Sunteți pe pagina 1din 2

New Modules Supported from STEP 7 V5.

3 SP1 Onwards

Product

MLFB

FW Version

Short Description

SIMATIC 400
CPU 412-1 6ES7 412-1XF04-0AB0 V4.0 Work memory 72KB code and 72KB of data; 0.1ms/1000 instructions; 4KB DI/O; 16 connections 1*DP/MPI; send and receive capability for direct data exchange; DP constant bus cycle time and clocking editing; routing; multi-computing capable; firmware V4.0 Work memory 128KB code and 128KB of data; 0.1ms/1000 instructions; 4KB DI/O; 16 connections 1*DP/MPI and 1*DP; send and receive capability for direct data exchange; constant bus cycle time and clocking editing; routing; multi-computing capable; firmware V4.0 Work memory 256KB code and 256KB data 0.06 ms/1000 instructions; 8KB DI/O; 32 connections 1*DP/MPI and 1*DP; send receive capability for direct data exchange; constant bus cycle and clocking editing; routing; multicomputing capable;firmware V4.0 Work memory 0.7 MB code and 0.7MB of data 0.06 ms/1000 instructions 8KB DI/O; 32 connections 1*DP/MPI, 1*DP and 1 receptacle for IF modules; send and receive capability for direct data exchange; constant bus cycle time and the clocking editing, routing, mulitcomputing capable; firmware V4.0 Work memory 2.8MB code and 2.8 MB of data 0.04 ms/1000 instructions; 16KB DI/O; 64 connections; 1*DP/MPI, 1*DP and 1 receptacle for IF modules; send and receive capability for direct data exchange; constant bus cycle time; routing; multicomputing capable; firmware V4.0 Work memory 1.4MB code and 1.4 MB data 0.04 ms/1000 instructions; 16KB DI/O; 64 connections; 1*DP/MPI and 1*DP; send and receive capability for direct data exchange; constant bus cycle time and clocking editing; routing; multicomputing; firmware V4.0; can be used for safety applications Work memory 1.4MB code and 1.4MB data 0.04 ms/1000 instructions; 16KB DI/O; 64 connections 1*DP/MPI and 1*DP; send and receive capability for direct data exchange; constant bus cycle time; routing; multicomputing capability; firmware V4.0 Work memory 10MB code and 10MB of data; 0.03 ms/1000 instructions; 16KB DI/O; 64 connections; 1*DP/MPI, 1*DP and 2 receptacles for IF modules; multi-computing computable, send and receive capable for direct data exchange, constant bus cycle and clocking editing, routing, firmware V4.0 S7 CP for Industrial Ethernet, PROFINET IO controller, ISO and TCP/IP with SEND-RECEIVE and FETCH-WRITE interface, long data, UDP, TCP, ISO, S7 communication, routing, module replacement without PG, with Web server and E-mail, 10/100 Mbps, fixed MAC address, initialization over LAN, IP multicast, time-of-day sync. using SIMATIC mode or NTP, access protection with IP access list, FTP, SNMP, DHCP, HTML diagnostics, data storage on C plug, 4-port switch, PROFINET, firmware V2.0 IF964 interface module, PROFIBUS DP, 12 Mbps

CPU 412-2 DP

6ES7 412-2XG04-0AB0 V4.0

CPU 414-2 DP

6ES7 414-2XG04-0AB0 V4.0

CPU 414-3 DP

6ES7 414-3XJ04-0AB0 V4.0

CPU 416-3 DP

6ES7 416-3XL04-0AB0 V4.0

CPU 416F-2

6ES7 416-2FK04-0AB0 V4.0

CPU 416-2 DP

6ES7 416-2XK04-0AB0 V4.0

CPU 417-4

6ES7 417-4XL04-0AB0 V4.0

CP-443-1 Advanced-IT

6GK7 443-1EX40-0XE0 V2.0

IF 964-DP

6ES7 964-2AA04-0AB0

A5E00320993-01 08/2004

New Modules Supported from STEP 7 V5.3 SP1 Onwards

Product

MLFB

FW Version _ _ V1.0

Short Description

SIMATIC 300
CPU 317-2 PN/DP 6ES7 317-2EJ10-0AB0 V2.3 Work memory 512Kbytes; 0.3ms/1000 instructions; PROFINET IO Controller; MPI+ DP connection (DP master or DP slave); multi-tier configuration up to 32 modules; send and receive capability for direct data exchange; constant bus cycle time; routing; S7 communication (loadable FBs/FCs); Firmware V2.3 S7 CP for Industrial Ethernet TCP/IP with SEND/RECEIVE and FETCH/WRITE interface, long data, UDP, TCP, S7 communication (server), routing, module replacement without PG, 10/100 Mbps, fixed MAC address, initialization over LAN, IP multicast, IP configuration using DHCP/ FB, firmware V1.0 Module 8 IQ-SENSE for connecting IQ-SENSE devices Analog output module 4AO/16 bits, supports isochrone mode

CP 343-1 Lean

6GK7 343-1CX00-0XE0 V1.0

8x IQ-SENSE IDENT SM 332 AO4x16Bit

6ES7 338-7XF00-0AB0 IDENT 6ES7 332-7ND02-0AB0

SIMATIC PC Station
CP 1612 CP 1512 6GK1 161-2AA00 6GK1 151-2AA00 V6.2.1 SIMATIC NET CP 1612 Industrial Ethernet, PROFINET IO controller, ISO, TCP/IP, S7 connections, PG functions, PCI bus, routing V6.2.1 SIMATIC NET CP 1512 Industrial Ethernet, PROFINET IO controller, ISO, TCP/IP, S7 connections, PG functions, PCMCIA, routing OPC Server for the DP, FDL, FMS, S7 (between different subnets), ISO/TCP, SNMP, DP master class 2, PROFINET V6.2.1 protocols, PROFINET IO, SIMATIC NET CD 6/2004 ... Substitute for any Industrial Ethernet module, PROFINET IO controller, ISO, TCP/IP, S7 connections, PG functions, V6.2.1 routing

OPC Server IE-General-PN-IO

PROFIBUS DP
IM151-7 F-CPU 6ES7 151-7FA01-0AB0 V2.1 Work memory 64/96kilobytes; 0.3ms/1000 instructions; MPI+ DP I/O (DP master or DP slave); send and receive capability for direct data exchange; Firmware V2.1; expansion with a maximum of 63 modules of the ET200S range; can be used for safety applications Siwarex CS weighing modules Absolute Encoder SIMODRIVE sensor - 13/27 Bit - DPV1/DPV2 - Publisher & Isochron supported SIMATIC Vision Sensor VS130-2

ET200S Siwarex CS SIMODRIVE sensor isochron VS130-2

7MH4 910-0AA01 6FX2001-5xPxx 6GF1 018-3BA

PROFINET IO
IM151-3 PN IE/PB Link 6ES7 151-3AA00-0AB0 6GK1 411-5AB00 PROFINET I/O interface module IM 151-3 PN for ET200S electronic module IE/PB Link, PROFINET IO Proxy incl. soft real time, connects Industrial Ethernet with PROFIBUS, Routing, DatensatzGateway, Firmware V1.0

A5E00320993-01 08/2004