Documente Academic
Documente Profesional
Documente Cultură
1 Introduction
This document describes step-by-step instructions for integration of a RBS 6000 series.
2 Objective
This document serves the purpose of describing the procedure related to the Commissioning and integration of a RBS 6000 series. This first version will concentrate on the RBS 6201, the indoor macro version.
3 Prerequisites
Complete RBS carry-in, installation, and check power system.
4.2 Software
The latest RBS Software Packages BP_CXP102083%10_R6T. Site specific .xml files. 1. xxxxxxSiteInstall (xxxxxx is the Identity of the eNodeB)
4.3 Hardware
Ethernet crossover RJ45 to RJ45 cable for RBS-Thin Client connection (Ethernet). Serial RS-232C, RJ45-Dsub9 cables for RBS-Thin Client connection.
5 Configuration
In this document the following notation is used for commands.
$ telogread This would mean that you should enter te <space key> log <space key> read and then press <enter key>. $ appears when you open a serial connection and press the return key. 5.1 Prepare for Integration. 5.2 Check Miscellaneous Equipment (i.e. TMA/RET) 5.3 No alarm on transmission equipment (If Applicable). 5.4 Cabling between the Thin Client and RBS: Ethernet connection is made from the laptop to LMB connector on the DUL interface on the RBS6201. 5.5 Connect serial cable to LMA connector on the DUL interface of the eNodeB RBS 6201 5.6 Thin Client IP Address Change (see section 7) 5.7 Check Serial Connection (HyperTerminal/Putty)
6.2 On the desktop, right-click the My Network Places (Network Neighbourhood in NT) icon. 6.3 From the submenu, select <Properties> The Network and Dialup Connections Window opens
Right click on the Local Area Connection icon and select <Properties> from the drop down menu. The "Local Area Connection Properties" window will open.
Select Internet Protocol (TCP/IP) and click on <Properties> The following window opens. Note: this is the default setting for PC, and it should be returned to this at the end of
the procedure.
NB! You can avoid this setting if your PC get routing info from eNB. Check this by open an MSDOS window (Run from Start menu on your PC and cmd). If you get the following routing information when writing the command ipconfig in the MS-DOS window, you can proceed without setting the IPv4 address:
Select 'Use the following IP address' in the TCP/IP properties window. Enter the IP address for the Laptop PC (thin client), and also enter the Subnet Mask as detailed above. Check that the 'Use the following DNS server address' is selected and that the address and subnet mask is blank. 6.7 Click <OK> close all the windows. 6.8 With some operating systems it may be required to restart the Laptop PC (thin client) to activate the new IP settings. The Laptop PC (thin client) is now configured.
1. Format the eNodeB, see procedure below. 2. Transfer over c2 and d disk of the Basic Package disk by disk using ftp. Basic Package CXP102083%10_R6T. NB! Dont format or delete other disks than c2 and d. Let other files or folders stay on RBS. See example in chapter below.
3. Do reload command on serial interface and the node should come up with basic 4.
5. configuration (CV) after a couple of minutes. Start up Element Manager by using the following address in the browser: http://169.254.1.10/em/index.html. Download the Client to your PC and Install it. When the Client is installed, start it form Programs -> EM-Application. You can either start RBS Element Manager or RBS Configuraion tool -> Integrate RBS. From EMAS click tools in the top tab menu line and choose Configuration tool (only one choice). In the GUI that opens, browse for the SiteInstall file. Omit all other files. Disable security. See example:
6.
7.
8.
9. When installing for Netcom Rollout do following settings in the Configuring files data window:
10. When you have stepped to the window for Product information (stepping by using the
next button), take a picture of the label of the RBS6201 located at the bottom and in the middle of the front of the cabinet. Than you can zoom to be able to read the numbers. See example below:
11. Now you can start the integration by clicking Start Integration. NB! The eNB will restart
after 25% of the configuration is done, NB! DONT HAVE ANY WIRELESS DEVICE ACTIVA ON YOUR PC DURING THE INTEGRATION! 12. Contact NOC at Telia Sundsvall and check if they have contact with the site and everything is OK.
7.3 Specify the customer provided password for access to the RBS node with the following commands in the serial window. Not Relevant at this time.
$ passwd $x $x $ reload
Click Apply and then OK to connect. 8.5 Set the path in the Local System window to point to the Basic Package being loaded: Example C:\ CXP102083%10_R6T\hard_disk, In the folder hard_disk 2 folders exist, they are c2 and d.
Confirm that the folder structure displayed on the left side and the right side are
the same c2 and d Disable log. Options General Uncheck Enable log. From the left display, select folder c2 and d, and press button in the middle of the display, a pop up window will appear Do you want to transfer the selected folders and their contents? click Yes, this will start the file transfer. This should only take about 5 to 10 minutes. After the transfer is complete check that the files shown in both windows are the same and then exit WS- FTP. 8.6 Perform a reload. $reload
From the New Connection dialogue box input a name i.e. Node B and select a icon then click the OK button
9.2 From the Connect To dialogue box select the serial port that will be used to connect to the Node B from the Connect using: drop down i.e. COM1 then click the OK button
9.3 From the COMx Properties window i.e. COM1 set the following values: Bits per second: 9600 Data Bits: 8 Parity: None Stop bits: 1 Flow control: None
After the values are enter click on OK hit the Enter key and you should receive a prompt 9.4 To save the settings select FileSave As
9.5 From the Save As dialogue box select Desktop, input the file name i.e. Node B and click the Save button.
9.6 The next time Hyper Terminal is required for the Node B configuration just double click the icon on the Desktop
NB! If you have RS232 port on your PC it is most likely defined as port COM1. If you are using USB port with connector converting to RS232, you need to check the interfaces on your PC to find out which port the serial interface is connected to. Write the command Ipconfig in the MSDOS window.
3.
4. When connected to 4G and with internet connection run from browser window: http://speedtest.net 4. Take a picture from the result (snipp or equal) and past into the sheet 2, 3 and 4 in the test report for each sector. Fill out page 1 of the test report with adequate information.