Column Slab Connection (Square Column with Flat Plate Slab System)

l
1
span l
1
= 30.0 ft 360 in
l
2
span l
2
' = l
2
= 20.0 ft 240 in
Column Size c (in) = 20 in
Design Slab Thickness d (in) = 10 in
Miscellaneous Uniform Dead Load (psf) = 25 psf
Design Uniform Live Load (psf) = 100 psf
Concrete Strength f'
c
(psi) = 8000 psi
Unit Weight of Concrete
c
(pcf)= 150 pcf
Punching Shear Calculation
Width of critical section b
0
= 4 ( c + d )
b
0
= 2(c+d/2)+(c+d)
interior b
0
= 120 in
exterior b
0
= 110 in
= 1 (for normal concrete)
Long side to short side of column = 1
Shear Calculation 1 For 2, [Eqn 11-31, ACI 11.11.2.1]
V
c
= 429325 lb 429.33 k
Shear Calculation 2 [Eqn 11-32, ACI 11.11.2.1]

s
= 40 (Interior Column)
s
= 30 (Exterior Column)
Interior Column V
c
= 572433 lb 572.43 k
Exterior Column V
c
= 507384 lb 507.38 k
Shear Calculation 3 [Eqn 11-33, ACI 11.11.2.1]
V
c
= 429325 lb 429.33 k
d b f
b
d
V
c
s
c 0
'
0
2
o
|
|
.
|

\
|
+ =
d b
0
'
c c
f 4 V =
d b
0
'
c c
f 4 V =
Nominal Punching Shear V
c
= V
n
(Smallest out of the 3 shear calculations)
(Interior Column) V
c
= V
n
= 429325 lb 429.33 k
(Exterior Column) V
c
= V
n
= 429325 lb 429.33 k
Moment Transfer Between Column and Slabs
Combined Uniform Dead Load w
d
= 1.2 * (
c
+ Misc. DL )
Combined Uniform Dead Load w
d
' =w
d
= 180 psf (with 1.2 factor)
Uniform Live Load w
l
= 160 psf (with 1.6 factor)
Interior Column
Clear Span of l
1
l
n
' = l
n
= 28.33 ft 340 in
Column Moment M
u
=
0.07 [ ( w
d
+ 0.5 w
l
) l
2
l
n
2
- w
d
' l
2
' ( l
n
' )
2
]
M
u
= 89911.1 lb-ft 89.91 k ft
Concrete Area in Critical Section A
c
= b
0
d = 1200 in
2
8.33 ft
2
b
1
= b
2
= ( c + d ) = 30 in
12333 in
3
0.60

v
= 1 -
f
= 0.40
201875 lb 201.88 k
v
u,AB
= 203.22 psi 0.20 ksi
v
c,spec
= V
c
/ A
c
= 357.77 psi 0.36 ksi
[v
u,AB
v
c,spec
] Check : OK!

,

=

=

1

1
+3
2
+
3
3
=

=
1
1 +
2
3

1

2
=

= (
1

2
)( +) =
Exterior Column
b
1
=b
2
c+d/2
b
1
=b
2
25 in
A
c
= (2b1+b2)d
A
c
= 750 in
2
7083.333 in
3
0.4
0.75
428.5416667 kip.ft 682.3611
128.5625 kip.ft 204.7083
v
AB
= 475.0489 psi 4.75E-01 ksi
v
CD
= 543.8489 psi 5.44E-01 ksi
v
c,spec
= V
c
/ A
c
= 572.43 psi 0.57 ksi
[v
u,AB
v
c,spec
] Check : OK!
[v
u,CD
v
c,spec
] Check : OK!

=
1
1 +
2
3

1

2
=
=

=

12
(2
1
+)(2
1
+4
2
+5d)=

=
1

= 0.3
0
=

0
=

0
=

= 0.3
0
=

0
=

2
8

[Eqn 11-31, ACI 11.11.2.1]
[Eqn 11-32, ACI 11.11.2.1]
(Exterior Column)
[Eqn 11-33, ACI 11.11.2.1]
(Smallest out of the 3 shear calculations)
kip.ft
kip.ft
Column Slab Connection (Square Column with Flat Plate Slab System)
l
1
span l
1
= 30.0 ft 360 in
l
2
span l
2
' = l
2
= 20.0 ft 240 in
Column Size c (in) = 20 in
Design Slab Thickness d (in) = 10 in
Miscellaneous Uniform Dead Load (psf) = 25 psf
Design Uniform Live Load (psf) = 100 psf
Concrete Strength f'
c
(psi) = 8000 psi
Unit Weight of Concrete
c
(pcf)= 150 pcf
Punching Shear Calculation
Width of critical section b
0
= 4 ( c + d )
b
0
= 2(c+d/2)+(c+d)
interior b
0
= 120 in
exterior b
0
= 110 in
= 1 (for normal concrete)
Long side to short side of column = 1
Shear Calculation 1 For 2, [Eqn 11-31, ACI 11.11.2.1]
V
c
= 429325 lb 429.33 k
Shear Calculation 2 [Eqn 11-32, ACI 11.11.2.1]

s
= 40 (Interior Column)
s
= 30 (Exterior Column)
Interior Column V
c
= 572433 lb 572.43 k
Exterior Column V
c
= 507384 lb 507.38 k
Shear Calculation 3 [Eqn 11-33, ACI 11.11.2.1]
V
c
= 429325 lb 429.33 k
d b f
b
d
V
c
s
c 0
'
0
2
o
|
|
.
|

\
|
+ =
d b
0
'
c c
f 4 V =
d b
0
'
c c
f 4 V =
Nominal Punching Shear V
c
= V
n
(Smallest out of the 3 shear calculations)
(Interior Column) V
c
= V
n
= 429325 lb 429.33 k
(Exterior Column) V
c
= V
n
= 429325 lb 429.33 k
Moment Transfer Between Column and Slabs
Combined Uniform Dead Load w
d
= 1.2 * (
c
+ Misc. DL )
Combined Uniform Dead Load w
d
' =w
d
= 180 psf (with 1.2 factor)
Uniform Live Load w
l
= 160 psf (with 1.6 factor)
Interior Column
Clear Span of l
1
l
n
' = l
n
= 28.33 ft 340 in
Column Moment M
u
=
0.07 [ ( w
d
+ 0.5 w
l
) l
2
l
n
2
- w
d
' l
2
' ( l
n
' )
2
]
M
u
= 89911.1 lb-ft 89.91 k ft
Concrete Area in Critical Section A
c
= b
0
d = 1200 in
2
8.33 ft
2
b
1
= b
2
= ( c + d ) = 30 in
12333 in
3
0.60

v
= 1 -
f
= 0.40
201875 lb 201.88 k
v
u,AB
= 203.22 psi 0.20 ksi
v
c,spec
= V
c
/ A
c
= 357.77 psi 0.36 ksi
[v
u,AB
v
c,spec
] Check : OK!

,

=

=

1

1
+3
2
+
3
3
=

=
1
1 +
2
3

1

2
=

= (
1

2
)( +) =
Exterior Column
b
1
=b
2
c+d/2
b
1
=b
2
25 in
A
c
= (2b1+b2)d
A
c
= 750 in
2
7083.333 in
3
0.6
0.75
455.4583 kip.ft 23.13889 kip.ft
136.6375 kip.ft 6.941667 kip.ft
v
AB
= 544.0729 psi 5.44E-01 ksi
v
CD
= 368.2969 psi 3.68E-01 ksi
v
c,spec
= V
c
/ A
c
= 572.43 psi 0.57 ksi
[v
u,AB
v
c,spec
] Check : OK!
[v
u,CD
v
c,spec
] Check : OK!

=
1
1 +
2
3

1

2
=
=

=

12
(2
1
+)(2
1
+4
2
+5d)=

=
1

= 0.3
0
=

0
=

0
=

= 0.3
0
=

0
=

2
8