PRODUCT AND ENGINEERING MANUAL

4.3 SECONDARY FRAMING


TABLE OF CONTENTS

Table of Contents ........................................................................................................... 1


SF0010PE - Secondary Framing .......................................................................... 2
SF0020PE - Z Section Properties....................................................................... 3
SF0030PE - C Section Properties ...................................................................... 4
SF0040PE - S Section Properties ...................................................................... 5
AG0001 - Z Roof Purlins..................................................................................... 6
SF0050PE - Z Wall Girts (Inset/Flush) ............................................................... 7
SF0060PE - Z Wall Girts (Bypass Bolted Clips) ................................................. 8
SF0065PE - Z Wall Girts (Bypass Welded Clips) ............................................... 9
SF0070PE Open-Web Welded Joists ............................................................... 10
SF0071PE -Open-Web All Bolted Joists ............................................................. 11
SF0072PE Open Web Bolted Joists Detail Continued ..................................... 12
ClearBay CFR ..................................................................................................... 13
SF0080PE - Cold-Formed Box Beams ............................................................... 14
SF0090PE - Standard Purlin Spacing (Gable Building) ...................................... 15
SF0100PE - Standard Purlin Spacing (Single Slope Building) ........................... 16
SF0110PE - Standard Girt Spacing .................................................................... 17

4.3.1

PRODUCT AND ENGINEERING MANUAL


4.3 SECONDARY FRAMING
SF0010PE - SECONDARY FRAMING

1. Standard Secondary Framing consists of Cold Formed Z shaped roof purlins


and wall girts. C shaped wall girts may be used for framed openings and other
special applications.
2. Z and C members are shop punched for simple field bolted connections.
3. Z and C members are available in either 8 or 10 inch depths. 12 and 14 inch
members depths are available on a limited basis. Consult the plant for specifics.
4. Optional Open-Web joists are available for wide bay applications with spans over
40 feet, and for mezzanine applications.
5. All section properties listed in this section were determined using the proper
provisions of the Cold-Formed Steel Design Manual, AISI, 1996 Edition. Any
use of these properties for design should also be completed per these provisions.
6. As a standard, all bypass roof purlins and wall girts will utilize a shop welded clip.
Bolted clips are also available.
7. Some Nucor Divisions may offer welded clips for inset or flush girts.
Contact your NBS Division for availability.
LAST REVISION
DATE:
08/06/04
BY: KMC CHK: RJF

DETAIL NAME IF APPLICABLE


SF0010PE.DWG

4.3.2

PRODUCT AND ENGINEERING MANUAL


4.3 SECONDARY FRAMING
SF0020PE - Z SECTION PROPERTIES

Design t
Gross Ix
Wt.
(in^4)
(#/Ft)
2.65
7.668
2.95
8.482
3.29
9.470
3.68
10.599
4.37
12.574
4.86
13.984
5.15
14.829

Section

D (in.)

B (in.)

Design t
(in.)

8Z054
8Z060
8Z067
8Z075
8Z089
8Z099
8Z105

8.00
8.00
8.00
8.00
8.00
8.00
8.00

2.5
2.5
2.5
2.5
2.5
2.5
2.5

0.054
0.060
0.067
0.075
0.089
0.099
0.105

10Z060
10Z067
10Z075
10Z089
10Z099
10Z105
10Z120

10.00
10.00
10.00
10.00
10.00
10.00
10.00

2.5
2.5
2.5
2.5
2.5
2.5
2.5

0.060
0.067
0.075
0.089
0.099
0.105
0.120

3.35
3.74
4.19
4.97
5.53
5.87
6.71

12Z075
12Z089
12Z099
12Z105
12Z120

12.00
12.00
12.00
12.00
12.00

3.5
3.5
3.5
3.5
3.5

0.075
0.089
0.099
0.105
0.120

5.21
6.18
6.88
7.30
8.34

LAST REVISION
DATE:
03/20/12
BY: DLF CHK: EGB

Net Sx
(in^3)

Ma
(in.-Kip)

1.506
1.836
2.089
2.374
2.994
3.392
3.648

49.596
60.466
68.807
78.188
98.596
111.720
120.150

14.331
16.001
17.910
0.500
23.632
25.062
28.635

2.264
2.674
3.223
4.063
4.600
4.945
5.658

74.560
88.082
106.144
133.809
151.508
162.872
186.337

33.087
39.258
43.664
46.308
52.915

3.916
5.192
6.161
6.596
7.841

128.971
171.004
202.909
217.249
258.244

DETAIL NAME IF APPLICABLE


SF0020PE.DWG

4.3.3

PRODUCT AND ENGINEERING MANUAL


4.3 SECONDARY FRAMING
SF0030PE - C SECTION PROPERTIES

SECTION

D
(in.)

B
(in.)

DESIGN t
(in.)

8C060
8C067
8C075
8C089
8C099
8C105

8.00
8.00
8.00
8.00
8.00
8.00

2.75
2.75
2.75
2.75
2.75
2.75

0.060
0.067
0.075
0.089
0.099
0.105

2.95
3.29
3.68
4.37
4.86
5.15

10C060
10C067
10C075
10C089
10C099
10C105

10.00
10.00
10.00
10.00
10.00
10.00

2.75
2.75
2.75
2.75
2.75
2.75

0.060
0.067
0.075
0.089
0.099
0.105

3.35
3.74
4.19
4.97
5.53
5.87

LAST REVISION
DATE:
03/20/12
BY: DLF CHK: EGB

DESIGN t Wt. GROSS lx


(plf)
(in^4)

Net Sx
(in ^3)

Ma
(in-kip)

8.540
9.535
10.670
12.656
14.074
14.924

1.697
1.996
2.277
2.831
3.255
3.502

12.560
14.240
16.180
19.606
22.066
23.544

14.405
16.083
18.000
21.353
23.746
25.181

2.098
2.514
3.048
3.857
4.422
4.751

12.605
14.300
16.260
19.726
22.220
23.719

DETAIL NAME IF APPLICABLE


SF0030PE.DWG

4.3.4

PRODUCT AND ENGINEERING MANUAL


4.3 SECONDARY FRAMING
SF0040PE - S SECTION PROPERTIES

SECTION

D
(in.)

B
(in.)

8S075
8S089
8S099
8S105
8S120

8.00
8.00
8.00
8.00
8.00

3.625
3.625
3.625
3.625
3.625

0.075
0.089
0.099
0.105
0.120

4.19
4.97
5.53
5.87
6.71

12.97
15.39
17.11
18.14
20.72

2.531
3.107
3.533
3.794
4.527

12S075
12S089
12S099
12S105
12S120

12.00
12.00
12.00
12.00
12.00

3.625
3.625
3.625
3.625
3.625

0.075
0.089
0.099
0.105
0.120

5.21
6.18
6.88
7.30
8.34

33.04
39.20
43.60
46.23
52.82

3.894
5.194
6.171
6.613
7.839

LAST REVISION
DATE:
03/20/12
BY: DLF CHK: EGB

DESIGN t DESIGN t Wt. GROSS lx


(in.)
(plf)
(in^4)

Net Sx
(in ^3)

DETAIL NAME IF APPLICABLE


SF0040PE.DWG

4.3.5

PRODUCT AND ENGINEERING MANUAL


4.3 SECONDARY FRAMING
AG0001 - Z ROOF PURLINS

NOTES:
1) ALL PURLIN CONNECTIONS UTILIZE DIAMETER BOLTS.
2) Z PURLINS HAVE SYMMETRICAL FLANGES FOR EASE OF ERECTION.
3) Z PURLINS ARE ECONOMICAL FOR SPANS UP TO AND INCLUDING 40
FEET.

LAST REVISION
DATE:
08/06/04
BY: KMC CHK: RJF

DETAIL NAME IF APPLICABLE


AG0001.DWG

4.3.6

PRODUCT AND ENGINEERING MANUAL


4.3 SECONDARY FRAMING
SF0050PE - Z WALL GIRTS (INSET/FLUSH)

LAST REVISION
DATE:
02/09/01
BY: CDM CHK: RJF

DETAIL NAME IF APPLICABLE


SF0050PE.DWG

4.3.7

PRODUCT AND ENGINEERING MANUAL


4.3 SECONDARY FRAMING
SF0060PE - Z WALL GIRTS (BYPASS BOLTED CLIPS)

LAST REVISION
DATE:
08/06/04
BY: KMC CHK: RJF

DETAIL NAME IF APPLICABLE


SF0060PE.DWG

4.3.8

PRODUCT AND ENGINEERING MANUAL


4.3 SECONDARY FRAMING
SF0065PE - Z WALL GIRTS (BYPASS WELDED CLIPS)

LAST REVISION
DATE:
08/06/04
BY: KMC CHK: RJF

DETAIL NAME IF APPLICABLE


SF0065PE.DWG

4.3.9

PRODUCT AND ENGINEERING MANUAL


4.3 SECONDARY FRAMING
SF0070PE OPEN-WEB WELDED JOISTS

LAST REVISION
DATE:
06/11/09
BY: AES CHK:

DETAIL NAME IF APPLICABLE


SF0070PE.DWG

4.3.10

PRODUCT AND ENGINEERING MANUAL


4.3 SECONDARY FRAMING
SF0071PE -OPEN-WEB ALL BOLTED JOISTS

LAST REVISION
DATE:
06/11/09
BY: AES CHK:

DETAIL NAME IF APPLICABLE


SF0071PE.DWG

4.3.11

PRODUCT AND ENGINEERING MANUAL


4.3 SECONDARY FRAMING
SF0072PE OPEN WEB BOLTED JOIST DETAIL CONTINUED

LAST REVISION
DATE:
10/31/11
BY: RT CHK: EGB

DETAIL NAME IF APPLICABLE


SF0072PE.DWG

4.3.12

PRODUCT AND ENGINEERING MANUAL


4.3 SECONDARY FRAMING
CLEARBAY CFR

This system is only available for projects with roof joists and CFR panels.
The ClearBay CFR system was set in place to minimize joist bridging by utilizing
the capacity of the CFR roof panel system. This reduction in bridging will also
result in a reduction of cost.
ClearBay CFR is available in a welded and all bolted option.
These joists will be detailed the same as our typical roof joist system. The
reduced bridging will be specified by Vulcraft.
Click the link below to see the predetermined bridging rows and spacing for bays
that are 40 to 60in width. Any bay sizes other than these would be custom
quoted. This table only applies to ClearBay CFR projects.
ClearBay CFR Bridging Locations

LAST REVISION
DATE: 10/23/09
BY: AES CHK:

DETAIL NAME IF APPLICABLE

4.3.13

PRODUCT AND ENGINEERING MANUAL


4.3 SECONDARY FRAMING
SF0080PE - COLD-FORMED BOX BEAMS
1. Cold-formed box beams consist of two C or S sections, forming a cold-formed tube.
2. These tubes may be square or rectangular in shape.
3. The height of the box beam matches the purlin depth. The depth of the box beam will be 8,
10, or 12, depending on the design requirements of a particular project.
4. Cold-formed box beams are typically used as a replacement for the eave strut, eave purlin, or
strong-back eave beam.
5. Standard connection for the box beam to primary framing member is with either (2) or (4)
diameter A325 bolts per end.

LAST REVISION
DATE: 10/23/09
BY: AES CHK:

DETAIL NAME IF APPLICABLE

4.3.14

PRODUCT AND ENGINEERING MANUAL


4.3 SECONDARY FRAMING
SF0090PE - STANDARD PURLIN SPACING (GABLE BUILDING)

* INDICATES ODD SPACE AS FOLLOWS:


ROOF SLOPE

PURLIN SPACE

< 1/2:12

MIN. = 1-10

MAX = 3-10

1/2:12

MIN. = 1-10

MAX = 5-6

NOTE: THESE SPACINGS ARE TO BE USED FOR BOTH NUCOR CFR AND
NUCOR CLASSIC ROOF SYSTEMS.
WITH NUCOR CFR ROOF (UL CLASS 90, UL 580, CONSTRUCTION NO. 590).
- MAXIMUM PURLIN SPACING IS 5-0 W/ PURLINS.
- MAXIMUM PURLIN SPACING IS 5-6 W/ JOISTS.

LAST REVISION
DATE:
10/11/11
BY: RT CHK: EGB

DETAIL NAME IF APPLICABLE


SF0090PE.DWG

4.3.15

PRODUCT AND ENGINEERING MANUAL


4.3 SECONDARY FRAMING
SF0100PE - STANDARD PURLIN SPACING (SINGLE SLOPE BUILDING)

* INDICATES ODD SPACE AS FOLLOWS:


ROOF SLOPE

PURLIN SPACE

< 1/2:12

MIN. = 1-10

MAX = 3-10

1/2:12

MIN. = 1-10

MAX = 5-6

NOTE: THESE SPACINGS ARE TO BE USED FOR BOTH NUCOR CFR AND
NUCOR CLASSIC ROOF SYSTEMS.
WITH NUCOR CFR ROOF (UL CLASS 90, UL 580, CONSTRUCTION NO. 590).
- MAXIMUM PURLIN SPACING IS 5-0 W/ PURLINS.
- MAXIMUM PURLIN SPACING IS 5-6 W/ JOISTS.

LAST REVISION
DATE:
10/11/11
BY: RT CHK: EGB

DETAIL NAME IF APPLICABLE


SF0100PE.DWG

4.3.16

PRODUCT AND ENGINEERING MANUAL


4.3 SECONDARY FRAMING
SF0110PE - STANDARD GIRT SPACING

LAST REVISION
DATE:
02/09/01
BY: CDM CHK: RJF

DETAIL NAME IF APPLICABLE


SF0110PE.DWG

4.3.17