Sunteți pe pagina 1din 2

ASCT/EEE/LAB/BEE-05 (Star & Delta Connections)

EXPERIMENT NO. - 05
AIM: - Study of Star & Delta Connections of 3-phase circuit. INSTRUMENTS REQUIRED:
S. No. 1. 2. 3. 4. 5. Instruments 3-Phase bulb load Ammeter Ammeter Voltmeter Voltmeter Range 230V, 400V star 0-2A 0-10A 0-250V 0-500V Quantity 1 1 1 1 1

THEORY:
Star Connection: In a 3-phase AC circuit, line voltage is equal to 1.732 times of the phase voltage and line current is equal to the phase current. i.e. VL = 3 VPh; ILine = IPh Delta Connection: In a 3-phase delta connection line current is equal to 1.732 times of the phase current and line voltage is equal to phase voltage. i.e. IL = 3 IPh; VLine = VPh

Circuit Diagram:

PROCEDURE:

Page 1 of 2

ASCT/EEE/LAB/BEE-05 (Star & Delta Connections) 1. For star connection, connect the voltmeters and ammeters as shown in circuit diagram. Switch ON the supply & note down the readings of voltmeters and ammeters 2. For Delta connection, connect the voltmeters and ammeters as shown in the circuit diagram. Switch ON the supply and note down the readings of voltmeters and ammeters

OBSERVATION TABLE:
Type of Connection Star Delta Vline Vphase Iline Iphase

RESULT:
1. For star connection, Vline / Vphase = 1.732 2. For delta connection, Iline/Iphase = 1.732

PRECAUTIONS:
1. Use the instruments of the given range. 2. Make the connections tight.

Page 2 of 2