NOTES: 1. ALL DIMENSIONS ARE IN mm AND LEVELS ARE IN METERS U.N.O. 2. CONCRETE GRADE FOR R.C.C.

WORK FOR CHIMNEY SHELL= M30. FOR FOUNDATION = M25. ORDINARY PORTLAND CEMENT (OPC) SHALL BE USED FOR CONSTRUCTION OF R.C.C. SHELL & RAFT. 3. ALL REINFORCEMENT SHALL BE OF GRADE Fe415 CONFORMING TO IS:1786. 4. STRUCTURAL STEEL WORK SHALL BE AS PER IS:800:2007. 5- ELECTRICAL & LIGHTNING PROTECTION WORK SHALL CONFORM TO SPECIFICATIONS. 6. STEEL FLUES SHALL BE FABRICATED FROM CORTEN B STEEL HAVING ULTIMATE TENSILE STRENGTH NOT LESS THAN 4lON/mm2 CONFORMING TO IS:2062(GKA:)E-A). 7. INSULATION MATERIAL OF RESIN BONDED ROCK HAVING MAXIMUM COEFFICIENT OF THERMAL CONDUCTIVITY OF 0.52 MW/CM/hr/"c AT A MEAN TEMPERATURE OF 100" SHALL BE PROVIDED TO THE EXTERNAL FACE OF STEEL FLUE AS PER THE SPECIFICATIONS AS FOLLOWS. i) A MINIMUM OF 4 LAYERS EACH OF 25 THK. FOR THE WHOLE HEIGHT OF FLUE WITH DENSITY OF 100 kg/m^ fl) A MINIMUM OF 6 LAYERS EACH OF 25 THK. FOR THE EXPOSED REGION ABOVE ROOF LEVEL WITH DENSITY OF 200 kg/m3 8. THE EXPANSION COMPENSATOR SHALL BE PROCURED FROM A SPECIALIST MANUFACTURER. APPROVED BY OWNER/ CONSULTANT. THE VATERIAL FOR EXPANSION COMPENSATOR SHALL CONFORM TO THE REQUIREMENT OF THE TECHNICAL SPECIFICATION. 9. THE ROOF SLAB SHALL BE LINED wrTH 20mm THICK ACID RESISTANT TILES CONFORMING TO IS: 4457 WrTH BEDDING MORTAR OF AVERAGE THICKNESS 10mm CONFORMING TO IS: 4832 PART I OF POTASSIUM SILICATE BASE. THE TILES SHALL BE POINTED USING PHENOLIC BASED RESIN CEMENT MORTAR CONFORMING TO IS:4832 PART 2. AND IT SHOULD BE ACID PROOF. CHEMICAL RESISTANT. WATER PROOF. 10. EL 0.00 CORRESPONDS TO RL (+)449.250 m 11. NET SBC AT EL. (-)6.000 IS TAKEN AS 350 KN/SQM. PAINTING ALL PAINTS SHALL BE APPLIED TO A TOTAL DFT OF 150 MICRONS. A) THE ENTIRE INTERNAL SURFACE OF THE WIND SHIELD AND TOP 50M OF OUTSIDE CONCRETE SURFACE INCLUDING HORIZONTAL SURFACE OF PLATFORM AND CONCRETE SHELL SHALL BE PAINTED WITH ACID AND HEAT RESISTANT PAINT CONFORMING TO IS: 158 WflH TOTAL DRY FILM THICKNESS OF PAINT SHALL BE NOT LESS THAN 150 M. 8) ICRONS. THE ENTIRE OUTSIDE SURFACE OF CONCRETE SHELL SHALL BE PAINTED WITH ALTERNATE BANDS OF SIGNAL RED AND WHITE COLOUR. OUT OF WHICH TOP 50 M SHALL BE PAINTED WITH ACID AND HEAT RESISTANT PAINT AND REST OF THE OUTS IDE SURFACE SHALL BE PAINTED WITH SYNTHETIC E. C) THE BEAM V EMBERS OF THE INTERNAL PLATFORM AND STRUCTURAL MEMBERS OF STAIRCASE EXCEPT STAIR TREADS SHALL BE PAINTED WITH 2 COATS OF ZINC CHROMATE RED OXIDE PRIMER AND 2 COATS OF SYNTHETIC ENAMEL PAINT OF APPROVED BRAND AND SHADE AFTER SURFACE PREPARATIONS AS PER IS: 1477. D) FLUES SHALL NOT BE PAINTED.

NOTES: 1 ALL DIMENSIONS ARE IN mm AND LEVELS ARE IN METERS UNELSS OTHERWISE NOTED. 2 STRUCTURAL STEEL WORK SHALL BE AS PER IS:800-2007 3 ALL STRUCTURAL MEMBERS OF STAIRCASE SHALL BE FABRICATED 2FROM MILD STEEL HAVING ULTIMATE TENSILE STRENGTH NOT LESS THAN 410N/mm CONFORMING TO IS:2062 (GRADEA). 4 MICRONS. THE ENTIRE OUTSIDE SURFACE OF CONCRETE SHELL SHALL BE PAINTED WITH ALTERNATE BANDS OF SIGNAL RED AND WHITE COLOUR, OUT OF WHICH TOP 50 M SHALL BE PAINTED WITH ACID AND HEAT RESISTANT PAINT AND REST OF THE OUTS IDE SURFACE SHALL BE PAINTED WITH SYNTHETIC E. 5 ALL LEVELS ARE GIVEN TO TOP OF GRATING UNO. 6 THIS DRAWING SHALL BE READ IN CONJUNCTION WfTH DRAWING NO. 5818/E/DD-049 7 STAIR TREADS AND GRATINGS SHALL BE HOT-DIP GALVANISED AFTER FABRICATION.

8 THE PROPERTY CLASS OF BOLT SHALL BE 4.6 CONFORMING TO IS: 1363 UNLESS STATED OTHERWISE. 9 EL0.00 CORRESPONDS TO RL+449.250M. 10 ALL WELD SHALL CONFORM TO IS:816. NOTES: 1 ALL DIMENSIONS ARE IN MILLIMETER AND LEVELS ARE IN METER UNLESS OTHERWISE SPECIFIED. 2 DIMENSIONS SHALL NOT BE SCALED OFF FROM THE DRAWING. WRITTEN DIMENSIONS ARE TO BE FOLLOWED. 3 STAINLESS STEEL PLATE AND COUNTERSUNK SCREWS SHALL BE OF GRADE AlSI-304. 4 P.T.F.E. SHALL CONFORM TO BS:5400 & BEARING STRESS SHALL BE 20MPa 5 LOAD BEARING BLOCK (SINDANYO BLOCKS) SHALL SATISFY THE FOLLOWING PHYSICAL PROPERTIES: (i) MINIMUM COMPRESSIVE STRESS PRIOR TO ONSET OF COMPRESSION YIELD OF NOT LESS THAN '2 N/Sq.mm. (ii) THERMAL CONDUCTIVITY SHALL BE 0.06 W/m AS PER THE SPECIFICATION CONSIDERING FINE GAS TEMPERATURE AS 160'C AND LIMITING OUTSIDE SURF4CB TEMPERATURE OF INSULATION BLOCK AS 60'C. (iii) DENSITY SHALL BE 19 kN/cu.M. TEST CERTIFICATE SHALL BE SUBMITTED FOR INSULATION BLOCK. 6 ADHESIVES FOR FIXING P.T.F.E. AND LOAD BEARING INSULATION BLOCK TO STEEL SURFACES SHALL BE AS PER TECHNICAL SPECIFICATIONS/ MANUFACTURERS SPECIFICATIONS/ B.S.CODE AS ABOVE. 7 SURFACE OF P.T.F.E. IN CONTACT WITH STAINLESS STEEL SHALL BE DIMPLED IN ACCORDANCE WITH BS:5400-9.2:1983 LUBRICATED WITH SILICONE GREASE AND PROTECTED FROM DAMAGE OR CONTAMINATION AT ALL STAGES PRIOR TO ERECTION OF FLUES. 8 P.T.F.E. AND STAINLESS STEEL BEARING PLATES SHALL COMPLY WrTH RELEVANT REQUIREMENTS OF BS:5400-9.2:1983 AND IN PARTICULAR THOSE RELATING TO WORKMANSHIP AND MANUFACTURING TOLERANCES. 9 FULL CONTACT SURFACES OF WELDED CONNECTION SHALL BE WELDED WITH 8mm THK. WELD U.N.O. 10 BOLTS SHALL BE 20* WITH 4.6 CLASS U.N.O. 11 BEARING STRESS OF LEAD SHALL BE 9MPa.

NOTES: 1. ALL DIMENSIONS ARE IN MM AND ELEVATIONS ARE IN METERS UNLESS OTHERWISE NOTED. ELO.OO CORESPONDS TO RL+449.250M. 2. ALL FILLET WELDS ARE 6MM SHOP WELD UNLESS OTHERWISE NOTED. 3. ALL WELDS OF PLATE GIRDER FLANGES TO WEB SHALL BE BY 8mm FILLET WELD 4. LENGTH OF ALL MEMBERS, FLANGE CUTTING AT END SHALL BE VERIFIED BY FULL SCALE LAYOUT. 5. ALL WELDS SHALL CONFORM TO IS:816 AND IS:823 6. STRUCTURAL STEEL WORK SHALL BE AS PER IS:800:2007 7. ALL STRUCTURAL STEEL, FLATS OF THICKNESS UP TO 25mm SHALL CONFORM TO IS:2062 GRADE A. 8. STRUCTURAL STEEL MEMBERS SHALL BE PAINTED WITH TWO COATS OF ZINC CHROMATE RED OXIDE PRIMER & 2 COATS OF SYNTHETIC ENAMEL PAINT OF APPROVED BRAND & SHADE AFTER SURFACE PREPARATION AS PER IS: 1477. 9. PLATES THICKER THAN 20mm SHALL BE PREHEATED AND STRESS RELIEVED FOR WELDING. 10. THE PROP ERTY CLASS OF BOLT SHALL BE 4.6 CONFORMING TO IS: 1363 UNLESS STATED OTHERWISE. 11. GROUTING SHALL BE OF FREE FLOW NSG TYPE OF EARLIER APPROVED 2 MANUFACTURE WITH MIN. COMPRESSIVE STRENGH OF 35 N/mm 12. ALL PLATES OVER 25mm THK. SHALL BE TESTED LAMINATION IMPERFECTIONS PRIOR TO FABRICATION. LEGEND: PG T.O.C. ST - PLATE GIRDER - TOP OF CONCRETE - STIFFENER PLATE

S-ar putea să vă placă și