-SDH Basics -Alcatel SDH Systems -Alcatel 1662SMC Introduction -SDH Link No.17
SDH Basics
What are SDH & PDH ? Advantages of SDH over PDH. SDH Data rates. SDH Multiplexing Structure. SDH Basic Frame Structure.
SDH Basics
Plesiochronous almost synchronous, because the digital signals being multiplexed together are not at quite the same frequency
SDH Basics
E4(139.264000Mbps)
SDH Basics
High Transmission Rates: The highest data rate that can be achieved with PDH technologies is 140 mbps, whereas the transmission rates up to 10Gbps (STM-64) can be achieved with SDH technology. Easy Add & Drop Functionality: Compared to the older PDH system, low bit rate channels can be easily extracted from and inserted into the high-speed bit streams in SDH. It is now no longer necessary to apply the complex and costly procedure of demultiplexing then remultiplexing the plesiosynchronous structure. High Availability and Capacity matching: With SDH, network providers can react quickly and easily to the requirements of their customers. For example, leased lines can be switched in a matter of minutes. The network provider can use standardized network elements (NE) that can be controlled and monitored from a central location via a telecommunications management network (TMN) system. Reliability:
Modern SDH networks include various automatic back-up circuit and repair mechanisms (like Automatic Protection Switching (APS) and Equipment Protection Switching (EPS) which are designed to cope with system faults and are monitored by management. As a result, failure of a link or an NE does not lead to failure of the entire network.
Integrated Services: SDH is the ideal platform for a wide range of services including POTS, ISDN,mobile radio, and data communications (LAN, WAN, etc.). It is also able to handle more recent services such as video on demand and digital video broadcasting via ATM.
Disadvantages of PDH
Changing from one hierarchical level to another requires additional equipment. For Add/drop of individual channels from the higher order stream we have to disassemble / reassemble it Redirection (cross-connection) of channels must be done by hand on DDFs. Administrative connections require separate equipment to support Supervision, EOW and protection switching. Compatibility of transmission and administrative signals between different vendor may give trouble.
SDH Basics
SDH Data rates: STM-0 (51.84 Mbps) STM-1 (155.52 Mbps) STM-4 (622.08 Mbps) STM-16 (2488.32 Mbps) STM-64 (9953.28 Mbps) STM-256 (39813.12 Mbps)
Note: The STM-0 is not widely used in the telecom network except for some Microwave Links.
SDH Basics
STM-N
xN
AUG
x1
AU-4
VC4
C4
x3
TUG-3 TU-3 VC3
E-4(139.264Mbps) Or ATM(149.760Mbps)
x7
STM-0 AU-3 VC3 C3
x1
TUG-2 Containers Virtual Containers (Containers + POH) Tributary Units/Administrative Units (Virtual Containers + Pointers) Tributary Unit Groups/Administrative Unit Groups (Multiplexed structures of lower signals) TU-2 VC2 C2
x3
TU-12 VC12 C12
x4
TU-11 VC11 C11
Alignment
Multiplexing
1.Container Cn, where C=Container,n=Index of the container(n=11,12,2,3,4) The rate of the container depends on the signal which is transported. 2.Virtual container VCn,It is made up of Cn and Poh Vcn=Cn+Poh,where Poh is path over head Pathover head contain Payload content 3.Tributary unit TUn=VCn+PTR n=11,12,2,3 lower oder VCn Where Pointer is an addittional rate used to locate its Vcn with in the TU 4.Tributary unit Group TUG-k=m*TU-n, where k=2,3 n=11,12,2,3 TUG ,the Tug-2/Tug-3 can consist of several types of capacity payloads with different sizes. 5.Adminitrative Unit(AU),it is made up of higher order VCn(n=3,4) and a pointer AUn=VCn+PTR n=3,4 AUG=1*AU-4 or 3*AU-3
SDH Basics
RSOH (3 x 9 Cells)
3 9 Rows 4 5
AU-4 POINTER
MSOH (4 x 9 Cells)
Each cell represents a single byte indicating a 64 kbps channel. RSOH :- Regenerator Section Overhead (27 bytes ) MSOH : Multiplexer Section Overhead (45 bytes) Total Section Overhead (SOH) : RSOH + MSOH AU-4 Pointer :- 9 bytes Payload :- 261 x 9 = 2349 bytes STM -1 Data rate = (270 x 9) bytes = 2430 bytes = 2430 x 64 kbps = 155520 kbps = 155.52 Mbps
SDH Basics
* *
B2
* *
B2
* *
SDH Basics
Overhead Byte
A1,A2 B1,B2 D1,D2,D3 D4,..,D12 E1,E2 F1 J0 K1,K2 S1 M1 Frame Alignment Quality Monitoring , parity bytes Qecc Network Management Qecc Network Management Voice Connections Maintenance Trace Identifier
Functions
Automatic Protection Switching (APS) Control Clock Quality Indicator Transmission Error Acknowledgement
1662SMC
1642
1660SM
Version 1(R1)
Version 2(R2)
Version 4(R4)
Version 5(R5)
It complies with the Synchronous Digital Hierarchy (SDH) defined in ITU-T Recommendation G.707. Compatible with existing plesiochronous systems as well as with the installed SDH networks, The 1662SMC is transmission equipment operating at 155.520 Mbit/s (STM-1) , 622.080 Mbit/s (STM-4) and 2488.320 Mbit/s(STM-16). It can be configured as a Multiple Line Terminal Multiplexers or as a Add/Drop Multiplexers or as a Mini local cross-connect for applications in linear links, network rings and meshed networks. Equipment (EPS) and network (MSP) protection mechanism Matrix capacity 96*96 stm-1 equivalent matrix(HO) 64*64 stm-1 equivalent matrix(LO) Network interfaces: Stm-1/4/16 Customer interfaces: 2Mbps,34/45Mbps,140Mbps,ethernet,gigaethernet
26km
49km
65km
PONDICHERRY
CUDDALORE
CHIDAMBARAM
KUMBAKONAM
TANJORE
50km 54km
TRICHY
Fiber allotted for vsnl/Ttsl : F no 39 F no 48 Fiber used for SDH Link name & no : F no 43&44 : SDH LINK No 17
Shelf View:
ACCESS AREA-1
PORT AREA
ACCESSAREA-2
- Total Slots : 20 - Access Area 1: Slot 1-5 ( Hosts Access Cards like A63E1, A4S1, Congi ,etc). - Access Area 2: Slot 16-20 ( Hosts Access Cards like A63E1, A4S1, Sergi ,etc). - Port(Basic area)Area: Slot 6-15 (Hosts Port Cards like SYNTH, P4S1, P63E1, etc).
1. Congi card : It the used to control the whole SDH system. It consists of power supply&house keeping unit. the congi card is in slot no1 2. Synth4Card: It is card used to insert the optical signals from the fms.It consists the Optical module it is named as IL- 4.2,IL-1.2,IS1.1.- these are called Optical modules. There are two synth cards its inserted in slot no 6&15. 3. P4S1N card: P indicates Port ,S1N indicates STM1. card 4. P63E1 card : P indicates port, 63 E1 indcates Electical signals. 5. A63E1-120 : its a card corresponding to P63E1 card.A indicates access area. 6. LSPORT/HSPROT: Its is a Low Speed/High speed protection Card. It is used to implement EPS protection.(i.e)it implements the connection between the access and spare card.These cards receive the signal coming from the access card via back panel.
7.SERGI CARD: Used as a stand by card for the CONGI CARD 8. IL- It indicates LONG HAL it should in corresponding SYNTH CARD. 9. IS- It indicates SHORT HAL . Note: 1. For All cards corresponding stand by cards are used. 2. Inserting a port card we have to insert a corresponding acess card in the particular slot. : Corresponding Acess area 3. Port area Slot No-7 : No-2 Slot No-8 : No-3 Slot No-9 : No-4 Slot No-10 : No-5 Slot No-11 : No-16 Slot No-12 : No-17 Slot No-13 : No-18 Slot No-14 : No-19 4. Congi card in Slot no- 1 5. Sergi card in Slot no-20 6. Synth card in slot no:6,15
P63E1 processes 63 2Mbits/s signals whose accesses are on the relevant Access cards A21E1,A63E1 P4ES1N handles four electrical STM-1 Signals.All four accesses are on the relevant access card(A4ES1).It is one of the board that can be EPS protected. P3E3T3 Prt card is a bi-directional interface from/to three PDH streams at 34Mbits/s or at 45Mbits/s Switchable and the STM-4
(1) Multicolor LED: Red led . local unit alarm Green led . in service unit Orange led . unit in stand-by (EPS schema)
P4ES1N handles four electrical STM-1 signals.All the four accesses are on the Relevant Access card(A4ES1).It can be EPS protected. P4E4N it describes the same features of P4S1N. Two STM-1 electrical modules(Electricl or optical )can be hosted on the board. Two further STM-1 modules can be hosted on the Access card A2S1
LEGEND: (1) Channel #1 (N.B.) (2) Channel #2 (N.B.) (3) Bicolor LED: Red led . local unit alarm Green led . in service unit
ACRONYM CONGI
SLOTS 1, 20
1662SM-C houses two congi card(i.e)congi-A and congi-B CONGI-A hold the Equip MAC(media access control) address
LEGEND: (1) Power (2) Housekeeping and remote alarm (3) Rack lamp (not used in slot 20) (4) QMD Q2 (not used in slot 20) (5) I/O BNC Q3 10base2 (not used in slot 20) (6) RJ45 Q3 10baseT (not used in slot 20) (7) Bicolor LED: Red led . local unit alarm Green led . in service unit
ACRONYM SERGI
SLOTS 20
Sergi card Provides reduced combination of congi and service card functions It has Power interface,Auxillary interface,I/p o/p clock interface for NE synchronization
LEGEND: (1) Power (2) Auxiliary channels: 2 channels G.703 2 channels RS232 2 channels V.11 (3) Aux and Sync. 2Mbit/s J1 . 2MHz Input (T3) or 2Mbit/s Input (T6) J2 . 2Mbit/s Input channel J3 . 2MHz output (T4) or 2Mbit/s output (T5) J4 . 2Mbit/s output channel (4) Four wire telephone extersion point (RJ11) (5) Z1-Z4 EOW zone selection LEDs (N.B.1) (6) L1-L2 LEDs status for selective and multiple call (N.B.2) (7) Telephone jack (8) Line seizure Key (9) EOW zone selection Key (10) Reset command Key (11) Bicolor LED: Red led . local unit alarm Green led . in service unit
SYNTH16 6,15 SYNTH16 can be EPS 1+1 Protected Slot no:6 is main card Slot no:15 is spare card Synth16 card is equipped with two parts for modules 1*STM-16 signals can be processed by the SYNTH 16 card Synth 16 card performs several fns like shelf controller,Equip controller, Performance monitoring collection,remote inventory Synth 16 cards have a 96*96 stm-1 Matrix capacity. It is also called as Compact ADM16 Card
LEGEND (1) Reset command key (2) Channel #1 (N.B.) (3) Lamp test pushbutton (4) Personal Computer Connector (F interface) (5) Red LED . Urgent Alarm (Critical or Major) (6) Red LED . Not Urgent Alarm (Minor) (7) Yellow LED . Alarm storing (Attended) (8) Yellow LED . Abnormal condition (9) Yellow LED . Indicative Alarm (Warning) (10) Green LED . when on it means active unit when off it means standby unit (11) Bicolor LED: Red led . local unit alarm (INT) Green led . in service unit (12) Alarm storing pushbutton (Attended)
A63E1 is the access card for the P63E1 63*2Mbit/s Access card(A63E1)Provides the connections from backpanel to the external line and vice versa for the 63 PDH signals. Three different type of connectors available: A63E1/A:75 ohms unbalanced A63E1/B:120 ohms balanced A63E1/C:75 Ohms unbalanced with coax(3 slot wide) LEGEND (1) Channel #1-7 (2) Channel #8-14 (3) Channel #15-21 (4) Channel #22-28 (5) Channel #29-35 (6) Channel #36-42 (7) Channel #43-49 (8) Channel #50-56 (9) Channel #57-63
A2S1 is the access card for the P4S1N and P4E4N port cards. A2S1 can host upto 2modules(optical stm-1) in the front panel.
LEGEND (1) Channel #3 (N.B.) (2) Channel #4 (N.B.) (3) Bicolor LED: Red led . local unit alarm Green led . in service unit
A3E3 Provides 3*34Mbit/s accesses for the P3E3T3 A3T3 Provides 3*45Mbit/s accesses for the P3E3T3 For each P3E3T3 One A3E3,A3T3 is necessary
LEGEND (1) Channel #1 (2) Channel #2 (3) Channel #3 (4) Bicolor LED: Red led . local unit alarm Green led . in service unit
A4ES1 Provides 4 STM-1 Accesses for the P4ES1N. For each P4ES1N one A4ES1 is Necessary
LEGENDA (1) Channel #1 (2) Channel #2 (3) Channel #3 (4) Channel #4 (5) Bicolor LED: Red led . local unit alarm Green led . in service unit
S-1.1 S-Stands for short haul 1-stands for stm-1 1-stands for representing 1310nm L-1.1 L-Stands for Long haul 1-stands for stm-1 1-stands for representing 1310nm Module types: Stm-1 and stm-4 Optical module:SC-PC Type and Fc-Pc Type are available Stm-1 & stm-4 Optical modules are available and it physically different 140Mbit/s-STM-1 Electrical module.
LEGENDA (1) Multicolor LED: Red led . local unit alarm Orange led . temperature major than 55 C Green led . in service unit (2) Battery A connector (3) Battery B connector (4) Alarms connector for 1662SMC on the Left side of the Rack (5) Not used (6) Alarms connector for 1662SMC on the Right side of the Rack (6)
HWF
+ VBATT (male)
GND (female)
POWER
-VBATT (male)
The optical interfaces which have HAZARD LEVEL 3A (see Table A below ) carry the following hazard symbol label:
Caution : Invisible Laser Radiation may be present inside the optical interfaces carrying the above label ,hence NEVER directly view into the beam.Doing so may result in the permanent damage to the eyesight. UNIT/PORT STM.1 STM.1 STM.1 STM.4 STM.4 STM.4 STM.16 STM.16 STM.16 OPTICAL INTERFACE S.1.1 (short haul) L.1.1 (long haul) L.1.2 (long haul) S.4.1 (short haul) L.4.1 (long haul) L.4.2 (long haul) S.4.1 (short haul) L.4.1 (long haul) L.4.2 (long haul) HAZARD LEVEL 1 3A 3A 1 3A 3A 3A 3A 3A
CLASSIFICATION OF ALARMS
SEVERITY ALARMS SYNTHESIS 1.Critical Alarms 2.Major Alarms 3.Minor Alarms 4.Warning Alarms 5.Intermediate Alarms DOMAIN ALARMS SYNTHESIS 1.Synchronization Alarms 2.External points(House keeping Alarms) 3.Transmission Alarms 4.Equipment Alarms MANAGEMENT ALARMS SYNTHESIS 1.Supervision 2.Alignment 3.Local access 4.Operating system 5.Managed by Nm & RM 6.Abnormal condition
Power -48V DC, 6A MCB Rating used in the TRU unit is 16A The max current consumed by the Equipment is less than 4Amps A/C environment with temperature, humidity and dust control Fire safety by centralised monitoring and automatic operation of extinguisher
LCT access through Q interface for NMS access through the LAN card Tools: Power source, power meter, OTDR (Optical Time Domain Reflectometer) and OSA (Optical Spectrum Analyser)
P3E3
P3T3
P4S1E
P4E4
RS232 Pin Assignments (DB9 PC signal set) Pin 1 Received Line Signal Detector (Data Carrier Detect)
Pin 2 Received Data Pin 3 Transmit Data Pin 4 Data Terminal Ready Pin 5 Signal Ground Pin 6 Data Set Ready Pin 7 Request To Send Pin 8 Clear To Send Pin 9 Ring Indicator The connector on the PC has male pins, therefore the mating cable needs to terminate in a DB9/F (Female pin) connector
PROTECTION TYPES
EPS
Equipment Protection Switching
MSP
Multiplex Section Protection
1:1 1:N
EQUIPMENT 2
1.The 1+1 EPS Protection type means that one working equip is Protected by One Redundant Equip 2.The mode of 1+1 EPS Protection is Non Revertive.
LINE 2
EQUIPMENT 1
LINE N
EQUIPMENT N
EQUIPMENT P
1)1:N Type protection means that N working Pieces of equip are protected by just 1 Portecting Equivalent. 2)The mode of 1:N Eps protection is revertive.
MSP(Multiplex Section Protection) MSP(linear) is also called as APS(Automatic Protection Switching) NE-A NE-B
WORKING
TX
PROTECTION
1+1Protection
RX
1:1Protection
TX
LOW PRIORITY LINE WORKING
RX RX
TX TX TX
WORKING WORKING PROTECTION
RX RX
1:N Protection