Sunteți pe pagina 1din 12

Courier 5i SL and Courier 6i SL

The high performance XRF on-stream slurry analyzers


State-of-the-art technology Courier SL analyzer systems offer unrivalled sensitivity and the shortest cycle times for process management, monitoring and control of all types of mineral processing plants. Outotec is the leading supplier of advanced process automation systems, control solutions and intelligent instruments to the mineral and metal processing industries. We are both a market and technology leader, having delivered more than 1000 on-stream slurry analyzer systems worldwide.

002 More out of ore!

What can a Courier analyzer do for you?


n Sampling and analysis are performed unattended in the same consistent way around the clock. This creates savings in assaying costs and metallurgical sampling. n Recoveries are improved, as process upsets are detected early and solved rapidly. Frequent assays are necessary for real-time process monitoring and control. n Concentrate quality is controllable and undesired variations are minimized. Plant operation is optimized with smaller circulating loads resulting in higher throughput. n Taking into account sampling and sample preparation, assay accuracy is comparable with a routine manual sample-laboratory procedure as Courier on-stream analyzers use the same wavelength dispersive X-ray uorescence (WDXRF) technology as high-performance laboratory analyzers. n Results from process tests and changes are readily available, which motivates and speeds up process development. n Modular Courier analyzer systems can be easily upgraded and expanded as plant requirements change.

Timeliness of assays The speed of accurate assaying provided by the Courier onstream analyzers enables an immediate reaction to changes in the metallurgical behavior of the otation circuit while monitoring the effect of such a reaction in real time. Frequent manual sampling, sample preparation and laboratory assays, as required for 24/7 real-time process control, is prohibitively expensive in terms of manpower and equipment. If assays are based on strongly ltered or averaged measurements over a long period, they cannot be used for process control. A long time delay between actual process changes and the control action makes feedback control unstable and reported process trends misleading.

More out of ore! 003


Control room
PC user Interface for control room CPI 6720 Ofces PC user Interfaces for laboratory, instrument shop and ofce environment CPI 6720 Outotec remote support PC user interface for remote support

Plant automation system

**************** **************** ****************

Plant ofce network

Encrypted virtual private network (VPN) trough rewall with anti-virus engine

Firewall with anti-virus engine

Analyzer network

Process

PSI 300

Courier

Courier

Courier Remote user Interface for process environment CRI 6710

Particle size analyzer PSI 300 or PSI 500

Sampling and Local analyzer control user interface PCS 6750 CLI 6700

Analyzer probe PRS 4011

Local Sampling and Analyzer analyzer control user interface probe CLI 6700 PCS 6750 PRS 4011

Automation system connections

Analyzer network The local Courier user interface displays the assays, trends and analyzer status information. It can also be used to set up and modify the operation of the Courier analyzer. The local user interface collects analyzer system calibration and diagnostic data for local and remote support. Log and scheduled assay reports can be generated in the user interface PC and shared through the plant network with operators and metallurgists.

Several Courier analyzers can be networked to share common remote user interface PCs. Local and remote user interface operation are very similar in order to minimize learning and con guration time. Outotec's Outocal calibration program can run on one of the networked PCs to access calibration data and calculate the best models for assay calculations. Two redundant process control system connections are available at the analyzer electronics for good availability of assays.

Display for operational status of each sample line.

Assay trends on local operator interface display.

Display for operational status of one selected sample line.

The status of several Courier analyzers can be minimized or expanded as required.

004 More out of ore!

Main Feed

TankCell

Rougher Feed

TankCell

TankCell TankCell

Rougher Tails

TankCell

TankCell

Scavenger Tails

Flotation Tails

AT

AT

AT

AT

AT

AT
Primary Rougher Concentrate
TankCell

AT
Rougher Concentrate
TankCell TankCell

AT

Scavenger Concentrate

AT

Middling Tails

Cleaner Tails

AT

TankCell

Final Concentrate

AT

You have to measure it in order to manage it!


Flash flotation control Monitoring the grinding circuit ash otation concentrate grade helps to produce high-grade concentrate, which is easy to clean or mix directly with nal concentrate, providing signi cant overall recovery improvement. Primary rougher flotation control Monitoring the primary rougher concentrate grade enables the production of high-grade concentrate. Rougher control The rest of the otation circuit is much easier to run, if the rougher section is working properly. Roughers should produce optimal grade rougher concentrate with an acceptable recovery rate. Rougher tails must be monitored for recovery control. If the rougher tail grade is too high, there is often insuf cient scavenger circuit capacity to prevent a recovery loss. Concentrate grade is controlled by otation cell air, level and reagents. The optimal concentrate grade depends on the feed grade, mineralogy, circulating loads and cleaner capacity. On-stream analysis provides vital information for optimizing rougher concentrate production.

FrothMaster 2 froth cameras are used to complement Courier assays to optimize concentrate pull in each cell in a row.

More out of ore! 005

Cleaner control Maintaining nal product quality is critical, while keeping an eye on circulating loads in the cleaner section. The Courier system is able to measure low assays of penalty elements in the presence of a high main element grade to ensure consistent production of the best quality concentrate. Scavenger control Since the rougher tails are already controlled based on the Courier assays, the scavengers simply lower the nal tails assay. Accurate tails assay measurement is important for recovery monitoring and requires a highly sensitive and accurate analyzer. The scavenger concentrate assay is monitored to keep the circulation load under control. Flotation circuit control Typical basic control loops used in otation are illustrated below. Successful assay control requires that the key operating parameters of a otation machine are managed. Basic control loop setpoints are determined by the process operator or an expert system. The Outotec Advanced Control Tools package (ACT) can be used to optimize circuit operation. See left for an example of a typical grade-recovery optimization scheme.
Controller for otation machine slurry level and air feed to each mechanism. Exact level control optimizes slurry level control in a row of machines.

CellStation controller for otation machine slurry level and air feed to each mechanism. Exact level control optimizes slurry level control in a row of machines.

Air Air Air

AT

Analysis sample points

FIC
Level

LIC Level control

FIC LIC
Level

FIC
Level

FIC Flow control

LIC
TankCell TankCell

LIC

TankCell

AT AT Mass pull OK Grade OK Mass pull OK Grade OK Mass pull OK Grade OK AT

The operation of each otation cell in a rougher row is balanced by froth speed measurements to meet rougher concentrate grade target with best possible recovery.

006 More out of ore!

Courier slurry analyzer system


Primary sampling A representative primary sample of the process stream is sent to the multiplexer for secondary sampling. A range of proven Outotec primary samplers is available for various process designs. The low head required by the Courier analyzers usually allows transportation of sample ows by gravity without the need for pumping. Small process ows can be fed through the analyzer secondary sampling system without sampling. Depending on the process requirements, the primary sample ow can be continuous, with or without automatic periodic ushing. Alternatively, the sample ow can be stopped and the delivery line ushed automatically between measurements. This improves sample availability if the slurry contains trash, oversize particles or it forms deposits. Controlled primary sampling is a standard feature in the Courier analyzers. Secondary sampling The full primary sample ow is switched between bypass and level controlled analyzer feed tank by a two-way air cylinder actuated sample hose. The same cylinder moves the hose in opposite direction across a cutter, at programmable intervals in order to collect a representative composite sample. Trash is removed from the samples by self-cleaning screens and entrained air is minimized in a level-controlled constant head feed tank. The tank provides a stable sample ow to the analyzer ow cell. Primary sample availability and ow rate are monitored for diagnostic purposes. The multiplexer is designed to minimize sample changeover times in large systems. While a sample in one multiplexer is being measured, the next sample is already being conditioned in the second multiplexer unit. This allows a fast measurement cycle for all streams. The measurement sequence is fully programmable. For example, critical streams can be measured more frequently and longer measurement time can be used for low grade tailings streams. The switching time between samples is used for internal reference measurements, which are used for monitoring and automatic drift compensation. Assaying The Courier 5i and 6i SL analyzer probes combine the high-performance wavelength and energy dispersive X-ray uorescence methods in a unique and cost-effective way. Automatic reference briquette measurements between sample measurements compensate for drift and provide on-line self-diagnostic tool. The analyzer probe contains the core analytical components of the analyzer in an IP56-rated (NEMA 4X-compliant) stainless steel enclosure.
Monitoring and control FAST LOOP 70300 l/min SECONDARY SAMPLING MULTIPLEXING SCREENING DE-AERATION Process Primary sampling

COMPOSITE COMPOSITE Composite SAMPLES SAMPLES samples

FLOW CELL 25 l/min Analysis Calibration samples

Features of Courier SL analyzers


n Unrivalled sensitivity n Short cycle time n Lower assaying cost n Modular system can be tailored for any site and updated as required

More out of ore! 007

Calibration sampling The built-in calibration sampler enables an operator to take a truly representative and repeatable sample from the actually measured slurry for comparative laboratory assays. The calibration data can be read from the analyzer into a networked PC for the Outocal calibration program. De-multiplexing With high grade samples, optional de-multiplexing can be used to divert the small intermittent 25 l/min measured ow to the desired return line.

User interface The analyzer local user interface panel high resolution touch screen shows the most recent assays, assay trends, sample line and analyzer status information. Some control switches and indicator lamps complement the panel. The sampling and analyzer control cabinet houses interface and control modules for primary and secondary sampling system monitoring and control.

Courier 5i SL medium power analyzer model


Courier 5i SL analyzer is designed for accurate and reliable on-stream X-ray uorescence (XRF) measurement of element concentrations in slurries for up to 12 sample streams and normal concentration levels. It has a lower power X-ray tube than Courier 6i SL, which allows the use of smaller power supplies and a Peltier cooling system.

Courier 6i SL high-power analyzer model


The Courier 6i SL is a high-performance member of the Courier on-stream XRF analyzer family for the real-time assaying of slurry process streams. This high-power analyzer system offers unrivalled sensitivity and the shortest cycle times for process management, monitoring and control of all types of mineral processing plants.

008 More out of ore!

ANALYZER PROBE Sample in 25 l/min WDXRF channel 50 thick window


detector
PRS 4011

LOCAL USER INTERFACE


CLI 6700

Jet flow cell

Spectrometer

Signal preamplifier SAMPLING CONTROL


ANALYZER NETWORK Switch

atic om Aut rence refe tter shu

PES 3450

PCS 6750

X-ray tube

Digital multichannel analyzer and processor for assay calculation

ICM 4300

ICM 4300 SAMPLING Expansion controller 1 AUTOMATION SYSTEM

Filter

Signal preamplifier

Main controller

1 mm sensitive layer Controlled turbulent flow in the sensitive layer provides a representative sample and prevents scaling.

Detector

ICM 4300 SAMPLING

ICM 4300

EDXRF channel
SAMPLING Expansion controller 3

COOLING AND TEMPERATURE CONTROL Sample out


CCA 4061

Expansion controller 2

Expansion cabinet PCSE 4360

The secrets of high performance


Sample presentation The patented JetCell technology ensures that a representative fresh sample is always presented for assaying at the window surface. The ow cell window is kept clean and free of scaling caused by active slurry contact. The window can be changed manually or automatically using the AWC 4030 Automatic Window Changer option. Analysis Courier excites the sample in the ow cell sensitive layer using a high-intensity X-ray tube. Atoms in the sample react by emitting uorescence radiation, characteristic of each individual element in the sample. Courier 5i and 6i SL analyzers use highresolution wavelength-dispersive analyzer technology for critical assays. Complementary energy-dispersive technology is used to increase the range of elements analyzed and to extend the capability of the system to measure up to 12 assays per stream. Analyzer system control The primary and secondary sampling system and analyzer measurements are controlled by electronics in the PCS 6750 cabinet. The modular system includes several ICM 4300 Interface and Control Modules connected by a high speed serial bus. Each multiplexer unit is controlled by its own ICM module. Primary sampling is controlled by the I/O available in the multiplexer control ICM modules or dedicated modules in large analyzer systems.

AWC 4030 Automatic Window Changer.

More out of ore! 009

Wavelength-dispersive technology
The wavelength-dispersive detection channel measures only the narrow element peak (blue). A high-resolution spectrometer separates the peak before it reaches the detector. Nearby element peaks do not overlap and the background signal is minimal. Because the full capacity of the detector is used for the relevant peak only, a highpower X-ray tube can be used and analysis speed and sensitivity are high. Wavelength-dispersive detection is deployed by high-performance laboratory analyzers. Several element-specic wavelength-dispersive channels are used in Courier analyzers for the simultaneous measurement of all critical elements.
Wavelength-dispersive channel WDXRF, 0.12% Zn.

Energy-dispersive technology
The energy-dispersive detection channel (Si(Li), Si-PIN, SDD or proportional counter) measures the whole spectrum (blue). Measuring a small Zn peak (green arrow) is a challenge, since most of the detected counts cannot be used for the specic assay. Limited resolution and its deterioration with count rates above 10 kcounts per second usually limit useful X-ray intensity. Analysis speed and sensitivity are low. Energy-dispersive detectors can be used for less critical measurements of high-grade assays, as a cost-effective complement to wavelength-dispersive detectors. One energy-dispersive detector can measure several element peaks at the same time.
Energy-dispersive channel EDXRF, 0.12% Zn.
Scatter

H
1

He

Periodic table of elements


Be
4

Li
3

B
5

C
6

N
7

O
8

F
9

Ne
10

Na
11

Mg
12

AI
13

Si
14

P
15

S
16

CI
17

Ar
18

K
19

Ca
20

Sc
21

Ti
22

V
23

Cr
24

Mn
25

Fe
26

Co
27

Ni
28

Cu
29

Zn
30

Ga
31

Ge
32

As
33

Se
34

Br
35

Kr
36

Rb
37

Sr
38

Y
39

Zr
40

Nb
41

Mo
42

Tc
43

Ru
44

Rh
45

Pd
46

Ag
47

Cd
48

In
49

Sn
50

Sb
51

Te
52

I
53

Xe
54

Cs
55

Ba
56 57-71

Hf
72

Ta
73

W
74

Re
75

Os
76

Ir
77

Pt
78

Au
79

Hg
80

Tl
81

Pb
82

Bi
83

Po
84

At
85

Rn
86
Actinides 89-103

Fr
87

Ra
88

Ac
89

Th
90

Pa
91

U
92

Np
93

Pu
94

Am Cm
95 96

Bk
97

Cf
98

Es
99

Fm
100

Md
101

No
102

Lr
103

Lanthanides 57-71

La
57

Ce
58

Pr
59

Nd
60

Pm
61

Sm
62

Eu
63

Gd
64

Tb
65

Dy
66

Ho
67

Er
68

Tm
69

Yb
70

Lu
71

X-ray fluorescence (XRF) analysis of slurry samples Slurry and air attenuate strongly the low energy XRF signal from light elements. This makes on-line analysis of elements lighter than calcium (Ca) impractical. With ow cell technology, the analysis of heavier elements is possible as the fresh representative sample is brought right onto the surface of the measurement cell window.

010 More out of ore!

Specications
Analysis method The wavelength-dispersive X-ray uorescence method uses X-ray tube excitation. Energy-dispersive channels are available. No radioactive isotope sources are used, minimizing exposure, re and disposal risks. Number of sample streams One Courier 6i SL analyzer system can measure up to 24 sample streams (Courier 5i SL 12 streams). Each multiplexer module handles up to 6 sample streams. Number of simultaneous assays The Courier 5i and 6i SL analyzers can provide up to 12 simultaneous assays for elements from calcium to uranium (atomic numbers 20 to 92) and solids content from each process sample. Assay calculation models can be automatically switched according to changing mineralogy. Sample measurement time The sample measurement time is selectable for each sample, the typical time being 1530 seconds (Courier 5i SL 60 seconds). Analysis cycle The normal analysis cycle for 12 samples is 12 minutes, and 16 minutes for 18 streams (1316 minutes for 12 stream Courier 5i SL), depending on the measuring time for each sample. Assays are calculated and reported based on freshly measured data for a true, real-time analysis. Accuracy Outotec's accuracy specication is based on the measurement of owing slurry samples using measurement times for real applications. Briquette measurements and long measurement times give unrealistic results. Accuracy of measurement is a function of sample parameters such as matrix composition, mineralization and particle size. Typically, under normal operating conditions, a 36% relative standard deviation for minor concentrations, and a 14% relative standard deviation for major concentrations, is achieved for individual slurry sample measurements of concentration levels well above the minimum detection limit. Power supply Single phase AC, 230 V +10%, -15% at 10 A 50/60 Hz or 115 V 10% at 20 A 50/60 Hz. Double conversion 3 kW UPS, 10 minutes minimum (Courier 5i SL 1200 W). Instrument air Pressure 510 bar (75145 psi) 16 l/min (0.6 norm. cuft/min) average consumption. Flushing water Sand- ltered raw water, 26 bar (3085 psi) average 30 l/min (8 gal/min) peak 100 l/min (26 gal/min). Minimum detection limit The WDXRF-measurement channel's detection limit is 330 ppm for most elements in slurry samples. Using the EDXRF-measurement channel, the minimum detection limit is typically 100500 ppm. Installation requirements The Courier 5i and 6i SL analyzers can be installed on one level (low head) or two levels. Analyzer has to be protected from direct sunlight preferably in a prefabricated shelter. Stability The analyzer's short-term stability under the speci ed conditions is better than 0.1% relative. Automatic internal reference measurements compensate for long-term drift. Maintenance The Courier 5i and 6i SL analyzers are designed for minimal maintenance. Analyzer probe window change is automatic, with an Automatic Window Changer option. The analyzer system has built-in self and remote diagnostics capabilities. Continuous training, proactive and corrective service agreements are available. Measurable concentration range The typical measurable concentration range is 0.004%100% by weight for slurries. Analyzer calibration An optional integrated calibration sampler takes a repeatable and representative sample for analyzer calibration. The Outocal software is available for interactive calibration model design.

More out of ore! 011

MSA sampler

Operating ambient temperature at sea level +5 +45C (41113F), no condensation. Temperature control is based on an air-cooled chiller.(Courier 5i SL has Peltier cooler) Local and remote operator interfaces up to +32C, with cooling option up to +45C ambient temperature. Storage temperature -25 +60C (-13 140F) Environmental classification Analyzer multiplexers, probe and probe control set, IP56 (designed to meet NEMA 4X).
Water

Process ow by gravity LSA sampler Process ow by gravity


Water

MXA 4645 Multiplexer VFU 0114 Composite sample ltering

leak-proof ceiling

Shipping and installed weight The typical total shipping weight is 1000 kg (2200 lbs) for a 12-stream system, and 1250 kg (2750 lbs) for an 18-stream system. Each 6-stream multiplexer unit weighs 225 kg (500 lbs). Primary samplers and sample transportation are not included in the above weights. ISO 9001 quality assurance We are ISO 9001 certied and have a rigorous quality management policy to ensure that the customer's quality expectations are met. The analyzer is certi ed according to the EMC, LVD and MD directives.
Process ow by gravity

Courier 6

PSA sampler Process ow by pressure

adjustable 1860-2060

DMA 4642 De-multiplexer

5000

Two-level installation layout.

Note: These speci cations are for a typical con guration and project scope only. Actual scope and performance data vary according to individual plant and project speci cations and product variations. Please see the product data sheets and installation manual for details.
LSA sampler

Water

Courier and PROSCON are registered trademarks of Outotec Oyj.


Water

1900

VFU 0114 Composite sample lter

Courier 6

De-multiplexer PSA sampler 6000 Process ow by pressure

Low-head installation layout.

1200

Secondary sample pump

adjustable 18602060

Courier 5i and 6i SL sampling and analyzer system features are covered by several patents and patent applications owned by Outotec Oyj.

MXA 4645 Multiplexer

PCS 6750 Probe and sampling control

PRS 4011 Analyzer probe CLI 6700 Local user interface


room to open covers

900

maximum 3300

CLI 6700 Local user interface

room to open covers

2100 minimum free height

PCS 6750 Probe and sampling control

PRS 4011 Analyzer probe

1900

Outotec is a worldwide technology leader in minerals and metals processing, providing innovative and environmentally sound solutions for a wide variety of customers in minerals processing, iron and steel, aluminum and non-ferrous metals industries. Outotec Oyj is listed on the Nasdaq OMX Helsinki.

automation@outotec.com www.outotec.com

Copyright 2008 Outotec Oyj. All rights reserved. Outotec and More out of ore! are registered trademarks of Outotec Oyj.

3068EN. Pinta/Libris, Helsinki, Finland. December 2008

S-ar putea să vă placă și