Sunteți pe pagina 1din 3

MANUFACTURING GEC MODEL EM 610B SERIAL/EQUIP.NO UNIT # 2 CUSTOMER ASTA KERAMASAN ENERGI, PT HI JOB# INSPECTED BY : HERMAWAN D.

SAKSONO REPORT NO : PT LEVEL


QTY

PENETRANT TESTING REPORT

: I
PART NO.

DATE
ITEM DESCRIPTION

: SEPT 26, 2011


TEST PERFORMED: Initial Latest Procedur No : Witness on test/ Defective areas by : GENERAL PENETRANT DESCRIPTION FUORESCENT (Magnaflux RED DYE SKL-SP1) OTHER PENETRANT DWELL TIME: 15 MINUTES 30 MINUTES Repair

3 EA

# 6.3 # 6.7 # 6.8

BURNER

TEST AREA:

WELDING AREA

COMPOSITION: COLOR CONTRAS: REMOVER: DRYING: PETROLEUM BASE SOLVENT WIPE FUORESCENT MANUAL DRIER AMBIENT TEMP. DRYING RED WATER BASE WATER RINSEABLE OTHERS DEVELOPER APPLICATION: AQUEOUS NON AQUEOUS OTHER OTHERS OTHER

INSPECTION RESULT : FOUND NO CRACKS INDICATION, AS SHOWN ON PHOTOGRAPHS :


HERMAWAN D. SAKSONO
INSPECTOR SIGNATURE

QC COMMENT :

APPROVED BY :

42

MANUFACTURING GEC MODEL EM 610B SERIAL/EQUIP.NO UNIT # 2 CUSTOMER ASTA KERAMASAN ENERGI, PT HI JOB# INSPECTED BY : HERMAWAN D. SAKSONO REPORT NO : PT LEVEL : I DATE : SEPT 26, 2011

PENETRANT TESTING REPORT

Fig.1 Penetrant Inspection on Burner # 6.3

Fig.2 Location of Penetrant Inspection on Welding Area Burner # 6.3

Fig.3 Penetrant Inspection on Burner # 6.7

Fig.4 Location of Penetrant Inspection on Welding Area Burner # 6.7

43

MANUFACTURING GEC

PENETRANT TESTING REPORT

MODEL SERIAL/EQUIP.NO CUSTOMER HI JOB#

EM 610B UNIT # 2 ASTA KERAMASAN ENERGI, PT

INSPECTED BY : HERMAWAN D. SAKSONO PT LEVEL : I

REPORT NO : DATE : SEPT 26, 2011

Fig.5 Penetrant Inspection on Burner # 6.8

Fig.6 Location of Penetrant Inspection on Welding Area Burner # 6.8

SITE MANAGER PT. ASTA KERAMASAN ENERGY

MAINTENANCE MANAGER PT. ASTA KERAMASAN ENERGY

PROJECT MANAGER PT. PJBS INSPECTOR

Moch. Hosen

Catur Wahyu Hidayat

Mudjito