Sunteți pe pagina 1din 3

DESIGN CRITIERIA

1.

IN ORDER TO QUALIFY UNDER THIS DESIGN,


THE FLANGES SHALL BE OF EQUAL AND
CONSTANT AREA. (APP. F7.1.b, page 5-102)
DIAPHRAGM IS NOT BRACING MEMBER, SINCE L IS
DIFFERENT WITH l in F1.3, page 5-47.

2.
3.

TOP END FORCES, P & M, SHOULD INCLUDE


IMPACT FACTOR, 1.25, IF THEY ARE FROM MOVABLE
COVER. (A4.2, page 5-29)

INPUT DATA & DESIGN SUMMARY


COLUMN DIMENSIONS

bf =

BEAM DIMENSIONS

bf =

96

in ( 2438 mm )

tf =

in ( 25 mm )

tw =

0.75

in ( 19 mm )

d1 =

780

in ( 19812 mm )

d2 =

700

in ( 17780 mm )

H1 =

200

ft ( 61.0 m )

96

in ( 2438 mm )

tf =

in ( 25 mm )

tw =

0.75

in ( 19 mm )

d3 =

550

in ( 13970 mm )

d4 =
L =

240
323.7

in ( 6096 mm )
ft ( 98.7 m )

H2 =

224.6

ft ( 68.5 m )

BEAM STIFFENER SPACING

a bm =

ft ( 2.4 m )

COLUMN STIFFENER SPACING

a col =

ft ( 2.4 m )

END HEIGHT

UNBRACED LENGTH / PURLIN SPACING

L b,top =

36

ft ( 11.0 m )

UNBRACE
UNB
RACED
D LENGTH AT BOT
OTT
TOM FLANGE

L b,bot =

36

ft ( 11.0
11 0 m )

UNBRACED LENGTH AT OUTSIDE OF COLUMN FLANGE


S =
FRAME SPACING
120
ft ( 36.6 m )
STEEL YIELD STRESS
TOTAL GRAVITY LOAD

Fy =
w =
=
w LL =
F =
P =
M =

AVAILABLE LIVE ROAD


LATERAL LOAD
END LOADS

Weight =

STEEL COST

50
36
4.32
21.4
377.6
874.0
70727.6
31.1

L c , outside =

36

N / mm )
ksi (
345
psf ( " - " for wind uplift)
kips / ft ( 63.0 kN / m )
2
kg / m )
psf (
104

ft ( 11.0 m )

THE FRAME DESIGN IS ADEQUATE.

kips ( 1679.4 kN, " - " to left direction )


kips ( 3887.5 kN, " - " to uplift )
ft-kips ( 314596.5 kN-m, " - " to uplift )
kg / m2 )
psf (
152

ANALYSIS
DETERMINE REACTIONS
RH =

377.6

kips

RV =

2272.4

kips

R M = 372568.8 ft-kips

DETERMINE ALLOWABLE FLEXURAL STRESS (APP. F7.4, pg 5-103)

where

A f = tf bf

 = MIN[(dL - d0) / d0 , 0.268 L/d0, 6.0]

A To = tf bf + d0 tw / 6

I To = (tf bf3 + d0 tw3 / 6) / 12

(cont'd)

Column
Beam (+)
Beam (-)

Length
177.1
296.9
296.9


0.11
0.48
0.48

A To
183.50
126.00
126.00

I To
73732
73729
73729

r To
20.05
24.19
24.19

Hs
1.15
1.36
1.36

Hw
1.00
1.01
1.01

F s
3.32
8.14
8.14

Kv
354.72
178.00

Cv
0.30
0.30

F b
5.13
5.19

F w
364.527
524.76
524.76

B
1.61
1.49
1.49

F b
30.00
30.00
30.00

DETERMINE ALLOWABLE SHEAR STRESS (F4, pg 5-49)


where

Column
Beam

a
8.0
8.0

h
778.00
548.00

h / tw
1037
731

h = dL - 2 tf

0.5

380 / F y
54
54

DETERMINE ALLOWABLE COMPRESSIVE STRESS (APP. F7.3, pg 5-102)


where

K =

(effective length factor by an analysis)

S = K  l / r ox

29000

E=

Column
Beam

l
36.0
36.0

K
2.0
2.5

Cc
107
107

Ix
3.3E+07
2246400

A
717.00
372.00

r ox
215.18
77.71

ksi
S
4.02
13.90

F a
29.73
28.91

CHECK EACH SECTION CAPACITIES

Column
Beam

Section
d (in)
4
I (in )

d0

dL

tf

bf

tw

Af

700
240

780
550

1
1

96
96

0.75
0.75

96
96

1
2
3
780
753
727
58862700 53960848 49328151.9

4
5
6
7
8
9
10
11
12
13
700
550
511
473
434
395
356
318
279
240
4.5E+07 2.5E+07 2.1E+07 1.7E+07 1.4E+07 1.1E+07 8917696 6839074 5083382 3628800

Aw (in2)
N (kips)
V (kips)
M (ft-k)
f a (ksi)

585.00
2272.4
2272.4
-372569
2.92

565.00
2272.4
2272.4
-353166
3.00

545.00
2272.4
2272.4
-333764
3.08

525.00
2272.4
2272.4
-314361
3.17

412.50
172.2
2020.4
-222834
0.28

383.44
158.9
1876.8
-187184
0.28

354.38
145.7
1733.1
-156287
0.27

325.31
132.5
1589.5
-130144
0.26

296.25
119.2
1445.9
-108754
0.24

267.19
106.0
1302.3
-92118
0.23

238.13
92.7
1158.7
-80234
0.22

209.06
79.5
1015.1
-73104
0.20

180.00
66.2
871.5
-70728
0.18

F a (ksi)

29.73

29.73

29.73

29.73

28.91

28.91

28.91

28.91

28.91

28.91

28.91

28.91

28.91

f v (ksi)

3.88

4.02

4.17

4.33

4.90

4.89

4.89

4.89

4.88

4.87

4.87

4.86

4.84

F v (ksi)

5.13

5.13

5.13

5.13

5.19

5.19

5.19

5.19

5.19

5.19

5.19

5.19

5.19

f b (ksi)

29.6

29.6

29.5

29.4

29.5

27.5

25.6

24.0

22.7

22.1

22.3

24.1

28.1

F b (ksi)

30.00

30.00

30.00

30.00

30.00

30.00

30.00

30.00

30.00

30.00

30.00

30.00

30.00

f a < F a [Satisfactory]

f v < F v [Satisfactory]

f b < F b [Satisfactory]

CHECK COMBINED FLEXURE AND AXIAL FORCE (APP. F7.4, pg 5-104)

1.3

(cont'd)

Column
Beam

f bl
29.62
29.51

f a0
2.92
0.28

F a
29.73
28.91

F b
30.00
30.00

F e'
9262.11
773.12

Cm'
1.00
1.00

( fa , fb )
1.09
0.99

[Satisfactory]

DESIGN STIFFENERS
1. BEARING STIFFENERS ARE REQUIRED AT EACH END SUPPORT. (K1.8, page 5-82)
2. DETERMINE STIFFENER SIZE.
tw =

1 1/2

in

b st / t w =

6.00

A eff =

33.75

in2

fa =

25.9

ksi

b st =

in

0.5

< 95 / Fy , AISC-ASD, B5.1


[Satisfactory]
4
in
I =
927

E s = 29000 ksi
0.5
=
K l / r = 0.75 h / ( I / A eff )

34.1

2
0.5
=
C c =(2  E s / F y )

107

26.6

>

ksi, (AISC-ASD, E2, page 5-42)


fa

[Satisfactory]

DETERMINE STEEL COST AND AVAILABLE ROOF LIVE LOAD

Column
Beam


SW (pcf)
( f)
490
490

Fl
(f 3 )
Flanges (ft
298.3
250.0

Available Roof Live Load =

Web
W b (ft
(f 3 )
682.6
610.8

36.0

Stiffers
S iff (ft
(f 3 )
277.3
248.2

psf -

14.6

Misc.(ft
Mi
(f 3 )
50
50

psf =

TA (f
(ft 2 )
38844
38844

21.4

W i h (lb / f 2 )
16.5
14.6
31.1
psf

S-ar putea să vă placă și