Sent: To: Cc: Subject: Attachments: Great work by Nathan.

Bower, Fred Wednesday, April 06, 2011 7:50 AM Lafferty, Nathan; Trapp, James Krohn, Paul RE: PB Hardened Pipe drawing pict55.jpg

I took a second look and from this picture from the cryptome.org site, it appears that units 2, 3, and 4 had vent pipes on the rear of the reactor building, but unit 1 did not. From this view, it is hard to tell what is running up the front (side facing the turbine building) of the reactor building, but is seems too small a diameter to be a hardened vent. Fred Bower Senior Resident Inspector Peach Bottom Atomic Power Station ----Original Message ----From: Lafferty, Nathan Sent: Tuesday, April 05, 2011 5:15 PM To: Trapp, James Cc: Bower, Fred; Krohn, Paul Subject: RE: PB Hardened Pipe drawing The "ventpipe_internet" pic was found on http://cryptome.org/eyeball/npp/62npp-eyeball.htm under peach bottom. I took "VentPipeClosel & 2" at PB. It is hard to tell what these pipes are at Fukushima based on the pictures. In "fukushima_2pipes" it appears there could be 2 vent pipes. If the pipe at fukushima were coming out of the ground it could be more discernable. Better photographs are needed.

----Original Message----From: Trapp, James Sent: Tuesday, April 05, 2011 4:20 PM To: Lafferty, Nathan Subject: RE: PB Hardened Pipe drawing You are right on the mark. Do you have or can you get a picture of the vent at PB? Also, do you think this is the hardened vent at Fukushima? Thanks again!

----- Message ----Original


From: Lafferty, Nathan Sent: Tuesday, April 05, 2011 4:17 PM
106

or

To: Trapp, ,James Cc: Krohn, Paul; Bower, Fred Subject: RE: PB Hardened Pipe drawing Upon first inspection it looks similar to the hardened pipe at PB. At PB, the hardened pipe rises vertically out of the ground next to the Rx Bldg, kinks through a rad monitor, then follows the Rx Bldg until it extends above the top. It looks like a tall, 16" Inner Diameter, green pipe bracketed onto the outside of the Rx Bldg.

----Original Message ----From: Trapp, James Sent: Tuesday, April 05, 2011 3:51 PM To: Lafferty, Nathan; Krohn, Paul; Bower, Fred Subject: RE: PB Hardened Pipe drawing Nathan - this is great. By chance do you have any photos or describe what the vent looks like after it exits secondary containment. I am going to send you some photos of Fukushima. I was wondering if a vent line going up the side of the building looks like the hardened vent. ----Original Message ----From: Lafferty, Nathan Sent: Tuesday, April 05, 2011 2:57 PM To: Trapp, James; Krohn, Paul; Bower, Fred Subject: PB Hardened Pipe drawing Drawing is attached. The hardened pipe vent path is highlighted. The pipe penetrates primary containment at N-219. Contact me with any questions. Nathan Lafferty ----Original Message ----From: R1Scan [mailto:R1Scananrc..ov] Sent: Tuesday, April 05, 2011 2:52 PM To: Lafferty, Nathan Subject: Scan from Peach Bottom HP5035 Please open the attached document. This document was digitally sent to you using an HP Digital Sending device.

107