Thank you for purchasing DELTAs DOP-A, AE and AS series. This quick start will be helpful in the installation,
wiring and inspection of Delta HMI. Before using the product, please read this quick start to ensure correct use.
You should thoroughly understand all safety precautions before proceeding with the installation, wiring and
operation. Place this quick start in a safe location for future reference. Please observe the following
precautions:
Install the product in a clean and dry location free from corrosive and inflammable gases or liquids.
Ensure that all wiring instructions and recommendations are followed.
Ensure that HMI is correctly connected to a ground. The grounding method must comply with the
electrical standard of the country.
Do not modify or remove wiring when power is applied to HMI.
Do not touch the power supply during operation. Otherwise, it may cause electric shock.
For the information of HMI software operation, software installation and hardware wiring, please
refer to the HMI software manual.
If you have any questions during operation, please contact our local distributors or Delta sales representative.
The content of this quick start may be revised without prior notice. Please consult our distributors or download
the most updated version at http://www.delta.com.tw/industrialautomation.
0
Safety Precautions
Carefully note and observe the following safety precautions when receiving, inspecting, installing, operating,
maintaining and troubleshooting. The following words, DANGER, WARNING and STOP are used to mark
safety precautions when using the Deltas HMI product. Failure to observe these precautions may void the
warranty!
Installation
Comply with quick start for installation. Otherwise it may cause equipment damage.
Do not install the product in a location that is outside the stated specification for the HMI. Failure to
observe this caution may result in electric shock, fire, or personal injury.
Wiring
Connect the ground terminals to a class-3 ground (Ground resistance should not exceed 100).
Improper grounding may result in communication error, electric shock or fire.
Operation
The users should use Delta Screen Editor software to perform editing in Delta's HMI product. To
perform editing and confirming HMI programs without using Delta Screen Editor software in Delta's
HMI product may result in abnormal operation.
Do not modify wiring during operation. Otherwise it may result in electric shock or personal injury.
Never use a hard or pointed object to hit or strike the screen as doing this may damage the screen
and let the screen has not respond at all, and then cause HMI to work abnormally..
English-1
Wiring Method
Remove the terminal block from the HMI before wiring.
Insert only one wire into one terminal on the terminal block.
If the wiring is in error, perform the wiring again with proper tools. Never use force to remove the
terminals or wires. Otherwise, it may result in malfunction or damage.
For the power line that forced to take out, ensure to check wiring again and restart.
Communication Wiring
Comply with communication wiring specification for wiring.
Wiring length should comply with the stated specification for the HMI.
Proper grounding to avoid bad communication quality.
Installation
Installation Note:
Improper installation will result in malfunction and greatly reduce the life of the HMI. Be sure to
follow the guidelines in this quick start when installing the HMI.
In order to ensure the HMI being well ventilated, make sure that the ventilation holes are not
obstructed and must provide sufficient free space around HMI.
For use on a flat surface of a Type 4X "Indoor Use Only" enclosure or equivalent.
English-2
Step 2:
Step 3:
Turn the screw with less than torque 0.7N-M to avoid damage to plastic box. Torque: 6.17lb-inch(0.7N-M)
Step 2:
Step 3:
Turn the screw with less than torque 0.7N-M to avoid damage to plastic box. Torque: 6.17lb-inch(0.7N-M)
English-3
Stripped length
Torque
Solid
28~12
7~8 mm
Stranded
28~12
7~8 mm
The specifications for communication terminal wiring are shown in the table below (AS Series only):
Type
Stripped length
Torque
Solid
30 ~ 16
5 ~ 6 mm
Stranded
30 ~ 16
5 ~ 6 mm
Be sure to plug power line into HMI according to following arrow direction.
DOP-AS35THTD
DOP-AS38BSTD
DOP-A(E)57G(B)(C)STD
DOP-A80THTD1
DOP-AE80THTD
DOP-A(E)10THTD1
DOP-AS57BSTD
Basic Inspection
Item
Content
Periodically inspect the screws of the connection between the HMI and device.
Tighten screws as necessary as they may loosen due to vibration and varying
temperatures.
General Inspection
Ensure that oil, water, metallic particles or any foreign objects do not fall inside the
HMI, control panel or ventilation slots and holes. As these will cause damage.
Ensure the correct installation and the control panel. It should be free from
airborne dust, harmful gases or liquids.
English-4
Item
Content
Ensure that all wiring terminals are correctly insulated.
Ensure that all wiring is correct or damage and or malfunction may result.
Inspection before
operation (power is
not applied)
Visually check to ensure that there are not any unused screws, metal strips, any
conductive or inflammable materials inside HMI.
Ensure to lower electromagnetic interference when devices are influenced by it.
Ensure that the external applied voltage to HMI is correct and matched to the
controller.
Check if power LED lights.
Inspection before
operation (power is
applied)
Contact
RS-232
PIN
1
2
3
4
5
6
7
8
9
Pin
RXD
TXD
GND
RTS
CTS
Pin
PIN
1
2
3
4
5
6
7
8
9
MODE1
RS-232
RXD
TXD
RTS
CTS
MODE2
RS-422
RXDRXD+
TXD+
TXDGND
RTSRTS+
CTS+
CTS-
MODE3
RS-485
DD+
D+
D-
English-5
PIN
1
2
3
4
5
6
7
8
9
COM2
Pin
COM3
MODE1
RS-232
MODE2
RS-422
RXDRXD+
TXD+
TXD-
RXD
TXD
RTSRTS+
CTS+
CTS-
RTS
CTS
PIN
COM1
Pin
COM3
1
2
3
4
5
6
7
8
9
MODE1
RS-232
MODE2
RS-232*2
RXD
TXD
RXD1
TXD1
GND
RTS
CTS
TXD2
RXD2
PIN
R-
MODE1
RS-422
MODE2
RS-485
R-
RXD-
D-
R+
RXD+
D+
T-
TXD-
D-
T+
TXD+
D+
GND
Note 1: When selecting Mode2 (for RS-485), D+ indicates that R+ and T+ is connected, and Dindicates that R- and T- is connected.
English-6
COM2
PIN
COM2
COM3
COM3
RR+
TT+
G
RR+
TT+
MODE1
RS-485*2
DD+
DD+
MODE2
RS-422*2
RXDRXD+
TXDTXD+
GND
RXDRXD+
TXDTXD+
MODE3
RS-422
RXDRXD+
TXDTXD+
CTSCTS+
RTSRTS+
DOP-AE Series
DOP-A Series
DOP-AS57 Series
COM1
RS-232 flow
control
supported
COM2
RS-422 flow
control
supported
N/A
Note: For more detailed information regarding the pin definition for flow control, please refer to the pin
definition of serial communication of each series.
English-7
Dimensions
DOP-AS35THTD / DOP-AS38BSTD
4-R3
36.7
140.8
104.8
)
92.8 +10 (3.65+0.04
0
T
NOTE:
T=1.6mm(0.06in) ~
3.0mm(0.12in)
Units: mm
DOP-AS57BSTD
172.4 +10 (6.79+0.04
)
0
4-R3(0.12)
39.0(1.54) 6.1(0.24)
T
144.1(5.67)
)
132.4+10 (5.21 +0.04
0
184.1(7.25)
NOTE:
T=0.06in(1.6mm) ~
0.12in(3.0mm)
Units: mm
English-8
DOP-A(E)57G(B)(C)STD
172.4 +10 (6.79+0.04
0 )
4-R3(0.12)
39.0(1.54) 6.1(0.24)
T
144.1(5.67)
184.1(7.25)
NOTE:
T=1.6mm(0.06in) ~
3.0mm(0.12in)
Units: mm
DOP-A80THTD1 / DOP-AE80THTD
+0.04
231.4 +10 (9.11 0 )
R
4-
)
12
0.
0(
3.
6.1(0.24)
44.4 (1.75)
243.1(9.57)
+1
+0.04
0 (6.55 0 )
T
NOTE:
178.1(7.01)
166.4
T=1.6mm(0.06in) ~
3.0mm(0.12in)
Units: mm
DOP-A(E)10THTD1
285.2
+1
0
(11.22
+0.04
0 )
0(
3.
-R
12
0.
43.1(1.70) 6.1(0.24)
297.1(11.70)
NOTE:
T=1.6mm(0.06in) ~
3.0mm(0.12in)
222.1(8.74)
210.2
+1
+0.04
0 (8.27 0 )
Units: mm
English-9
Specifications
MODEL
AS35THTD
AS38BSTD
LCD MODULE
AS57B(C)STD
A(E)57BSTD
A(E)57GSTD
Operation System
MCU
Flash ROM
Flash ROM
2Mbytes
SDRAM
8Mbytes
Backup Memory
(Bytes)
SM Card
EXT.
Memory USB Host
(Ver 1.1)
128K
16Mbytes
128K
128K
3 (AE)
3 (AE)
RS-232
COM1
COM3
USB Client
COM2
3
3
Extension Interface
Serial
COM
Port
16Mbytes
A: 256K
AE: 512K
RS-422 / RS-485
RS-232
Function Key
Operation Voltage
Backup Battery
Buzzer
85dB
Perpetual Calendar
(RTC)
Built-in
Cooling Method
Safety Approval
(Waterproof for
front panel)
Operation Temp.
0C ~ 50C
English-10
MODEL
AS35THTD
AS38BSTD
A(E)57BSTD
A(E)57GSTD
Ambient Humidity
Vibration
Resistance
Dimensions
(W) x (H) x (D) mm
Panel Cutout
(W) x (H) mm
Weight
AS57B(C)STD
-20C ~ +60C
Storage Temp.
184.1 x 144.1 x 47
118.8 x 92.8
172.4 x 132.4
Approx. 315g
Approx. 310g
Approx. 760g
NOTE
1)
2)
3)
The half-life of backlight is defined as original luminance being reduced by 50% when the maximum driving current
o
is supplied to HMI. The life of LED backlight shown here is an estimated value under 25 C normal temperature and
humidity conditions.
Users please use isolated power supply except DOP-A80THTD1, DOP-AE80THTD and DOP-A(E)10THTD1 these
models.
Users can download the Screen Editor V1.05, the program editor of Delta HMI product and the user manual via the
following link: http://www.delta.com.tw/industrialautomation/.
The content of this quick start may be revised without prior notice. Please consult our distributors or download the
most updated version at http://www.delta.com.tw/industrialautomation/.
1
4)
English-11
A(E)57CSTD
Display Type
Resolution
LCD MODULE
MODEL
Back Light
Display Size
A80THTD1
AE80THTD
8 TFT LCD
(65536 colors)
162.2 x 121.7mm
Operation System
MCU
Flash ROM
A(E)10THTD1
SDRAM
16Mbytes
32Mbytes
32Mbytes
Backup Memory
(Bytes)
A: 256K
AE: 512K
512K
512K
SM Card
EXT.
USB
Host
Memory
(Ver 1.1)
3 (AE)
Extension Interface
3 (AE)
3 (AE)
COM2
Function Key
3 (AE)
RS-232
COM1
COM3
USB Client
Serial
COM
Port
RS-232 / RS-422 /
RS-485 (AE)
User defined key x 4 +
System key x 1
Operation Voltage
Backup Battery
Buzzer
85dB
Perpetual Calendar
(RTC)
Built-in
Cooling Method
Safety Approval
(Waterproof for
front panel)
Operation Temp.
0C ~ 50C
Storage Temp.
-20C ~ +60C
Ambient Humidity
English-12
A80THTD1
A(E)10THTD1
AE80THTD
IEC 61131-2 Compliant
5Hzf9Hz = Continuous: 1.75mm / Occasional: 3.5mm
9Hzf150Hz = Continuous: 0.5g / Occasional: 1.0g
X, Y, Z directions for 10 times
MODEL
A(E)57CSTD
Vibration
Resistance
Dimensions
(W) x (H) x (D) mm
Panel Cutout
(W) x (H) mm
184.1 x 144.1 x 47
172.4 x 132.4
231.4 x 166.4
285.2 x 210.2
Approx. 760g
Approx. 1140g
Approx. 1735g
Weight
NOTE
1)
2)
3)
The half-life of backlight is defined as original luminance being reduced by 50% when the maximum driving current
o
is supplied to HMI. The life of LED backlight shown here is an estimated value under 25 C normal temperature and
humidity conditions.
Users please use isolated power supply except DOP-A80THTD1, DOP-AE80THTD and DOP-A(E)10THTD1 these
models.
Users can download the Screen Editor V1.05, the program editor of Delta HMI product and the user manual via the
following link: http://www.delta.com.tw/industrialautomation/.
The content of this quick start may be revised without prior notice. Please consult our distributors or download the
most updated version at http://www.delta.com.tw/industrialautomation/.
3
4)
English-13
English-14
nsz
DELTAnn DOP-A, AE ve AS serisi operatr panellerini setiiniz iin teekkrler. Bu bilgi dkman Delta HMI
kurulum, balant, bakm ve kontrolnde kullancya yardmc olacaktr. Doru kullanm iin rn kullanmadan
nce bu dkman mutlaka okuyunuz. Kurulum, balant ve alma yapmadan nce gvenlik uyarlarn
tamamen anladnzdan emin olunuz. Bu dkman daha sonra da kullanmak iin iyi muhafaza ediniz. Ltfen
aadaki gvenlik uyarlarna dikkat ediniz:
rnn kurulumunu yanc gaz ve svlardan uzak kuru ve temiz ortamlara yapnz.
Balantlar yaparken tm balant kurallarnn salandndan emin olunuz.
HMInn toprak balantsnn doru yapldndan emin olunuz. Topraklama metodunun rnn
kurulduu lke standartlarna uygun olduuna emin olunuz.
HMI enerjili iken kablo balants yapmaynz ya da skmeyiniz.
alma srasnda power supply terminallerine dokunmaynz. Aksi halde elektrik oku olabilir.
HMI yazlmnn kurulumu, almas ve donanm balants ile ilgili daha fazla bilgi iin ltfen HMI
manualini inceleyiniz.
HMI ile ilgili sorularnz iin ltfen teknik servisimizle balantya geiniz.
Herhangi bir ihbara gerek kalmakszn bu bilgi dkmannn ierii deitirilebilir. Gncellenmi versiyonunu
elde etmek iin teknik servisimize danabilir yada http://www.delta.com.tw/industrialautomation adresinden
indirebilirsiniz.
Gvenlik Uyarlar
rn alrken, kontrol ederken, kurulumunu yaparken, altrrken, bakm ve arza tehisi yaparken aadaki
gvenlik uyarlarna dikkat ediniz. DANGER, WARNING, ve STOP balklar DELTA HMI rnn kullanrken
yaplmas gerekenleri dikkat ekmek iin kullanlmtr. rnn garantisini muhafaza etmek iin bu uyarlara
mutlaka dikkat ediniz!
Kurulum
Kurulumu dokman da belirtildii gibi yapnz. Aksi halde rn zarar grebilir.
Operatr panelini dokman da belirtilen ortam deerlerinin dnda kurulumunu yapmaynz. Aksi
halde elektrik oku, yangn ya da kiisel zararlara sebep olabilir.
Balant
Toprak terminallerini class-3 topraklama yapnz. (Topraklama direnci 100 u amamaldr). Yanl
yaplan topraklama balants haberleme hatasna, elektrik okuna ve yangna sebep olabilir.
alma
DELTAnn HMI rnlerini programlamak iin Delta Screen Editor yazlm kullanlmaldr. DELTA
HMI rnlerini programlamak iin Delta Screen Editor yazlm dnda bir yazlm kullanlmas
durumunda HMI almasnda problem meydana gelebilir.
alma srasnda kablo balantlarn deitirmeyiniz. Aksi halde elektrik okuna veya kiisel
zararlara sebep olabilir.
Dokunmatik ekrana sert ve sivri nesneler kullanarak basmaynz. Aksi halde HMI ekran zarar
grebilir ve HMInn anormal almasna sebep olabilir.
Trke-1
Bakm ve Kontroller
HMI iindeki devre elemanlarna dokunmaynz aksi halde elektrik oku meydana gelebilir.
Enerjili iken operatr panelinin balantlarna mdahale etmeyiniz. Aksi halde elektrik oku
meydana gelebilir.
HMI enerjisi kesildikten sonra HMI zerinde tehlikeli seviyede elektrik arj voltaj kalabileceinden
rne dokunmadan ve balantlara mdahale etmeden nce en az 10 dakika beklenilmesi tavsiye
edilir.
Pili deitirmeden nce rnn enerjisini kesiniz ve pili deitirdikten sonra sistem ayarlarn kontrol
ediniz. (Pil deitirildikten sonra tm datalar silinecektir).
alma srasnda havalandrma deliklerinin tkal olmadndan emin olunuz. Aksi halde kt
havalandrmadan veya ar scaklktan dolay rn zarar grebilir.
Balant Metodu
Kablo balants yapmadan nce terminal blounu HMIdan ayrnz.
Terminal bloundaki her bir terminale sadece tek bir kablo balaynz.
Eer balantda hata varsa, balanty uygun aletleri kullanarak tekrar yapnz. Terminal ya da
kablolar skmek iin darbe uygulamaynz. Aksi halde rn zarar grebilir.
Enerji hattnda bir kopukluk meydana gelmise, balantlarn salamln kontrol ettikten sonra
tekrar enerji verin.
Haberleme Balants
Haberleme balantsn dkman da belirtildii gibi yapnz.
HMI Kablo uzunluklar dkman da belirtildii gibi olmaldr.
Haberlemenin kalitesini arttrmak iin dzgn topraklama yapnz.
Kurulum
Kurulum Notlar:
Yanl kurulum yaplmas rnn zarar grmesini veya alma mrnn ksalmasna sebep olur.
HMI kurulumunun dokman da belirtildii gibi yaplmas gerekir.
HMInn havalandrmasnn doru olduuna emin olmak iin, havalandrma deliklerinin tkal
olmadna ve HMI etrafna gerekli boluun brakldna emin olunuz.
Dz yzey, Tip 4X Sadece kapal alanda kullanm ve edeer ortamlarda kurulum yaplmaldr.
Trke-2
Adm 2:
Adm 3:
Plastik kasaya zarar vermemek iin viday 0.7N.Mden az bir tork ile sknz. Tork: 6.17lb-inch(0.7N-M)
Adm 2:
Adm 3:
Plastik kasaya zarar vermemek iin viday 0.7N.Mden az bir tork ile sknz. Tork: 6.17lb-inch(0.7N-M)
Trke-3
Soyulacak uzunluk
Tork
Solid
28~12
7~8 mm
Stranded
28~12
7~8 mm
Soyulacak uzunluk
Tork
Solid
30 ~ 16
5 ~ 6 mm
Stranded
30 ~ 16
5 ~ 6 mm
DOP-A(E)57G(B)(C)STD
DOP-A80THTD1
DOP-AE80THTD
DOP-A(E)10THTD1
DOP-AS57BSTD
Temel Kontrol
Madde
erik
HMI balantlarn periyodik olarak kontrol ediniz. Titreim ve scaklk deiiminden
dolay geveyen vidalar sknz.
Genel Kontrol
HMI iine, kontrol paneline veya havalandrma slot ve deliklerine ya, su, metal
paralar veya yabanc nesnelerin dmediine emin olunuz. Bu durum rne zarar
verir.
Kurulumu doru yaptnza emin olunuz. Ortamda toz, zararl gaz ve svlar
olmamaldr.
Trke-4
Madde
erik
Tm balant terminallerinin doru izole olduundan emin olunuz.
almadan nce
kontrol (enerji
verilmeden nce)
altrmadan nce
kontrol (enerji
verildikten sonra)
Balant
RS-232
PIN
1
2
3
4
5
6
7
8
9
Pin
RXD
TXD
GND
RTS
CTS
Pin
PIN
1
2
3
4
5
6
7
8
9
MOD 1
RS-232
RXD
TXD
RTS
CTS
MOD 2
RS-422
RXDRXD+
TXD+
TXDGND
RTSRTS+
CTS+
CTS-
MOD 3
RS-485
DD+
D+
D-
Trke-5
PIN
COM2
Pin
COM3
1
2
3
4
5
6
7
8
9
MOD 1
RS-232
MOD 2
RS-422
RXDRXD+
TXD+
TXD-
RXD
TXD
RTSRTS+
CTS+
CTS-
RTS
CTS
MOD 3
MOD 4
MOD 5
MOD 6
RS-485 RS-232*2 RS-422*2 RS-485*2
DRXD1D1D+
RXD1
RXD1+
D1+
D+
TXD1
TXD1+
D1+
DTXD1D1GND
TXD2D2TXD2
TXD2+
D2+
RXD2
RXD2+
D2+
RXD2D2-
PIN
COM1
Pin
COM3
1
2
3
4
5
6
7
8
9
MOD 1
RS-232
MOD 2
RS-232*2
RXD
TXD
RXD1
TXD1
GND
RTS
CTS
TXD2
RXD2
PIN
R-
MOD 1
RS-422
MOD 2
RS-485
R-
RXD-
D-
R+
RXD+
D+
T-
TXD-
D-
T+
TXD+
D+
GND
Not 1: Mod 2 seildii zaman (RS-485 iin), D+ gsterilen yere R+ ve T+ terminallerinin balanacan
gsterir ve, D- ise R- ve T- terminallerinin balanacan gsterir.
Trke-6
COM2
PIN
RR+
TT+
G
RR+
TT+
COM2
COM3
COM3
MOD 1
RS-485*2
DD+
DD+
MOD 2
RS-422*2
RXDRXD+
TXDTXD+
GND
RXDRXD+
TXDTXD+
MOD 3
RS-422
RXDRXD+
TXDTXD+
CTSCTS+
RTSRTS+
DOP-AE Serisi
DOP-A Serisi
DOP-AS57 Serisi
COM1
RS232 flow
control destekler
RS-422 flow
RS422 flow control
RS-422 flow control
RS-422 flow control
control destekler
desteklemez.
destekler. Fakat,
destekler. Fakat,
RS-422 flow control
RS-422 flow control
RS-232 flow control
fonksiyonu aktif
fonksiyonu aktif edildii
destekler. Fakat, RS-232
edildii zaman, COM3
zaman, COM3
flow control fonksiyonu
COM3
N/A
kullanlamaz.
kullanlamaz.
aktif edildii zaman,
COM3 kullanlamaz.
COM2
Not: Flow control pin aklamalar ile ilgili daha detayl bilgi iin, ltfen her modelin seri haberleme pin
aklamasna baknz.
Trke-7
ller
DOP-AS35THTD / DOP-AS38BSTD
4-R3
36.7
140.8
104.8
)
92.8 +10 (3.65+0.04
0
T
NOTE:
T=1.6mm(0.06in) ~
3.0mm(0.12in)
Birim: mm
DOP-AS57BSTD
172.4 +10 (6.79+0.04
)
0
4-R3(0.12)
39.0(1.54) 6.1(0.24)
T
144.1(5.67)
)
132.4+10 (5.21 +0.04
0
184.1(7.25)
NOTE:
T=0.06in(1.6mm) ~
0.12in(3.0mm)
Birim: mm
Trke-8
DOP-A(E)57G(B)(C)STD
172.4 +10 (6.79+0.04
0 )
4-R3(0.12)
39.0(1.54) 6.1(0.24)
T
144.1(5.67)
184.1(7.25)
NOTE:
T=1.6mm(0.06in) ~
3.0mm(0.12in)
Birim: mm
DOP-A80THTD1 / DOP-AE80THTD
+0.04
231.4 +10 (9.11 0 )
R
4-
)
12
0.
0(
3.
6.1(0.24)
44.4 (1.75)
243.1(9.57)
+1
+0.04
0 (6.55 0 )
T
NOTE:
178.1(7.01)
166.4
T=1.6mm(0.06in) ~
3.0mm(0.12in)
Birim: mm
DOP-A(E)10THTD1
285.2
+1
0
(11.22
+0.04
0 )
0(
3.
-R
12
0.
43.1(1.70) 6.1(0.24)
297.1(11.70)
NOTE:
T=1.6mm(0.06in) ~
3.0mm(0.12in)
222.1(8.74)
210.2
+1
+0.04
0 (8.27 0 )
Birim: mm
Trke-9
zellikler
MODEL
LCD MODL
Display Tipi
AS35THTD
3.5 TFT LCD
(65536 renk)
AS38BSTD
AS57B(C)STD
znrlk
Arka Ik
Display l
A(E)57BSTD
(Not 1)
70.08 x
52.56mm
76.8 x 57.6mm
CCFL Arka Ik
o
letim Sistemi
MCU
Flash ROM
Flash ROM
2Mbyte
SDRAM
8Mbyte
Backup Memory
(Byte)
SM Card
EXT.
USB
Host
Memory
(Ver 1.1)
128K
16Mbyte
128K
128K
3 (AE)
3 (AE)
RS-232
COM1
COM3
USB Client
COM2
16Mbyte
A: 256K
AE: 512K
lave arabirim
Seri
COM
Port
A(E)57GSTD
RS-422 / RS-485
RS-232
Fonksiyon Tuu
alma Voltaj
Backup Battery
Buzzer
85dB
Gerek Zaman
Saati (RTC)
Dahili
Soutma Metodu
Gvenlik Onay
(Su geirmez n
panel)
alma Scakl
0C ~ 50C
Trke-10
MODEL
AS35THTD
AS38BSTD
Rutubet Oran
Titreim Direnci
ller
(W) x (H) x (D)
mm
Panel Kesim
(W) x (H) mm
Arlk
AS57B(C)STD
A(E)57BSTD
A(E)57GSTD
-20C ~ +60C
Saklama Scakl
184.1 x 144.1 x 47
118.8 x 92.8
172.4 x 132.4
Yaklak 315g
Yaklak 310g
Yaklak 760g
NOTE
1)
2)
3)
4)
Arka k yarm-mr, HMI maksimum akmla beslendiinde orijinal aydnlatmann %50 drld anlamna gelir.
Yukarda gsterilen arka k LED aydnlatma mr 25 derecede normal scaklk ve rutubet ortamnda tahmin edilen
deerlerdir.
DOP-A80THTD1, DOP-AE80THTD ve DOP-A(E)10THTD1 modelleri dnda ltfen izoleli g kayna kullannz.
Delta HMI Screen editor yazlmn ve user manuali aadaki linkten indirebilirsiniz:
http://www.delta.com.tw/industrialautomation/.
Herhangi bir ihbar olmadan bu dkmann ierii deitirilebilir. En son gncellenmi halini firmamzdan talep
edebilir yada aadaki link adresinden indirebilirsiniz
http://www.delta.com.tw/industrialautomation/.
Trke-11
LCD MODL
MODEL
A(E)57CSTD
Display Tipi
znrlk
Arka Ik
Display l
A80THTD1
AE80THTD
8 TFT LCD
(65536 renk)
162.2 x 121.7mm
letim Sistemi
MCU
Flash ROM
CCFL Arka Ik
o
(25 C yarm mrde 50,000 saatden az) (Not 1)
115.17 x 86.37mm
A(E)10THTD1
CCFL Arka Ik
o
(25 C yarm mrde
30,000 saatden az) (Not 1)
211.2 x 158.4mm
SDRAM
16Mbyte
32Mbyte
32Mbyte
Backup Memory
(Byte)
A: 256K
AE: 512K
512K
512K
SM Card
EXT.
USB
Host
Memory
(Ver 1.1)
3 (AE)
lave Arabirim
3 (AE)
3 (AE)
COM2
Fonksiyon Tuu
3 (AE)
RS-232
COM1
COM3
USB Client
Seri
COM
Port
RS-232 / RS-422 /
RS-485 (AE)
4 adet Kullanc tanml
tu + 1 adet Sistem tuu
alma Voltaj
Backup Battery
Buzzer
85dB
Gerek Zaman
Saati (RTC)
Dahili
Soutma Metodu
Gvenlik Onay
(Su geirmez n
panel)
alma Scakl
0C ~ 50C
Saklama Scakl
-20C ~ +60C
Rutubet Oran
Trke-12
MODEL
Titreim Direnci
ller
(W) x (H) x (D)
mm
Panel Kesim
(W) x (H) mm
Arlk
A80THTD1
A(E)10THTD1
AE80THTD
IEC 61131-2 Uyumlu
5Hzf9Hz = Srekli: 1.75mm / Geici: 3.5mm
9Hzf150Hz = Srekli: 0.5g / Geici: 1.0g
X, Y, Z ynlerinde 10 defa
A(E)57CSTD
184.1 x 144.1 x 47
172.4 x 132.4
231.4 x 166.4
285.2 x 210.2
Yaklak 760g
Yaklak 1140g
Yaklak 1735g
NOTE
1)
2)
3)
4)
Arka k yarm-mr, HMI maksimum akmla beslendiinde orijinal aydnlatmann %50 drld anlamna gelir.
Yukarda gsterilen arka k LED aydnlatma mr 25 derecede normal scaklk ve rutubet ortamnda tahmin
edilen deerlerdir.
DOP-A80THTD1, DOP-AE80THTD ve DOP-A(E)10THTD1 modelleri dnda ltfen izoleli g kayna kullannz.
Delta HMI Screen editor yazlmn ve user manuali aadaki linkten indirebilirsiniz:
http://www.delta.com.tw/industrialautomation/.
Herhangi bir ihbar olmadan bu dkmann ierii deitirilebilir. En son gncellenmi halini firmamzdan talep
edebilir yada aadaki link adresinden indirebilirsiniz
http://www.delta.com.tw/industrialautomation/.
Trke-13
Trke-14
DOP-AAEAS
NFPA 70:
National Electrical Code, 2005 Ed.
http://www.delta.com.tw/industrialautomation/
class-3100
10
-1
()
Type 4X
AAE
-2
0.7N-M
6.17lb-inch0.7N-M
AS
0.7N-M
6.17lb-inch0.7N-M
AWG
28 ~ 12
30 ~ 12
7 ~ 8 mm
7 ~ 8 mm
5 kg-cm4.3 lb-in
5 kg-cm4.3 lb-in
5 ~ 6 mm
5 ~ 6 mm
2 kg-cm1.7 lb-in
2 kg-cm1.7 lb-in
AS
AWG
30 ~ 16
30 ~ 16
-3
DOP-A(E)57G(B)(C)STD
DOP-AS35THTD
DOP-AS38BSTD
DOP-A80THTD1
DOP-AE80THTD
DOP-A(E)10THTD1
DOP-AS57BSTD
-4
COM1 AAEAS57BSTD
COM Port
RS-232
1
2
3
4
5
6
7
8
9
Pin
RXD
TXD
GND
RTS
CTS
COM2 A
COM Port
MODE1
RS-232
1
2
3
4
5
6
7
8
9
Pin
MODE2
RS-422
RXDRXD+
TXD+
TXDGND
RTSRTS+
CTS+
CTS-
RXD
TXD
RTS
CTS
MODE3
RS-485
DD+
D+
D-
1
2 Mode3 D+ Pin2Pin3 D- Pin1Pin4
COM2COM3 AEA80THTD1A10THTD1
COM Port
Pin
COM
Port
COM2
COM3
1
2
3
4
5
6
7
8
9
MODE1
RS-232
RXD
TXD
RTS
CTS
MODE2
RS-422
RXDRXD+
TXD+
TXDRTSRTS+
CTS+
CTS-
1
2 Mode3 D+ Pin2Pin3 D- Pin1Pin4
Mode6 D1+ Pin2Pin3 D1- Pin1Pin4 D2+ Pin7Pin8 D2 Pin6Pin9
-5
COM1COM3 AS38BSTDAS35THTD
COM Port
COM Port
1
2
3
4
5
6
7
8
9
COM1
Pin
COM3
MODE1
RS-232
MODE2
RS-232*2
RXD
TXD
RXD1
TXD1
GND
RTS
CTS
TXD2
RXD2
COM2 AS38BSTDAS35THTD
COM Port
R-
MODE1
RS-422
RXD-
MODE2
RS-485
D-
R+
RXD+
D+
T-
TXD-
D-
T+
TXD+
D+
R-
GND
COM2
COM Port
COM2
COM3
COM3
RR+
TT+
G
RR+
TT+
MODE1
RS-485*2
DD+
DD+
MODE2
RS-422*2
RXDRXD+
TXDTXD+
GND
RXDRXD+
TXDTXD+
MODE3
RS-422
RXDRXD+
TXDTXD+
CTSCTS+
RTSRTS+
1
2 RS-422 MODE3 COM2COM3
-6
COM
Port
DOP-AE
DOP-A
COM1 RS-232
RS-232
COM2
RS-422
RS-422
COM3
COM3
N/A
DOP-AS57
DOP-AS35AS38
RS-232
RS-232
COM3
RS-422
RS-422
COM3 RS-232
COM3
DOP-AS35THTDDOP-AS38BSTD
4-R3
36.7
140.8
104.8
)
92.8 +10 (3.65+0.04
0
T
NOTE:
T=1.6mm(0.06in) ~
3.0mm(0.12in)
mm
DOP-AS57BSTD
172.4 +10 (6.79+0.04
)
0
4-R3(0.12)
39.0(1.54) 6.1(0.24)
T
144.1(5.67)
)
132.4+10 (5.21 +0.04
0
184.1(7.25)
NOTE:
T=0.06in(1.6mm) ~
0.12in(3.0mm)
mm
-7
DOP-A(E)57G(B)(C)STD
172.4 +10 (6.79+0.04
0 )
4-R3(0.12)
39.0(1.54) 6.1(0.24)
T
144.1(5.67)
184.1(7.25)
NOTE:
T=1.6mm(0.06in) ~
3.0mm(0.12in)
mm
DOP-A80THTD1DOP-AE80THTD
+0.04
231.4 +10 (9.11 0 )
R
4-
)
12
0.
0(
.
3
6.1(0.24)
44.4 (1.75)
243.1(9.57)
+1
+0.04
0 (6.55 0 )
T
NOTE:
178.1(7.01)
166.4
T=1.6mm(0.06in) ~
3.0mm(0.12in)
mm
DOP-A(E)10THTD1
285.2
+1
0
(11.22
+0.04
0 )
0(
3.
-R
12
0.
43.1(1.70) 6.1(0.24)
297.1(11.70)
NOTE:
T=1.6mm(0.06in) ~
3.0mm(0.12in)
222.1(8.74)
210.2
+1
+0.04
0 (8.27 0 )
mm
-8
AS35THTD
AS38BSTD
AS57BSTD
76.8 x 57.6mm
115.17 x 86.37mm
ROM
Flash ROM
2Mbytes
8Mbytes
Bytes
SM Card
USB Host
Ver 1.1
128K
16Mbytes
128K
3AE
3AE
COM1
COM3
16Mbytes
A256K
AE512K
COM2
128K
USB Client
A(E)57GSTD
A(E)57BSTD
3.5 TFT LCD 3.8 STN LCD 5.7 STN LCD 5.7 STN LCD 5.7 FSTN LCD
65536 8 8 8 16
RS-232
RS-422RS-485
RS-232RS-422RS-485
RS-422
RS-485
RS-232
RS-232RS-422RS-485
AE
x 4 + x 1
DC +24V-10% ~ +15%(Note 2)
3V CR203215
85dB
IP65NEMA4CE, UL
0C ~ 50C
-20C ~ +60C
-9
AS35THTD
AS38BSTD
AS57BSTD
A(E)57BSTD
A(E)57GSTD
X, Y, Z 10
WxHxD
mm
WxHmm
184.1 x 144.1 x 47
118.8 x 92.8
172.4 x 132.4
315g
310g
760g
NOTE
1)
o
25 C
2)
3)
4)
http://www.delta.com.tw/industrialautomation/
-10
A80THTD1
AE80THTD
8 TFT LCD
65536
A(E)57CSTD
115.17 x 86.37mm
A(E)10THTD1
10.4 TFT LCD
65536
162.2 x 121.7mm
ROM
16Mbytes
32Mbytes
32Mbytes
Bytes
A256K
AE512K
512K
512K
SM Card
USB Host
Ver 1.1
3AE
3AE
USB Client
3AE
3AE
COM1
RS-232
COM2
RS-232RS-422RS-485
COM3
RS-232RS-422
RS-485AE
x4 +
x1
RS-232RS-422RS-485
x6 +
x1
x7 +
x1
DC +24V-10% ~ +15%(Note 2)
3V CR203215
85dB
IP65NEMA4CE, UL
0C ~ 50C
-20C ~ +60C
-11
WxHxD
mm
WxHmm
A(E)57CSTD
A80THTD1
AE80THTD
A(E)10THTD1
184.1 x 144.1 x 47
172.4 x 132.4
231.4 x 166.4
285.2 x 210.2
760g
1140g
1735g
NOTE
1)
o
25 C
2)
3)
4)
http://www.delta.com.tw/industrialautomation/
-12
DOP-AAEAS
NFPA 70:
National Electrical Code, 2005 Ed.
http://www.delta.com.tw/industrialautomation/
class-3100
10
-1
()
Type 4X
AAE
-2
0.7N-M
6.17lb-inch0.7N-M
AS
0.7N-M
6.17lb-inch0.7N-M
AWG
28 ~ 12
30 ~ 12
7 ~ 8 mm
7 ~ 8 mm
5 kg-cm4.3 lb-in
5 kg-cm4.3 lb-in
5 ~ 6 mm
5 ~ 6 mm
2 kg-cm1.7 lb-in
2 kg-cm1.7 lb-in
AS
AWG
30 ~ 16
30 ~ 16
-3
DOP-A(E)57G(B)(C)STD
DOP-AS35THTD
DOP-AS38BSTD
DOP-A80THTD1
DOP-AE80THTD
DOP-A(E)10THTD1
DOP-AS57BSTD
-4
COM1 AAEAS57BSTD
COM Port
RS-232
1
2
3
4
5
6
7
8
9
Pin
RXD
TXD
GND
RTS
CTS
COM2 A
COM Port
MODE1
RS-232
1
2
3
4
5
6
7
8
9
Pin
MODE2
RS-422
RXDRXD+
TXD+
TXDGND
RTSRTS+
CTS+
CTS-
RXD
TXD
RTS
CTS
MODE3
RS-485
DD+
D+
D-
1
2 Mode3 D+ Pin2Pin3 D- Pin1Pin4
COM2COM3 AEA80THTD1A10THTD1
COM Port
COM
Port
COM2
Pin
COM3
1
2
3
4
5
6
7
8
9
MODE1
RS-232
RXD
TXD
RTS
CTS
MODE2
RS-422
RXDRXD+
TXD+
TXDRTSRTS+
CTS+
CTS-
1
2 Mode3 D+ Pin2Pin3 D- Pin1Pin4
Mode6 D1+ Pin2Pin3 D1- Pin1Pin4 D2+ Pin7Pin8 D2 Pin6Pin9
-5
COM1COM3 AS38BSTDAS35THTD
COM Port
COM Port
1
2
3
4
5
6
7
8
9
COM1
Pin
COM3
MODE1
RS-232
MODE2
RS-232*2
RXD
TXD
RXD1
TXD1
GND
RTS
CTS
TXD2
RXD2
COM2 AS38BSTDAS35THTD
COM Port
MODE1
RS-422
RXDRXD+
TXDTXD+
R-
RR+
TT+
G
MODE2
RS-485
DD+
DD+
GND
COM2
COM Port
COM2
COM3
COM3
RR+
TT+
G
RR+
TT+
MODE1
RS-485*2
DD+
DD+
MODE2
RS-422*2
RXDRXD+
TXDTXD+
GND
RXDRXD+
TXDTXD+
MODE3
RS-422
RXDRXD+
TXDTXD+
CTSCTS+
RTSRTS+
1
2 RS-422 MODE3 COM2COM3
-6
COM
Port
DOP-AE
DOP-A
COM1 RS-232
RS-232
COM2
RS-422
RS-422
COM3
COM3
N/A
DOP-AS57
DOP-AS35AS38
RS-232
RS-232
COM3
RS-422
RS-422
COM3 RS-232
COM3
DOP-AS35BSTDDOP-AS38BSTD
4-R3
36.7
140.8
104.8
)
92.8 +10 (3.65+0.04
0
T
NOTE:
T=1.6mm(0.06in) ~
3.0mm(0.12in)
mm
DOP-AS57BSTD
172.4 +10 (6.79+0.04
)
0
4-R3(0.12)
39.0(1.54) 6.1(0.24)
T
144.1(5.67)
)
132.4+10 (5.21 +0.04
0
184.1(7.25)
NOTE:
T=0.06in(1.6mm) ~
0.12in(3.0mm)
mm
-7
DOP-A(E)57G(B)(C)STD
172.4 +10 (6.79+0.04
0 )
4-R3(0.12)
39.0(1.54) 6.1(0.24)
T
144.1(5.67)
184.1(7.25)
NOTE:
T=1.6mm(0.06in) ~
3.0mm(0.12in)
mm
DOP-A80THTD1DOP-AE80THTD
+0.04
231.4 +10 (9.11 0 )
R
4-
)
12
0.
0(
.
3
6.1(0.24)
44.4 (1.75)
243.1(9.57)
+1
+0.04
0 (6.55 0 )
T
NOTE:
178.1(7.01)
166.4
T=1.6mm(0.06in) ~
3.0mm(0.12in)
mm
DOP-A(E)10THTD1
285.2
+1
0
(11.22
+0.04
0 )
0(
3.
-R
12
0.
43.1(1.70) 6.1(0.24)
297.1(11.70)
NOTE:
T=1.6mm(0.06in) ~
3.0mm(0.12in)
222.1(8.74)
210.2
+1
+0.04
0 (8.27 0 )
mm
-8
AS35THTD
AS38BSTD
AS57BSTD
76.8 x 57.6mm
115.17 x 86.37mm
ROM
Flash ROM
2Mbytes
8Mbytes
SM Card
USB Host
Ver 1.1
128K
16Mbytes
128K
16Mbytes
A256K
AE512K
3
3AE
3AE
COM1
COM3
16Mbytes
COM2
128K
USB Client
A(E)57GSTD
Bytes
A(E)57BSTD
3.5 TFT LCD 3.8 STN LCD 5.7 STN LCD 5.7 STN LCD 5.7 FSTN LCD
65536 8 8 8 16
RS-232
RS-422RS-485
RS-232RS-422RS-485
RS-422
RS-485
RS-232
RS-232RS-422RS-485
AE
x 4 + x 1
DC +24V-10% ~ +15%(Note 2)
3V CR203215
85dB
IP65NEMA4CE, UL
0C ~ 50C
-20C ~ +60C
-9
WxHxD
mm
WxHmm
AS35THTD
AS38BSTD
AS57BSTD
A(E)57BSTD
A(E)57GSTD
184.1 x 144.1 x 47
118.8 x 92.8
172.4 x 132.4
315g
310g
760g
NOTE
1)
o
25 C
2)
3)
4)
http://www.delta.com.tw/industrialautomation/
-10
A80THTD1
AE80THTD
8 TFT LCD
65536
A(E)57CSTD
A(E)10THTD1
10.4 TFT LCD
65536
162.2 x 121.7mm
211.2 x 158.4mm
ROM
16Mbytes
32Mbytes
32Mbytes
Bytes
A256K
AE512K
512K
512K
SM Card
USB Host
Ver 1.1
3AE
3AE
USB Client
COM2
COM3
3AE
3AE
COM1
RS-232
RS-232RS-422RS-485
RS-232RS-422
RS-232RS-422RS-485
RS-485AE
x4 + x6 + x7 +
x1
x1
x1
DC +24V-10% ~ +15%(Note 2)
3V CR203215
85dB
IP65NEMA4CE, UL
0C ~ 50C
-20C ~ +60C
-11
WxHxD
mm
WxHmm
A(E)57CSTD
A80THTD1
AE80THTD
A(E)10THTD1
184.1 x 144.1 x 47
172.4 x 132.4
231.4 x 166.4
285.2 x 210.2
760g
1140g
1735g
NOTE
1)
o
25 C
2)
3)
4)
http://www.delta.com.tw/industrialautomation/