

46 B2

45 B1 47 C2 49 C3

Contact auxiliar ND, NI

48 A2 50 A3

52 B4 54 A4

51 B3 53 C4

18

Indrumari de proiectare Caracteristici de declansare IZMX16


IZMX16...V..., IZMX16...U...
IZMX16V(U)... Caracteristici de declansare pentru protectia selectiva si universala Protectia la suprasarcina (L) si protectia la scurt-circuit temporizata (S) Vezi indicatiile 1 - 7. Protectie L: caracteristica It si protectie S: caracteristica palier A Reglaj protectie la suprasarcina 10000
9000 8000 2 h 7000 6000 5000 1 h 4000 3000 2000

A 0.5 - 1 x In = Ir (0.5, 0.6, 0.7, 0.75, 0.8, 0.9, 0.95, 1.0)

B C D E F G H I J K L

Timp de declansare total maxim Timp de declansare total minim Domeniu reglare temporizare suprasarcina Reglaj protectie la scurt-circuit de scurta durata Caracteristica palier functie de reglajul temporizarii de scurta durata Sfarsitul caracteristicii determinat de aplicatie Caracteristica It functie de reglajul temporizarii de scurta durata Reglaj protectie la scurt-circuit instantanee Declansator pentru curenti mari de scurt-circuit Reglaj protectie la defecte cu pamantul Domeniu reglaj la caracteristica palier pentru protectia la defecte cu pamantul Caracteristica It pentru protectia la defecte cu pamantul temporizata Reglaj temporizat la defecte cu pamantul la caracteristica It

t [s]

1000 900 800 700 600 500 400 300 200

1 min

100 90 80 70 60 50 40 30 20

M Caracteristica palier pentru protectia la defecte cu pamantul temporizata N O

C
24

Protectie S: caracteristica It
10 9 8 7 6 5 4 3 2

15

10 9 8 7 6 5 4 3 2

Isd = 6 x Ir (2, 4, 7, 10, 12, 15, 20, 24 s + 0/- 30 )

t [s]

c b

1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2

e d b c f h

E
(Ii : 2 - 10 x Ir g 10 ) 0.5 0.4 0.3 0.2

1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2

0.5 0.3 0.1 , 0.3 , 0.5 s 0.1

F
(0.1 - 0.5 s)

0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02

0.1

0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 1230DIA-96 (5722B19) 0.01

0.01

1230DIA-67 (5722B19) 0.5 0.7 0.9 0.6 0.8 1 2 3 4 5 6 7 8 9 10 20 30 40 50 60 80 100


I/Ir

4 5 6 7 8 9 10

20

30 40 50 60 80 100
I/Ir

Indrumari de proiectare Caracteristici de declansare IZMX16


IZMX16...V..., IZMX16...U...
IZMX16V(U)...Caracteristici de declansare pentru protectia selectiva si universala Protectia la scurt-circuit instantanee (I) Vezi indicatiile 2, 6, 8, 9, 10, 11. Protectie I: reglabila Protectie I: pentru instantanee la curenti de scurt-circuit mari
10 9 8 7 6 5 4 3 2 10 9 8 7 6 5 4 3 2

19

t [s]

1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2

t [s]
2 - 12 x In g 10

1 0.9 0.8 0.7 0.6 0.5 0.4 0.3

d c b f

h j l

0.2

0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02

0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02

0.01

1230DIA-97 (5722B20) 0.5 0.7 0.9 0.6 0.8 1 2 3 4 5 6 7 8 9 10 20 30 40 50


In

0.01

1230DIA-98 (5722B20) 10 20 30 40 50 60 80 100 70 90 200 300 400 600 800 1000


kA

IZMX16V(U)... Protectia optionala la defecte cu pamantul +IZMX-DTV(U)-EP Vezi indicatiile 2, 6, 12, 13, 14, 15, 16. G: Protectia la defecte cu pamantul, caracteristica palier G: Protectia la defecte cu pamantul, caracteristica It
20 t [s] 20

10 9 8 7 6 5 4 3 2

t [s]
0.25 0.5 1.0
0.25 - 1.0 x In g 10

10 9 8 7 6 5 4 3 2 0.3 0.4 0.6

1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.35

0.75
0.5 0.4 0.3 0.2 0.1 - 0.5 s

1 0.9 0.8 0.7 0.6 0.5 0.4

0.25 0.5 0.3

0.3 0.2

0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 1230DIA-99 (5722B21) 0.01 0.2 0.05 0.07 0.09 0.06 0.08 0.1

0.1

0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02

0.1

O
0.1 , 0.3 , 0.5 s

0.3 0.4 0.5 0.7 0.9 0.6 0.8 1

5 6 7 89
In

0.01

1230DIA-100 (5722B21) 0.2 0.3 0.4 0.5 0.7 0.9 0.6 0.8 1 2 3 4 5 6 7 8 910
In

20

Indrumari de proiectare Curbe de declansare IZMX16


IZMX16...V..., IZMX16...U...
IZMX16U... Modulul optional de testare +IZMX-DTU-ARMS Vezi indicatii 2, 6, 11, 17, 18, 19, 20. Modul de testare ARMS
1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2
4800 A g 15

t [s]

0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 1230DIA-101 (5722B22) 0.01 0.5 0.7 0.9 0.6 0.8 1 2 3

4 5 6 7 8 910

20

30 40 50
kA

Declansatorul electronic are o memorie termica, care poate determina reducerea timpului de declansare la suprasarcina. Acest efect al memoriei termice apare daca un curent mai mare decat valoarea reglata pentru declansarea la suprasarcina apare pentru o anumita durata si este intrerupt printr-o declansare a unui dispozitiv din aval sau chiar a intreruptorului in cauza. La o suprasarcina ulterioara, intreruptorul va reactiona intr-un timp mai scurt decat normal. Valoarea cu care se reduce temporizarea este inversa fata de valoarea timpului scurs de la suprasarcina precedenta.Trebuie sa treaca aproximativ 5 minute pentru a se reseta complet memoria.

11 Aceste caracteristici sunt valabile pentru toate intreruptoarele automate IZMX16. Timpii total de deschidere indicati sunt maximali si au in vedere timpul maxim de raspuns al declansatorului, intreruptorul automat se deschide si intreruperea curentului are loc in prezenta unor factori care reprezinta cele mai diferite conditii cum ar fi: tensiune maxima nominala, intreruperea unei faze si un factor minim de putere. Timpi mai rapizi de deschidere sunt posibili in functie de conditiile specifice din instalatii si tipul de intreruptor automat.

Punctul final al caracteristicii este determinat de aplicatie si de capacitatea de intrerupere a intreruptorului automat. Activarea declansatoarelor de suprasarcina are loc la 110 % din Ir, cu o toleranta de 10 % (semnalizare prin LED-ul "Unit Status"). Activarea declansatorului de scurtcircuit cu temporizare scurta Isd se realizeaza la 100 % 10 %. Daca avem selectivitate zonala (ZSI) la declansatorul de scurt-circuit cu scurta temporizare si nu exista un semnal blocat, atunci timpul minim (0,10 s), se aplica indiferent de temporizarea tsd setata. Pentru curba It punctul de revenire la caracteristica plata este indicat prin linie punctata si are loc la 8 x Ir .

12 Reglajul protectiei la defectele cu pamantul are ca nivel de declansare valoarea conventionala 100 % 10 % . 13 Tolerantele pe nivelele de curent sunt de 10 % din valoarea aratata pe diagrama, cu exceptia notelor.

14 Declansarea la defecte cu pamantul combinatie cu functia ARMS este limitata la 1200 A.

15 Daca selectivitatea zonala (ZSI) este activata in cazul protectiei la defecte cu pamantul si nu exista un semnal blocat, atunci se aplica o valoare de timp minim (caracteristica palier ), indiferent de setari. 16 Punctul de intoarcere de la caracteristica It la caracteristica plata este indicata cu linie punctata si are loc la 0,625 x In .

Timpul total de deschidere indicat include timpul de raspuns al declansatorului electronic, timpul de deschidere a intreruptorului si timpul de intrerupere a curentului. Caracteristicile sunt aplicabile pentru o temperatura ambianta cuprinsa intre -20 C si +55 C. O temperatura de peste +85 C va declansa automat intreruptorul si va fi semnalizata prin aprinderea LED-ului portocaliu. Intreruptorul trebuie sa corespunda valorilor de decalibrare din tabelul cu date tehnice. Reglajul protectiei la scurtcircuit instantaneu are ca nivel de declansare valoarea conventionala 100 % 10 % . Declansatoarele instantanee la scurt-circuit pot fi dezactivate si de client prin pozitionarea selectorului pe OFF.

17 Functia ARMS trebuie activata printr-un comutator sau prin comunicatii la distanta. Un LED albastru indica ca setarea functiei de testare este activa.

18 Timpii de deschidere sunt indicati in prezenta unei surse de curent auxiliar.

19 Declansarea determinata de functia ARMS este semnalizata de LED-ul INST. 20 Toleranta este 15 %.

10 Toate declansatoarele electronice au o declansare instantanee la scurt-circuit ce devine activa de fiecare data cand sunt reglate in pozitia OFF. Aceasta declansare se va produce la atingerea unui curent de varf de 90 kA si va fi semnalizata printr-un LED rosu INST.

Note

21

22

Date tehnice Intreruptoare automate IZMX16


IZMX16...
IZMX16B06 Date generale Standarde si normative Temperatura ambianta Pozitia de montaj IZMX16B08 IZMX16B10 IZMX16B12 IZMX16B16 IZMX16N06

Date tehnice Intreruptoare automate IZMX16


IZMX16...
IZMX16N08 IZMX16N10 IZMX16N12 IZMX16N16

23

Depozitare In functionare (deschis)

C C

IEC/EN 60947 -40 - +70 (aparat cu afisaj LCD -20 - +70) -25 - +70 (aparat cu afisaj LCD -20 - +70)
30 30

IEC/EN 60947 -40 - +70 (aparat cu afisaj LCD -20 - +70) -25 - +70 (aparat cu afisaj LCD -20 - +70)
30 30

30 30

30 30

Categoria de utilizare Grad de protectie Directie de intrare a curentului in aparat Cai principale de curent Curent nominal = Curent nominal neintrerupt Curent nominal neintrerupt la 50 C1) Curent nominal neintrerupt la 60 C1) Curent nominal neintrerupt la 70 C1) Tensiune nominala de tinere la impuls Tensiune nominala de utilizare Utilizare in retele IT pana la U = 440 V Utilizare in retele IT pana la U = 690 V Categoria de supratensiune/Grad de poluare Tensiune nominala de izolare pana la 440 V 50/60 Hz pana la 690 V 50/60 Hz Curent nominal admisibil de scurta t=1s durata 50/60 Hz t=3s Capacitate nominala de deschidere la scurtcircuit Icn IEC/EN 60947 Ciclu pana la 240 V 50/60 Hz Icu O-t-CO pana la 440 V 50/60 Hz pana la 690 V 50/60 Hz pana la 1100 V 50/60 Hz IEC/EN 60947 Ciclu pana la 240 V 50/60 Hz Ics O-t-CO-t-CO pana la 440 V 50/60 Hz pana la 690 V 50/60 Hz pana la 1100 V 50/60 Hz Timpi de Timp total de deschidere comutare Timp de inchidere Timp de inchidere electrica (prin electromagnet de inchidere) Timp de deschidere electrica (prin declansator de/ deschidere/ de tensiune minima) Timp de deschidere prin declansator electronic (declansator de scurtcircuit fara temporizare) Durata de mecanica, fara intretinere viata mecanica, cu intretinere electrica, fara intretinere electrica, cu intretinere Frecventa maxima de comutare Puterea disipata la curentul nominal In la montaj fix incarcare trifazata simetrica debrosabil Greutate Montaj fix Montaj debrosabil 3-poli 4-poli 3-poli 4-poli
1) Curent

B IP20, IP54 cu capac de protectie oricare In = Iu Iu Iu Iu Uimp Ue IIT IIT Ui Icm Icm Icw Icw Icu Icu Icu Icu Ics Ics Ics Ics A A A A V c.a. V c.a. kA kA V kA kA kA kA kA kA kA kA kA kA kA kA ms ms ms ms ms Manevre Manevre Manevre Manevre Manevre/h W W kg kg kg kg 630 599 567 504 12000 690 21,5 III/3 1000 88,2 88,2 42 42 42 42 42 42 42 20 25 30 25/50 25 12500 20000 10000 10000 60 36 50 15,23 20,14 38,65 47,17 800 760 720 640 12000 690 21,5 III/3 1000 88,2 88,2 42 42 42 42 42 42 42 20 25 30 25/50 25 12500 20000 10000 10000 60 59 80 15,23 20,14 38,65 47,17 1000 950 900 800 12000 690 21,5 III/3 1000 88,2 88,2 42 42 42 42 42 42 42 20 25 30 25/50 25 12500 20000 10000 10000 60 92 125 15,23 20,14 38,65 47,17

B IP20, IP54 cu capac de protectie oricare 1250 1188 1125 1000 12000 690 21,5 III/3 1000 88,2 88,2 42 42 42 42 42 42 42 20 25 30 25/50 25 12500 20000 10000 10000 60 132 180 15,23 20,14 38,65 47,17 1600 1520 1440 1280 12000 690 21,5 III/3 1000 88,2 88,2 42 42 42 42 42 42 42 20 25 30 25/50 25 12500 20000 10000 10000 60 235 320 15,23 20,14 38,65 47,17 630 599 567 504 12000 690 21,5 III/3 1000 105,0 88,2 42 85 50 42 50 50 42 20 25 30 25/50 25 12500 20000 10000 10000 60 36 50 15,23 20,14 38,65 47,17 800 760 720 640 12000 690 21,5 III/3 1000 105,0 88,2 42 85 50 42 50 50 42 20 25 30 25/50 25 12500 20000 10000 10000 60 59 80 15,23 20,14 38,65 47,17 1000 950 900 800 12000 690 21,5 III/3 1000 105,0 88,2 42 85 50 42 50 50 42 20 25 30 25/50 25 12500 20000 10000 10000 60 92 125 15,23 20,14 38,65 47,17 1250 1188 1125 1000 12000 690 21,5 III/3 1000 105,0 88,2 42 85 50 42 50 50 42 20 25 30 25/50 25 12500 20000 10000 10000 60 132 180 15,23 20,14 38,65 47,17 1600 1520 1440 1280 12000 690 21,5 III/3 1000 105,0 88,2 42 85 50 42 50 50 42 20 25 30 25/50 25 12500 20000 10000 10000 60 235 320 15,23 20,14 38,65 47,17

Capacitati de rupere Capacitate nominala de inchidere la scurtcircuit

Indicatie

de durata admisibil pentru intreruptoare automate functionand in tablouri de distributiela diverse valori ale temperaturii ambiante din interior. Estimarea temperaturii din interiorul tabloului se face utilizand metodele de calcul din reglementarile CEI.

24

Date tehnice Intreruptoare automate IZMX16


IZMX16...
IZMX16H06 Date generale Standarde si normative Temperatura ambianta Pozitia de montaj IZMX16H08 IZMX16H10 IZMX16H12 IZMX16H16

Date tehnice Intreruptoare automate IZMX16


IZMX16...

25

Depozitare In functionare (deschis)

C C

IEC/EN 60947 -40 - +70 (aparat cu afisaj LCD -20 - +70) -25 - +70 (aparat cu afisaj LCD -20 - +70)
30 30

IEC/EN 60947 -40 - +70 (aparat cu afisaj LCD -20 - +70) -25 - +70 (aparat cu afisaj LCD -20 - +70)
30 30

30 30

30 30

Categoria de utilizare Grad de protectie Directia de intrare a curentului in aparat Cai principale de curent Curent nominal = Curent nominal neintrerupt Curent nominal neintrerupt la 50 C1) Curent nominal neintrerupt la 60 C1) Curent nominal neintrerupt la 70 C1) Tensiune nominala de tinere la impuls Tensiune nominala de utilizare Utilizare in retele IT pana la U = 440 V Utilizare in retele IT pana la U = 690 V Categoria de supratensiune/Grad de poluare Tensiune nominala de izolare pana la 440 V 50/60 Hz pana la 690 V 50/60 Hz Curent nominal admisibil de scurta t=1s durata 50/60 Hz t=3s Capacitate nominala de deschidere la scurtcircuit Icn IEC/EN 60947 Ciclu pana la 240 V 50/60 Hz Icu O-t-CO pana la 440 V 50/60 Hz pana la 690 V 50/60 Hz pana la 1100 V 50/60 Hz IEC/EN 60947 Ciclu pana la 240 V 50/60 Hz Ics O-t-CO-t-CO pana la 440 V 50/60 Hz pana la 690 V 50/60 Hz pana la 1100 V 50/60 Hz Timpi de Timp total de deschidere comutare Timp de inchidere Timp de inchidere electrica (prin electromagnet de inchidere) Timp de deschidere electrica (prin declansator de/ deschidere/ de tensiune minima) Timp de deschidere prin declansator electronic (declansator de scurtcircuit fara temporizare) Durata de mecanica, fara intretinere viata mecanica, cu intretinere electrica, fara intretinere electrica, cu intretinere Frecventa maxima de comutare Puterea disipata la curentul nominal In la montaj fix incarcare trifazata simetrica debrosabil Greutate Montaj fix Montaj debrosabil 3-poli 4-poli 3-poli 4-poli
1) Curent

B IP20, IP54 cu capac de protectie oricare In = Iu Iu Iu Iu Uimp Ue IIT IIT Ui Icm Icm Icw Icw Icu Icu Icu Icu Ics Ics Ics Ics A A A A V c.a. Vc.a. kA kA V kA kA kA kA kA kA kA kA kA kA kA kA ms ms ms ms ms Manevre Manevre Manevre Manevre Manevre/h W W kg kg kg kg 630 599 567 504 12000 690 21,5 III/3 1000 136,5 88,2 42 85 65 42 65 50 42 20 25 30 25/50 25 12500 20000 10000 10000 60 36 50 15,23 20,14 38,65 47,17 800 760 720 640 12000 690 21,5 III/3 1000 136,5 88,2 42 85 65 42 65 50 42 20 25 30 25/50 25 12500 20000 10000 10000 60 59 80 15,23 20,14 38,65 47,17 1000 950 900 800 12000 690 21,5 III/3 1000 136,5 88,2 42 85 65 42 65 50 42 20 25 30 25/50 25 12500 20000 10000 10000 60 92 125 15,23 20,14 38,65 47,17

B IP20, IP54 cu capac de protectie oricare 1250 1188 1125 1000 12000 690 21,5 III/3 1000 136,5 88,2 42 85 65 42 65 50 42 20 25 30 25/50 25 12500 20000 10000 10000 60 132 180 15,23 20,14 38,65 47,17 1600 1520 1440 1280 12000 690 21,5 III/3 1000 136,5 88,2 42 85 65 42 65 50 42 20 25 30 25/50 25 12500 20000 10000 10000 60 235 320 15,23 20,14 38,65 47,17

Capacitati de rupere Capacitate nominala de inchidere la scurtcircuit

Indicatie

de durata admisibil pentru intreruptoare automate functionand in tablouri de distributiela diverse valori ale temperaturii ambiante din interior. Estimarea temperaturii din interiorul tabloului se face utilizand metodele de calcul din reglementarile CEI.

26

Date tehnice Intreruptoare separatoare INX16


INX16...
INX16B06 Date generale Standarde si normative Temperatura ambianta Pozitia de montaj INX16B08 INX16B10 INX16B12 INX16B16 INX16N06

Date tehnice Intreruptoare separatoare INX16


INX16...
INX16N08 INX16N10 INX16N12 INX16N16

27

Depozitare In functionare (deschis)

C C

IEC/EN 60947 -40 - +70 -25 - +70 (aparat cu afisaj LCD -20 - +70)
30 30

IEC/EN 60947 -40 - +70 -25 - +70 (aparat cu afisaj LCD -20 - +70)
30 30

30 30

30 30

Categoria de utilizare Grad de protectie Directia de intrare a curentului in aparat Cai principale de curent Curent nominal = Curent nominal neintrerupt Curent nominal neintrerupt la 50 C1) Curent nominal neintrerupt la 60 C1) Curent nominal neintrerupt la 70 C1) Tensiune nominala de tinere la impuls Tensiune nominala de utilizare Utilizare in retele IT pana la U = 440 V Utilizare in retele IT pana la U = 690 V Categoria de supratensiune/Grad de poluare Tensiune nominala de izolare pana la 440 V 50/60 Hz pana la 690 V 50/60 Hz Curent nominal admisibil de scurta t=1s durata 50/60 Hz t=3s Timpi de Timp total de deschidere comutare Timp de inchidere Timp de inchidere electrica (prin electromagnet de inchidere) Timp de deschidere electrica (prin declansator de/ deschidere/ de tensiune minima) Durata de mecanica, fara intretinere viata mecanica, cu intretinere electrica, fara intretinere electrica, cu intretinere Frecventa maxima de comutare Puterea disipata la curentul nominal In la montaj fix incarcare trifazata simetrica debrosabil Greutate Montaj fix Montaj debrosabil 3-poli 4-poli 3-poli 4-poli
1) Curent

B IP20, IP54 cu capac de protectie oricare In = Iu Iu Iu Iu Uimp Ue IIT IIT Ui Icm Icm Icw Icw A A A A V c.a. V c.a. kA kA V kA kA kA kA ms ms ms ms Manevre Manevre Manevre Manevre Manevre/h W W kg kg kg kg 630 599 567 504 12000 690 21,5 III/3 1000 88,2 88,2 42 20 25 30 25/50 12500 20000 10000 10000 60 36 50 15,23 20,14 38,65 47,17 800 760 720 640 12000 690 21,5 III/3 1000 88,2 88,2 42 20 25 30 25/50 12500 20000 10000 10000 60 59 80 15,23 20,14 38,65 47,17 1000 950 900 800 12000 690 21,5 III/3 1000 88,2 88,2 42 20 25 30 25/50 12500 20000 10000 10000 60 92 125 15,23 20,14 38,65 47,17

B IP20, IP54 cu capac de protectie oricare 1250 1188 1125 1000 12000 690 21,5 III/3 1000 88,2 88,2 42 20 25 30 25/50 12500 20000 10000 10000 60 132 180 15,23 20,14 38,65 47,17 1600 1520 1440 1280 12000 690 21,5 III/3 1000 88,2 88,2 42 20 25 30 25/50 12500 20000 10000 10000 60 235 320 15,23 20,14 38,65 47,17 630 599 567 504 12000 690 21,5 III/3 1000 88,2 88,2 42 20 25 30 25/50 12500 20000 10000 10000 60 36 50 15,23 20,14 38,65 47,17 800 760 720 640 12000 690 21,5 III/3 1000 88,2 88,2 42 20 25 30 25/50 12500 20000 10000 10000 60 59 80 15,23 20,14 38,65 47,17 1000 950 900 800 12000 690 21,5 III/3 1000 88,2 88,2 42 20 25 30 25/50 12500 20000 10000 10000 60 92 125 15,23 20,14 38,65 47,17 1250 1188 1125 1000 12000 690 21,5 III/3 1000 88,2 88,2 42 20 25 30 25/50 12500 20000 10000 10000 60 132 180 15,23 20,14 38,65 47,17 1600 1520 1440 1280 12000 690 21,5 III/3 1000 88,2 88,2 42 20 25 30 25/50 12500 20000 10000 10000 60 235 320 15,23 20,14 38,65 47,17

Capacitati de rupere Capacitate nominala de inchidere la scurtcircuit

Indicatie

de durata admisibil pentru intreruptoare automate functionand in tablouri de distributiela diverse valori ale temperaturii ambiante din interior. Estimarea temperaturii din interiorul tabloului se face utilizand metodele de calcul din reglementarile CEI.

28

Date tehnice Intreruptoare separatoare INX16


INX16...
INX16H06 Date generale Standarde si normative Temperatura ambianta Pozitia de montaj INX16H08 INX16H10 INX16H12 INX16H16

Date tehnice Intreruptoare separatoare INX16


INX16...

29

Depozitare In functionare (deschis)

C C

IEC/EN 60947 -40 - +70 -25 - +70 (aparat cu afisaj LCD -20 - +70)
30 30

IEC/EN 60947 -40 - +70 -25 - +70 (aparat cu afisaj LCD -20 - +70)
30 30

30 30

30 30

Categoria de utilizare Grad de protectie Directia de intrare a curentului in aparat Cai principale de curent Curent nominal = Curent nominal neintrerupt Curent nominal neintrerupt la 50 C1) Curent nominal neintrerupt la 60 C1) Curent nominal neintrerupt la 70 C1) Tensiune nominala de tinere la impuls Tensiune nominala de utilizare Utilizare in retele IT pana la U = 440 V Utilizare in retele IT pana la U = 690 V Categoria de supratensiune/Grad de poluare Tensiune nominala de izolare pana la 440 V 50/60 Hz pana la 690 V 50/60 Hz Curent nominal admisibil de scurta t=1s durata 50/60 Hz t=3s Timpi de Timp total de deschidere comutare Timp de inchidere Timp de inchidere electrica (prin electromagnet de inchidere) Timp de deschidere electrica (prin declansator de/ deschidere/ de tensiune minima) Durata de mecanica, fara intretinere viata mecanica, cu intretinere electrica, fara intretinere electrica, cu intretinere Frecventa maxima de comutare Puterea disipata la curentul nominal In la montaj fix incarcare trifazata simetrica debrosabil Greutate Montaj fix Montaj debrosabil 3-poli 4-poli 3-poli 4-poli
1) Curent

B IP20, IP54 cu capac de protectie oricare In = Iu Iu Iu Iu Uimp Ue IIT IIT Ui Icm Icm Icw Icw A A A A V AC V AC kA kA V kA kA kA kA ms ms ms ms Manevre Manevre Manevre Manevre Manevre/h W W kg kg kg kg 630 599 567 504 12000 690 21,5 III/3 1000 88,2 88,2 42 20 25 30 25/50 12500 20000 10000 10000 60 36 50 15,23 20,14 38,65 47,17 800 760 720 640 12000 690 21,5 III/3 1000 88,2 88,2 42 20 25 30 25/50 12500 20000 10000 10000 60 59 80 15,23 20,14 38,65 47,17 1000 950 900 800 12000 690 21,5 III/3 1000 88,2 88,2 42 20 25 30 25/50 12500 20000 10000 10000 60 92 125 15,23 20,14 38,65 47,17

B IP20, IP54 cu capac de protectie oricare 1250 1188 1125 1000 12000 690 21,5 III/3 1000 88,2 88,2 42 20 25 30 25/50 12500 20000 10000 10000 60 132 180 15,23 20,14 38,65 47,17 1600 1520 1440 1280 12000 690 21,5 III/3 1000 88,2 88,2 42 20 25 30 25/50 12500 20000 10000 10000 60 235 320 15,23 20,14 38,65 47,17

Capacitati de rupere Capacitate nominala de inchidere la scurtcircuit

Indicatie

de durata admisibil pentru intreruptoare automate functionand in tablouri de distributiela diverse valori ale temperaturii ambiante din interior. Estimarea temperaturii din interiorul tabloului se face utilizand metodele de calcul din reglementarile CEI.

30

Date tehnice Accesorii IZMX16


IZMX-AS22, IZMX-OTS, IZMX-S..., IZMX-U...
Contacte auxiliare si contacte semnalizare declansare IZMX-AS22 IZMX-OTS Capacitate nominala de rupere Sarcina inductiva 250 V c.a. 125 V c.c. 250 V c.c.

A A A

10 0,5 0,25

10 0,5 0,25

Declansatoare de deschidere IZMXIZMXST24DC ST48DC IZMXIZMXSTS24DC STS48DC Tensiune nominala de alimentare circuit de comanda c.a. 50/60 Hz Us V c.c. Us V Putere consumata c.a. c.c. Timp de reactie a intreruptorului automat la Us VA W ms

IZMXST110AD IZMXSTS110AD

IZMXST230AD IZMXSTS230AD

Electromagneti de inchidere IZMXIZMXSR24DC SR48DC

IZMXSR110AD

IZMXSR230AD

24 5 (atragere 500) 25

48 5 (atragere 530) 25

110 - 127 110 - 125 (atragere 450) (atragere 450) 35

208 - 240 220 - 250 (atragere 450) (atragere 450) 35

24 (atragere 500) 25

48 (atragere 530) 25

110 - 127 110 - 125 (atragere 540) (atragere 540) 25

208 - 240 220 - 250 (atragere 500) (atragere 515) 25

Domeniu de functionare Tensiune de dezexcitare x Uc Tensiune de atragere x Uc

Conform standard IEC

Declansatoare de minima tensiune IZMXIZMXIZMXUVR24DC UVR32DC UVR48DC Tensiune nominala de alimentare circuit de comanda c.a. 50/60 Hz Us V c.c. Us V Putere consumata c.a. c.c. Timp de reactie a intreruptorului automat la Us VA W ms

IZMXUVR110AD

IZMXUVR220AD

IZMXUVR400AC

IZMXUVR480AC

IZMXUVR600AC

24 5 (atragere 500) 50

32 5 (atragere 620) 50

48 5 (atragere 850) 50

110 - 127 110 - 125 5 (atragere 890) 5 (atragere 890) 50

208 - 240 220 - 250 5 (atragere 910) 5 (atragere 910) 50

380 - 415 5 (atragere 960) 5 (atragere 910) 50

480 8 (atragere 800) 5 (atragere 910) 50

600 12 (atragere 800) 5 (atragere 910) 50

Domeniu de functionare Tensiune de dezexcitare x Uc Tensiune de atragere x Uc

Conform standard IEC

Conform standard IEC

Date tehnice/Dimensiuni Accesorii pentru aparate de baza IZMX16


IZMX-M16..., IZMX16
Dispozitiv de actionare cu motor IZMXIZMXM16-24DC M16-48DC Tensiune nominala alimentare circuit de comanda c.a. 50/60 Hz Us V c.c. Us V Timpul necesar armarii resortului la 1 x Us Curent nominal Curent de pornire Putere consumata c.a. 50/60 Hz c.c. In s

31

IZMXM16-110AC

IZMXM16-110DC

IZMXM16-230AC

IZMXM16-220DC

24 3

48 3

110 - 127 3

110 - 125 3

220 - 240 4

220 - 250 4

A A VA W

5 5 150

3 5 150

2 3 280 150

1 5 280 150

1 10 280 150

1 10 280 280

INX16, IZMX16 Varianta fixa INX16F, IZMX16F


210 (3p), 279 (4p)

338

12 13

101

8 32

240 (3p), 309 (4p) 275 (3p), 345 (4p)

184

INX16, IZMX16 Varianta debrosabila INX16W, IZMX16W


267 254 (3p), 324 (4p) 229 (3p), 299 (4p) 22 250 243 17

26

250

210 (3p), 279 (4p)

360

247

109

109

296

L Lasttrennschalter IN

32

Caracteristici tehnice Intreruptoare automate IZM26


IZM26
Icu = Ics la Ue = 440/690 (1100) V c.a. Icu: Capacitate nominala de rupere limita la scurt-circuit la tensiunea nominala de utilizare Ue Ics: Capacitatea nominala de rupere de serviciu la scurt-circuit, la tensiunea nominala de utilizare Ue Capacitate de rupere de baza (B) Capacitate de rupere normala (N) Capacitate de rupere ridicata (H) (S)

440/690 V c.a. Intreruptor automat IZM20 800 1600 IZM20 2000 IZM32 800 1600 IZM32 2000 3200 IZM40 4000 IZM63 4000 6300 IZM32S 3200 65/65 65/65 50/50 50/50 Curent nominal In A Icu = Ics kA

440/690 V c.a. Icu = Ics kA 65/65

440/690 V c.a. Icu = Ics kA

1100 V c.a. Icu = Ics kA

65/65

85/85

100/85

85/85

100/85

85/65

100/65

85/85

100/100

25

Icw t = 1 s/t = 3 s Icw : Curent nominal admisibil de scurta durata

Capacitate de rupere de baza (B) t = 1 s/t = 3 s

Capacitate de rupere normala (N) t = 1 s/t = 3 s Icw kA 65/40

Capacitate de rupere ridicata (H) t = 1 s/t = 3 s Icw kA

Intreruptor automat IZM20

Curent nominal In A 800 1600

Icw kA 50/

IZM20 2000 IZM32 800 1600 IZM32 2000 3200 IZM40 4000 IZM63 4000 6300 85/65 100/65 85/65 100/65 65/50 85/65 85/65 65/ 85/65 85/65 50/30 65/40

Caracteristici tehnice Intreruptor separator IN26


Icm la Ue = 440/690 V c.a. Icm: Capacitate nominala de inchidere la scurt-circuit la tensiunea nominala de utilizare Ue Capacitate de rupere de baza (B) Capacitate de rupere normala (N) Capacitate de rupere ridicata (H)

33

(S)

440/690 V c.a. Intreruptor separator IN20 800 1600 IN20 2000 IN32 800 1600 IN32 2000 3200 IN40 4000 IN63 4000 6300 IN32S 3200 143 143 105 105 Curent nominal In A Icm kA

440/690 V c.a. Icm kA 143

440/690 V c.a. Icm kA

1100 V c.a. Icu = Ics kA

143

187

187

187

220

187

220

52,5

Icw t = 1 s/t = 3 s Icw: Curent nominal admisibil de scurta durata

Capacitate de rupere de baza (B) t = 1 s/t = 3 s

Capacitate de rupere normala (N) t = 1 s/t = 3 s Icw kA 65/40

Capacitate de rupere ridicata (H) t = 1 s/t = 3 s Icw kA

Intreruptor separator IN20

Curent nominal In A 800 1600

Icw kA 50/

IN20 2000 IN32 800 1600 IN32 2000 3200 IN40 4000 IN63 4000 6300 85/65 100/65 85/65 100/65 65/50 85/65 65/ 85/65 50/30 65/40

34

Caracteristici tehnice Declansatoare electronice pentru intreruptoare automate IZM26


IZM26...
IZM26 ...-A... Protectie instalatii DTA Digitrip 520 LI IZM26 ...-V... Protectie selectiva DTV Digitrip 520 LSI(G) IZM26 ...-U... Protectie universala DTU Digitrip 520MC LSI(G) IZM26 ...-P... Protectie universala si masura DTP Digitrip 1150i LSI(G)

Domeniu curent Masurare valoare efectiva (RMS) Functii protectie Generale Optiuni Fisa curent nominal (In) Declansare supratemperatura Protectie suprasarcina Declansare suprasarcina Temporizare tr la 6 x Ir Temporizare I4t Memorie termica Alarma suprasarcina Protectie scurtcircuit temporizata Domeniu protectie scurtcircuit temporizata Temporizare tsd la 8 x Ir , caracteristica I2t Temporizare, caracteristica palier Selectivitate zonala ZSI1) Protectie la scurtcircuit instantanee Domeniu protectie la scurtcircuit instantanee Deconectabila Declansare la inchidere (MCR) Optiuni protectie la defect cu pamantul Alarma la defect cu pamantul Declansare la defect cu pamantul Temporizare tg la 0,625 xIn, caracteristica I2t Temporizare, caracteristica palier Selectivitate zonala la defecte cu pamantul ZSI1) Memorie termica la defecte cu pamantul Protectie neutru Indicatii

200 A 3200 A K

200 A 6300 A K

200 A 6300 A K

200 A 6300 A K

LI K K L 0,4 - 1,0 x (In) 2 - 24 s K S I 200 - 1000 % x ( In) K G N K

LSI, LSIG K K 0,4 - 1,0 x (In) 2 - 24 s K 200 - 1000 % x (Ir) si M13) 100 - 500 ms 100 - 500 ms k 200 - 1000 % x (In) si M13) K K 25 - 100% x (In) 100 - 500 ms 100 - 500 ms k K doar pentru LSI

LSI, LSIG, LSIA K K 0,4 - 1,0 x (In) 2 - 24 s K k1) 200 - 1000 % x (Ir) si M13) 100 - 500 ms 100 - 500 ms k 200 - 1000 % x (In) si M13) K K k1) 25 - 100% x (In)4) 100 - 500 ms 100 - 500 ms k K doar pentru LSI

LSI, LSIG, LSIA K K 0,4 - 1,0 x (In) 2 - 24 s 1-5s K k1) : 0,5 - 1,0 x (Ir) 200 - 1000 % x (Ir) si M13) 100 - 500 ms 100 - 500 ms k 200 - 1000 % x (In) si M13) K K k1) 25 - 100% x (In)4) 100 - 500 ms 100 - 500 ms k K doar pentru LSI K Standard k Optional

ln = Rating Plug (fisa curent nominal) =Transformator curent nominal; lr = Selector reglaj valori declansare suprasarcina 1) Este necesara o sursa de alimentare externa de 24 V c.c. a circuitelor de comanda 2) Tester de mana pentru simulare curent secundar 3) Sunt posibile urmatoarele valori pentru pozitia M1: IZM20
M1 = 14 x In pentru fisa curent nominal de la 200 A pana la 1250 A M1 = 12 x In pentru fisa curent nominal de la 1600 A M1 = 10 x In pentru fisa curent nominal de la 2000 A

IZM32, IZM40

M1 = 14 x In pentru fisa curent nominal de la 200 A pana la 1250 A M1 = 12 x In pentru fisa curent nominal de la 1600 A pana la 2500 A M1 = 10 x In pentru fisa curent nominal de la3200 A pana la 4000 A

IZM63

M1 = 14 x In pentru fisa curent nominal de la 2000 A pana la 2500 A M1 = 12 x In pentru fisa curent nominal de la 3200 A pana la 5000 A M1 = 10 x In pentru fisa curent nominal de la 6300 A

4)

In combinatii cu functia ARMS este limitat la 1200 A

Caracteristici functionale Declansatoare electronice pentru intreruptoare automate IZM26


IZM26...
IZM26 ...-A... Protectie instalatii DTA Digitrip 520 LI IZM26 ...-V... Protectie selectiva DTV Digitrip 520 LSI(G) IZM26 ...-U... Protectie universala DTU Digitrip 520MC LSI(G) IZM26 ...-P... Protectie universala si masura DTP Digitrip 1150i LSI(G)

35

Diagnoza Afisare cauze declansare cu LED Curentul in momentul declansarii Contacte semnalizare la distanta Contacte alarmare programabile Supraveghere Afisaj digital Afisare curent (%) Tensiune faza (%) Putere si Energie (%) Putere aparenta, sens kVA Putere reactiva kVAR Factor putere Factor de creasta Calitate a puterii, armonicii Factor armonic THD (%) Comunicare pe magistrala Functii suplimentare Istoria declansarii (3 valori) Numarator electronic de manevre Testare 2) ARMS (Arcflash Reduction Mentenance System) Afisare forme de unda Indicatii

K Aparat manual

K Aparat manual

K K1) K1) 4 caractere LED K Modbus, Profibus Aparat manual k1)

K K1) K1) K1) 24 caractere LED K K K K K K K K K Modbus, Profibus K K Aparat manual si functii integrate k1) K K Standard k Optional

ln = Rating Plug (fisa curent nominal) = Transformator curent nominal; lr = Selector reglaj valori declansare suprasarcina 1) Este necesara o sursa de alimentare externa de 24 V c.c. a circuitelor de comanda 2) Tester de mana pentru simulare curent secundar 3) Sunt posibile urmatoarele valori pentru pozitia M1: IZM20
M1 = 14 x In pentru fisa curent nominal de la 200 A pana la 1250 A M1 = 12 x In pentru fisa curent nominal de la 1600 A M1 = 10 x In pentru fisa curent nominal de la 2000 A

IZM32, IZM40

M1 = 14 x In pentru fisa curent nominal de la 200 A pana la 1250 A M1 = 12 x In pentru fisa curent nominal de la 1600 A pana la 2500 A M1 = 10 x In pentru fisa curent nominal de la 3200 A pana la 4000 A

IZM63

M1 = 14 x In pentru fisa curent nominal de la 2000 A pana la 2500 A M1 = 12 x In pentru fisa curent nominal de la 3200 A pana la 5000 A M1 = 10 x In pentru fisa curent nominal de la 6300 A

4)

In combinatii cu functia ARMS este limitat la 1200 A.

36

Componentele sistemului Intreruptoare automate IZM26


IZM26
3 3 3 3

4 2

16

15

14
9

13

0 1695

10

11 12

11

11

11

Componentele sistemului Intreruptor automat IZM26


IZM26
Intreruptor automat IZM a pag 40 PROFIBUS si MODBUSModule de comunicatie a pag 63 Racorduri principale Racord vertical pentru 3 si 4 poli Racord orizontal pentru 3 si 4 poli a pag 69 1 Contact "pregatit de conectare" a pag 59 Contact auxiliar Contact ON/OFF, 2 comutatoare a pag 59 Butoane blocabile ON/OFF a pag 60 Contor de manevre a pag 56 Declansator electronic Nu pot fi comandate separat. Digitrip 520 LI Digitrip 520 LSI, Digitrip 520i LSIG Digitrip 520MC LSI, Digitrip 520MCi LSIG Digitrip 1150i LSI, Digitrip 1150 LSIG 7 Rama de etansare a pag 70 Actionare cu motor Armare electrica a arcurilor a pag 56 Fise curent nominal si senzori a pag 64 Contact semnalizare declansare Contact semnalizare declansare (OTS), 2 comutatoare a pag 59 Declansator deschidere a pag 57 Electromagnet de inchidere a pag 57 Declansator de minima tensiune a pag 58 12

37

13

14

10

Caseta pentru unitati debrosabile 4 Casete 2000 A pana la 6300 A a pag 54 Conector circuite de comanda la alegere 2 sau 15 blocuri a pag 70 Contacte de pozitie pentru varianta debrosabila a pag 56 5

15

11

16

16

16

Cod IZM IN 20 32 40 63 B N H S 3 4 A V U P 08 10 12 16 20 25 32 40 50 63 IZM, IN = Familia de produse Gabarite 20: Ingust 800 - 2000 A 32: Standard 800 - 3200 A 40: Dublu ingust 4000 A 63: Dublu standard 4000 - 6300 A Capacitate de rupere B = Baza N = Normala H = Ridicata S = Tip special pentru 1100 V (doar pentru gabarit 32, 3200 A) 3-poli 4-poli Caracteristici declansare A = Protectie instalatii = Digitrip 520 LI V = Protectie selectiva = Digitrip 520 LSI(G) U = Protectie universala = Digitrip 520MC LSI(G) P = Protectie universala si masura = Digitrip 1150i+ LSI(G) Curenti nominali 08: 800 A 10: 1000 A 12: 1250 A 16: 1600 A 20: 2000 A 25: 2500 A 32: 3200 A 40: 4000 A 50: 5000 A 63: 6300 A Constructie W = Debrosabil F = Fix W F

38

Prezentare generala Intreruptoare automate in aer IZM26, Intreruptoare-separatoare IN26


IZM26, IN26

IZM26: Siguranta ridicata Intreruptoarele automate de la Moeller IZM26 sunt oferite intr-o gama completa de intreruptoare automate in aer pana la 6.300 A disponibila in patru gabarite pentru o alegere optima a intreruptorului. Odata cu cresterea curentului nominal, creste numai latimea intreruptorului, acesta permitand alegerea variantei optime. La ora actuala, in lume sunt peste 100.000 de intreruptoarele compacte ce functioneaza in medii industriale severe. Rezistenta mare a materialului ca si a curentilor la scurt-circuit sunt principalele lor caracteristici. Aplicatii Exista patru utilizari de baza. In functie de tipul consumatorului protejat, intreruptoarele automate se impart pe patru domenii principale de utilizare: Protectia instalatiei Protectia motorului Protectia transformatorului Protectia generatorului Aceste utilizari de baza impun conditii diferite, indeplinite de diversele declansatoare electronice. Intreruptoare cu electromagnet de inchidere Sunt destinate in special pentru sarcini sincronizate. Intreruptoare de cupla Alaturi de intreruptoarele automate IZM26, sunt disponibile intreruptoarele-separatoare IN26 care sunt utilizate, de exemplu, drept cuple intre partile unei retele. Modularitate Echiparea ulterioara cu accesorii este posibila intr-un mod foarte comod, prin montaj din fata. Prin aceasta puteti reactiona intodeauna in mod flexibil la modificarea cerintelor din instalatia dumneavoastra.

Echipare standard IZM26 este echipat standard cu un declansator electronic. si adaptori de racord orizontal. Montarea standard este pe o placa de montaj orizontala sau pe o traversa orizontala intr-un tablou. La intreruptoarele tetrapolare, conductorul de nul este pe partea stanga (vedere frontala) Conductorul de nul poate fi incarcat 100 % precum conductorii de faza. Intreruptoarele automate sunt prevazute cu un mecanism de blocare mecanica la inchidere. Dupa o declansare la suprasarcina, uzual in primul rand se analizeaza defectul. Dupa ce defectul este identificat si indepartat, mecanismul de blocare mecanica la inchidere este resetat prin apasarea indicatorului de declansare de culoare rosie aflat in partea din fata a intreruptorului. Optional poate fi comandata functia "Resetare automata". Aceasta permite intreruptorului sa fie pus in functiune imediat de fiecare data cand mecanismul cu arc este retensionat. In aceste aplicatii analiza obligatorie a defectelor este intentionat evitata. Numarul de blocuri de borne auxiliare depinde de accesoriile instalate Daca o caseta este comandata fara intreruptor, aceasta poate fi deja echipata cu un numar maxim de blocuri de borne auxiliare. Standard sunt 2 contacte ND 2 contacte NI pentru semnalizarea pozitiei ON/OFF. Un mecanism de codare intre intreruptor si caseta previne combinatiile nepermise ("Rejection Interlock"). Echipare standard extinsa pentru IZM26 Anumite articole care in trecut, erau comandate, acum sunt continute in livrarea standard: Rama de etansare este acum intodeauna inclusa in livrare . La variantele debrosabile aceasta este livrata cu caseta. Capacul camerei de stingere arc pentru varianta debrosabila este inclus. Totusi, intreruptorul automat poate fi scos si camera arcului verificata . La variantele fixe, se recomanda lasarea unui spatiu deasupra intreruptorului suficient pentru verificarea camerei de stingere a arcului. Nu este necesar un capac suplimentar. Toate intreruptoarele prevazute cu protectie universala (Digitrip 520M) au montat un display. Fiecare intreruptor automat este dotat din fabrica cu un declansator electronic echipat cu capac de protectie sigilabil. Daca se comanda un dispozitiv de actionare cu motor, acesta este livrat automat cu un contact auxiliar arc armat.

Prezentare generala Intreruptoare automate in aer IZM26, Intreruptoare-separatoare IN26


IZM26, IN26
Alte beneficii ale intreruptorului automat IZM26 Sunt in continuare patru variante principale de declansatoare de supracurent (A, V, U, P). Doar a patra varianta a fost redenumita si este acum "P" (ca la masurarea puterii) in loc de "D" (declansator digital). Pe fiecare intreruptor automat tip P (Digitrip 1150) masurarea puterii este deja parte integrata a declansatorului electronic. Prizele de tensiune pentru functia de masurare a puterii sunt integrate in aparat astfel ca un transformator de tensiune extern suplimentar nu mai este necesar. Aceasta solutie reduce costurile, spatiul cat si efortul instalarii. Anumite aplicatii cer utilizarea unei interfete la sursa de tensiune externa (vezi mai jos). O noua caracteristica este accea ca declansatorul electronic poate fi pregatit pentru o sursa de tensiune externa de 120 V c.a. sau 240 V c.a. (optiune de comanda ). Un contor de manevre poate acum fi utilizat datorita pozitiei separate de montaj, independent de dispozitivul de actionare cu motor. Manevrarea variantei debrosabile: Intreruptorul este dotat cu o manivela, continuta in livrarea standard. Aceasta este acum posibila si cu o scula standard (patrat 3/8 "). Sunt disponibile patru gabarite asigurand astfel alegerea optima pentru orice aplicatie . Totusi, cu doua gabarite se poate acoperi intreaga gama de curenti nominali de la 800 A pana la 6300 A . Gabaritele IZM40 si IZM63 sunt realizate prin dublarea gabaritelor IZM20 si IZM32. Prin acesta rezulta ca la IZM40 si IZM63 exista doua racorduri pentru fiecare faza, pe intrare si pe iesire. Acest lucru faciliteaza designul termic al tabloului si in cateva sisteme de tablouri se simplifica productia prin reducerea numarului de variante pentru adaptorii de bare. Secventa fazelor pentru IZM40 si IZM63 este urmatoarea: (NN)AABBCC. Intreruptorul automat IZM de 6300 A este echipat standard cu racord orizontal, pentru a simplifica considerabil conectarea barelor la cele mai multe sistem de distributie. Sursa externa Functiile de protectie standard ale intreruptorului automat IZM26 sunt independente de sursa de tensiune externa. Sursa de alimentare a unitatilor electronice, de exemplu pentru protectia la suprasarcina si scurt-circuit, este implementata printr transformatoare de curent integrate in intreruptorul automat. Declansatorul cu protectie universala cu display poate fi alimentat optional la o sursa de 24 V c.c./48 V c.c. sau 120 V c.a/ 240 V c.a. daca functiile display-ului vor fi utilizate fara o sarcina. Sursa externa este necesara daca functiile de comunicatie sunt solicitate. De.clansatorul P trebuie intodeauna alimentat de la o sursa externa, deoarece alegerea lui are in vedere tocmai utilizarea acelor optiuni pentru care este nevoie de o sursa de tensiune suplimentara Comunicarea

39

Intreruptoarele automate IZM26, prin capacitatea acestora de comunicatie deschid noi posibilitati in distributia energiei. Acestea furnizeaza informatii importante pentru functionare si le transmit mai departe. Astfel, creste transparenta instalatiei, iar timpii de reactie la conditii speciale , de exemplu supracurent, nesimetria fazelor si supratensiune, se scurteaza. Printr-o interventie rapida in cadrul procesului, pot fi impiedicate, de exemplu, defectiuni ale instalatiei sau pot fi planificate lucrari de intretinere. O interfata Moldbus este oferita ca alternativa a interfetei Profibus. Siguranta mare pentru personalul de intretinere cu ARMSTM Daca IZM26 este echipat cu noul sistem ARMS (Arcflash Reduction Maintenance System), in cazul unui defect tip arc electric intreruptor deconectat instantaneu. Aceasta deconectare este chiar mai rapida decat cu declansatorul de scurtcircuit instantaneu. Aceasta functie poate fi activata direct pe intreruptorul automat sau printr-un comutator extern atunci cand personalul de intretinere intra in zona periculoasa. Alte componente ale sistemului de protectie ARCON, impreuna cu IZM26, pot oferi protectie pe nivele in caz de defecte de tip arc electric. Despre ARCON pe Internet: www.moeller.net/arcon

Criterii de alegere a intreruptoarelor automate IZM26 Criteriile de baza pentru alegerea intreruptoarelor automate sunt: Curent maxim la scurtcircuit n poziia de montaj a ntreruptorului automat Ik max: Aceast valoare determin capacitatea de rupere la scurtcircuit, respectiv capacitatea de a suporta curentul de scurt durat al ntreruptorului automat. Ea se compara cu valorile Icu, Ics si Icw ale intrerupatorului i determin efectiv gabaritul acestuia a Date tehnice. Curentul nominal In care trebuie s circule prin ramificaia respectiv: Aceast valoare nu trebuie s depeasc intensitatea maxim a curentului nominal al ntreruptorului automat. Curentul nominal este strict legat in cazul IZM de fisa pentru curent nominal. Temperatura ambiant a ntreruptorului automat: De regul, aceasta este temperatura interioar a tabloului. n cazul temperaturii ambientale crescute, consultai tabelele cu informatii a Date tehnice Construcie: montaj fix sau debroat, tripolar sau tetrapolar. Curentul minim de scurtcircuit, care circul prin aparatul de comutare: Declanatorul trebuie s recunoasc aceast valoare tot drept scurtcircuit i s reacioneze cu o declanare Funciile de protecie ale ntreruptorului automat: Acestea sunt stabilite prin alegerea declanatorului respectiv pentru supracurent. Documentaie Manual de utilizare AWB1230-1605de AWB1230-1605en Program caracteristici CurveSelect Caracteristicile de declansare in functie de reglaje si evaluarea competenta a interactiunii lor le gasiti la: www.moeller.net/de/support

40

Coduri de comanda Intreruptoare automate in aer, tripolare


IZM26
Capacitate de rupere Curent nominal Gabarit Domeniu de reglare Declansator la scurtcircuit Declansator la suprasartemporizat instantaneu cina Ir Isd = Ir x Ii = In x A Fixe Tip Cod comanda Debrosabile Tip Cod comanda Casetele trebuie comandate separat.

Icu = Ics kA

In = Iu A

I
Intreruptoare automate pentru protectie instalatii

Inclusiv piesele de racord pentru conectare spate si blocul de terminale secundare echipat conform optiunilor comandate pentru intreruptor. 50 800 IZM20 320 800 2 - 10 1000 1250 1600 2000 65 800 1000 1250 1600 2000 800 1000 1250 1600 2000 2500 3200 85 800 1000 1250 1600 2000 2500 3200 100 800 1000 1250 1600 2000 2500 3200 IZM32 400 1000 500 1250 640 1600 800 2000 320 800 400 1000 500 1250 640 1600 800 2000 320 800 400 1000 500 1250 640 1600 800 2000 1000 2500 1280 3200 320 800 400 1000 500 1250 640 1600 800 2000 1000 2500 1280 3200 320 800 400 1000 500 1250 640 1600 800 2000 1000 2500 1280 3200

IZM20B3-A08F 123400 IZM20B3-A10F 123401 IZM20B3-A12F 123402 IZM20B3-A16F 123403 IZM20B3-A20F 123404 IZM20N3-A08F 123430 IZM20N3-A10F 123431 IZM20N3-A12F 123432 IZM20N3-A16F 123433 IZM20N3-A20F 123434 IZM32B3-A08F 123899 IZM32B3-A10F 123900 IZM32B3-A12F 123901 IZM32B3-A16F 123902 IZM32B3-A20F 123903 IZM32B3-A25F 123904 IZM32B3-A32F 123905 IZM32N3-A08F 123939 IZM32N3-A10F 123940 IZM32N3-A12F 123941 IZM32N3-A16F 123942 IZM32N3-A20F 123943 IZM32N3-A25F 123944 IZM32N3-A32F 123945 IZM32H3-A08F 123979 IZM32H3-A10F 123980 IZM32H3-A12F 123981 IZM32H3-A16F 123982 IZM32H3-A20F 123983 IZM32H3-A25F 123984 IZM32H3-A32F 123985

IZM20B3-A08W 123160 IZM20B3-A10W 123161 IZM20B3-A12W 123162 IZM20B3-A16W 123163 IZM20B3-A20W 123164 IZM20N3-A08W 123190 IZM20N3-A10W 123191 IZM20N3-A12W 123192 IZM20N3-A16W 123193 IZM20N3-A20W 123194 IZM32B3-A08W 123609 IZM32B3-A10W 123610 IZM32B3-A12W 123611 IZM32B3-A16W 123612 IZM32B3-A20W 123613 IZM32B3-A25W 123614 IZM32B3-A32W 123615 IZM32N3-A08W 123649 IZM32N3-A10W 123650 IZM32N3-A12W 123651 IZM32N3-A16W 123652 IZM32N3-A20W 123653 IZM32N3-A25W 123654 IZM32N3-A32W 123655 IZM32H3-A08W 123689 IZM32H3-A10W 123690 IZM32H3-A12W 123691 IZM32H3-A16W 123692 IZM32H3-A20W 123693 IZM32H3-A25W 123694 IZM32H3-A32W 123695

Coduri de comanda Intreruptoare automate in aer, tripolare


IZM26
Capacitate de rupere Curent nominal Gabarit Domeniu de reglare Declansator la scurtcircuit Declansator la suprasartemporizat instantaneu cina Ir Isd = Ir x Ii = In x A Fixe Tip Cod comanda Debrosabile Tip Cod comanda Casetele trebuie comandate separat.

41

Icu = Ics kA

In = Iu A

Intreruptoare automate pentru protectie selectiva Inclusiv piesele de racord pentru conectare spate si blocul de terminale secundare echipat conform optiunilor comandate pentru intreruptor. 50 800 IZM20 320 800 2 - 10 2 - 10, OFF 1000 1250 1600 2000 65 800 1000 1250 1600 2000 800 1000 1250 1600 2000 2500 3200 85 800 1000 1250 1600 2000 2500 3200 4000 4000 5000 6300 IZM40 IZM63 IZM32 400 1000 500 1250 640 1600 800 2000 320 800 400 1000 500 1250 640 1600 800 2000 320 800 400 1000 500 1250 640 1600 800 2000 1000 2500 1280 3200 320 800 400 1000 500 1250 640 1600 800 2000 1000 2500 1280 3200 1600 4000 1600 4000 2000 5000 2520 6300

IZM20B3-V08F 123406 IZM20B3-V10F 123407 IZM20B3-V12F 123408 IZM20B3-V16F 123409 IZM20B3-V20F 123410 IZM20N3-V08F 123436 IZM20N3-V10F 123437 IZM20N3-V12F 123438 IZM20N3-V16F 123439 IZM20N3-V20F 123440 IZM32B3-V08F 123907 IZM32B3-V10F 123908 IZM32B3-V12F 123909 IZM32B3-V16F 123910 IZM32B3-V20F 123911 IZM32B3-V25F 123912 IZM32B3-V32F 123913 IZM32N3-V08F 123947 IZM32N3-V10F 123948 IZM32N3-V12F 123949 IZM32N3-V16F 123950 IZM32N3-V20F 123951 IZM32N3-V25F 123952 IZM32N3-V32F 123953 IZM40N3-V40F 124303 IZM63N3-V40F 124304 IZM63N3-V50F 124305 IZM63N3-V63F 124306

IZM20B3-V08W 123166 IZM20B3-V10W 123167 IZM20B3-V12W 123168 IZM20B3-V16W 123169 IZM20B3-V20W 123170 IZM20N3-V08W 123196 IZM20N3-V10W 123197 IZM20N3-V12W 123198 IZM20N3-V16W 123199 IZM20N3-V20W 123200 IZM32B3-V08W 123617 IZM32B3-V10W 123618 IZM32B3-V12W 123619 IZM32B3-V16W 123620 IZM32B3-V20W 123621 IZM32B3-V25W 123622 IZM32B3-V32W 123623 IZM32N3-V08W 123657 IZM32N3-V10W 123658 IZM32N3-V12W 123659 IZM32N3-V16W 123660 IZM32N3-V20W 123661 IZM32N3-V25W 123662 IZM32N3-V32W 123663 IZM40N3-V40W 124193 IZM63N3-V40W 124194 IZM63N3-V50W 124195 IZM63N3-V63W 124196

42

Coduri de comanda Intreruptoare automate in aer, tripolare


IZM26
Capacitate de rupere Curent nominal Gabarit Domeniu de reglare Declansator la scurtcircuit Declansator la suprasartemporizat instantaneu cina Ir Isd = Ir x Ii = In x A Fixe Tip Cod comanda Debrosabile Tip Cod comanda Casetele trebuie comandate separat.

Icu = Ics kA

In = Iu A

Intreruptoare automate pentru protectie selectiva Inclusiv piesele de racord pentru conectare spate si blocul de terminale secundare echipat conform optiunilor comandate pentru intreruptor. 100 800 IZM32 320 800 2 - 10 2 - 10, OFF 1000 1250 1600 2000 2500 3200 4000 4000 5000 6300 IZM40 IZM63 400 1000 500 1250 640 1600 800 2000 1000 2500 1280 3200 1600 4000 1600 4000 2000 5000 2520 6300

IZM32H3-V08F 123987 IZM32H3-V10F 123988 IZM32H3-V12F 123989 IZM32H3-V16F 123990 IZM32H3-V20F 123991 IZM32H3-V25F 123992 IZM32H3-V32F 123993 IZM40H3-V40F 124323 IZM63H3-V40F 124324 IZM63H3-V50F 124325 IZM63H3-V63F 124326

IZM32H3-V08W 123697 IZM32H3-V10W 123698 IZM32H3-V12W 123699 IZM32H3-V16W 123700 IZM32H3-V20W 123701 IZM32H3-V25W 123702 IZM32H3-V32W 123703 IZM40H3-V40W 124213 IZM63H3-V40W 124214 IZM63H3-V50W 124215 IZM63H3-V63W 124216

Intreruptoare automate pentru protectie universala Inclusiv piesele de racord pentru conectare spate si blocul de terminale secundare echipat conform optiunilor comandate pentru intreruptor. 50 800 IZM20 320 800 2 - 10 2 - 10, OFF 1000 1250 1600 2000 65 800 1000 1250 1600 2000 800 1000 1250 1600 2000 2500 3200 IZM32 400 1000 500 1250 640 1600 800 2000 320 800 400 1000 500 1250 640 1600 800 2000 320 800 400 1000 500 1250 640 1600 800 2000 1000 2500 1280 3200

IZM20B3-U08F 123412 IZM20B3-U10F 123413 IZM20B3-U12F 123414 IZM20B3-U16F 123415 IZM20B3-U20F 123416 IZM20N3-U08F 123442 IZM20N3-U10F 123443 IZM20N3-U12F 123444 IZM20N3-U16F 123445 IZM20N3-U20F 123446 IZM32B3-U08F 123915 IZM32B3-U10F 123916 IZM32B3-U12F 123917 IZM32B3-U16F 123918 IZM32B3-U20F 123919 IZM32B3-U25F 123920 IZM32B3-U32F 123921

IZM20B3-U08W 123172 IZM20B3-U10W 123173 IZM20B3-U12W 123174 IZM20B3-U16W 123175 IZM20B3-U20W 123176 IZM20N3-U08W 123202 IZM20N3-U10W 123203 IZM20N3-U12W 123204 IZM20N3-U16W 123205 IZM20N3-U20W 123206 IZM32B3-U08W 123625 IZM32B3-U10W 123626 IZM32B3-U12W 123627 IZM32B3-U16W 123628 IZM32B3-U20W 123629 IZM32B3-U25W 123630 IZM32B3-U32W 123631

Coduri de comanda Intreruptoare automate in aer, tripolare


IZM26
Capacitate de rupere Curent nominal Gabarit Domeniu de reglare Declansator la scurtcircuit Declansator la suprasartemporizat instantaneu cina Ir Isd = Ir x Ii = In x A Fixe Tip Cod comanda Debrosabile Tip Cod comanda Casetele trebuie comandate separat.

43

Icu = Ics kA

In = Iu A

Intreruptoare automate pentru protectie universala Inclusiv piesele de racord pentru conectare spate si blocul de terminale secundare echipat conform optiunilor comandate pentru intreruptor. 85 800 IZM32 320 800 2 - 10 2 - 10, OFF 1000 1250 1600 2000 2500 3200 4000 4000 5000 6300 100 800 1000 1250 1600 2000 2500 3200 4000 4000 5000 6300 IZM40 IZM63 IZM32 IZM40 IZM63 400 1000 500 1250 640 1600 800 2000 1000 2500 1280 3200 1600 4000 1600 4000 2000 5000 2520 6300 320 800 400 1000 500 1250 640 1600 800 2000 1000 2500 1280 3200 1600 4000 1600 4000 2000 5000 2520 6300

IZM32N3-U08F 123955 IZM32N3-U10F 123956 IZM32N3-U12F 123957 IZM32N3-U16F 123958 IZM32N3-U20F 123959 IZM32N3-U25F 123960 IZM32N3-U32F 123961 IZM40N3-U40F 124307 IZM63N3-U40F 124308 IZM63N3-U50F 124309 IZM63N3-U63F 124310 IZM32H3-U08F 123995 IZM32H3-U10F 123996 IZM32H3-U12F 123997 IZM32H3-U16F 123998 IZM32H3-U20F 123999 IZM32H3-U25F 124000 IZM32H3-U32F 124001 IZM40H3-U40F 124327 IZM63H3-U40F 124328 IZM63H3-U50F 124329 IZM63H3-U63F 124330

IZM32N3-U08W 123665 IZM32N3-U10W 123666 IZM32N3-U12W 123667 IZM32N3-U16W 123668 IZM32N3-U20W 123669 IZM32N3-U25W 123670 IZM32N3-U32W 123671 IZM40N3-U40W 124197 IZM63N3-U40W 124198 IZM63N3-U50W 124199 IZM63N3-U63W 124200 IZM32H3-U08W 123705 IZM32H3-U10W 123706 IZM32H3-U12W 123707 IZM32H3-U16W 123708 IZM32H3-U20W 123709 IZM32H3-U25W 123710 IZM32H3-U32W 123711 IZM40H3-U40W 124217 IZM63H3-U40W 124218 IZM63H3-U50W 124219 IZM63H3-U63W 124220

44

Coduri de comanda Intreruptoare automate in aer, tripolare


IZM26
Capacitate de rupere Curent nominal Gabarit Domeniu de reglare Declansator la scurtcircuit Declansator la suprasartemporizat instantaneu cina Ir Isd = Ir x Ii = In x A Fixe Tip Cod comanda Debrosabile Tip Cod comanda Casetele trebuie comandate separat.

Icu = Ics kA

In = Iu A

Intreruptoare automate cu masura Inclusiv piesele de racord pentru conectare spate si blocul de terminale secundare echipat conform optiunilor comandate pentru intreruptor. 50 800 IZM20 320 800 2 - 10 2 - 10, OFF 1000 1250 1600 2000 65 800 1000 1250 1600 2000 800 1000 1250 1600 2000 2500 3200 85 800 1000 1250 1600 2000 2500 3200 4000 4000 5000 6300 IZM40 IZM63 IZM32 400 1000 500 1250 640 1600 800 2000 320 800 400 1000 500 1250 640 1600 800 2000 320 800 400 1000 500 1250 640 1600 800 2000 1000 2500 1280 3200 320 800 400 1000 500 1250 640 1600 800 2000 1000 2500 1280 3200 1600 4000 1600 4000 2000 5000 2520 6300

IZM20B3-P08F 123418 IZM20B3-P10F 123419 IZM20B3-P12F 123420 IZM20B3-P16F 123421 IZM20B3-P20F 123422 IZM20N3-P08F 123448 IZM20N3-P10F 123449 IZM20N3-P12F 123450 IZM20N3-P16F 123451 IZM20N3-P20F 123452 IZM32B3-P08F 123923 IZM32B3-P10F 123924 IZM32B3-P12F 123925 IZM32B3-P16F 123926 IZM32B3-P20F 123927 IZM32B3-P25F 123928 IZM32B3-P32F 123929 IZM32N3-P08F 123963 IZM32N3-P10F 123964 IZM32N3-P12F 123965 IZM32N3-P16F 123966 IZM32N3-P20F 123967 IZM32N3-P25F 123968 IZM32N3-P32F 123969 IZM40N3-P40F 124311 IZM63N3-P40F 124312 IZM63N3-P50F 124313 IZM63N3-P63F 124314

IZM20B3-P08W 123178 IZM20B3-P10W 123179 IZM20B3-P12W 123180 IZM20B3-P16W 123181 IZM20B3-P20W 123182 IZM20N3-P08W 123208 IZM20N3-P10W 123209 IZM20N3-P12W 123210 IZM20N3-P16W 123211 IZM20N3-P20W 123212 IZM32B3-P08W 123633 IZM32B3-P10W 123634 IZM32B3-P12W 123635 IZM32B3-P16W 123636 IZM32B3-P20W 123637 IZM32B3-P25W 123638 IZM32B3-P32W 123639 IZM32N3-P08W 123673 IZM32N3-P10W 123674 IZM32N3-P12W 123675 IZM32N3-P16W 123676 IZM32N3-P20W 123677 IZM32N3-P25W 123678 IZM32N3-P32W 123679 IZM40N3-P40W 124201 IZM63N3-P40W 124202 IZM63N3-P50W 124203 IZM63N3-P63W 124204

Coduri de comanda
Intreruptoare automate in aer, tripolare/Intreruptoare automate in aer 1100 V, tripolare
IZM26
Capacitate de rupere Curent nominal Gabarit Domeniu de reglare Declansator la scurtcircuit Declansator la suprasartemporizat instantaneu cina Ir Isd = Ir x Ii = In x A Fixe Tip Cod comanda Debrosabile Tip Cod comanda Casetele trebuie comandate separat.

45

Icu = Ics kA

In = Iu A

Intreruptoare automate cu masura Inclusiv piesele de racord pentru conectare spate si blocul de terminale secundare echipat conform optiunilor comandate pentru intreruptor. 100 800 IZM32 320 800 2 - 10 2 - 10, OFF 1000 1250 1600 2000 2500 3200 4000 4000 5000 6300 IZM40 IZM63 400 1000 500 1250 640 1600 800 2000 1000 2500 1280 3200 1600 4000 1600 4000 2000 5000 2520 6300

IZM32H3-P08F 124003 IZM32H3-P10F 124004 IZM32H3-P12F 124005 IZM32H3-P16F 124006 IZM32H3-P20F 124007 IZM32H3-P25F 124008 IZM32H3-P32F 124009 IZM40H3-P40F 124331 IZM63H3-P40F 124332 IZM63H3-P50F 124333 IZM63H3-P63F 124334

IZM32H3-P08W 123713 IZM32H3-P10W 123714 IZM32H3-P12W 123715 IZM32H3-P16W 123716 IZM32H3-P20W 123717 IZM32H3-P25W 123718 IZM32H3-P32W 123719 IZM40H3-P40W 124221 IZM63H3-P40W 124222 IZM63H3-P50W 124223 IZM63H3-P63W 124224

Capacitate de rupere Icu = Ics kA

Curent nominal In = Iu A

Domeniu de reglare Declansator la Declansator la scurtcircuit suprasarcina temporizat instantaneu Ir Isd = Ir x Ii = In x A

Fixe Tip Cod comanda

Debrosabile Tip Cod comanda Casetele trebuie comandate separat.

I
IZM26 pentru 1100 V

Inclusiv piesele de racord pentru conectare spate si blocul de terminale secundare echipat conform optiunilor comandate pentru intreruptor. Intreruptoare automate pentru protectie instalatii 25 3200 1280 3200 2 - 10 Intreruptoare automate pentru protectie selectiva 25 3200 1280 3200 2 - 10 Intreruptoare automate pentru protectie universala 25 3200 1280 3200 2 - 10 Intreruptoare automate cu masura 25 3200 1280 3200

IZM32S3-A32F-1100V 123725 IZM32S3-V32F-1100V 123726 IZM32S3-U32F-1100V 123727 IZM32S3-P32F-1100V 123749

IZM32S3-A32W-1100V 123721 IZM32S3-V32W-1100V 123722 IZM32S3-U32W-1100V 123723 IZM32S3-P32W-1100V 123724

2 - 10, OFF

2 - 10, OFF

2 - 10

2 - 10, OFF

46

Coduri de comanda Intreruptoare automate in aer, tetrapolare


IZM26
Capacitate de rupere Curent nominal Gabarit Domeniu de reglare Declansator la scurtcircuit Declansator la temporizat instantaneu suprasarcina Ir Isd = Ir x Ii = In x A Fixe Tip Cod comanda Debrosabile Tip Cod comanda Casetele trebuie comandate separat.

Icu = Ics kA

In = Iu A

I
Intreruptoare automate pentru protectie instalatii

Inclusiv piesele de racord pentru conectare spate si blocul de terminale secundare echipat conform optiunilor comandate pentru intreruptor. 50 800 IZM20 320 800 2 - 10 1000 1250 1600 2000 65 800 1000 1250 1600 2000 800 1000 1250 1600 2000 2500 3200 85 800 1000 1250 1600 2000 2500 3200 100 800 1000 1250 1600 2000 2500 3200 IZM32 400 1000 500 1250 640 1600 800 2000 320 800 400 1000 500 1250 640 1600 800 2000 320 800 400 1000 500 1250 640 1600 800 2000 1000 2500 1280 3200 320 800 400 1000 500 1250 640 1600 800 2000 1000 2500 1280 3200 320 800 400 1000 500 1250 640 1600 800 2000 1000 2500 1280 3200

IZM20B4-A08F 123520 IZM20B4-A10F 123521 IZM20B4-A12F 123522 IZM20B4-A16F 123523 IZM20B4-A20F 123524 IZM20N4-A08F 123550 IZM20N4-A10F 123551 IZM20N4-A12F 123552 IZM20N4-A16F 123553 IZM20N4-A20F 123554 IZM32B4-A08F 124044 IZM32B4-A10F 124045 IZM32B4-A12F 124046 IZM32B4-A16F 124047 IZM32B4-A20F 124048 IZM32B4-A25F 124049 IZM32B4-A32F 124050 IZM32N4-A08F 124084 IZM32N4-A10F 124085 IZM32N4-A12F 124086 IZM32N4-A16F 124087 IZM32N4-A20F 124088 IZM32N4-A25F 124089 IZM32N4-A32F 124090 IZM32H4-A08F 124124 IZM32H4-A10F 124125 IZM32H4-A12F 124126 IZM32H4-A16F 124127 IZM32H4-A20F 124128 IZM32H4-A25F 124129 IZM32H4-A32F 124130

IZM20B4-A08W 123280 IZM20B4-A10W 123281 IZM20B4-A12W 123282 IZM20B4-A16W 123283 IZM20B4-A20W 123284 IZM20N4-A08W 123310 IZM20N4-A10W 123311 IZM20N4-A12W 123312 IZM20N4-A16W 123313 IZM20N4-A20W 123314 IZM32B4-A08W 123754 IZM32B4-A10W 123755 IZM32B4-A12W 123756 IZM32B4-A16W 123757 IZM32B4-A20W 123758 IZM32B4-A25W 123759 IZM32B4-A32W 123760 IZM32N4-A08W 123794 IZM32N4-A10W 123795 IZM32N4-A12W 123796 IZM32N4-A16W 123797 IZM32N4-A20W 123798 IZM32N4-A25W 123799 IZM32N4-A32W 123800 IZM32H4-A08W 123834 IZM32H4-A10W 123835 IZM32H4-A12W 123836 IZM32H4-A16W 123837 IZM32H4-A20W 123838 IZM32H4-A25W 123839 IZM32H4-A32W 123840

Coduri de comanda Intreruptoare automate in aer, tetrapolare


IZM26
Capacitate de rupere Curent nominal Gabarit Domeniu de reglare Declansator la scurtcircuit Declansator la suprasartemporizat instantaneu cina Ir Isd = Ir x Ii = In x A Fixe Tip Cod comanda Debrosabile Tip Cod comanda Casetele trebuie comandate separat.

47

Icu = Ics kA

In = Iu A

I
Intreruptoare automate pentru protectie selectiva

Inclusiv piesele de racord pentru conectare spate si blocul de terminale secundare echipat conform optiunilor comandate pentru intreruptor. 50 800 1000 1250 1600 2000 65 800 1000 1250 1600 2000 800 1000 1250 1600 2000 2500 3200 85 800 1000 1250 1600 2000 2500 3200 4000 4000 5000 6300 IZM40 IZM63 IZM32 IZM20 320 800 400 1000 500 1250 640 1600 800 2000 320 800 400 1000 500 1250 640 1600 800 2000 320 800 400 1000 500 1250 640 1600 800 2000 1000 2500 1280 3200 320 800 400 1000 500 1250 640 1600 800 2000 1000 2500 1280 3200 1600 4000 1600 4000 2000 5000 2520 6300 2 - 10 2 - 10, OFF IZM20B4-V08F 123526 IZM20B4-V10F 123527 IZM20B4-V12F 123528 IZM20B4-V16F 123529 IZM20B4-V20F 123530 IZM20N4-V08F 123556 IZM20N4-V10F 123557 IZM20N4-V12F 123558 IZM20N4-V16F 123559 IZM20N4-V20F 123560 IZM32B4-V08F 124052 IZM32B4-V10F 124053 IZM32B4-V12F 124054 IZM32B4-V16F 124055 IZM32B4-V20F 124056 IZM32B4-V25F 124057 IZM32B4-V32F 124058 IZM32N4-V08F 124092 IZM32N4-V10F 124093 IZM32N4-V12F 124094 IZM32N4-V16F 124095 IZM32N4-V20F 124096 IZM32N4-V25F 124097 IZM32N4-V32F 124098 IZM40N4-V40F 124358 IZM63N4-V40F 124359 IZM63N4-V50F 124360 IZM63N4-V63F 124361 IZM20B4-V08W 123286 IZM20B4-V10W 123287 IZM20B4-V12W 123288 IZM20B4-V16W 123289 IZM20B4-V20W 123290 IZM20N4-V08W 123316 IZM20N4-V10W 123317 IZM20N4-V12W 123318 IZM20N4-V16W 123319 IZM20N4-V20W 123320 IZM32B4-V08W 123762 IZM32B4-V10W 123763 IZM32B4-V12W 123764 IZM32B4-V16W 123765 IZM32B4-V20W 123766 IZM32B4-V25W 123767 IZM32B4-V32W 123768 IZM32N4-V08W 123802 IZM32N4-V10W 123803 IZM32N4-V12W 123804 IZM32N4-V16W 123805 IZM32N4-V20W 123806 IZM32N4-V25W 123807 IZM32N4-V32W 123808 IZM40N4-V40W 124248 IZM63N4-V40W 124249 IZM63N4-V50W 124250 IZM63N4-V63W 124251

48

Coduri de comanda Intreruptoare automate in aer, tetrapolare


IZM26
Capacitate de rupere Curent nominal Gabarit Domeniu de reglare Declansator la scurtcircuit Declansator la suprasartemporizat instantaneu cina Ir Isd = Ir x Ii = In x A Fixe Tip Cod comanda Debrosabile Tip Cod comanda Casetele trebuie comandate separat.

Icu = Ics kA

In = Iu A

I
Intreruptoare automate pentru protectie selectiva

Inclusiv piesele de racord pentru conectare spate si blocul de terminale secundare echipat conform optiunilor comandate pentru intreruptor. 100 800 IZM32 320 800 2 - 10 2 - 10, OFF 1000 1250 1600 2000 2500 3200 4000 4000 5000 6300 IZM40 IZM63 400 1000 500 1250 640 1600 800 2000 1000 2500 1280 3200 1600 4000 1600 4000 2000 5000 2520 6300

IZM32H4-V08F 124132 IZM32H4-V10F 124133 IZM32H4-V12F 124134 IZM32H4-V16F 124135 IZM32H4-V20F 124136 IZM32H4-V25F 124137 IZM32H4-V32F 124138 IZM40H4-V40F 124378 IZM63H4-V40F 124379 IZM63H4-V50F 124380 IZM63H4-V63F 124381

IZM32H4-V08W 123842 IZM32H4-V10W 123843 IZM32H4-V12W 123844 IZM32H4-V16W 123845 IZM32H4-V20W 123846 IZM32H4-V25W 123847 IZM32H4-V32W 123848 IZM40H4-V40W 124268 IZM63H4-V40W 124269 IZM63H4-V50W 124270 IZM63H4-V63W 124271

Intreruptoare automate pentru protectie universala Inclusiv piesele de racord pentru conectare spate si blocul de terminale secundare echipat conform optiunilor comandate pentru intreruptor. 50 800 IZM20 320 800 2 - 10 2 - 10, OFF 1000 1250 1600 2000 65 800 1000 1250 1600 2000 800 1000 1250 1600 2000 2500 3200 IZM32 400 1000 500 1250 640 1600 800 2000 320 800 400 1000 500 1250 640 1600 800 2000 320 800 400 1000 500 1250 640 1600 800 2000 1000 2500 1280 3200

IZM20B4-U08F 123532 IZM20B4-U10F 123533 IZM20B4-U12F 123534 IZM20B4-U16F 123535 IZM20B4-U20F 123536 IZM20N4-U08F 123562 IZM20N4-U10F 123563 IZM20N4-U12F 123564 IZM20N4-U16F 123565 IZM20N4-U20F 123566 IZM32B4-U08F 124060 IZM32B4-U10F 124061 IZM32B4-U12F 124062 IZM32B4-U16F 124063 IZM32B4-U20F 124064 IZM32B4-U25F 124065 IZM32B4-U32F 124066

IZM20B4-U08W 123292 IZM20B4-U10W 123293 IZM20B4-U12W 123294 IZM20B4-U16W 123295 IZM20B4-U20W 123296 IZM20N4-U08W 123322 IZM20N4-U10W 123323 IZM20N4-U12W 123324 IZM20N4-U16W 123325 IZM20N4-U20W 123326 IZM32B4-U08W 123770 IZM32B4-U10W 123771 IZM32B4-U12W 123772 IZM32B4-U16W 123773 IZM32B4-U20W 123774 IZM32B4-U25W 123775 IZM32B4-U32W 123776

Coduri de comanda Intreruptoare automate in aer, tetrapolare


IZM26
Capacitate de rupere Curent nominal Gabarit Domeniu de reglare Declansator la scurtcircuit Declansator la suprasartemporizat instantaneu cina Ir Isd = Ir x Ii = In x A Fixe Tip Cod comanda Debrosabile Tip Cod comanda Casetele trebuie comandate separat.

49

Icu = Ics kA

In = Iu A

I
Intreruptoare automate pentru protectie universala

Inclusiv piesele de racord pentru conectare spate si blocul de terminale secundare echipat conform optiunilor comandate pentru intreruptor. 85 800 IZM32 320 800 2 - 10 2 - 10, OFF 1000 1250 1600 2000 2500 3200 4000 4000 5000 6300 100 800 1000 1250 1600 2000 2500 3200 4000 4000 5000 6300 IZM40 IZM63 IZM32 IZM40 IZM63 400 1000 500 1250 640 1600 800 2000 1000 2500 1280 3200 1600 4000 1600 4000 2000 5000 2520 6300 320 800 400 1000 500 1250 640 1600 800 2000 1000 2500 1280 3200 1600 4000 1600 4000 2000 5000 2520 6300

IZM32N4-U08F 124100 IZM32N4-U10F 124101 IZM32N4-U12F 124102 IZM32N4-U16F 124103 IZM32N4-U20F 124104 IZM32N4-U25F 124105 IZM32N4-U32F 124106 IZM40N4-U40F 124362 IZM63N4-U40F 124363 IZM63N4-U50F 124364 IZM63N4-U63F 124365 IZM32H4-U08F 124140 IZM32H4-U10F 124141 IZM32H4-U12F 124142 IZM32H4-U16F 124143 IZM32H4-U20F 124144 IZM32H4-U25F 124145 IZM32H4-U32F 124146 IZM40H4-U40F 124382 IZM63H4-U40F 124383 IZM63H4-U50F 124384 IZM63H4-U63F 124385

IZM32N4-U08W 123810 IZM32N4-U10W 123811 IZM32N4-U12W 123812 IZM32N4-U16W 123813 IZM32N4-U20W 123814 IZM32N4-U25W 123815 IZM32N4-U32W 123816 IZM40N4-U40W 124252 IZM63N4-U40W 124253 IZM63N4-U50W 124254 IZM63N4-U63W 124255 IZM32H4-U08W 123850 IZM32H4-U10W 123851 IZM32H4-U12W 123852 IZM32H4-U16W 123853 IZM32H4-U20W 123854 IZM32H4-U25W 123855 IZM32H4-U32W 123856 IZM40H4-U40W 124272 IZM63H4-U40W 124273 IZM63H4-U50W 124274 IZM63H4-U63W 124275

50

Coduri de comanda Intreruptoare automate in aer, tetrapolare


IZM26
Capacitate de rupere Curent nominal Gabarit Domeniu de reglare Declansator la scurtcircuit Declansator la suprasartemporizat instantaneu cina Ir Isd = Ir x Ii = In x A Fixe Tip Cod comanda Debrosabile Tip Cod comanda Casetele trebuie comandate separat.

Icu = Ics kA

In = Iu A

I
Intreruptoare automate pentru protectie universala cu masura

Inclusiv piesele de racord pentru conectare spate si blocul de terminale secundare echipat conform optiunilor comandate pentru intreruptor. 50 800 IZM20 320 800 2 - 10 2 - 10, OFF 1000 1250 1600 2000 65 800 1000 1250 1600 2000 800 1000 1250 1600 2000 2500 3200 85 800 1000 1250 1600 2000 2500 3200 4000 4000 5000 6300 IZM40 IZM63 IZM32 400 1000 500 1250 640 1600 800 2000 320 800 400 1000 500 1250 640 1600 800 2000 320 800 400 1000 500 1250 640 1600 800 2000 1000 2500 1280 3200 320 800 400 1000 500 1250 640 1600 800 2000 1000 2500 1280 3200 1600 4000 1600 4000 2000 5000 2520 6300

IZM20B4-P08F 123538 IZM20B4-P10F 123539 IZM20B4-P12F 123540 IZM20B4-P16F 123541 IZM20B4-P20F 123542 IZM20N4-P08F 123568 IZM20N4-P10F 123569 IZM20N4-P12F 123570 IZM20N4-P16F 123571 IZM20N4-P20F 123572 IZM32B4-P08F 124068 IZM32B4-P10F 124069 IZM32B4-P12F 124070 IZM32B4-P16F 124071 IZM32B4-P20F 124072 IZM32B4-P25F 124073 IZM32B4-P32F 124074 IZM32N4-P08F 124108 IZM32N4-P10F 124109 IZM32N4-P12F 124110 IZM32N4-P16F 124111 IZM32N4-P20F 124112 IZM32N4-P25F 124113 IZM32N4-P32F 124114 IZM40N4-P40F 124366 IZM63N4-P40F 124367 IZM63N4-P50F 124368 IZM63N4-P63F 124369

IZM20B4-P08W 123298 IZM20B4-P10W 123299 IZM20B4-P12W 123300 IZM20B4-P16W 123301 IZM20B4-P20W 123302 IZM20N4-P08W 123328 IZM20N4-P10W 123329 IZM20N4-P12W 123330 IZM20N4-P16W 123331 IZM20N4-P20W 123332 IZM32B4-P08W 123778 IZM32B4-P10W 123779 IZM32B4-P12W 123780 IZM32B4-P16W 123781 IZM32B4-P20W 123782 IZM32B4-P25W 123783 IZM32B4-P32W 123784 IZM32N4-P08W 123818 IZM32N4-P10W 123819 IZM32N4-P12W 123820 IZM32N4-P16W 123821 IZM32N4-P20W 123822 IZM32N4-P25W 123823 IZM32N4-P32W 123824 IZM40N4-P40W 124256 IZM63N4-P40W 124257 IZM63N4-P50W 124258 IZM63N4-P63W 124259

Coduri de comanda
Intreruptoare automate in aer, tetrapolare, /Intreruptoare automate in aer, 1100 V, tetrapolare
IZM26
Capacitate de rupere Curent nominal Gabarit Domeniu de reglare Declansator la scurtcircuit Declansator la suprasartemporizat instantaneu cina Ir Isd = Ir x Ii = In x A Fixe Tip Cod comanda Debrosabile Tip Cod comanda Casetele trebuie comandate separat.

51

Icu = Ics kA

In = Iu A

I
Intreruptoare automate pentru protectie universala cu masura

Inclusiv piesele de racord pentru conectare spate si blocul de terminale secundare echipat conform optiunilor comandate pentru intreruptor. 100 800 IZM32 320 800 2 - 10 2 - 10, OFF 1000 1250 1600 2000 2500 3200 4000 4000 5000 6300 IZM40 IZM63 400 1000 500 1250 640 1600 800 2000 1000 2500 1280 3200 1600 4000 1600 4000 2000 5000 2520 6300

IZM32H4-P08F 124148 IZM32H4-P10F 124149 IZM32H4-P12F 124150 IZM32H4-P16F 124151 IZM32H4-P20F 124152 IZM32H4-P25F 124153 IZM32H4-P32F 124154 IZM40H4-P40F 124386 IZM63H4-P40F 124387 IZM63H4-P50F 124388 IZM63H4-P63F 124389

IZM32H4-P08W 123858 IZM32H4-P10W 123859 IZM32H4-P12W 123860 IZM32H4-P16W 123861 IZM32H4-P20W 123862 IZM32H4-P25W 123863 IZM32H4-P32W 123864 IZM40H4-P40W 124276 IZM63H4-P40W 124277 IZM63H4-P50W 124278 IZM63H4-P63W 124279

Capacitate de rupere Icu = Ics kA

Curent nominal In = Iu A

Domeniu de reglare Declansator la Declansator la scurtcircuit suprasarcina temporizat instantaneu Ir Isd = Ir x Ii = In x A

Fixe Tip Cod comanda

Debrosabile Tip Cod comanda Casetele trebuie comandate separat.

I
IZM26 pentru 1100 V

Inclusiv piesele de racord pentru conectare spate si blocul de terminale secundare echipat conform optiunilor comandate pentru intreruptor. Intreruptoare automate pentru protectie instalatii 25 3200 1280 3200 2 - 10 Intreruptoare automate pentru protectie selectiva 25 3200 1280 3200 2 - 10 Intreruptoare automate pentru protectie universala 25 3200 1280 3200 2 - 10 Intreruptoare automate cu masura 25 3200 1280 3200

IZM32S4-A32F-1100V 123866 IZM32S4-V32F-1100V 123867 IZM32S4-U32F-1100V 123868 IZM32S4-P32F-1100V 123869

IZM32S4-A32W-1100V 123750 IZM32S4-V32W-1100V 123751 IZM32S4-U32W-1100V 123752 IZM32S4-P32W-1100V 123753

2 - 10, OFF

2 - 10, OFF

2 - 10

2 - 10, OFF

52

Coduri de comanda Intreruptoare-separatoare in aer, tripolare


IN26
Fixe Tip Cod comanda Debrosabile Tip Cod comanda Casetele trebuie comandate separat.

Capacitate nominala de inchidere la scurtcircuit Icm kA

Curent nominal In = Iu A

Gabarit

Curent nominal admisibil de scurta durata t = 1 s Icw kA

Inclusiv piesele de racord pentru conectare spate si blocul de terminale secundare echipat conform optiunilor comandate pentru intreruptor. 55 800 IN20 50 IN32 IN32 1000 IN20 IN32 IN32 1250 IN20 IN32 IN32 1600 IN20 IN32 IN32 2000 69 800 1000 1250 1600 2000 IN20 IN20 IN20 IN20 IN20 IN20 IN32 IN32 110 2500 2500 3200 3200 138 4000 IN32 IN32 IN32 IN32 IN40 IN63 IN63 210 217 3200 5000 5000 6300 6300 IN32 IN63 IN63 IN63 IN63 65 85 50 65 85 50 65 85 50 65 85 50 65 65 65 65 65 65 85 65 85 65 85 85 85 100 85 100 85 100

IN20B3-08F 123424 IN32B3-08F 123931 IN32N3-08F 123971 IN20B3-10F 123425 IN32B3-10F 123932 IN32N3-10F 123972 IN20B3-12F 123426 IN32B3-12F 123933 IN32N3-12F 123973 IN20B3-16F 123427 IN32B3-16F 123934 IN32N3-16F 123974 IN20B3-20F 123428 IN20N3-08F 123454 IN20N3-10F 123455 IN20N3-12F 123456 IN20N3-16F 123457 IN20N3-20F 123458 IN32B3-20F 123935 IN32N3-20F 123975 IN32B3-25F 123936 IN32N3-25F 123976 IN32B3-32F 123937 IN32N3-32F 123977 IN40N3-40F 124315 IN63N3-40F 124316 IN63H3-40F 124336 IN32S3-32F-1100V 123871 IN63N3-50F 124317 IN63H3-50F 124337 IN63N3-63F 124318 IN63H3-63F 124338

IN20B3-08W 123184 IN32B3-08W 123641 IN32N3-08W 123681 IN20B3-10W 123185 IN32B3-10W 123642 IN32N3-10W 123682 IN20B3-12W 123186 IN32B3-12W 123643 IN32N3-12W 123683 IN20B3-16W 123187 IN32B3-16W 123644 IN32N3-16W 123684 IN20B3-20W 123188 IN20N3-08W 123214 IN20N3-10W 123215 IN20N3-12W 123216 IN20N3-16W 123217 IN20N3-20W 123218 IN32B3-20W 123645 IN32N3-20W 123685 IN32B3-25W 123646 IN32N3-25W 123686 IN32B3-32W 123647 IN32N3-32W 123687 IN40N3-40W 124205 IN63N3-40W 124206 IN63H3-40W 124226 IN32S3-32W-1100V 123870 IN63N3-50W 124207 IN63H3-50W 124227 IN63N3-63W 124208 IN63H3-63W 124228

Coduri de comanda Intreruptoare-separatoare in aer, tetrapolare


IN26
Fixe Tip Cod comanda Debrosabile Tip Cod comanda Casetele trebuie comandate separat.

53

Capacitate nominala de inchidere la scurtcircuit Icm kA

Curent nominal In = Iu A

Gabarit

Curent nominal admisibil de scurta durata t = 1 s Icw kA

Inclusiv piesele de racord pentru conectare spate si blocul de terminale secundare echipat conform optiunilor comandate pentru intreruptor. 55 800 IN20 50 IN32 IN32 1000 IN20 IN32 IN32 1250 IN20 IN32 IN32 1600 IN20 IN32 IN32 2000 69 800 1000 1250 1600 2000 IN20 IN20 IN20 IN20 IN20 IN20 IN32 IN32 110 2500 2500 3200 3200 138 4000 IN32 IN32 IN32 IN32 IN40 IN63 IN63 210 217 3200 5000 5000 6300 6300 IN32 IN63 IN63 IN63 IN63 65 85 50 65 85 50 65 85 50 65 85 50 65 65 65 65 65 65 85 65 85 65 85 85 85 100 85 100 85 100

IN20B4-08F 123544 IN32B4-08F 124076 IN32N4-08F 124116 IN20B4-10F 123545 IN32B4-10F 124077 IN32N4-10F 124117 IN20B4-12F 123546 IN32B4-12F 124078 IN32N4-12F 124118 IN20B4-16F 123547 IN32B4-16F 124079 IN32N4-16F 124119 IN20B4-20F 123548 IN20N4-08F 123574 IN20N4-10F 123575 IN20N4-12F 123576 IN20N4-16F 123577 IN20N4-20F 123578 IN32B4-20F 124080 IN32N4-20F 124120 IN32B4-25F 124081 IN32N4-25F 124121 IN32B4-32F 124082 IN32N4-32F 124122 IN40N4-40F 124370 IN63N4-40F 124371 IN63H4-40F 124391 IN32S4-32F-1100V 123894 IN63N4-50F 124372 IN63H4-50F 124392 IN63N4-63F 124373 IN63H4-63F 124393

IN20B4-08W 123304 IN32B4-08W 123786 IN32N4-08W 123826 IN20B4-10W 123305 IN32B4-10W 123787 IN32N4-10W 123827 IN20B4-12W 123306 IN32B4-12W 123788 IN32N4-12W 123828 IN20B4-16W 123307 IN32B4-16W 123789 IN32N4-16W 123829 IN20B4-20W 123308 IN20N4-08W 123334 IN20N4-10W 123335 IN20N4-12W 123336 IN20N4-16W 123337 IN20N4-20W 123338 IN32B4-20W 123790 IN32N4-20W 123830 IN32B4-25W 123791 IN32N4-25W 123831 IN32B4-32W 123792 IN32N4-32W 123832 IN40N4-40W 124260 IN63N4-40W 124261 IN63H4-40W 124281 IN32S4-32W-1100V 123872 IN63N4-50W 124262 IN63H4-50W 124282 IN63N4-63W 124263 IN63H4-63W 124283

54

Coduri de comanda Accesorii pentru IZM26


IZM-CAS...,
Curent nominal In A Nr.poli Utilizabil pentru Tip Cod comanda Tip suplimentar "+IZM..." Cod comanda cand se comanda cu aparatul de baza.

Variante debrosabile Caseta in combinatie cu aparatul de baza Echipare standard: Capota pentru camera de stingere Sistem de codare intre caseta si intreruptor Racord orizontal Rama de etansare F 2000 F 2000 2500 - 3200 4000 4000 5000 - 6300 F 2000 F 2000 2500 - 3200 4000 4000 5000 - 6300 Caseta, comanda separata, instalare locala Echipare caseta standard pentru comanda separata Capota pentru camera de stingere Sistem de codare intre caseta si intreruptor Racord orizontal Rama de etansare F 2000 F 2000 2500 - 3200 4000 4000 5000 - 6300 F 2000 F 2000 2500 - 3200 4000 4000 5000 - 6300 3 3 3 3 3 3 4 4 4 4 4 4 IZM20W IN20W IZM32W IN32W IZM32W IN32W IZM40W IN40W IZM63W IN63W IZM63W IN63W IZM20W IN20W IZM32W IN32W IZM32W IN32W IZM40W IN40W IZM63W IN63W IZM63W IN63W +IZM-CAS203-2000 122065 +IZM-CAS323-2000 122066 +IZM-CAS323-3200 122067 +IZM-CAS403-4000 122069 +IZM-CAS633-4000 122710 +IZM-CAS633-6300 122711 +IZM-CAS204-2000 122713 +IZM-CAS324-2000 122714 +IZM-CAS324-3200 122715 +IZM-CAS404-4000 122717 +IZM-CAS634-4000 122718 +IZM-CAS634-6300 122719

3 3 3 3 3 3 4 4 4 4 4 4

IZM20W IN20W IZM32W IN32W IZM32W IN32W IZM40W IN40W IZM63W IN63W IZM63W IN63W IZM20W IN20W IZM32W IN32W IZM32W IN32W IZM40W IN40W IZM63W IN63W IZM63W IN63W

IZM-CAS203-2000 122855 IZM-CAS323-2000 122856 IZM-CAS323-3200 122857 IZM-CAS403-4000 122859 IZM-CAS633-4000 122860 IZM-CAS633-6300 122861 IZM-CAS204-2000 122863 IZM-CAS324-2000 122864 IZM-CAS324-3200 122865 IZM-CAS404-4000 122867 IZM-CAS634-4000 122868 IZM-CAS634-6300 122869

Coduri de comanda Accesorii pentru IZM26


IZM-CAS..., IZM-SH...
Curent nominal In A Nr.poli Utilizabil pentru Tip Cod comanda Tip suplimentar "+IZM..." Cod comanda cand se comanda cu aparatul de baza.

55

Variante debrosabile Caseta 1100 V, in combinatie cu aparatul de baza Echipare standard: Capota pentru camera de stingere Sistem de codare intre caseta si intreruptor Racord orizontal Rama de etansare 3200 3200

3 4

IZM32W-1100V IN32W-1100V IZM32W-1100V IN32W-1100V

+IZM-CAS323-3200-1100V 122712 +IZM-CAS324-3200-1100V 122720

Caseta 1100 V, comanda separata Echipare standard: Capota pentru camera de stingere Sistem de codare intre caseta si intreruptor Racord orizontal Rama de etansare 3200 3200

3 4

IZM32W-1100V IN32W-1100V IZM32W-1100V IN32W-1100V

IZM-CAS323-3200-1100V 122862 IZM-CAS324-3200-1100V 122870

Jaluzele (pentru protectie la atingere) Daca intreruptorul este scos din pozitia "CONECT", jaluzelele se inchid automat si acopera contactele primare. 3 IZM20W IN20W 3 IZM20W IN20W 3 IZM32W IN32W 3 IZM32W IN32W 3 IZM40W IN40W 3 IZM40W IN40W 3 IZM63W IN63W 3 IZM63W IN63W 4 IZM20W IN20W 4 IZM20W IN20W 4 IZM32W IN32W 4 IZM32W IN32W 4 IZM40W IN40W 4 IZM40W IN40W 4 IZM63W IN63W 4 IZM63W IN63W

IZM-SH203 122871 +IZM-SH203 122721 IZM-SH323 122872 +IZM-SH323 122722 IZM-SH403 122873 +IZM-SH403 122723 IZM-SH633 122874 +IZM-SH633 122724 IZM-SH204 122875 +IZM-SH204 122725 IZM-SH324 122876 +IZM-SH324 122726 IZM-SH404 122877 +IZM-SH404 122727 IZM-SH634 122878 +IZM-SH634 122728

56

Coduri de comanda Accesorii pentru IZM26


IZM-CS..., IZM-M..., IZM-OC
Utilizabil pentru Tip Cod comanda Tip suplimentar "+IZM..." Cod comanda cand se comanda cu aparatul de baza. Contact pentru semnalizarea pozitiei Un modul cu 4 contacte comutatoare este suficient pentru indicarea fiecare pozitii a intreruptorului (pozitia conectat, test, deconectat). Doar o placa de montaj necesara la fiecare caseta. Fiecare contact suplimentar (maxim 3) are nevoie de 2 blocuri cu cleme pentru circuite auxiliare IZM-SEC..., sau este posibila conectarea directa la clemele externe. 4 comutatoare: IZM20, 32, 40, 63...W Un modul fara placa de montaj IN20, 32, 40, 63...W 4 comutatoare: Un modul cu placa de montaj 8 comutatoare: Doua module cu placa de montaj 12 comutatoare: Trei module cu placa de montaj Dispozitiv de actionare cu motor Dispozitivul de actionare cu motor armeaza arcurile. Pentru manevrarea electrica este necesar suplimentar un electromagnet de inchidere si un declansator de deschidere. Un contact de semnalizare "arc armat" este inclus in livrare. IZM20, 32, 40, 63... IN20, 32, 40, 63... Indicatii

IZM-CS4 122879 IZM-CS4MB 122880 IZM-CS8MB 122881 IZM-CS12MB 122882

IZM-M24DC 122927 +IZM-M24DC 122729 IZM-M48DC 122928 +IZM-M48DC 122730 IZM-M110DC 122929 +IZM-M110DC 122731 IZM-M220DC 122930 +IZM-M220DC 122732 IZM-M110AC 122931 +IZM-M110AC 122733 IZM-M230AC 122932 +IZM-M230AC 122734

Cand se comanda separat este necesar pentru racordare un bloc de cleme pentru circuite auxiliare IZM-SEC... Comanda suplimentara la cerere. rschema de amplasare a clemelor pag 71

Contor de manevre Pentru memorarea numarului de manevre ON, OFF. Utilizabil si fara dispozitivul de actionare cu motor. IZM20, 32, 40, 63... IN20, 32, 40, 63...

IZM-OC 122933 +IZM-OC 122735

Coduri de comanda Accesorii pentru IZM26


IZM-ST..., IZM-SR...
Tensiune nominala alimentare circuit de comanda Us V Utilizabil pentru

57

Tip Cod comanda Tip suplimentar "+IZM..." Cod comanda cand se comanda cu aparatul de baza.

Indicatii

Declansatoare voltmetrice Un electromagnet de inchidere se poate combina cu un declansator de deschidere si cu unul de minima tensiune sau cu doua declansatoare de deschidere. Declansator de deschidere 24 DC IZM20, 32, 40, 63... IN20, 32,40, 63... 24 DC 48 DC 48 DC 110 - 125 DC 110 - 127 AC 110 - 125 DC 110 - 127 AC 220 - 250 DC 208 - 240 AC 220 - 250 DC 208 - 240 AC Declansator de deschidere nr.2 Nu se poate combina cu un declansator de minima tensiune. 24 DC 48 DC 110 - 127 DC 110 127 AC 208 - 250 DC 208 250 AC Electromagnet de inchidere 110 - 125 DC 110 - 127 AC 110 - 125 DC 110 - 127 AC 220 - 250 DC 208 - 240 AC 220 - 250 DC 208 - 240 AC 24 DC 24 DC 48 DC 48 DC IZM20, 32, 40, 63... IN20, 32,40, 63... IZM-SR110AD 122944 +IZM-SR110AD 122746 IZM-SR230AD 122945 +IZM-SR230AD 122747 IZM-SR24DC 122942 +IZM-SR24DC 122744 IZM-SR48DC 122943 +IZM-SR48DC 122745 Cand se comanda separat este necesar pentru racordare un bloc de cleme pentru circuite auxiliare IZM-SEC... Comanda suplimentara la cerere. rschema de amplasare a clemelor pag 71

IZM-ST24DC 122934 +IZM-ST24DC 122736 IZM-ST48DC 122935 +IZM-ST48DC 122737 IZM-ST110AD 122936 +IZM-ST110AD 122738 IZM-ST230AD 122937 +IZM-ST230AD 122739

Cand se comanda separat este necesar pentru racordare un bloc de cleme pentru circuite auxiliare IZM-SEC... Comanda suplimentara la cerere. rschema de amplasare a clemelor pag 71

IZM20, 32, 40, 63... IN20, 32,40, 63...

+IZM-STS24DC 122740 +IZM-STS48DC 122741 +IZM-STS110AD 122742 +IZM-STS230AD 122743

Cand se comanda separat este necesar pentru racordare un bloc de cleme pentru circuite auxiliare IZM-SEC... Comanda suplimentara la cerere. rschema de amplasare a clemelor pag 71

58

Coduri de comanda Accesorii pentru IZM26


IZM-UVR..., IZM-UVR-TD...
Tensiune nominala alimentare circuit de comanda Us V Declansatoare voltmetrice Declansator de minima tensiune Nu se poate combina cu al doilea declansator de deschidere 24 DC 24 DC 32 DC 32 DC 48 DC 48 DC 110 - 125 DC 110 - 125 DC 220 - 250 DC 220 - 250 DC 110 - 127 AC 110 - 127 AC 208 - 240 AC 208 - 240 AC 380 - 415 AC 380 - 415 AC 480 AC 480 AC 600 AC 600 AC Modul de temporizare Pentru combinarea cu un declansator de minima tensiune. Temporizare: 0.1 s, 0.5 s, 1.0 s, 2.0 s. Doar in combinatie 120 AC IZM20, 32, 40, 63... cu IZM-UVR110AC. IN20, 32,40, 63... Doar in combinatie 230 AC cu IZM-UVR230AC. Utilizabil pentru Tip Cod comanda Tip suplimentar "+IZM..." Cod comanda cand se comanda cu aparatul de baza. Indicatii

IZM20, 32, 40, 63... IN20, 32,40, 63...

IZM-UVR24DC 122946 +IZM-UVR24DC 122748 IZM-UVR32DC 122947 +IZM-UVR32DC 122749 IZM-UVR48DC 122948 +IZM-UVR48DC 122750 IZM-UVR110DC 122949 +IZM-UVR110DC 122751 IZM-UVR220DC 122950 +IZM-UVR220DC 122752 IZM-UVR110AC 122951 +IZM-UVR110AC 122753 IZM-UVR230AC 122952 +IZM-UVR230AC 122754 IZM-UVR400AC 122953 +IZM-UVR400AC 122755 IZM-UVR480AC 122954 +IZM-UVR480AC 122756 IZM-UVR600AC 122955 +IZM-UVR600AC 122757

Cand se comanda separat este necesar pentru racordare un bloc de cleme pentru circuite auxiliare IZM-SEC... Comanda suplimentara la cerere. rschema de amplasare a clemelor pag 71

IZM-UVR-TD-120AC 122956 IZM-UVR-TD-230AC 122957

Coduri de comanda Accesorii pentru IZM26


IZM-AS..., IZM-LCS..., IZM-OTS..., IZM-RR...,
Utilizabil pentru

59

Tip Cod comanda Tip suplimentar "+IZM..." Cod comanda cand se comanda cu aparatul de baza.

Indicatii

Contacte auxiliare Contact auxiliar standard pentru semnalizare ON, OFF. 2 comutatoare sunt incluse in aparatul de baza. Maxim pentru IZM20, IN20: 4 comutatoare (contin suplimentar un AS22). Maxim pentru IZM32, IZM40, IZM63: 6 comutatoare (contin suplimentar doua AS22 sau suplimentar un AS44). 6 comutatoare sunt posibile doar daca nu este instalat declansatorul de deschidere nr.2 2 comutatoare suplimentare IZM20, 32, 40, 63... IN20, 32, 40, 63... 4 comutatoare suplimentare 2 comutatoare suplimentare

+IZM-AS22 122758 +IZM-AS44 122759 IZM-AS22 122958

Nu este combinabil cu declansatorul de deschidere nr.2 si nici cu IZM20, IN20. Cand se comanda separat este necesar pentru racordare un bloc de cleme pentru circuite auxiliare IZM-SEC... Comanda suplimentara la cerere. rschema de amplasare a clemelor pag 71

Semnalizare "pregatit de inchidere" Semnalizare "pregatit de inchidere"cu un contact comutator. IZM20, 32, 40, 63... IN20, 32, 40, 63...

IZM-LCS-SR 122974 +IZM-LCS-SR 122760 IZM-LCS 122959 +IZM-LCS 122761

Conectat intern cu un electromagnet de inchidere Conectat intern cu un electromagnet de inchidere Pentru semnalizare externa Pentru semnalizare externa

Tensiune nominala alimentare circuit de comanda Us V Semnalizari de declansare si optiuni de resetare Contact semnalizare de declansare (OTS) 2 contacte comutatoare

Utilizabil pentru

Tip Cod comanda Tip suplimentar "+IZM..." Cod comanda cand se comanda cu aparatul de baza.

Indicatii

IZM20, 32, 40, 63...

IZM-OTS 122960 +IZM-OTS 122762

Cand se comanda separat este necesar pentru racordare un bloc de cleme pentru circuite auxiliare IZM-SEC... Comanda suplimentara la cerere. r schema de amplasare a clemelor pag 71

Resetare de la distanta Prin comanda de la distanta pot fi resetate semnalizarea de declansare cat si semnalizare locala (stift rosu). Nu se combina cu resetarea automata. 220 - 250 DC IZM20, 32, 40, 63... 208 - 240 AC 220 - 250 DC 208 - 240 AC 24 DC 24 DC 110 - 125 DC 110 - 127 AC 110 - 125 DC 110 - 127 AC Resetare automata Intreruptorul automat este pregatit imediat de inchidere. Semnalizarea declansarii mecanice (stift rosu) nu este echipata. Nu se combina cu restarea la distanta. IZM20, 32, 40, 63...

IZM-RR230AD 122963 +IZM-RR230AD 122765 IZM-RR24DC 122961 +IZM-RR24DC 122763 IZM-RR110AD 122962 +IZM-RR110AD 122764

Cand se comanda separat este necesar pentru racordare un bloc de cleme pentru circuite auxiliare IZMSEC...Comanda suplimentara la cerere. rschema de amplasare a clemelor pag 71

IZM-RA 122964 +IZM-RA 122766

60

Coduri de comanda Accesorii pentru IZM26


IZM-PLPC..., IZM-KLC..., IZM-KLP...

Utilizabil pentru

Tip Cod comanda Tip suplimentar "+IZM..." Cod comanda cand se comanda cu aparatul de baza.

Mecanisme de blocare Butoane blocabile ON/OFF Capac cu lacat si posibilitate de sigilare pentru butoanele ON/OFF Material metalic, tasta ON blocata Material plastic, tasta ON blocata Material metalic Material metalic Material plastic Material plastic Blocare cu cheie in OFF Kit blocare cu cheie, CES, inclusiv broasca cilindrica si cheie Kit blocare cu cheie, CES, inclusiv broasca cilindrica si cheie Kit instalare interblocare cu cheie, CES, fara broasca cilindrica si cheie Kit instalare interblocare cu cheie, CES, fara broasca cilindrica si cheie Kit instalare interblocare cu cheie, Kirk, fara broasca cilindrica si cheie Kit instalare interblocare cu cheie, Kirk, fara broasca cilindrica si cheie Kit instalare interblocare cu cheie, Castell, fara broasca cilindrica si cheie Kit instalare interblocare cu cheie, Castell, fara broasca cilindrica si cheie Kit instalare interblocare cu cheie, Ronis, fara broasca cilindrica si cheie Kit instalare interblocare cu cheie, Ronis, fara broasca cilindrica si cheie

IZM20, 32, 40, 63... IN20, 32, 40, 63...

+IZM-PLPC-CB-M 125820 +IZM-PLPC-CB-P 125649 IZM-PLPC-M 122966 +IZM-PLPC-M 122768 IZM-PLPC-P 122965 +IZM-PLPC-P 122767 IZM-KLC-SO-CES 122967 +IZM-KLC-SO-CES 122769 IZM-KLP-SO-CES 122968 +IZM-KLP-SO-CES 122770 IZM-KLP-SO-KIRK 122969 +IZM-KLP-SO-KIRK 122771 IZM-KLP-SO-CASTELL 122970 +IZM-KLP-SO-CASTELL 122772 IZM-KLP-SO-RONIS 122971 +IZM-KLP-SO-RONIS 122773

IZM20, 32, 40, 63... IN20, 32, 40, 63...

Kit interblocare caseta Cand este instalat, intreruptorul nu se poate comuta daca el se afla in pozitia CONECT. Aceasta previne inchiderea intreruptorului si alimentarea circuitului. Montaj pe partea dreapta IZM20, 32, 40, 63...W IN20, 32, 40, 63...W Montaj pe partea stanga

IZM-KLP-CASS-R 122972 IZM-KLP-CASS-L 122973

Coduri de comanda Accesorii pentru IZM26


IZM-MIL...
Utilizabil pentru

61

Tip Cod comanda

Mecanisme de interblocare Interblocare mecanica, intreruptoare montaj fix Tip 2, intre 2 intreruptoare automate: o alimentare normala (A) si o alimentare de urgenta (B). Este necesar 1 kit de cabluri. Tip 31, intre 3 intreruptoare automate: 2 alimentari normale (A + C) si o alimentare de urgenta (B). Daca B este deschis, A si C pot fi inchise. B poate fi inchis daca A si C sunt deschise. Sunt necesare 2 kit-uri de cabluri. Tip 32, intre 3 intreruptoare automate:2 alimentari normale (A + C) si o cupla (B). Unul sau 2 intreruptoare din 3 pot fi inchise in acelasi timp. Sunt necesare 3 kit-uri de cabluri. Tip 33, intre 3 intreruptoare automate:3 alimentari normale sau de urgenta (A, B + C), doar unul din ele poate fi inchis la un moment dat. Sunt necesare 3 kit-uri de cabluri. Interblocare mecanica, intreruptoare in montaj debrosabil Tip 2, intre 2 intreruptoare automate: o alimentare normala (A) si o alimentare de urgenta (B). Este necesar 1 kit de cabluri. Tip 31, intre 3 intreruptoare automate: 2 alimentari normale (A + C) si o alimentare de urgenta (B). Daca B este deschis, A si C pot fi inchise. B poate fi inchis daca A si C sunt deschise. Sunt necesare 2 kit-uri de cabluri. Tip 32, intre 3 intreruptoare automate:2 alimentari normale (A + C) si o cupla (B). Unul sau 2 intreruptoare din 3 pot fi inchise in acelasi timp. Sunt necesare 3 kit-uri de cabluri. Tip 33, intre 3 intreruptoare automate:3 alimentari normale sau de urgenta (A, B + C), doar unul din ele poate fi inchis la un moment dat. Sunt necesare 3 kit-uri de cabluri. Kituri de cabluri pentru interblocaj mecanic. In functie de tipul de interblocaj mecanic seturile de cabluri pot fi diferite. Cablurile pot fi folosite pentru orice pozitie a intreruptorului. 1 kit este alcatuit din 2 cabluri. 1520 mm lungime 1830 mm lungime 2440 mm lungime 3050 mm lungime

IZM20, 32, 40, 63...F IN20, 32, 40, 63...F

IZM-MIL2C-F 122980 IZM-MIL31C-F 122981

IZM-MIL32C-F 122982

IZM-MIL33C-F 122983

IZM20, 32, 40, 63...W IN20, 32, 40, 63...W

IZM-MIL2C-W 122985 IZM-MIL31C-W 122986

IZM-MIL32C-W 122987

IZM-MIL33C-W 122988

IZM20, 32, 40, 63... IN20, 32, 40, 63...

IZM-MIL-CAB1520 122975 IZM-MIL-CAB1830 122976 IZM-MIL-CAB2440 122977 IZM-MIL-CAB3050 122978

62

Coduri de comanda Accesorii pentru IZM26


IZM-DTV..., IZM-DTU...
Tensiune nominala alimentare circuit de comanda Us V Optiuni si accesorii pentru declansatoare electronice Echiparea standard pentru intreruptoarele automate IZM include unul din urmatoarele declansatoare la supracurent (DT = Digitrip): Tip A: DT-520LI Tip V: DT-520LSI Tip U: DT-520MC Tip P: DT-1150 Functie suplimentara pentru intreruptorul automat pentru protectie selectiva tip V (Digitrip 520LSI) Protectie la defecte cu pamantul IZM-V (Digitrip 520LSI) Functie suplimentara pentru intreruptorul automat pentru protectie universala tip U (Digitrip 520MC) Echiparea standard pentru intreruptorul automat tip U: Compatibilitate COM Alarma la suprasarcina cu contact de semnalizare Pregatit pentru sursa externa (de ex. pentru Display) 24/48 V c.c. Doar una din urmatoarele trei optiuni este posibila in acelasi timp : fie protectia la defecte cu pamantul, alarma la defecte cu pamantul sau alarma la suprasarcina. Pentru comunicatii este disponibil suplimentar un modul de interfata IZM-DTUP-DP(MOD) . IZM-U cu alarma suprasarcina, sursa de alimentare 120 AC (Digitrip 520MC) externa pentru 120 V c.a. in loc de 24/48 V c.c. cu alarma suprasarcina, sursa de alimentare 240 AC externa pentru 240 V c.a. in loc de 24/48 V c.c. cu protectie la defecte cu pamantul in loc de 24/48 DC alarma suprasarcina, pregatit pentru 24/48 V c.c. cu protectie la defecte cu pamantul in loc de 120 AC alarma suprasarcina pregatit pentru 120 V c.a. cu protectie la defecte cu pamantul in loc de 240 AC alarma suprasarcina pregatit pentru 240 V c.a. cu alarma la defecte cu pamantul in loc de 24/48 DC alarma suprasarcina pregatit pentru 24/48 V c.c. cu alarma la defecte cu pamantul in loc de 120 AC alarma suprasarcina pregatit pentru 120 V c.a. cu alarma la defecte cu pamantul in loc de 240 AC alarma suprasarcina pregatit pentru 240 V c.a. Functia ARMS (Arcflash Reduction Mainte nance SystemTM) poate sa reduca durata defectului printr-o metoda simpla si viabila ce creste siguranta. Trebuie activata. Performanta redusa (NC): Intreruptorul auto- mat tip U nu se livreaza cu posibilitatea de comunicatie. Performanta redusa (NPC): Intreruptorul automat tip U nu se livreaza cu posibilitatea de comunicatie si nici cu elementele necesare alimentarii la o sursa externa. Utilizabil pentru Tip Cod comanda Tip suplimentar "+IZM..." Cod comanda cand se comanda cu aparatul de baza. Indicatii

+IZM-DTV-EP 122776

+IZM-DTU-HA1 122778 +IZM-DTU-HA2 122779 +IZM-DTU-EP 122780 +IZM-DTU-EP1 122781 +IZM-DTU-EP2 122782 +IZM-DTU-EA 122783 +IZM-DTU-EA1 122784 +IZM-DTU-EA2 122785 +IZM-DTU-ARMS 122791

Nu se combina cu protectia sau alarma la defecte cu pamantul. Nu se combina cu protectia sau alarma la defecte cu pamantul. Nu se combina cu alarma la suprasarcina sau defecte cu pamantul. Nu se combina cu alarma la suprasarcina sau defecte cu pamantul. Nu se combina cu alarma la suprasarcina sau defecte cu pamantul. Nu se combina cu alarma la suprasarcina sau protectia la defecte cu pamantul. Nu se combina cu alarma la suprasarcina sau protectia la defecte cu pamantul. Nu se combina cu alarma la suprasarcina sau protectia la defecte cu pamantul.

+IZM-DTU-NC 122790 +IZM-DTU-NPC 122788

Nu se combina cu: IZM-DTU-NPC IZM-DTU-ARMS Doar in combinatie cu IZM-DTUEP. Nu se combina cu alte optiuni.

Coduri de comanda Accesorii pentru IZM26


IZM-DTP..., IZM-DTUP..., IZM-TEST...
Tensiune nominala alimentare circuit de comanda Us V Utilizabil pentru

63

Tip Cod comanda Tip suplimentar "+IZM..." Cod comanda cand se comanda cu aparatul de baza.

Functie suplimentara pentru intreruptorul automat pentru protectie universala tip P (Digitrip 1150) Echiparea standard pentru intreruptorul automat tip P: Masurarea energiei Posibilitate de comunicatie Alarma la suprasarcina cu contact de semnalizare Pregatita pentru sursa externa (de ex. pentru Display) 24/48 V c.c. Protectia si alarma la defecte cu pamantul pot fi combinate (IZM-DTP-EPA). Se pot combina cu alarma la suprasarcina. Pentru comunicatii este necesar suplimentar un modul de interfata IZM-DTUP-DP(MOD). cu alarma suprasarcina, pentru 120 V c.a. sursa de alimentare externa in loc de 120 AC 24/48 V c.c. cu alarma suprasarcina, pentru 240 V AC sursa de alimentare externa in loc de 240 AC 24/48 V c.c. cu protectie si alarma la impamantare suplimentare pentru 24/48 V c.c. 24/48 DC cu protectie si alarma la impamantare suplimentare pentru 120 V c.a. cu protectie si alarma la impamantare suplimentare pentru 240 V c.a. Functia ARMS (Arcflash Reduction Maintenance SystemTM) poate sa reduca timpul erorilor printr-o metoda simpla si viabila ce creste siguranta. Trebuie activata. Alimentarea se face de jos in sus: se schimba partea dinspre sursa pentru a efectua masurari corecte a energiei. TripLink transfera parametrii de protectie de la un intreruptor la altul, de ex. la inlocuirea unui intreruptor cu unul la fel . 120 AC 240 AC

IZM-P (Digitrip 1150)

+IZM-DTP1 122895 +IZM-DTP2 122906 +IZM-DTP-EPA 122915 +IZM-DTP-EPA1 122916 +IZM-DTP-EPA2 122938 +IZM-DTP-ARMS 122939 +IZM-DTP-PFBT 122990 IZM-DTP-TL 122989

Tensiune nominala alimentare circuit de comanda Us V Comunicabilitate pentru Digitrip 520MC si 1150 Comunicatie PROFIBUS cu posibilitate de montare pe sina Comunicatie MODBUS cu posibilitate de montare pe sina

Utilizabil pentru

Tip Cod comanda

IZM-U (Digitrip 520MC) IZM-P (Digitrip 1150)

IZM-DTUP-DP 122991 IZM-DTUP-MOD 122992

Aparat de testare manual pentru Digitrip Aparat de testare manual pentru Digitrip 520LI (Tip A), Digitrip 520LSI (Tip V) si Digitrip 520MC (Tip U). Digitrip 1150 (Tip P) dispune de functii de testare integrate.

120 AC 240 AC

IZM-A (Digitrip 520LI) IZM-V (Digitrip 520LSI) IZM-U (Digitrip 520M)

IZM-TEST-120VAC 122993 IZM-TEST-230VAC 122994

64

Coduri de comanda Accesorii pentru IZM26


IZM-RP...
Curent nominal In A Nr.poli Utilizabil pentru Tip Cod comanda Tip suplimentar "+IZM..." Cod comanda cand se comanda cu aparatul de baza.

Combinatii fisa curent nominal-senzor Aceasta combinatie este necesara, daca trebuie redus curentul nominal la un intreruptor. 200 3 IZM20 800 A F Iu F 2000 A 200 3 IZM20 800 A F Iu F 2000 A 250 3 IZM20 800 A F Iu F 2000 A 250 3 IZM20 800 A F Iu F 2000 A 300 3 IZM20 800 A F Iu F 2000 A 300 3 IZM20 800 A F Iu F 2000 A 400 3 IZM20 800 A F Iu F 2000 A 400 3 IZM20 800 A F Iu F 2000 A 630 3 IZM20 800 A F Iu F 2000 A 630 3 IZM20 800 A F Iu F 2000 A 800 3 IZM20 800 A F Iu F 2000 A 800 3 IZM20 800 A F Iu F 2000 A 1000 3 IZM20 1000 A F Iu F 2000 A 1000 3 IZM20 1000 A F Iu F 2000 A 1250 3 IZM20 1250 A F Iu F 2000 A 1250 3 IZM20 1250 A F Iu F 2000 A 1600 3 IZM20 1600 A F Iu F 2000 A 1600 3 IZM20 1600 A F Iu F 2000 A 2000 3 IZM20 2000 A 200 200 250 250 300 300 400 400 630 630 800 800 3 3 3 3 3 3 3 3 3 3 3 3 IZM32 800 A F Iu F 3200 A IZM32 800 A F Iu F 3200 A IZM32 800 A F Iu F 3200 A IZM32 800 A F Iu F 3200 A IZM32 800 A F Iu F 3200 A IZM32 800 A F Iu F 3200 A IZM32 800 A F Iu F 3200 A IZM32 800 A F Iu F 3200 A IZM32 800 A F Iu F 3200 A IZM32 800 A F Iu F 3200 A IZM32 800 A F Iu F 3200 A IZM32 800 A F Iu F 3200 A IZM-RP203-200 122995 +IZM-RP203-200 122793 IZM-RP203-250 122996 +IZM-RP203-250 122794 IZM-RP203-300 122997 +IZM-RP203-300 122795 IZM-RP203-400 122998 +IZM-RP203-400 122796 IZM-RP203-630 122999 +IZM-RP203-630 122797 IZM-RP203-800 123000 +IZM-RP203-800 122798 IZM-RP203-1000 123001 +IZM-RP203-1000 122799 IZM-RP203-1250 123002 +IZM-RP203-1250 122800 IZM-RP203-1600 123003 +IZM-RP203-1600 122801 IZM-RP203-2000 123004 IZM-RP323-200 123005 +IZM-RP323-200 122803 IZM-RP323-250 123006 +IZM-RP323-250 122804 IZM-RP323-300 123007 +IZM-RP323-300 122805 IZM-RP323-400 123008 +IZM-RP323-400 122806 IZM-RP323-630 123009 +IZM-RP323-630 122807 IZM-RP323-800 123010 +IZM-RP323-800 122808

Coduri de comanda Accesorii pentru IZM26


IZM-RP...
Curent nominal In A Nr.poli Utilizabil pentru

65

Tip Cod comanda Tip suplimentar "+IZM..." Cod comanda cand se comanda cu aparatul de baza.

Combinatii fisa curent nominal-senzor Aceasta combinatie este necesara, daca trebuie redus curentul nominal la un intreruptor. 1000 3 IZM32 1000 A F Iu F 3200 A 1000 3 IZM32 1000 A F Iu F 3200 A 1250 3 IZM32 1250 A F Iu F 3200 A 1250 3 IZM32 1250 A F Iu F 3200 A 1600 3 IZM32 1600 A F Iu F 3200 A 1600 3 IZM32 1600 A F Iu F 3200 A 2000 3 IZM32 2000 A F Iu F 3200 A 2000 3 IZM32 2000 A F Iu F 3200 A 2500 3 IZM32 2500 A F Iu F 3200 A 2500 3 IZM32 2500 A F Iu F 3200 A 3200 3 IZM32... 3200 A 2000 2000 2500 2500 3200 3200 4000 2000 2000 2500 2500 3200 3200 4000 4000 5000 5000 6300 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 IZM40 2000 A F Iu F 4000 A IZM40 2000 A F Iu F 4000 A IZM40 2500 A F Iu F 4000 A IZM40 2500 A F Iu F 4000 A IZM40 3200 A F Iu F 4000 A IZM40 3200 A F Iu F 4000 A IZM40 4000 A IZM63 4000 A IZM63 4000 A IZM63 4000 A F Iu F 5000 A IZM63 4000 A F Iu F 5000 A IZM63 4000 A F Iu F 6300 A IZM63 4000 A F Iu F 6300 A IZM63 4000 A F Iu F 6300 A IZM63 4000 A F Iu F 6300 A IZM63 5000 A F Iu F 6300 A IZM63 5000 A F Iu F 6300 A IZM63 6300 A IZM-RP323-1000 123011 +IZM-RP323-1000 122809 IZM-RP323-1250 123012 +IZM-RP323-1250 122810 IZM-RP323-1600 123013 +IZM-RP323-1600 122811 IZM-RP323-2000 123014 +IZM-RP323-2000 122812 IZM-RP323-2500 123015 +IZM-RP323-2500 122813 IZM-RP323-3200 123016 IZM-RP403-2000 123017 +IZM-RP403-2000 122815 IZM-RP403-2500 123018 +IZM-RP403-2500 122816 IZM-RP403-3200 123019 +IZM-RP403-3200 122817 IZM-RP403-4000 122802 IZM-RP633-2000 124244 +IZM-RP633-2000 124319 IZM-RP633-2500 124320 +IZM-RP633-2500 124209 IZM-RP633-3200 124210 +IZM-RP633-3200 124374 IZM-RP633-4000 123023 +IZM-RP633-4000 122821 IZM-RP633-5000 123024 +IZM-RP633-5000 122822 IZM-RP633-6300 123025

66

Coduri de comanda Accesorii pentru IZM26


IZM-RP...
Curent nominal In A Nr.poli Utilizabil pentru Tip Cod comanda Tip suplimentar "+IZM..." Cod comanda cand se comanda cu aparatul de baza.

Combinatii fisa curent nominal-senzor Aceasta combinatie este necesara, daca trebuie redus curentul nominal la un intreruptor. 200 4 IZM20 800 A F Iu F 2000 A 200 4 IZM20 800 A F Iu F 2000 A 250 4 IZM20 800 A F Iu F 2000 A 250 4 IZM20 800 A F Iu F 2000 A 300 4 IZM20 800 A F Iu F 2000 A 300 4 IZM20 800 A F Iu F 2000 A 400 4 IZM20 800 A F Iu F 2000 A 400 4 IZM20 800 A F Iu F 2000 A 630 4 IZM20 800 A F Iu F 2000 A 630 4 IZM20 800 A F Iu F 2000 A 800 4 IZM20 800 A F Iu F 2000 A 800 4 IZM20 800 A F Iu F 2000 A 1000 4 IZM20 1000 A F Iu F 2000 A 1000 4 IZM20 1000 A F Iu F 2000 A 1250 4 IZM20 1250 A F Iu F 2000 A 1250 4 IZM20 1250 A F Iu F 2000 A 1600 4 IZM20 1600 A F Iu F 2000 A 1600 4 IZM20 1600 A F Iu F 2000 A 2000 4 IZM20 2000 A 200 4 IZM32 800 A F Iu F 3200 A 200 4 IZM32 800 A F Iu F 3200 A 250 4 IZM32 800 A F Iu F 3200 A 250 4 IZM32 800 A F Iu F 3200 A 300 4 IZM32 800 A F Iu F 3200 A 300 4 IZM32 800 A F Iu F 3200 A 400 4 IZM32 800 A F Iu F 3200 A 400 4 IZM32 800 A F Iu F 3200 A 630 4 IZM32 800 A F Iu F 3200 A 630 4 IZM32 800 A F Iu F 3200 A 800 4 IZM32 800 A F Iu F 3200 A 800 4 IZM32 800 A F Iu F 3200 A IZM-RP204-200 123026 +IZM-RP204-200 122824 IZM-RP204-250 123027 +IZM-RP204-250 122825 IZM-RP204-300 123028 +IZM-RP204-300 122826 IZM-RP204-400 123029 +IZM-RP204-400 122827 IZM-RP204-630 123030 +IZM-RP204-630 122828 IZM-RP204-800 123031 +IZM-RP204-800 122829 IZM-RP204-1000 123032 +IZM-RP204-1000 122830 IZM-RP204-1250 123033 +IZM-RP204-1250 122831 IZM-RP204-1600 123034 +IZM-RP204-1600 122832 IZM-RP204-2000 123035 IZM-RP324-200 123036 +IZM-RP324-200 122834 IZM-RP324-250 123037 +IZM-RP324-250 122835 IZM-RP324-300 123038 +IZM-RP324-300 122836 IZM-RP324-400 123039 +IZM-RP324-400 122837 IZM-RP324-630 123040 +IZM-RP324-630 122838 IZM-RP324-800 123041 +IZM-RP324-800 122839

Coduri de comanda Accesorii pentru IZM26


IZM-RP...
Curent nominal In A Nr.poli Utilizabil pentru Tip Cod comanda Tip suplimentar "+IZM..." Cod comanda cand se comanda cu aparatul de baza.

67

Combinatia fisa curent nominal-senzor Aceasta combinatie este necesara, daca trebuie redus curentul nominal la un intreruptor. 1000 4 IZM32 1000 A F Iu F 3200 A 1000 4 IZM32 1000 A F Iu F 3200 A 1250 4 IZM32 1250 A F Iu F 3200 A 1250 4 IZM32 1250 A F Iu F 3200 A 1600 4 IZM32 1600 A F Iu F 3200 A 1600 4 IZM32 1600 A F Iu F 3200 A 2000 4 IZM32 2000 A F Iu F 3200 A 2000 4 IZM32 2000 A F Iu F 3200 A 2500 4 IZM32 2500 A F Iu F 3200 A 2500 4 IZM32 2500 A F Iu F 3200 A 3200 4 IZM32 3200 A 2000 4 IZM40 2000 A F Iu F 4000 A 2000 4 IZM40 2000 A F Iu F 4000 A 2500 4 IZM40 2500 A F Iu F 4000 A 2500 4 IZM40 2500 A F Iu F 4000 A 3200 4 IZM40 3200 A F Iu F 4000 A 3200 4 IZM40 3200 A F Iu F 4000 A 4000 4 IZM40 4000 A 2000 4 IZM63 4000 A 2000 4 IZM63 4000 A 2500 4 IZM63 4000 A F Iu F 5000 A 2500 4 IZM63 4000 A F Iu F 5000 A 3200 4 IZM63 4000 A F Iu F 6300 A 3200 4 IZM63 4000 A F Iu F 6300 A 4000 4 IZM63 4000 A F Iu F 6300 A 4000 4 IZM63 4000 A F Iu F 6300 A 5000 4 IZM63 5000 A F Iu F 6300 A 5000 4 IZM63 5000 A F Iu F 6300 A 6300 4 IZM63 6300 A IZM-RP324-1000 123042 +IZM-RP324-1000 122840 IZM-RP324-1250 123043 +IZM-RP324-1250 122841 IZM-RP324-1600 123044 +IZM-RP324-1600 122842 IZM-RP324-2000 123045 +IZM-RP324-2000 122843 IZM-RP324-2500 123046 +IZM-RP324-2500 122844 IZM-RP324-3200 123047 IZM-RP404-2000 123048 +IZM-RP404-2000 122846 IZM-RP404-2500 123049 +IZM-RP404-2500 122847 IZM-RP404-3200 123050 +IZM-RP404-3200 122848 IZM-RP404-4000 122814 IZM-RP634-2000 124321 +IZM-RP634-2000 124264 IZM-RP634-2500 124211 +IZM-RP634-2500 124299 IZM-RP634-3200 124322 +IZM-RP634-3200 124354 IZM-RP634-4000 123054 +IZM-RP634-4000 122852 IZM-RP634-5000 123055 +IZM-RP634-5000 122853 IZM-RP634-6300 123056

68

Coduri de comanda Accesorii pentru IZM26


IZM-CTN...
Curent nominal In A Senzor de curent pentru conductorul de nul Pentru protectia nulului sau protectia la defecte cu pamantul este necesar un senzor pentru intreruptorul automat tripolar 200 IZM20... IZM32 250 IZM20... IZM32 300 IZM20... IZM32 400 IZM20... IZM32 630 IZM20... IZM32 800 IZM20... IZM32 1000 IZM20... IZM32 1250 IZM20... IZM32 1600 IZM20... IZM32 2000 IZM20... IZM32 2500 IZM32 3200 4000 5000 6300 IZM32 IZM40... IZM63... IZM63 IZM63 IZM-CTN-200 123057 IZM-CTN-250 123058 IZM-CTN-300 123059 IZM-CTN-400 123060 IZM-CTN-630 123061 IZM-CTN-800 123062 IZM-CTN-1000 123063 IZM-CTN-1250 123064 IZM-CTN-1600 123065 IZM-CTN-2000 123066 IZM-CTN-2500 123067 IZM-CTN-3200 123068 IZM-CTN-4000 123069 IZM-CTN-5000 123070 IZM-CTN-6300 123071 Utilizabil pentru Tip Cod comanda

Coduri de comanda Accesorii pentru IZM26


IZM-TV..., IZM-TF...
Curent nominal In A Set de racorduri principale Fiecare aparat din seria IZM26 va fi livrat standard cu racorduri orizontale. Racorduri verticale pentru tipul fix sau debrosabil F 2000 F 65 4000 F 2000 4000 F 1600 F 2000 2500 - 3200 F 1600 F 2000 2500 - 3200 4000 5000 - 6300 4000 5000 - 6300 Racorduri frontale pentru tipul fix sau debrosabil F 1250 F 1250 100 F 65 100 F 65 F 100 100 F 65 F 100 100 100 100 100 100 Capacitate de rupere la scurtcircuit nominala Icu kA Nr.poli Utilizabil pentru

69

Tip Cod comanda

3 3 4 4 3 3 3 4 4 4 3 3 4 4

IZM20 IN20 IZM40 IN40 IZM20 IN20 IZM40 IN40 IZM32 IN32 IZM32B20 IN32B20 IZM32H, IN32H IZM32 IN32 IZM32 IN32 IZM32B20 IN32B20 IZM32H, IN32H IZM32 IN32 IZM63 IN63 IZM63 IN63 IZM63 IN63 IZM63 IN63 IZM20 IN20 IZM20 IN20

IZM-TV203N-2000 123072 IZM-TV403H-4000 123081 IZM-TV204N-2000 123086 IZM-TV404H-4000 123095 IZM-TV323B-1600 123074 IZM-TV323H-2000 123075 IZM-TV323H-3200 123077 IZM-TV324B-1600 123088 IZM-TV324H-2000 123089 IZM-TV324H-3200 123091 IZM-TV633H-4000 123082 IZM-TV633H-6300 123084 IZM-TV634H-4000 123096 IZM-TV634H-6300 123098 IZM-TF203N-1250 123100 IZM-TF204N-1250 123108

F 65 F 65

3 4

1600 - 2000 4000 F 2000 4000 F 1250 1600 - 2500 F 3200

F 65 100 F 65 100 F 65 F 65 F 100

3 3 4 4 3 3 3

F 1250 F 2500 F 3200

F 65 F 65 F 100

4 4 4

IZM20 IN20 IZM40 IN40 IZM20 IN20 IZM40 IN40 IZM32B IN32B IZM32B IN32B IZM32B32... IN32B32 IZM32N, IN32N IZM32H, IN32H IZM32B IN32B IZM32B IN32B IZM32B32... IN32B32 IZM32N, IN32N IZM32H, IN32H

IZM-TF203N-2000 123102 IZM-TF403H-4000 123107 IZM-TF204N-2000 123110 IZM-TF404H-4000 123115 IZM-TF323B-1250 124225 IZM-TF323B-2500 123104 IZM-TF323H-3200 123105

IZM-TF324B-1250 124280 IZM-TF324B-2500 123112 IZM-TF324H-3200 123113

70

Coduri de comanda Accesorii pentru IZM26


IZM-SEC..., IZM-DEG..., IZM-DC..., IZM-LY...,
Tensiune nominala alimentare circuit de comanda Us V Utilizabil pentru Tip Cod comanda

Accesorii generale Kit de cleme auxiliare, 2 blocuri Doua blocuri de cleme, fiecare cu 6 puncte de racordare conductoare auxiliare, cu etichete, dispozitiv AMP si cabluri interne. IZM20, 32, 40, 63... IN20, 32, 40, 63... Kit de cleme auxiliare, 15 blocuri 15 blocuri de cleme, fiecare cu 6 puncte de racordare conductoare auxiliare, cu etichete. Cablarea interna se comanda separat. IZM20, 32, 40, 63... IN20, 32, 40, 63... Set de cabluri pentru circuite auxiliare Kit conductoare cablare interna, 90 conductoare suficiente pentru 15 blocuri de cleme. IZM20, 32, 40, 63... IN20, 32, 40, 63... Rama de etansare -piesa de schimb, IP31 Piesa de schimb, o rama de etansare este inclusa in livrarea standard a aparatului de baza/ casetei. IZM20, 32, 40, 63... IN20, 32, 40, 63...

IZM-SEC-TB2 123116

IZM-SEC-TB15 123117

IZM-SEC-WR90 122789

IZM-DEG 122925

Capac de protectie, IP54 IZM20, 32, 40, 63... IN20, 32, 40, 63... IZM-DC 122926

Dispozitiv pentru ridicare Contine doua carlige din otel de forma speciala, utilizate la prinderea intreruptorului de manerele din carcasa si la ridicarea lui. 3 IZM20 IN20 3 IZM32 IN32 3 IZM40 IN40 3 IZM63 IN63 4 IZM20 IN20 4 IZM32 IN32 4 IZM40 IN40 4 IZM63 IN63 Macara mobila Ridica intreruptorul cu ajutorul dispozitivului. IZM20, 32, 40, 63... IN20, 32, 40, 63...

IZM-LY203 123118 IZM-LY323 123119 IZM-LY403 123120 IZM-LY633 123121 IZM-LY204 123122 IZM-LY324 123123 IZM-LY404 123124 IZM-LY634 123125

IZM-CRANE 123126

Indrumari de proiectare Schema de conectare a circuitelor auxiliare


IZM26

71

Intern
Semnal resoarte armate
Releu digital -module auxiliare (A-Bus)

Cleme
A16 A17 A18 A19 A20 A21

Intern

Cleme
A1 A2 A3 A4 A5 A6

Contact semnalizare declansare (OTS) 1

Contact semnalizari declansare (OTS) 2

Contacte auxiliare ON/OFF, bloc 3

A22 A23 A24 A25 A26 A27 A28

Declansator de minima tensiune

A7 A8 A9 A10 A11 A12

Modul releu intern

Alimentare modul releu intern INCOM validare inchidere de la distanta Magistala interna a sistemului INCOM NPOW Intrare de la senzor neutru Intrare neutru stea transformator Selectivitate zonala ZSI

A13 A14 A15 B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12 B13


M

Contacte auxiliare ON/OFF, bloc 2

A29 A30 B16 B17 B18 B19 B20 B21 B22

Contacte auxiliare ON/OFF, bloc 1

B23 B24 B25 B26 B27 B28 B29 B30

Declansator deschidere Electromagnet inchidere Actionare cu motor

Semnalizare "Pregatit de inchidere"

B14 B15

72

Indrumari de proiectare Curbe de declansare IZM26


IZM26A(V)(U)(P)...
IZM26A... Curbe de declansare pentru protectie instalatii Protectie la suprasarcina (L) si protectie la scurt-circuit instantanee (I) Protectie L: reglabila Vezi indicatii 1 pana la 3.
10000 9000 8000 2 h 7000 6000 5000 4000 1h 3000 2000

Protectie I: reglabila Vezi indicatii 3 pana la 7.


10 9 8 7 6 5 4 3 2

t [s]

t [s]

0.4 - 1 x In = Ir (0.4, 0.5, 0.6, 0.7, 0.8, 0.9, 1.0)

c b d

j h
2 - 10 x In g 10

1000 900 800 700 600 500 400 300 200

1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2

1 min

100 90 80 70 60 50 40 30 20

0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03


24

0.02 1230DIA-103 (70C1296) 0.5 0.7 0.9 0.6 0.8 1 2 3 4 5 6 7 8 9 10 20 30 40 50 60 80 100


I/In

15

10 9 8 7 6 5 4 3 2

D
7

0.01

Isd = 6 x Ir (2, 4, 7, 10, 12, 15, 20, 24 s + 0/- 30 )

Protectie I: Declansare instantanee pentru curenti mari Vezi indicatii 3 pana la 7.


1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2

0.5 0.7 0.9 0.6 0.8 1

4 5 6 7 8 9 10

20

30 40 50 60 80 100
I/Ir

t [s]

1230DIA-102 (70C1295)

0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 1230DIA-104 (70C1296) 20 30 40 50 60 80 100 70 90

0.01

200

300 400

600 800 1000


kA

Indrumari de proiectare Curbe de declansare IZM26


IZM26A(V)(U)(P)...
IZM26V(U)... Curbe de declansare pentru protectie universala si selectiva Protectie la suprasarcina (L) si protectie la scurt-circuit cu temporizare scurta (S) Vezi indicatiile 1, 3, 4, 6, 7, 8, 9, 10. Protectie L: Caracteristica It ; Protectie S: caracteristica palier Protectie S: Caracteristica It
10000 9000 8000 2 h 7000 6000 5000 1 h 4000 3000 2000

73

t [s]

0.4 - 1 x In = Ir ( 0.4, 0.5, 0.6, 0.7, 0.8, 0.9, 1.0)

1000 900 800 700 600 500 400 300 200

1 min

100 90 80 70 60 50 40 30 20

C
24

15

10 9 8 7 6 5 4 3 2

D
Isd = 6 x Ir (2, 4, 7, 10, 12, 15, 20, 24 s + 0/- 30 )
7

H
5 4 t [s] 3 2

1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2

I h b c d f j
0.5 0.4 0.3 0.2 2 - 10 x Ir g5

1 0.9 0.8 0.7 0.6 0.5 0.4 0.3

0.5 0.3 0.1 , 0.3 , 0.5 s 0.1

J
(0.1 - 0.5 s)

0.2

0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 1230DIA-105 (70C1006) 0.5 0.7 0.9 0.6 0.8 1 2 3 4 5 6 7 8 9 10

0.1

0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 1230DIA-106 (70C1006)

0.01

20

30 40 50 60
I/Ir

100

0.01

4 5 6 7 8 9 10

20

30 40 50 60 80 100
I/Ir

74

Indrumari de proiectare Curbe de declansare IZM26


IZM26A(V)(U)(P)...
IZM26V(U)... Curbe de declansare pentru protectie universala si selectiva Protectie la scurt-circuit instantanee (I) Vezi indicatiile 4, 5, 6, 7, 11, 12. Protectie I: reglabila Protectie I: la declansare instantanee pentru curenti mari de scurt-circuit
10 9 8 7 6 5 4 3 2

2 - 10 x In g 10

t [s]

f h

1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2

0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 1230DIA-107 (70C1007) 0.5 0.7 0.9 0.6 0.8 1 2 3 4 5 6 7 8 9 10 20 30 40 50 60 80 100
I/In

0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 1230DIA-108 (70C1007) 20 30 40 50 60 80 100 70 90 200

t [s]

N
300 400 600 800 1000
IRMS kA

0.01

0.01

IZM26V(U)... Optional protectie la defecte cu pamantul +IZM-DTV(U)-E Vezi indicatiile 4, 6, 13, 14, 15, 16, 17. G: protectie la defecte cu pamantul, caracteristica palier G: protectie la defecte cu pamantul, caracteristica It
20
t [s]

10 9 8 7 6 5 4 3 2

0.5 0.25 1.0

0.25 - 1.0 x In g 10

5 4

t [s]

3 2 0.3 0.4 0.6

1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.35

0.75 0.5
0.5 0.4 0.3 0.2 0.1 - 0.5 s

1 0.9 0.8 0.7 0.6 0.5 0.4

0.25 0.5 0.3

0.3 0.2

0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 1230DIA-109 (70C1008) 0.01 0.2 0.05 0.07 0.09 0.06 0.08 0.1

0.1

0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02

0.1

0.3 0.4 0.5 0.7 0.9 0.6 0.8 1

5 6 7 89
I/In

0.01

1230DIA-110 (70C1008) 0.2 0.3 0.4 0.5 0.7 0.9 0.6 0.8 1 2 3 4 5 6 7 8 910
I/In

Indrumari de proiectare Curbe de declansare IZM26


IZM26A(V)(U)(P)...
IZM26U... Optional modul +IZM-DTU-ARMS Vezi indicatiile 4, 6, 12, 18, 19, 20, 21. Modul ARMS
10 9 8 7 6 5 4 3 2 R5 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 R2 R4 R1 R3

75

t [s]

0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 1230DIA-111 (70C1446) 0.5 0.7 0.9 0.6 0.8 1 2 3 4 5 6 7 8 9 10 20 30 40 50 60 80 100
I/In

0.01

76

Indrumari de proiectare Curbe de declansare IZM26


IZM26A(V)(U)(P)...
IZM26P... Curbe de declansare pentru protectia universala cu masura Protectie la suprasarcina (L) si protectie la scurt circuit cu temporizare scurta (S) Protectie L: Caracteristica It; Protectie S: caracateristica palier Vezi indicatiile 1, 3, 7, 9, 22, 23, 24, 25, 26.
10000 9000 8000 2 h 7000 6000 5000 1 h 4000 3000 2000

Protectie S: Caracteristica It Vezi indicatiile 1, 3, 7, 9, 22, 23, 24, 25, 26.

t [s]

A 0.4 - 1.0 x In = Ir (0.40, 0.45, 0.50, ..., 0.90, 0.95, 1.00)

1000 900 800 700 600 500 400 300 200

1 min

100 90 80 70 60 50 40 30 20

B
24 Isd = 6 x Ir 2 - 24 s g 30 (2.0, 2.5, 3.0, ..., 23.0, 23.5, 24.0)

10 9 8 7 6 5 4 3 2

10

D
1.5 - 10 x Ir (1.5, 2.0, 2.5, ..., 9.0, 9.5, 10.0), 12/14 x Ir

10 9 8 7 6 5 4 3 2

1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2

0.1 - 0.5 s (0.10, 0.15, 0.20, ..., 0.40, 0.45, 0.50) 0.50

t [s]

1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2

H
0.50

0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 1230DIA-112 (70C1034) 0.5 0.7 0.9 0.6 0.8 1 2 3 4 5 6 7 8 9 10 20 30 40 50 6070
I/Ir

0.1 0.09 0.08 0.07 0.06 0.05 0.04

I
0.1 - 0.5 s (0.10, 0.15, 0.20, ..., 0.40, 0.45, 0.50)

0.10

0.03 0.02 1230DIA-113 (70C1034) 2 3 4 5 6 7 8 9 10 20

0.01

0.01

30 40 50 60 80 100
I/Ir

Indrumari de proiectare Curbe de declansare IZM26


IZM26A(V)(U)(P)...
Protectie L: Caracteristica I4t; Protectie S: caracteristica palier Vezi indicatiile 1, 3, 7, 9, 22, 23, 24, 25, 27.
10000 9000 8000 2 h 7000 6000 5000 4000 1h 3000 2000

77

Protectie L: moderat inversa conf. IEEE; Protectie S: caracteristica palier Vezi indicatiile 3, 7, 8, 9, 23, 25, 28, 29, 30.

t [s]

A 0.4 - 1.0 x In = Ir (0.40, 0.45, 0.50, ..., 0.90, 0.95, 1.00)

1000 900 800 700 600 500 400 300 200

1 min

100 90 80 70 60 50 40 30 20

100 90 80 70 1 min 60 50 40 30 20

t [s]

L 0.4 - 1.0 x In = Ir (0.40, 0.45, 0.50, ..., 0.90, 0.95, 1.00)

M
0.1 - 5.0 (0.1, 0.2, 0.3, ..., 4.8, 4.9, 5.0)

10 9 8 7 6 5 4 3 2

K
5 Isd = 6 x Ir 1 - 5 s + 10/- 40 (1.0, 1.5, 2.0, ..., 4.0, 4.5, 5.0)

10 9 8 7 6 5 4 3 2

5.00 4.50 4.00 3.50 3.00 2.50 2.00 1.50

1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2

D
1.5 - 10 x Ir (1.5, 2.0, 2.5, ..., 9.0, 9.5, 10.0), 12/14 x Ir

0.50

1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2

1.00 0.80 0.60 0.50 0.40 0.30

0.1 - 0.5 s (0.10, 0.15, 0.20, ..., 0.40, 0.45, 0.50) 0.50

D
1.5 - 10 x Ir (1.5, 2.0, 2.5, ..., 9.0, 9.5, 10.0), 12/14 x Ir

0.20

0.10

0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 1230DIA-114 (70C1035) 0.5 0.7 0.9 0.6 0.8 1 2 3 4 5 6 7 8 9 10 20 30 40 50 60 80 100
I/Ir

0.1 0.09 0.08 0.07 0.06 0.05 0.04

0.10

0.03 0.02 1230DIA-115 (70C1038) 0.5 0.7 0.9 0.6 0.8 1 2 3 4 5 6 7 8 9 10

0.01

0.01

20

30 40 50 60 80 100
I/Ir

78

Indrumari de proiectare Curbe de declansare IZM26


IZM26A(V)(U)(P)...
Protectie L: moderat inversa conf. IEEE; Protectie S: caracteristica palier Vezi indicatiile 3, 7, 8, 9, 23, 25, 28, 30, 31.
500 400

Protectie L: moderat inversa conf. IEEE; Protectie S: caracteristica palier Vezi indicatiile 3, 7, 8, 9, 23, 25, 28, 30, 32.
500 400

t [s]

t [s]

300 200
0.4 - 1.0 x In = Ir (0.40, 0.45, 0.50, ..., 0.90, 0.95, 1.00)

300 200

L 0.4 - 1.0 x In = Ir (0.40, 0.45, 0.50, ..., 0.90, 0.95, 1.00)

1 min

100 90 80 70 60 50 40 30 20

1 min

100 90 80 70 60 50 40 30 20

N
10 9 8 7 6 5 4 3 2
0.2 - 5.0 (0.2, 0.3, 0.4, ..., 4.8, 4.9, 5.0)

10 9 8 7 6 5 4 3 2

N
0.2 - 5.0 (0.2, 0.3, 0.4, ..., 4.8, 4.9, 5.0)

5.00 4.50 4.00 3.50 3.00 2.50 2.00 1.50 1.00

1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2

0.1 - 0.5 s (0.10, 0.15, 0.20, ..., 0.40, 0.45, 0.50) 0.50

0.60 0.50 0.40 0.30 0.20

0.80

1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2

5.00 4.50 4.00 3.50 3.00 2.50 2.00 1.50 1.00 0.80 0.60

0.1 - 0.5 s (0.10, 0.15, 0.20, ..., 0.40, 0.45, 0.50) 0.50

0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02

D
1.5 - 10 x Ir (1.5, 2.0, 2.5, ..., 9.0, 9.5, 10.0), 12/14 x Ir

0.1 0.09 0.08 0.07 0.06 0.05 0.04

D
1.5 - 10 x Ir (1.5, 2.0, 2.5, ..., 9.0, 9.5, 10.0), 12/14 x Ir

0.50 0.40 0.30 0.20

0.03 0.02

0.01

1230DIA-116 (70C1039) 0.5 0.7 0.9 0.6 0.8 1 2 3 4 5 6 7 8 9 10 20 30 40 50 60 80 100


I/Ir

0.01

1230DIA-117 (70C1040) 0.5 0.7 0.9 0.6 0.8 1 2 3 4 5 6 7 8 9 10 20 30 40 50 60 80 100


I/Ir

Indrumari de proiectare Curbe de declansare IZM26


IZM26A(V)(U)(P)...
Protectie L: Standard inversa conf. IEC-A; Protectie S: caracteristica palier Vezi indicatiile 3, 7, 8, 9, 23, 25, 28, 30, 33.
100 90 80 70 1 min 60 50 40 30 20

79

Protectie L: Accentuat inversa conf. IEC-B; Protectie S: caracteristica palier Vezi indicatiile 3, 7, 8, 9, 23, 25, 28, 30, 34.
100 90 80 70 1 min 60 50 40 30 20

t [s]

L 0.4 - 1.0 x In = Ir (0.40, 0.45, 0.50, ..., 0.90, 0.95, 1.00)

t [s]

L 0.4 - 1.0 x In = Ir (0.40, 0.45, 0.50, ..., 0.90, 0.95, 1.00)

10 9 8 7 6 5 4 3 2

0.05 - 1.00 (0.05, 0.10, 0.15, ..., 0.90, 0.95, 1.00)

10 9 8 7 6 5 4 3 2

1.00 0.90 0.80 0.70 0.60 0.50 0.40

0.1 - 1.0 (0.10, 0.15, 0.20, ..., 0.90, 0.95, 1.00)

1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2

D
1.5 - 10 x Ir (1.5, 2.0, 2.5, ..., 9.0, 9.5, 10.0), 12/14 x Ir

0.30 0.20 0.15 0.10

0.1 - 0.5 s (0.10, 0.15, 0.20, ..., 0.40, 0.45, 0.50) 0.50

1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2

D
1.5 - 10 x Ir (1.5, 2.0, 2.5, ..., 9.0, 9.5, 10.0), 12/14 x Ir

1.00 0.90 0.80 0.70 0.60 0.50 0.40 0.30 0.20 0.15

0.1 - 0.5 s (0.10, 0.15, 0.20, ..., 0.40, 0.45, 0.50) 0.50

0.05

0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 1230DIA-123 (70C1031) 0.01 0.5 0.7 0.9 0.6 0.8 1 2 3 4 5 6 7 8 9 10 20 30 40 50 60 80 100
I/Ir

0.1 0.09 0.08 0.07 0.06 0.05 0.04

0.10

0.03 0.02 1230DIA-118 (70C1032) 0.5 0.7 0.9 0.6 0.8 1 2 3 4 5 6 7 8 9 10

0.01

20

30 40 50 60 80 100
I/Ir

80

Indrumari de proiectare Curbe de declansare IZM26


IZM26A(V)(U)(P)...
Protectie L: Extrem inversa conf. IEC-C; Protectie S: caracteristica palier Vezi indicatiile 3, 7, 8, 9, 23, 25, 28, 30, 35. IZM26P... Curbe de declansare pentru declansator cu masura Protectie la scurt-circuit instantanee (I) Vezi indicatiile 1, 4, 5, 6, 7, 11, 12. Protectie I: reglabila
10 9 8 7 6 5 4 3 2

500 400

t [s]

t [s]

300 200

L 0.4 - 1.0 x In = Ir (0.40, 0.45, 0.50, ..., 0.90, 0.95, 1.00)

1 min

100 90 80 70 60 50 40 30 20

2 - 10 x In g 10 (2.0, 2.5, 3.0, ..., 9.0, 9.5, 10.0)

1 0.9 0.8 0.7 0.6 0.5 0.4 0.3

10 9 8 7 6 5 4 3 2

0.2

P
0.15 - 1.00 (0.15, 0.20, 0.25, ..., 0.90, 0.95, 1.00)

1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2

1.00 0.90 0.80 0.70 0.60 0.50

0.1 - 0.5 s (0.10, 0.15, 0.20, ..., 0.40, 0.45, 0.50) 0.50

0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 1230DIA-124 (70C1043) 0.5 0.7 0.9 0.6 0.8 1 2 3 4 5 6 7 8 9 10 20 30 40 50 60
I/In

0.01

D
1.5 - 10 x Ir (1.5, 2.0, 2.5, ..., 9.0, 9.5, 10.0), 12/14 x Ir

0.40 0.30 0.20

Protectie I: la declansare instantanee pentru curent de scurt-circuit mari


0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02

0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02

AA

t [s]

0.01

1230DIA-119 (70C1033) 0.5 0.7 0.9 0.6 0.8 1 2 3 4 5 6 7 8 9 10 20 30 40 50 60 80 100


I/Ir

0.01

1230DIA-125 (70C1043) 20 30 40 50 60 80 100 70 90 200 300 400 600 800 1000


IRMS kA

Indrumari de proiectare Curbe de declansare IZM26


IZM26A(V)(U)(P)...
IZM26P... protectie la impamantare optionala +IZM-DTP-E Vezi indicatiile 4, 6, 13, 14, 15, 16, 25, 26, 36. G: Protectie la defecte cu pamantul, caracateristica palier
60 50 40 30 20

81

G: Protectie la defecte cu pamantul, caracteristica It


60 50 40 30 20

t [s]

t [s]

10 9 8 7 6 5 4 3 2

0.25 - 1.00 x In g 10 (0.25, 0,26, 0.27, ..., 0.98, 0.99, 1.00)

10 9 8 7 6 5 4 3 2

0.25 - 1.00 x In g 10 (0.25, 0,26, 0.27, ..., 0.98, 0.99, 1.00)

1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2

0.50

1 0.9 0.8 0.7 0.6 0.5 0.4 0.3

H
0.50

T
0.1 - 0.5 s (0.10, 0,15, 0.20, ..., 0.40, 0.45, 0.50 s)

0.2
0.10

0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 1230DIA-121 (70C1041) 0.05 0.07 0.09 0.06 0.08 0.1 0.2 0.3 0.4 0.5 0.7 0.9 0.6 0.8 1 2

0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02

W
0.1 - 0.5 s (0.10, 0,15, 0.20, ..., 0.40, 0.45, 0.50 s)

0.01

5 6 7 8 9 10
I/In

0.01

1230DIA-122 (70C1041) 0.2 0.3 0.4 0.6 0.8 1 0.5 0.7 0.9 2 3 4 5 6 7 8 9 10
I/In

IZM26P... Optional modul +IZM-DTP-ARMS Vezi indicatiile 4, 6, 12, 18, 19, 20, 21. Modul ARMS
10 9 8 7 6 5 4 3 2.5 2 4.0 8.0 6.0

t [s]

1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2

10.0

0.1 0.09 0.08 0.07 0.06 0.05 0.04 0.03 0.02 1230DIA-120 (70C1498) 0.5 0.7 0.9 0.6 0.8 1 2 3 4 5 6 7 8 9 10 20

0.01

30 40 50 60 80 100
I/In

82

Indrumari de proiectare Curbe de declansare IZM26


IZM26A(V)(U)(P)...
1 Declansatorul electronic are o memorie termica, care poate determina reducerea timpului de declansare la suprasarcina. Acest efect al memoriei termice apare daca un curent mai mare decat valoarea reglata pentru declansarea la suprasarcina apare pentru o anumita durata si este intrerupt printr-o declansare a unui dispozitiv din aval sau chiar a intreruptorului in cauza. La o suprasarcina ulterioara, intreruptorul va reactiona intr-un timp mai scurt decat normal. Valoarea cu care se reduce temporizarea este inversa fata de valoarea timpului scurs de la suprasarcina precedenta.Trebuie sa treaca aproximativ 5 minute pentru a se reseta complet memoria. 2 Activarea declansatoarelor de suprasarcina are loc la 110 % din Ir, cu o toleranta de 5 % (semnalizare prin LED-ul "Unit Status"). Caracteristicile sunt aplicabile pentru o temperatura ambianta cuprinsa intre -20 C si +55 C. O temperatura de peste +85 C va declansa automat intreruptorul si va fi semnalizata prin aprinderea LED-ului portocaliu. Intreruptorul trebuie sa corespunda valorilor de decalibrare din tabelul cu date tehnice. Punctul final al caracteristicii este determinat de aplicatie si de capacitatea de intrerupere a intreruptorului automat. Reglajul protectiei la scurtcircuit instantaneu are ca nivel de declansare valoarea conventionala 100 % 10 % . Timpul total de deschidere indicat include timpul de raspuns al declansatorului electronic, timpul de deschidere a intreruptorului si timpul de intrerupere a curentului. Setarile disponibile suplimentar "max M1": IZM20 M1 = 14 x In pentru curenti nominali de la 200 A pana la 1250 A M1 = 12 x In pentru curenti nominali de la 1600 A M1 = 10 x In pentru curenti nominali de la 2000 A IZM32, IZM40 M1 = 14 x In pentru curenti nominali de la 200 A pana la 1250 A M1 = 12 x In pentru curenti nominali de la 1600 A pana la 2500 A M1 = 10 x In pentru curenti nominali de la 3200 A pana la 4000 A IZM63 M1 = 14 x In pentru curenti nominali de la 2000 A pana la 2500 A M1 = 12 x In pentru curenti nominali de la 3200 A pana la 5000 A M1 = 10 x In pentru curenti nominali de la 6300 A 8 Activarea declansatoarelor de suprasarcina are loc la 110 % din Ir, cu o toleranta de 5 % (semnalizare prin LED-ul "Unit Status"). Activarea declansatorului de scurtcircuit cu temporizare scurta Isd se realizeaza la 100 % 5 % . Daca avem selectivitate zonala (ZSI) la declansatorul de scurt-circuit cu scurta temporizare si nu exista un semnal blocat, atunci timpul minim (0,10 s), se aplica indiferent de temporizarea tsd setata. 13 Setarile la defectele cu pamantul sunt activate la 100 % 10 % . 14 Cu exceptia notelor, tolerantele pe nivelele de curent sunt 10 % din valoarea aratata pe diagrama. 15 Defectele cu pamantul in combinatie cu functia ARMS sunt limitate la 1200 A. 16 Daca selectivitatea zonala (ZSI) este activata in cazul protectiei la defecte cu pamantul si nu exista un semnal blocat, atunci se aplica o valoare de timp minim (caracteristica palier ), indiferent de setari. 17 Punctul de intoarcere de la caracteristica It la caracteristica plata este indicata cu linie punctata si are loc la 0,625 x In . 18 Functia ARMS trebuie activata printr-un comutator sau prin comunicatii la distanta. Un LED albastru indica ca setarea functiei de testare este activa. 19 Timpii de deschidere sunt indicati in prezenta unei surse de curent auxiliar. 20 Declansarea determinata de functia ARMS este semnalizata de LED-ul INST. 21 Valorile de reducere nominale la activare cu o toleranta de 15 % sunt: 2,5 x In (= R5), 4 x In (= R4), 6 x In (= R3), 8 x In (= R2), 10 x In (= R1) 22 Aceasta caracteristica este prezentata ca multiplu al reglajului protectiei la suprasarcina Ir . Nivelul de activare este la 110 % din Ir , cu o toleranta de 5 %. Semnalizare cu LED "Unit Status". Ecuatia curbei de declansare dupa It este: timpul de declansare = temporizarea reglata tr x 36/I. Ecuatia curbei de declansare dupa I4t este: timpul de declansare = temporizarea reglata tr x 1296/ I4. Temporizarea declansarii la scurt-circuit si temporizarea la suprasarcina actioneaza independent. C urbele de suprasarcina sunt in continuare active chiar si dupa punctul de intersectie. 23 Pentru declansatoarele temporizate la scurt circuit Isd exista o setare "M1"care poate creste nivelul la care Isd este activ . 24 Activarea declansatoarelor temporizate la scurt circuit Isd are loc la 100 % 5 %. 25 Toleranta pentru temporizari in domeniul caracteristicii palier. Toleranta este +0/ -80 ms cu exceptia urmatoarelor valori reglate: la 0,10 s toleranta este de la 0,06 pana la 0,13 ms la 0,15 s toleranta este de la 0,10 pana la 0,17 ms la 0,20 s toleranta este de la 0,15 pana la 0,22 ms 26 Declansator de scurt circuit temporizat; caracteristica It Caracteristica It devine palier la valoarea 8 x Ir pentru caracteristica superioara iar timpul minim al curbei inferioare este cel corespunzator palierului. Ecuatia curbei superioare: Timp declansare = reglaj temporizare de scurta durata tsd x 64/I, Ecuatia curbei inferioare: Timp declansare = reglaj temporizare de scurta durata tsd x 64/I x 0,7, Ecuatiile de mai sus au toleranta +0/-30 % pentru toate setarile cu exceptia: Pentru 0,10 s este +30 %/-25 % Pentru 0,15 s este +20 %/-25 % Pentru 0,20 s este +10 %/-25 % Pentru toate caracteristicile, valoarea mai mica a timpului de raspuns la caracteristica palier, proiectat la linia It, va dermina un alt punct de revenire si o alta forma a caracteristicii.

10 Pentru curba It punctul de revenire la caracteristica plata este indicat prin linie punctata si are loc la 8 x Ir . 11 Intreruptoarele automate IZM20 si IZM32 sunt echipate intodeauna cu un declansator de scurt circuit instantaneu care se activeaza la o valoare efectiva de 18 x In (RMS) cu o toleranta de 15 %. Acesta functie de protectie este activa, chiar daca declansatorul de scurt circuit este dezactivat. 12 Aceste caracteristici sunt valabile pentru toate intreruptoarele automate IZM26. Timpul total de lichidare a defectului indicat trebuie considerat ca avand in vedere timpul maxim de raspuns al declansatorului, timpul de deschidere al intreruptorului automat si timpul de intrerupere a curentului in conditiile unor factori ce contribuie la inrautatirea conditiilor cum ar fi: tensiune maxima nominala, intreruperea unei faze si un factor minim de putere. Timpi mai rapizi de lichidare a defectului sunt posibili in functie de conditiile specifice din instalatii si tipul de intreruptor automat IZM26.

Indrumari de proiectare Curbe de declansare IZM26


IZM26A(V)(U)(P)...
27 In aceasta zona de temporizare F 0,5 s , functia de protectie la suprasarcina dupa I4t va deveni palier si nu va mai fi rapida decat tsd reglat, pentru a evita un salt in grafic. 28 Acesta curba este trasata ca multiplu de Ir . Reglajul temporizarii tr combinat cu nivelul de activare Isd si temporizarea tsd determina asa numitele caracteristici IEEE invers" si respectiv IEC invers. Declansarea instantanee Ii poate fi dezactivata (OFF). 29 Ecuatia caracteristicii: Timp de declansare = timp reglat tr x [0,0515/(I0,02 - 1) + 0,114], unde curentul la suprasarcina selectat I este multiplu de Ir . 30 Pentru fiecare curent > 1,2 x Ir toleranta este [ 15 %] sau[-15 %, +90 ms], care valoare este mai mare. Aceasta caracteristica devine palier la 14 x Ir in cazul unui tr mai scurt sau daca se suprapune cu curba de protectie la scurt-circuit temporizat. Temporizarea declansarii la scurt-circuit si temporizarea la suprasarcina actioneaza independent. C urbele de suprasarcina sunt in continuare active chiar si dupa punctul de intersectie. 31 Ecuatia caracteristicii: Timp de declansare = timp reglat tr x [19,61/(I - 1) + 0,491], unde curentul la suprasarcina selectat I este multiplu de Ir . 32 Ecuatia caracteristicii: Timp de declansare = timp reglat tr x [28,2/(I - 1) + 0,1217], unde curentul la suprasarcina selectat I este multiplu de Ir . 33 Ecuatia caracteristicii: Timp de declansare = timp reglat tr x [0,14/(I0,02 - 1)], unde curentul la suprasarcina selectat I este multiplu de Ir . 34 Ecuatia caracteristicii: Timp de declansare = timp reglat tr x [13,5/(I - 1)], unde curentul la suprasarcina selectat I este multiplu de Ir . 35 Ecuatia caracteristicii: Timp de declansare = timp reglat tr x [80/(I - 1)], unde curentul la suprasarcina selectat I este multiplu de Ir . 36 La declansatorul electronic Digitrip 1150 fara functia ARMS incepe reglarea protectiei la defecte cu pamantul la 0,1 x In. A B C D E F G Reglaj protectie la suprasarcina Timp total maxim de lichidare defect Timp total minim de lichidare defect Reglaj protectie la suprasarcina Reglaj protectie la scurt-circuit instantaneu Protectie la suprasarcina reglabila instantanee la curenti de scurt circuit mari Aplicatiile si valorile nominale capacitatii de rupere ale intreruptorului automat determina punctul final al curbei H Caracteristica declansatorului de suprasarcina se poate extinde pana la valoarea reglabila M1. I Reglaj temporizare protectie la scurtcircuit J Temporizare reglabila la caracteristica plana K Aplicatiile determina punctul final al curbei L Temporizare reglabila la caracteristica It M Protectia la scurtcircuit instantanee fixa N Punctul final al curbei O Reglaj la protectia la defecte cu pamantul P Reglaj la protectia la defecte cu pamantul cu temporizare la caracteristica plana Q Caracteristica plana pentru protectia la defecte cu pamantul cu temporizare R Caracteristica It pentru protectia la defecte cu pamantul cu temporizare S Reglaj la protectia la defecte cu pamantul cu temporizare la caracteristica It T Functia ARMS reglabila: R5 = reducere maxima R1 = reducere minima U Aplicatiile si valorile nominale ale capacitatii de rupere a intreruptorului automat determina punctul final al curbei V Punct de revenire W Reglaj temporizare protectie la defecte cu pamantul la caracteristica It X Reglaj temporizare Y Reglaj protectie la scurtcircuit instantanee Z Protectia la scurtcircuit instantanee fixa AA Protectia la scurtcircuit instantanee la curenti de scurtcircuit mari

83

84

Date tehnice Intreruptoare automate IZM26


IZM...
IZM20B08 Date generale Standarde si normative Temperatura ambianta Pozitia de montaj IZM20B10 IZM20B12 IZM20B16 IZM20B20 IZM20N08 IZM20N10

Date tehnice Intreruptoare automate IZM26


IZM...
IZM20N12 IZM20N16 IZM20N20

85

Depozitare In functionare (deschis)

C C

IEC/EN 60947 -40 - +70 (aparat cu afisaj LCD -20 - +70) -25 - +70 (aparat cu afisaj LCD -20 - +70)
30 30

IEC/EN 60947 -40 - +70 (aparat cu afisaj LCD -20 - +70) -25 - +70 (aparat cu afisaj LCD -20 - +70)
30 30

30 30

30 30

Categoria de utilizare Grad de protectie Directia de trecere a curentului in aparat Cai principale de curent Curent nominal = Curent nominal neintrerupt Curent nominal neintrerupt la 50 C1) Curent nominal neintrerupt la 60 C1) Curent nominal neintrerupt la 70 C1) Tensiune nominala de tinere la impuls Tensiune nominala de utilizare Utilizare in retele IT pana la U = 440 V Utilizare in retele IT pana la U = 690 V Categoria de supratensiune/Grad de poluare Tensiune nominala de izolare pana la 440 V 50/60 Hz pana la 690 V 50/60 Hz Curent nominal admisibil de scurta t=1s durata 50/60 Hz t=3s Capacitate nominala de deschidere la scurtcircuit Icn IEC/EN 60947 Ciclu pana la 240 V 50/60 Hz Icu O-t-CO pana la 440 V 50/60 Hz pana la 690 V 50/60 Hz pana la 1100 V 50/60 Hz IEC/EN 60947 Ciclu pana la 240 V 50/60 Hz Ics O-t-CO-t-CO pana la 440 V 50/60 Hz pana la 690 V 50/60 Hz pana la 1100 V 50/60 Hz Timpi de Timp total de deschidere comutare Timp de inchidere Timp de inchidere electrica (prin electromagnet de inchidere) Timp de deschidere electrica (prin declansator de deschidere/ de tensiune minima) Timp de deschidere prin declansator electronic (declansator de scurtcircuit fara temporizare) Durata de mecanica, fara intretinere viata mecanica, cu intretinere electrica, fara intretinere electrica, cu intretinere Frecventa maxima de comutare Puterea disipata la curentul nominal In la montaj fix incarcare trifazata simetrica debrosabil Greutate Montaj fix Montaj debrosabil 3-poli 4-poli 3-poli 4-poli
1) Curent

B IP20, IP54 cu capac de protectie oricare In = Iu Iu Iu Iu Uimp Ue IIT IIT Ui Icm Icm Icw Icw Icu Icu Icu Icu Ics Ics Ics Ics A A A A V c.a. V c.a. kA kA V kA kA kA kA kA kA kA kA kA kA kA kA ms ms ms ms ms Manevre Manevre Manevre Manevre Manevre/h W W kg kg kg kg 800 800 800 800 12000 690 21,5 III/3 1000 105,0 105,0 50 50 50 50 50 50 50 30 35 40 35/70 35 12500 20000 10000 10000 60 60 110 43,00 54,00 48,00 62,00 1000 1000 1000 1000 12000 690 21,5 III/3 1000 105,0 105,0 50 50 50 50 50 50 50 30 35 40 35/70 35 12500 20000 10000 10000 60 95 170 43,00 54,00 48,00 62,00 1250 1250 1100 1000 12000 690 21,5 III/3 1000 105,0 105,0 50 50 50 50 50 50 50 30 35 40 35/70 35 12500 20000 10000 10000 60 150 260 43,00 54,00 48,00 62,00

B IP20, IP54 cu capac de protectie oricare 1600 1600 1500 1350 12000 690 23,0 III/3 1000 105,0 105,0 50 50 50 50 50 50 50 30 35 40 35/70 35 12500 20000 10000 10000 60 240 420 43,00 54,00 48,00 62,00 2000 2000 1800 1650 12000 690 32,1 III/3 1000 105,0 105,0 50 30 50 50 50 50 50 50 30 35 40 35/70 35 10000 16000 8000 8000 60 280 560 43,00 54,00 48,00 62,00 800 800 800 800 12000 690 21,5 III/3 1000 136,5 136,5 65 40 65 65 65 65 65 65 30 35 40 35/70 35 12500 20000 10000 10000 60 45 90 43,00 54,00 48,00 62,00 1000 1000 1000 1000 12000 690 21,5 III/3 1000 136,5 136,5 65 40 65 65 65 65 65 65 30 35 40 35/70 35 12500 20000 10000 10000 60 70 140 43,00 54,00 48,00 62,00 1250 1250 1100 1000 12000 690 21,5 III/3 1000 136,5 136,5 65 40 65 65 65 65 65 65 30 35 40 35/70 35 12500 20000 10000 10000 60 110 220 43,00 54,00 48,00 62,00 1600 1600 1500 1350 12000 690 23,0 III/3 1000 136,5 136,5 65 40 65 65 65 65 65 65 30 35 40 35/70 35 12500 20000 10000 10000 60 180 360 43,00 54,00 48,00 62,00 2000 2000 1800 1650 12000 690 32,1 III/3 1000 136,5 136,5 65 40 65 65 65 65 65 65 30 35 40 35/70 35 10000 16000 8000 8000 60 280 560 43,00 54,00 48,00 62,00

Capacitati de rupere Capacitate nominala de inchidere la scurtcircuit

Indicatie

de durata admisibil pentru intreruptoare automate functionand in tablouri de distributiela diverse valori ale temperaturii ambiante din interior. Estimarea temperaturii din interiorul tabloului se face utilizand metodele de calcul din reglementarile CEI.

86

Date tehnice Intreruptoare automate IZM26


IZM...
IZM32B08 Date generale Standarde si normative Temperatura ambianta Pozitia de montaj IZM32B10 IZM32B12 IZM32B16 IZM32B20 IZM32B25 IZM32B32

Date tehnice Intreruptoare automate IZM26


IZM...
IZM32N08 IZM32N10 IZM32N12

87

Depozitare In functionare (deschis)

C C

IEC/EN 60947 -40 - +70 (aparat cu afisaj LCD -20 - +70) -25 - +70 (aparat cu afisaj LCD -20 - +70)
30 30

IEC/EN 60947 -40 - +70 (aparat cu afisaj LCD -20 - +70) -25 - +70 (aparat cu afisaj LCD -20 - +70)
30 30

30 30

30 30

Categoria de utilizare Grad de protectie Directia de trecere a curentului in aparat Cai principale de curent Curent nominal = Curent nominal neintrerupt Curent nominal neintrerupt la 50 C1) Curent nominal neintrerupt la 60 C1) Curent nominal neintrerupt la 70 C1) Tensiune nominala de tinere la impuls Tensiune nominala de utilizare Utilizare in retele IT pana la U = 440 V Utilizare in retele IT pana la U = 690 V Categoria de supratensiune/Grad de poluare Tensiune nominala de izolare pana la 440 V 50/60 Hz pana la 690 V 50/60 Hz Curent nominal admisibil de scurta t=1s durata 50/60 Hz t=3s Capacitate nominala de deschidere la scurtcircuit Icn IEC/EN 60947 Ciclu pana la 240 V 50/60 Hz Icu O-t-CO pana la 440 V 50/60 Hz pana la 690 V 50/60 Hz pana la 1100 V 50/60 Hz IEC/EN 60947 Ciclu pana la 240 V 50/60 Hz Ics O-t-CO-t-CO pana la 440 V 50/60 Hz pana la 690 V 50/60 Hz pana la 1100 V 50/60 Hz Timpi de Timp total de deschidere comutare Timp de inchidere Timp de inchidere electrica (prin electromagnet de inchidere) Timp de deschidere electrica (prin declansator de deschidere/ de tensiune minima) Timp de deschidere prin declansator electronic (declansator de scurtcircuit fara temporizare) Durata de mecanica, fara intretinere viata mecanica, cu intretinere electrica, fara intretinere electrica, cu intretinere Frecventa maxima de comutare Puterea disipata la curentul nominal In la montaj fix incarcare trifazata simetrica debrosabil Greutate Montaj fix Montaj debrosabil 3-poli 4-poli 3-poli 4-poli
1) Curent

B IP20, IP54 cu capac de protectie oricare In = Iu Iu Iu Iu Uimp Ue IIT IIT Ui Icm Icm Icw Icw Icu Icu Icu Icu Ics Ics Ics Ics A A A A V c.a. V c.a. kA kA V kA kA kA kA kA kA kA kA kA kA kA kA ms ms ms ms ms Manevre Manevre Manevre Manevre Manevre/h W W kg kg kg kg 800 800 800 800 12000 690 13,6 13,6 III/3 1000 136,5 136,5 65 65 65 65 65 65 65 30 35 40 35/70 35 12500 20000 10000 10000 60 40 85 58,00 72,00 70,00 88,00 1000 1000 1000 1000 12000 690 13,6 13,6 III/3 1000 136,5 136,5 65 65 65 65 65 65 65 30 35 40 35/70 35 12500 20000 10000 10000 60 60 130 58,00 72,00 70,00 88,00 1250 1250 1250 1250 12000 690 13,6 13,6 III/3 1000 136,5 136,5 65 65 65 65 65 65 65 30 35 40 35/70 35 12500 20000 10000 10000 60 90 200 58,00 72,00 70,00 88,00

B IP20, IP54 cu capac de protectie oricare 1600 1600 1600 1600 12000 690 23,5 23,5 III/3 1000 136,5 136,5 65 65 65 65 65 65 65 30 35 40 35/70 35 12500 20000 10000 10000 60 150 330 58,00 72,00 70,00 88,00 2000 2000 2000 2000 12000 690 28,9 28,9 III/3 1000 136,5 136,5 65 50 65 65 65 65 65 65 30 35 40 35/70 35 10000 16000 10000 10000 60 190 330 63,00 78,00 75,00 94,00 2500 2500 2500 2500 12000 690 39,6 39,6 III/3 1000 136,5 136,5 65 50 65 65 65 65 65 65 30 35 40 35/70 35 8000 12800 8000 8000 60 200 500 68,00 86,00 86,00 112,00 3200 3100 2800 2550 12000 690 39,6 39,6 III/3 1000 136,5 136,5 65 50 65 65 65 65 65 65 30 35 40 35/70 35 8000 12800 8000 8000 60 320 800 68,00 86,00 86,00 112,00 800 800 800 800 12000 690 13,6 13,6 III/3 1000 178,5 178,5 85 65 85 85 85 85 85 85 30 35 40 35/70 35 10000 16000 10000 10000 60 35 70 68,00 86,00 80,00 102,00 1000 1000 1000 1000 12000 690 13,6 13,6 III/3 1000 178,5 178,5 85 65 85 85 85 85 85 85 30 35 40 35/70 35 10000 16000 10000 10000 60 50 95 68,00 86,00 80,00 102,00 1250 1250 1250 1250 12000 690 13,6 13,6 III/3 1000 178,5 178,5 85 65 85 85 85 85 85 85 30 35 40 35/70 35 10000 16000 10000 10000 60 70 140 68,00 86,00 80,00 102,00

Capacitati de rupere Capacitate nominala de inchidere la scurtcircuit

Indicatie

de durata admisibil pentru intreruptoare automate functionand in tablouri de distributiela diverse valori ale temperaturii ambiante din interior. Estimarea temperaturii din interiorul tabloului se face utilizand metodele de calcul din reglementarile CEI.

88

Date tehnice Intreruptoare automate IZM26


IZM...
IZM32N16 Date generale Standarde si normative Temperatura ambianta Pozitia de montaj IZM32N20 IZM32N25 IZM32N32 IZM32H08 IZM32H10 IZM32H12

Date tehnice Intreruptoare automate IZM26


IZM...
IZM32H16 IZM32H20 IZM32H25

89

Depozitare In functionare (deschis)

C C

IEC/EN 60947 -40 - +70 (aparat cu afisaj LCD -20 - +70) -25 - +70 (aparat cu afisaj LCD -20 - +70)
30 30

IEC/EN 60947 -40 - +70 (aparat cu afisaj LCD -20 - +70) -25 - +70 (aparat cu afisaj LCD -20 - +70)
30 30

30 30

30 30

Categoria de utilizare Grad de protectie Directia de trecere a curentului in aparat Cai principale de curent Curent nominal = Curent nominal neintrerupt Curent nominal neintrerupt la 50 C1) Curent nominal neintrerupt la 60 C1) Curent nominal neintrerupt la 70 C1) Tensiune nominala de tinere la impuls Tensiune nominala de utilizare Utilizare in retele IT pana la U = 440 V Utilizare in retele IT pana la U = 690 V Categoria de supratensiune/Grad de poluare Tensiune nominala de izolare pana la 440 V 50/60 Hz pana la 690 V 50/60 Hz Curent nominal admisibil de scurta t=1s durata 50/60 Hz t=3s Capacitate nominala de deschidere la scurtcircuit Icn IEC/EN 60947 Ciclu pana la 240 V 50/60 Hz Icu O-t-CO pana la 440 V 50/60 Hz pana la 690 V 50/60 Hz pana la 1100 V 50/60 Hz IEC/EN 60947 Ciclu pana la 240 V 50/60 Hz Ics O-t-CO-t-CO pana la 440 V 50/60 Hz pana la 690 V 50/60 Hz pana la 1100 V 50/60 Hz Timpi de Timp total de deschidere comutare Timp de inchidere Timp de inchidere electrica (prin electromagnet de inchidere) Timp de deschidere electrica (prin declansator de/ deschidere/ de tensiune minima) Timp de deschidere prin declansator electronic (declansator de scurtcircuit fara temporizare) Durata de mecanica, fara intretinere viata mecanica, cu intretinere electrica, fara intretinere electrica, cu intretinere Frecventa maxima de comutare Puterea disipata la curentul nominal In la montaj fix incarcare trifazata simetrica debrosabil Greutate Montaj fix Montaj debrosabil 3-poli 4-poli 3-poli 4-poli
1) Curent

B IP20, IP54 cu capac de protectie oricare In = Iu Iu Iu Iu Uimp Ue IIT IIT Ui Icm Icm Icw Icw Icu Icu Icu Icu Ics Ics Ics Ics A A A A V c.a. V c.a. kA kA V kA kA kA kA kA kA kA kA kA kA kA kA ms ms ms ms ms Manevre Manevre Manevre Manevre Manevre/h W W kg kg kg kg 1600 1600 1600 1600 12000 690 23,5 23,5 III/3 1000 178,5 178,5 85 65 85 85 85 85 85 85 30 35 40 35/70 35 10000 16000 10000 10000 60 120 240 68,00 86,00 80,00 102,00 2000 2000 2000 2000 12000 690 28,9 28,9 III/3 1000 178,5 178,5 85 65 85 85 85 85 85 85 30 35 40 35/70 35 10000 16000 10000 10000 60 190 380 68,00 86,00 80,00 102,00 2500 2500 2500 2500 12000 690 39,6 39,6 III/3 1000 178,5 178,5 85 65 85 85 85 85 85 85 30 35 40 35/70 35 8000 12800 8000 8000 60 200 500 70,00 89,00 88,00 115,00

B IP20, IP54 cu capac de protectie oricare 3200 3100 2800 2550 12000 690 39,6 39,6 III/3 1000 178,5 178,5 85 65 85 85 85 85 85 85 30 35 40 35/70 35 8000 12800 8000 8000 60 320 800 70,00 89,00 88,00 115,00 800 800 800 800 12000 690 13,6 13,6 III/3 1000 210,0 178,5 85 65 100 100 85 100 100 85 30 35 40 35/70 35 10000 16000 10000 10000 60 30 60 68,00 86,00 80,00 102,00 1000 1000 1000 1000 12000 690 13,6 13,6 III/3 1000 210,0 178,5 85 65 100 100 85 100 100 85 30 35 40 35/70 35 10000 16000 10000 10000 60 50 95 68,00 86,00 80,00 102,00 1250 1250 1250 1250 12000 690 13,6 13,6 III/3 1000 210,0 178,5 85 65 100 100 85 100 100 85 30 35 40 35/70 35 10000 16000 10000 10000 60 70 140 68,00 86,00 80,00 102,00 1600 1600 1600 1600 12000 690 23,5 23,5 III/3 1000 210,0 178,5 85 65 100 100 85 100 100 85 30 35 40 35/70 35 10000 16000 10000 10000 60 120 240 68,00 86,00 80,00 102,00 2000 2000 2000 2000 12000 690 28,9 28,9 III/3 1000 210,0 178,5 85 65 100 100 85 100 100 85 30 35 40 35/70 35 10000 16000 10000 10000 60 190 380 68,00 86,00 80,00 102,00 2500 2500 2500 2500 12000 690 39,6 39,6 III/3 1000 210,0 178,5 85 65 100 100 85 100 100 85 30 35 40 35/70 35 8000 12800 8000 8000 60 200 500 70,00 89,00 88,00 115,00

Capacitati de rupere Capacitate nominala de inchidere la scurtcircuit

Indicatie

de durata admisibil pentru intreruptoare automate functionand in tablouri de distributiela diverse valori ale temperaturii ambiante din interior. Estimarea temperaturii din interiorul tabloului se face utilizand metodele de calcul din reglementarile CEI.

90

Date tehnice Intreruptoare automate IZM26


IZM...
IZM32H32 Date generale Standarde si normative Temperatura ambianta Pozitia de montaj IZM32S IZM40N40 IZM40H40 IZM63N40 IZM63N50 IZM63N63

Date tehnice Intreruptoare automate IZM26


IZM...
IZM63H40 IZM63H50 IZM63H63

91

Depozitare In functionare (deschis)

C C

IEC/EN 60947 -40 - +70 (aparat cu afisaj LCD -20 - +70) -25 - +70 (aparat cu afisaj LCD -20 - +70)
30 30

IEC/EN 60947 -40 - +70 (aparat cu afisaj LCD -20 - +70) -25 - +70 (aparat cu afisaj LCD -20 - +70)
30 30

30 30

30 30

Categoria de utilizare Grad de protectie Directia de trecere a curentului in aparat Cai principale de curent Curent nominal = Curent nominal neintrerupt Curent nominal neintrerupt la 50 C1) Curent nominal neintrerupt la 60 C1) Curent nominal neintrerupt la 70 C1) Tensiune nominala de tinere la impuls Tensiune nominala de utilizare Utilizare in retele IT pana la U = 440 V Utilizare in retele IT pana la U = 690 V Categoria de supratensiune/Grad de poluare Tensiune nominala de izolare pana la 440 V 50/60 Hz pana la 690 V 50/60 Hz Curent nominal admisibil de scurta t=1s durata 50/60 Hz t=3s Capacitate nominala de deschidere la scurtcircuit Icn IEC/EN 60947 Ciclu pana la 240 V 50/60 Hz Icu O-t-CO pana la 440 V 50/60 Hz pana la 690 V 50/60 Hz pana la 1100 V 50/60 Hz IEC/EN 60947 Ciclu pana la 240 V 50/60 Hz Ics O-t-CO-t-CO pana la 440 V 50/60 Hz pana la 690 V 50/60 Hz pana la 1100 V 50/60 Hz Timpi de Timp total de deschidere comutare Timp de inchidere Timp de inchidere electrica (prin electromagnet de inchidere) Timp de deschidere electrica (prin declansator de/ deschidere/ de tensiune minima) Timp de deschidere prin declansator electronic (declansator de scurtcircuit fara temporizare) Durata de mecanica, fara intretinere viata mecanica, cu intretinere electrica, fara intretinere electrica, cu intretinere Frecventa maxima de comutare Puterea disipata la curentul nominal In la montaj fix incarcare trifazata simetrica debrosabil Greutate Montaj fix Montaj debrosabil 3-poli 4-poli 3-poli 4-poli
1) Curent

B IP20, IP54 cu capac de protectie oricare In = Iu Iu Iu Iu Uimp Ue IIT IIT Ui Icm Icm Icw Icw Icu Icu Icu Icu Ics Ics Ics Ics A A A A V c.a. V c.a. kA kA V kA kA kA kA kA kA kA kA kA kA kA kA ms ms ms ms ms Manevre Manevre Manevre Manevre Manevre/h W W kg kg kg kg 3200 3100 2800 2550 12000 690 39,6 39,6 III/3 1000 210,0 178,5 85 65 100 100 85 100 100 85 30 35 40 35/70 35 8000 12800 8000 8000 60 320 800 70,00 89,00 88,00 115,00 3200 3100 2800 2550 12000 1100 39,6 III/3 1100 210,0 210,0 la cerere 25 25 30 35 40 35/70 35 8000 12800 8000 8000 60 320 800 70,00 89,00 88,00 115,00 4000 4000 4000 3776 12000 690 48,0 III/3 1000 178,5 136,5 85 65 85 85 65 85 85 65 30 35 40 35/70 35 5000 8000 3000 3000 60 560 1100 83,00 105,00 98,00 121,00

B IP20, IP54 cu capac de protectie oricare 4000 4000 4000 3776 12000 690 48,0 III/3 1000 210,0 136,5 100 65 100 100 65 100 100 65 30 35 40 35/70 35 5000 8000 3000 3000 60 560 1100 83,00 105,00 98,00 121,00 4000 4000 4000 4000 12000 690 III/3 1000 178,5 178,5 85 65 85 85 85 85 85 85 40 35 40 35/70 35 5000 8000 3000 3000 60 380 750 107,50 144,70 138,80 166,00 5000 5000 5000 5000 12000 690 III/3 1000 178,5 178,5 85 65 85 85 85 85 85 85 40 35 40 35/70 35 5000 8000 3000 3000 60 400 1000 125,20 163,30 157,40 200,00 6300 6200 5600 5100 12000 690 III/3 1000 178,5 178,5 85 65 85 85 85 85 85 85 40 35 40 35/70 35 5000 8000 3000 3000 60 620 1550 125,20 163,30 157,40 200,00 4000 4000 4000 4000 12000 690 III/3 1000 210,0 210,0 100 65 100 100 100 100 100 100 40 35 40 35/70 35 5000 8000 3000 3000 60 380 750 107,50 144,70 138,80 166,00 5000 5000 5000 5000 12000 690 III/3 1000 210,0 210,0 100 65 100 100 100 100 100 100 40 35 40 35/70 35 5000 8000 3000 3000 60 400 1000 125,20 163,30 157,40 200,00 6300 6200 5600 5100 12000 690 III/3 1000 210,0 210,0 100 65 100 100 100 100 100 100 40 35 40 35/70 35 5000 8000 3000 3000 60 620 1550 125,20 163,30 157,40 200,00

Capacitati de rupere Capacitate nominala de inchidere la scurtcircuit

Indicatie

de durata admisibil pentru intreruptoare automate functionand in tablouri de distributiela diverse valori ale temperaturii ambiante din interior. Estimarea temperaturii din interiorul tabloului se face utilizand metodele de calcul din reglementarile CEI.

92

Date tehnice Intreruptoare - separatoare IN26


IN...

Date tehnice Intreruptoare - separatoare IN26


IN...

93

IN20B08 Date generale Standarde si normative Temperatura ambianta Pozitia de montaj

IN20B10

IN20B12

IN20B16

IN20B20

IN20N08

IN20N10

IN20N12

IN20N16

IN20N20

Depozitare In functionare (deschis)

C C

IEC/EN 60947 -40 - +70 -25 - +70 (aparat cu afisaj LCD -20 - +70)
30 30

IEC/EN 60947 -40 - +70 -25 - +70


30 30

30 30

30 30

Categoria de utilizare Grad de protectie Directia de trecere a curentului in aparat Cai principale de curent Curent nominal = Curent nominal neintrerupt Curent nominal neintrerupt la 50 C1) Curent nominal neintrerupt la 60 C1) Curent nominal neintrerupt la 70 C1) Tensiune nominala de tinere la impuls Tensiune nominala de utilizare Utilizare in retele IT pana la U = 440 V Utilizare in retele IT pana la U = 690 V Categoria de supratensiune/Grad de poluare Tensiune nominala de izolare pana la 440 V 50/60 Hz pana la 690 V 50/60 Hz Curent nominal admisibil de scurta t=1s durata 50/60 Hz t=3s Timpi de Timp total de deschidere comutare Timp de inchidere Timp de inchidere electrica (prin electromagnet de inchidere) Timp de deschidere electrica (prin declansator de deschidere/ de tensiune minima) Durata de mecanica, fara intretinere viata mecanica, cu intretinere electrica, fara intretinere electrica, cu intretinere Frecventa maxima de comutare Puterea disipata la curentul nominal In la montaj fix incarcare trifazata simetrica debrosabil Greutate Montaj fix Montaj debrosabil Indicatie 3-poli 4-poli 3-poli 4-poli
1) Curent

B IP20, IP54 cu capac de protectie oricare In = Iu Iu Iu Iu Uimp Ue IIT IIT Ui Icm Icm Icw Icw A A A A V c.a. V c.a. kA kA V kA kA kA kA ms ms ms ms Manevre Manevre Manevre Manevre Manevre/h W W kg kg kg kg 800 800 800 800 12000 690 21,5 III/3 1000 105,0 105,0 50 30 35 40 35/70 12500 20000 10000 10000 60 60 110 43,00 54,00 48,00 62,00 1000 1000 1000 1000 12000 690 21,5 III/3 1000 105,0 105,0 50 30 35 40 35/70 12500 20000 10000 10000 60 95 170 43,00 54,00 48,00 62,00 1250 1250 1100 1000 12000 690 21,5 III/3 1000 105,0 105,0 50 30 35 40 35/70 12500 20000 10000 10000 60 150 260 43,00 54,00 48,00 62,00

B IP20, IP54 cu capac de protectie oricare 1600 1600 1500 1350 12000 690 23,0 III/3 1000 105,0 105,0 50 30 35 40 35/70 12500 20000 10000 10000 60 240 420 43,00 54,00 48,00 62,00 2000 2000 1800 1650 12000 690 32,1 III/3 1000 105,0 105,0 50 30 30 35 40 35/70 10000 16000 8000 8000 60 280 560 43,00 54,00 48,00 62,00 800 800 800 800 12000 690 21,5 III/3 1000 143,0 143,0 65 40 30 35 40 35/70 12500 20000 10000 10000 60 45 90 43,00 54,00 48,00 62,00 1000 1000 1000 1000 12000 690 21,5 III/3 1000 143,0 143,0 65 40 30 35 40 35/70 12500 20000 10000 10000 60 70 140 43,00 54,00 48,00 62,00 1250 1250 1100 1000 12000 690 21,5 III/3 1000 143,0 143,0 65 40 30 35 40 35/70 12500 20000 10000 10000 60 110 220 43,00 54,00 48,00 62,00 1600 1600 1500 1350 12000 690 23,0 III/3 1000 143,0 143,0 65 40 30 35 40 35/70 12500 20000 10000 10000 60 180 360 43,00 54,00 48,00 62,00 2000 2000 1800 1650 12000 690 32,1 III/3 1000 143,0 143,0 65 40 30 35 40 35/70 10000 16000 8000 8000 60 280 560 43,00 54,00 48,00 62,00

Capacitati de rupere Capacitate nominala de inchidere la scurtcircuit

de durata admisibil pentru intreruptoare automate functionand in tablouri de distributiela diverse valori ale temperaturii ambiante din interior. Estimarea temperaturii din interiorul tabloului se face utilizand metodele de calcul din reglementarile CEI.

94

Date tehnice Intreruptoare - separatoare IN26


IN...
IN32B08 Date generale Standarde si normative Temperatura ambianta Pozitia de montaj IN32B10 IN32B12 IN32B16 IN32B20 IN32B25 IN32B32

Date tehnice Intreruptoare - separatoare IN26


IN...

95

Depozitare In functionare (deschis)

C C

IEC/EN 60947 -40 - +70 -25 - +70


30 30

IEC/EN 60947 -40 - +70 -25 - +70


30 30
30 30

30 30

Categoria de utilizare Grad de protectie Directia de trecere a curentului in aparat Cai principale de curent Curent nominal = Curent nominal neintrerupt Curent nominal neintrerupt la 50 C1) Curent nominal neintrerupt la 60 C1) Curent nominal neintrerupt la 70 C1) Tensiune nominala de utilizare Utilizare in retele IT pana la U = 440 V Utilizare in retele IT pana la U = 690 V Categoria de supratensiune/Grad de poluare Tensiune nominala de izolare Cai principale de curent pana la 440 V 50/60 Hz pana la 690 V 50/60 Hz Curent nominal admisibil de scurta t=1s durata 50/60 Hz t=3s Timpi de Timp total de deschidere comutare Timp de inchidere Timp de inchidere electrica (prin electromagnet de inchidere) Timp de deschidere electrica (prin declansator de deschidere/ de tensiune minima) Durata de mecanica, fara intretinere viata mecanica, cu intretinere electrica, fara intretinere electrica, cu intretinere Frecventa maxima de comutare Puterea disipata la curentul nominal In la montaj fix incarcare trifazata simetrica debrosabil Greutate Montaj fix Montaj debrosabil Indicatie 3-poli 4-poli 3-poli 4-poli
1) Curent

B IP20, IP54 cu capac de protectie oricare In = Iu Iu Iu Iu Ue IIT IIT Ui A A A A V c.a. kA kA V 800 800 800 800 12000 690 13,6 13,6 III/3 1000 143,0 143,0 65 30 35 40 35/70 12500 20000 10000 10000 60 40 85 58,00 72,00 70,00 88,00 1000 1000 1000 1000 12000 690 13,6 13,6 III/3 1000 143,0 143,0 65 30 35 40 35/70 12500 20000 10000 10000 60 60 130 58,00 72,00 70,00 88,00 1250 1250 1250 1250 12000 690 13,6 13,6 III/3 1000 143,0 143,0 65 30 35 40 35/70 12500 20000 10000 10000 60 90 200 58,00 72,00 70,00 88,00

B IP20, IP54 cu capac de protectie oricare 1600 1600 1600 1600 12000 690 23,5 23,5 III/3 1000 143,0 143,0 65 30 35 40 35/70 12500 20000 10000 10000 60 150 330 58,00 72,00 70,00 88,00 2000 2000 2000 2000 12000 690 28,9 28,9 III/3 1000 143,0 143,0 65 50 30 35 40 35/70 10000 16000 10000 10000 60 190 330 63,00 78,00 75,00 94,00 2500 2500 2500 2500 12000 690 39,6 39,6 III/3 1000 143,0 143,0 65 50 30 35 40 35/70 8000 12800 8000 8000 60 200 500 68,00 86,00 86,00 112,00 3200 3100 2800 2550 12000 690 39,6 39,6 III/3 1000 143,0 143,0 65 50 30 35 40 35/70 8000 12800 8000 8000 60 320 800 68,00 86,00 86,00 112,00

Capacitati de rupere Capacitate nominala de inchidere la scurtcircuit

Icm Icm Icw Icw

kA kA kA kA ms ms ms ms

Manevre Manevre Manevre Manevre Manevre/h W W kg kg kg kg

de durata admisibil pentru intreruptoare automate functionand in tablouri de distributiela diverse valori ale temperaturii ambiante din interior. Estimarea temperaturii din interiorul tabloului se face utilizand metodele de calcul din reglementarile CEI.

96

Date tehnice Intreruptoare - separatoare IN26


IN...
IN32N08 Date generale Standarde si normative Temperatura ambianta Pozitia de montaj IN32N10 IN32N12 IN32N16 IN32N20 IN32N25 IN32N32

Date tehnice Intreruptoare - separatoare IN26


IN...
IN32S

97

Depozitare In functionare (deschis)

C C

IEC/EN 60947 -40 - +70 -25 - +70


30 30

IEC/EN 60947 -40 - +70 -25 - +70


30 30
30 30

30 30

Categoria de utilizare Grad de protectie Directia de trecere a curentului in aparat Cai principale de curent Curent nominal = Curent nominal neintrerupt Curent nominal neintrerupt la 50 C1) Curent nominal neintrerupt la 60 C1) Curent nominal neintrerupt la 70 C1) Tensiune nominala de tinere la impuls Tensiune nominala de utilizare Utilizare in retele IT pana la U = 440 V Utilizare in retele IT pana la U = 690 V Categoria de supratensiune/Grad de poluare Tensiune nominala de izolare pana la 440 V 50/60 Hz pana la 690 V 50/60 Hz Curent nominal admisibil de scurta t=1s durata 50/60 Hz t=3s Timpi de Timp total de deschidere comutare Timp de inchidere Timp de inchidere electrica (prin electromagnet de inchidere) Timp de deschidere electrica (prin declansator de deschidere/ de tensiune minima) Durata de mecanica, fara intretinere viata mecanica, cu intretinere electrica, fara intretinere electrica, cu intretinere Frecventa maxima de comutare Puterea disipata la curentul nominal In la montaj fix incarcare trifazata simetrica debrosabil Greutate Montaj fix Montaj debrosabil Indicatie 3-poli 4-poli 3-poli 4-poli
1) Curent

B IP20, IP54 cu capac de protectie oricare In = Iu Iu Iu Iu Uimp Ue IIT IIT Ui Icm Icm Icw Icw A A A A V c.a. V c.a. kA kA V kA kA kA kA ms ms ms ms Manevre Manevre Manevre Manevre Manevre/h W W kg kg kg kg 800 800 800 800 12000 690 13,6 13,6 III/3 1000 187,0 187,0 85 65 30 35 40 35/70 10000 16000 10000 10000 60 35 70 68,00 86,00 80,00 102,00 1000 1000 1000 1000 12000 690 13,6 13,6 III/3 1000 187,0 187,0 85 65 30 35 40 35/70 10000 16000 10000 10000 60 50 95 68,00 86,00 80,00 102,00 1250 1250 1250 1250 12000 690 13,6 13,6 III/3 1000 187,0 187,0 85 65 30 35 40 35/70 10000 16000 10000 10000 60 70 140 68,00 86,00 80,00 102,00

B IP20, IP54 cu capac de protectie oricare 1600 1600 1600 1600 12000 690 23,5 23,5 III/3 1000 187,0 187,0 85 65 30 35 40 35/70 10000 16000 10000 10000 60 120 240 68,00 86,00 80,00 102,00 2000 2000 2000 2000 12000 690 28,9 28,9 III/3 1000 187,0 187,0 85 65 30 35 40 35/70 10000 16000 10000 10000 60 190 380 68,00 86,00 80,00 102,00 2500 2500 2500 2500 12000 690 39,6 39,6 III/3 1000 187,0 187,0 85 65 30 35 40 35/70 8000 12800 8000 8000 60 200 500 70,00 89,00 88,00 115,00 3200 3100 2800 2550 12000 690 39,6 39,6 III/3 1000 187,0 187,0 85 65 30 35 40 35/70 8000 12800 8000 8000 60 320 800 70,00 89,00 88,00 115,00 3200 3100 2800 2550 12000 690 39,6 39,6 III/3 1100 52,5 52,5 auf Anfrage 30 35 40 35/70 8000 12800 8000 8000 60 320 800 70,00 89,00 88,00 115,00

Capacitati de rupere Capacitate nominala de inchidere la scurtcircuit

de durata admisibil pentru intreruptoare automate functionand in tablouri de distributiela diverse valori ale temperaturii ambiante din interior. Estimarea temperaturii din interiorul tabloului se face utilizand metodele de calcul din reglementarile CEI.

98

Date tehnice Intreruptoare - separatoare IN26


IN...
IN40N40 Date generale Standarde si normative Temperatura ambianta Pozitia de montaj IN40H40 IN63N40 IN63N50 IN63N63 IN63H40 IN63H50

Date tehnice Intreruptoare - separatoare IN26


IN...
IN63H63

99

Depozitare In functionare (deschis)

C C

IEC/EN 60947 -40 - +70 -25 - +70


30 30

IEC/EN 60947 -40 - +70 -25 - +70


30 30
30 30

30 30

Categoria de utilizare Grad de protectie Directia de trecere a curentului in aparat Cai principale de curent Curent nominal = Curent nominal neintrerupt Curent nominal neintrerupt la 50 C1) Curent nominal neintrerupt la 60 C1) Curent nominal neintrerupt la 70 C1) Tensiune nominala de tinere la impuls Tensiune nominala de utilizare Utilizare in retele IT pana la U = 440 V Utilizare in retele IT pana la U = 690 V Categoria de supratensiune/Grad de poluare Tensiune nominala de izolare pana la 440 V 50/60 Hz pana la 690 V 50/60 Hz Curent nominal admisibil de scurta t=1s durata 50/60 Hz t=3s Timpi de Timp total de deschidere comutare Timp de inchidere Timp de inchidere electrica (prin electromagnet de inchidere) Timp de deschidere electrica (prin declansator de deschidere/ de tensiune minima) Durata de mecanica, fara intretinere viata mecanica, cu intretinere electrica, fara intretinere electrica, cu intretinere Frecventa maxima de comutare Puterea disipata la curentul nominal In la montaj fix incarcare trifazata simetrica debrosabil Greutate Montaj fix Montaj debrosabil Indicatie 3-poli 4-poli 3-poli 4-poli
1) Curent

B IP20, IP54 cu capac de protectie oricare In = Iu Iu Iu Iu Uimp Ue IIT IIT Ui Icm Icm Icw Icw A A A A V c.a. V c.a. kA kA V kA kA kA kA ms ms ms ms Manevre Manevre Manevre Manevre Manevre/h W W kg kg kg kg 4000 4000 4000 3776 12000 690 48,0 III/3 1000 187,0 187,0 85 65 30 35 40 35/70 5000 8000 3000 3000 60 560 1100 83,00 105,00 98,00 121,00 4000 4000 4000 3776 12000 690 48,0 III/3 1000 220,0 220,0 100 65 30 35 40 35/70 5000 8000 3000 3000 60 560 1100 83,00 105,00 98,00 121,00 4000 4000 4000 4000 12000 690 III/3 1000 187,0 187,0 85 65 40 35 40 35/70 5000 8000 3000 3000 60 380 750 107,50 144,70 138,80 166,00

B IP20, IP54 cu capac de protectie oricare 5000 5000 5000 5000 12000 690 III/3 1000 187,0 187,0 85 65 40 35 40 35/70 5000 8000 3000 3000 60 400 1000 125,20 163,30 157,40 200,00 6300 6200 5600 5100 12000 690 III/3 1000 187,0 187,0 85 65 40 35 40 35/70 5000 8000 3000 3000 60 620 1550 125,20 163,30 157,40 200,00 4000 4000 4000 4000 12000 690 III/3 1000 220,0 220,0 100 65 40 35 40 35/70 5000 8000 3000 3000 60 380 750 107,50 144,70 138,80 166,00 5000 5000 5000 5000 12000 690 III/3 1000 220,0 220,0 100 65 40 35 40 35/70 5000 8000 3000 3000 60 400 1000 125,20 163,30 157,40 200,00 6300 6200 5600 5100 12000 690 III/3 1000 220,0 220,0 100 65 40 35 40 35/70 5000 8000 3000 3000 60 620 1550 125,20 163,30 157,40 200,00

Capacitati de rupere Capacitate nominala de inchidere la scurtcircuit

de durata admisibil pentru intreruptoare automate functionand in tablouri de distributiela diverse valori ale temperaturii ambiante din interior. Estimarea temperaturii din interiorul tabloului se face utilizand metodele de calcul din reglementarile CEI.

100

Date tehnice Accesorii pentru IZM26


IZM-AS, IZM-OTS, IZM-CS, IZM-S...
Contacte auxiliare, contacte semnalizare declansare si contacte semnalizare pozitie IZM-AS IZM-OTS IZM-CS

Capacitate nominala de rupere Sarcina inductiva 250 V c.a. 125 V c.c. 250 V c.c.

A A A

10 0,5 0,25

10 0,5 0,25

10 0,5 0,25

Declansatoare de deschidere IZM-ST24DC IZM-ST48DC IZM-STS24DC IZM-STS48DC Tensiune nominala de alimentare circuit de comanda c.a. 50/60 Hz Us V V c.c. Us Putere consumata c.a. c.c. Timp de reactie a intreruptorului automat la Us Domeniu de functionare Tensiune de dezexcitare Tensiune de atragere VA W ms

IZM-ST110AD IZM-STS110AD

IZM-ST230AD IZM-STS230AD

24 (atragere 250) 35

48 (atragere 250) 35

110 - 127 110 - 125 (atragere 450) (atragere 450) 35

208 - 240 220 - 250 (atragere 450) (atragere 450) 35

x Uc x Uc

Conform standard IEC

Electromagneti de inchidere IZM-SR24DC IZM-SR48DC Tensiune nominala de alimentare circuit de comanda c.a. 50/60 Hz Us V V c.c. Us Putere consumata c.a. c.c. Timp de reactie a intreruptorului automat la Us Domeniu de functionare Tensiune de dezexcitare Tensiune de atragere VA W ms

IZM-SR110AD

IZM-SR230AD

24 (atragere 250) 40

48 (atragere 250) 40

110 - 127 110 - 125 (atragere 450) (atragere 450) 40

208 - 240 220 - 250 (atragere 450) (atragere 450) 40

x Uc x Uc

Conform standard IEC

Date tehnice Accesorii pentru IZM26


IZM-UVR..., IZM-M...
Declansatoare de minima tensiune IZM-UVR24DC IZM-UVR32DC Tensiune nominala de alimentare circuit de comanda c.a. 50/60 Hz Us V V c.c. Us Putere consumata c.a. c.c. Timp de reactie a intreruptorului automat la Us Domeniu de functionare Tensiune de dezexcitare Tensiune de atragere VA W ms

101

IZM-UVR48DC

IZM-UVR110AC

IZM-UVR110DC

24 18 (atragere 250) 70

32 15 (atragere 275) 70

48 18 (atragere 275) 70

110 - 127 10 (atragere 450) 70

110 - 125 10 (atragere 450) 70

x Uc x Uc

Conform standard IEC Conform standard IEC

Declansatoare de minima tensiune IZM-UVR220DC IZM-UVR230AC Tensiune nominala de alimentare circuit de comanda c.a. 50/60 Hz Us V V c.c. Us Putere consumata c.a. c.c. Timp de reactie a intreruptorului automat la Us Domeniu de functionare Tensiune de dezexcitare Tensiune de atragere VA W ms

IZM-UVR400AC

IZM-UVR480AC

IZM-UVR600AC

220 - 250 10 (atragere 450) 70

208 - 240 10 (atragere 400) 70

380 - 415 10 (atragere 480) 70

480 10 (atragere 400) 70

600 10 (atragere 400) 70

x Uc x Uc

Conform standard IEC Conform standard IEC

Dispozitive de actionare cu motor IZM-M24DC IZM-M48DC IZM-M110DC Tensiune nominala de alimentare circuit de comanda c.a. 50/60 Hz Us V V c.c. Us Timpul necesar armarii resortului la 1 x Us Curent nominal Curent de pornire Putere consumata c.a. 50/60 Hz c.c. In s

IZM-M220DC

IZM-M110AC

IZM-M230AC

24 5

48 5

110 - 125 5

220 - 250 5

110 - 127 5

208 - 240 5

A A VA W

12 3 300 300

5 5 250 250

2 6 250 250

1 6 250 250

2 6 250 250

1 6 250 250

102

Dimensiuni Aparate de baza IZM26


IZM26, IN26

IN20, IZM20 Fixe IN20F, IZM20F


340 318 (3p), 413 (4p) 257 32 133 78

394

336 (3p), 431 (4p)

IN20, IZM20 Debrosabile IN20W, IZM20W


474 450 (3p), 585 (4p) 336 (3p), 431 (4p) 458 86

22

349

418

52

559

521

482

IN32, IZM32 Fixe IN32F, IZM32F


340 410 (3p), 537 (4p) 257 32 133 78

435

477

511 349 418

394

431 (3p), 558 (4p)

a Dimensiunea minima recomandata a carcasei (nu se mareste la scara)

Dimensiuni Aparate de baza IZM26


IZM26, IN26
IN32, IZM32 Debrosabile IN32W, IZM32W
474 432 (3p), 559 (4p)

103

458 129

559

521

482

435

559 (3p), 686 (4p)

434

IN40, IZM40 Fixe IN40F, IZM40F


340 133 633 (3p), 823 (4p) 32 78

394

635 653 (3p), 843 (4p)

IN40, IZM40 Debrosabile IN40W, IZM40W


474 667 (3p), 862 (4p) 316 458

349

418

400

431 86 52

521

482

907 (3p), 992 (4p)

a Dimensiunea minima recomandata a carcasei (nu se mareste la scara)

435

477

511

104

Dimensiuni Aparate de baza IZM26


IZM26, IN26

IN63, IZM63 Fixe IN63F, IZM63F


340 887 (3p), 1141 (4p) 257 32 133 78

394

907 (3p), 1161 (4p)

IN63, IZM63 Debrosabile IN63W, IZM63W


474 432

349

418 458 129

559

521

482

435

908 (3p), 1162 (4p) 1000 (3p), 1250 (4p)

434

a Dimensiunea minima recomandata a carcasei (nu se mareste la scara)

400

431

S-ar putea să vă placă și