Necessary Composition
MS2830A-040/041/043* MS2830A-062 MX269018A A0086A : Signal Analyzer : Low Phase Noise Performance : Analog Measurement Software : USB Audio

*: MS2830A-043 cannot be installed MS2830A-062 and signal generator options simultaneously ( Refer to Slide 27)

Version 1.00

ANRITSU CORPORATION
Slide 1 MX269022A-J-L-1

What is MX269018A Analog Measurement Software?


The MX269018A Analog Measurement Software supports measurement of RF TRx characteristics of wireless equipment using analog modulation. Installing it in the MS269xA Signal Analyzer main frame supports RG signal generation for TRx tests and monitoring of demodulated RF signals from wireless equipment for efficient evaluation at R&D and manufacturing/ verification of analog wireless equipment.

Analog Measurement Software

Remote
Control

Speaker AF Output AF Input

: Provided by Anritsu. * Customers must provide the Audio Analyzer/Generator, ATT and Divider. Slide 2 MX269022A-J-L-1

MX269018A Measurement System Images


Supports TRx tests and demodulation signal output for analog wireless equipment Tx Test
Input AF from Audio Generator to wireless equipment and measure Tx characteristics of RF signals output from wireless equipment.

Supports DCS code analysis display(FM)

Rx Test

Output RF signals for examination cofirming the operation and Rx Sensitivity tests from analog signal generator to wireless equipment. Measure AF output from wireless equipment with external Audio Analyzer for Rx Sensitivity tests.

User waveform output function


Reads any AF signals from file and supports modulation output Creating file outputs tone signalling signals, such as DTM (Dual Tone Multiple Frequency).

Demodulation Voice Output

Demodulation of RF signals sent from wireless equipment to USB connector. The voice signals can be monitored with USB Audio and commercial speaker.

Speaker

Slide 3 MX269022A-J-L-1

MX269018A Function of software and necessary composition


Supports various functions necessary for analog wireless equipment tests
Function of analog measurement software and necessary composition Modulation method of target signal Requires Options Analog measurement software function*1 FM M AM
Carrier Frequency and Carrier Frequency Error RF Frequency Transmit Power RF Power Modulation measurement*2 Deviation(FM), Radian(M), Depth(AM) Result of analyzed DCS Code DCS Code Demodulation Frequency Frequency Effective Value for Level at Demodulation Frequency Level Distortion Ratio of Demodulation Frequency(S/N) Distortion Power vs Time Graph Result TX Measure measurement result display

1., 2., 3. 5. is mandatory

Tx Test

1.Signal Analyzer (MS2830A-040/041/043*) 2.Low Phase Noise Performance (MS2830A-062) 3.Analog Measurement Software (MX269018A)

AF Measure measurement result display

*MS2830A-043 cannot be installed MS2830A-062 and 4. analog signal generator simultaneously. 1.+2.+3.+ 4.Analog Signal Generator (Refer to Slide27 about 4.) 1.+2.+3.+ 5.USB Audio(A0086A) 6.commercial speaker

Rx Test

FM/M/AM Outputs from analog signal generator Demodulate Input RF Signals from wireless equipment and Output Voice from USB connector*3

Demodulated Voice Output

*1:Spurious measurement is also possible by Spectrum analyzer standard measurement function. *2:Deviation(FM), Radian(M), Depth(AM) *3:The voice can be monitored by connecting a speaker etc. on the market with USB Audio.

Slide 4 MX269022A-J-L-1

MX269018A Measurement Items

Tx Tests

The Tx measurements supported by the MX269018Aare listed below. Spurious measurements are supported with a spectrum analyzer.
display items TX Measure RF Frequency RF Power Deviation Radian Depth DCS Code AF Measure Frequency Level Distortion Graph result summary Analysis results of RF signal Carrier Frequency and Carrier Frequency Error RF Power Frequency Deviation(FM) Phase Deviation(M) Modulation(AM) DCS Code analysis result(FM) Analysis results of demodulated signal Demodulated frequency Rms level with demodulated frequency Distortion with demodulated frequency(S/N) Power vs Time with demodulated frequency
Supports DCS code analysis display(FM)

Slide 5 MX269022A-J-L-1

MX269018A Tx Mode Screen


Switch to Tx measurement mode to perform Tx tests.

Tx Tests

Tx mode screen
(MX269018A) [F1: Mode] > TX

(2)

(1): Measurement parameter


Displays set parameters.

(1) (3)

(2) Status message


Displays signal status.

(3): TX Measure window


*Separately explained on following slides Displays measurement results for frequency, level and modulation for input RF signal.

(4) (5)

(4): Function menu


Displays functions executed by function keys.

(5): AF Measure window


*Separately explained on following slides Displays frequency, level, distortion ratio and graph for demodulated AF signals. Slide 6 MX269022A-J-L-1

MX269018A Tx Mode Screen RF Measurement Result (FM)


TX Measure window (for FM) (1) (2) (4)
(1): RF Frequency (2): RF Power
Displays difference between carrier frequency of measured signal and set frequency of Tx Frequency.

Tx Tests

(3)

Displays measurement signal power results in dBm and Watt units when RF Power Set Reference is Off. When RF Power Set Reference is set to On, the measured RF Power at that instant becomes the Reference Power and subsequent displayed RF Power results are referenced to that value.

(3): Deviation
Displays +Peak, -Peak, (+Peak to -Peak)/2, RMS results for measured signal frequency deviation in Hz units.

(4): DCS Code


Displays DSC code analysis results with octal notation in three digits when DCS Code Analysis ON. The initial code of the displayed result is displayed when the detected code matches the 83 Standard Code defined by TIA-603-C. If there is no match, *** is displayed. Codes in parentheses display code matches other than the 83 Standard Code. Slide 7 MX269022A-J-L-1

MX269018A Tx Mode Screen RF Measurement Result ( M)


TX Measure window (when M) (1) (2)
(1): RF Frequency
Displays difference between carrier frequency of measured signal and set frequency of Tx Frequency.

Tx Tests

(3)

(2): RF Power
Displays measured signal power results in dBm and Watt units when RF Power Set Reference is Off. When RF Power Set Reference is set to On, the measured RF Power at that instant becomes the Reference Power and subsequent displayed RF Power results are referenced to that value.

(3): Radian
Displays +Peak, -Peak, (+Peak to -Peak)/2, RMS results for phase deviation in radian units.

Slide 8 MX269022A-J-L-1

MX269018A Tx Mode Screen RF Measurement Result (AM)


TX Measure window (when AM) (1) (2)
(1): RF Frequency
Displays difference between carrier frequency of measured signal and set frequency of Tx Frequency.

Tx Tests

(3)

(2): RF Power
Displays measured signal power results in dBm and Watt units when RF Power Set Reference is Off. When RF Power Set Reference is set to On, the measured RF Power at that instant becomes the Reference Power and subsequent displayed RF Power results are referenced to that value.

(3): Depth
Displays +Peak, -Peak, (+Peak to -Peak)/2, RMS results for modulation in %.

Slide 9 MX269022A-J-L-1

MX269018A Tx Mode Screen AF Measurement Result (FM, M, AM)


AF Measure window FM (1) (2) (4) M (1) (2) (4) AM (1) (2) (4)
Slide 10 MX269022A-J-L-1

Tx Tests

(3)

(1): Frequency
Displays maximum level frequency from demodulated frequency spectrum in Hz units.

(2): Level
Displays level of above frequency (FM in kHz rms, M in radian rms, AM in % rms).

(3): Distortion

(3)

Displays distortion ratio measurement results when above frequency used as signal source (in dB and % units).

(4): Graph Display


Displays Time vs. Level for demodulation signals. Level axis (Y axis) scaled automatically according to measurement results.

(3)

MX269018A Basic Settings (Tx mode)


Supports measurements with simple setting

Tx Tests

(2) (1) (2) (3) (4) (5) (6) (7) (8) (9)

(3)

(4)

(5)

(8)

(9)

(10)
*Modulation Analysis display, Filter Setting display see following slides. (6): Demodulation monitor (when USB Audio connected) (7): Demodulation monitor volume (when Monitor Out ON) (8): Averaging (9): Marker (10): Others
Slide 11 MX269022A-J-L-1

(1): Measurement mode (2): Input/output frequency (100 kHz to main frame upper limit) (3): Input/output level (4): Measurement (5): Filter

MX269018A Basic Settings ~Modulation Analysis~


Supports detailed setting for modulation analysis Tx Tests

TX: (4)
[A] [B] [C] [D]

[A] Modulation
Selects input signal modulation method FM: Frequency modulation M: modulation AM: Amplitude modulation

[B] RF Power Set Reference


Adds relative value display as RF power measurement result When RF Power Set Reference is set to On, the measured RF Power at that instant becomes the Reference Power (0 dB) and subsequent displayed RF Power results are referenced to that value.

[C] DCS Code Analysis


Displays DSC code demodulating DCS (Digital Code Squelch) signal (for FM)

[D] Limit Level


Sets RF power lower limit that displays AF measurement results. Cancel the numeric measurement result display of the AF Measure when no input signal.

Slide 12 MX269022A-J-L-1

MX269018A Basic Settings ~Filter~

Tx Tests

Selects filter for demodulated AF signals according to Tx measurement modulation method in Tx mode. Uses them for the extraction and the removal of the tone signal.

TX: (5)
[A] [B] [C] [D]

[A] HPF
Control bandwidth with High Pass Filter (HPF) Off: Do not use HPF 50 Hz: Use HPF in 50 Hz passband 300 Hz: Use HPF in 300 Hz passband 400 Hz: Use HPF in 400 Hz passband

[C] 1st-Filter De-Emphasis


Perform De-Emphasis (for FM) Off: Do not use De-Emphasis Filter On: Use 750 s De-Emphasis Filter

[D] 2nd-Filter
Apply Band Pass Filter (BPF) Off: Do not use BPF CCITT (ITU-T O.41): Use BPF defined by ITU-T O.41 C-Message: Use BPF defined by C-Message

[B] LPF
Control bandwidth with Low Pass Filter (LPF) Off: Do not use LPF 300 Hz: Use LPF in 300 Hz passband 3 kHz: Use LPF 3 kHz passband 15 kHz: Use LPF in 15 kHz passband 20 kHz: Use LPF in 20 kHz passband

Slide 13 MX269022A-J-L-1

MX269018A Rx Mode Screen

Rx Tests

The FM/ M/AM modulated RF signal can be output from the analog signal generator* option.
They included two AF oscillators and DCS(Digital Code Squelch)signal source, and can output the RF signal set them respectively. The wireless equipment can be used for examination confirming the operation by the following combinations. 1. AF + AF = 1kHz audio signal + tone squelch signal 2. AF + DCS = 1kHz audio signal + DCS signal 3. AF(user wave file) = Arbitrary signal User waveform output function
Reads any AF signals from file and supports modulation output. Creating file outputs tone signalling signals, such as DTMF (Dual Tone Multiple Frequency).

In addition, the reception sensitivity of the wireless equipment can be examined by preparing the Audio Analyzer. The wireless equipment is demodulated input RF signal, and outputs the AF signal, and Audio Analyzer measures it.

1.

1. Sets RF signal in MX269018A 2. Outputs RF signal from Analog Signal Generator 3. Outputs AF signal from the wireless equipment

Analog Signal Generator* (option)

2.

3.

*Analog signal generator functions only on the analog measurement software.

Slide 14 MX269022A-J-L-1

MX269018A Rx Mode Screen


Switches to Rx measurement mode to perform Rx tests

Rx Tests

Rx mode display
(MX269018A) [F1: Mode] > RX

(2)

(1): Measurement parameter


Displays set parameters.

(1) (3)

(2): Status message


Displays signal status.

(3): RX Setting window


*Introduced in Basic Settings Displays frequency, level and modulation set value for output RF signal

(4) (5)

(4): Function Menu


Displays functions executed by function keys.

(5): AF Setting window


*Introduced in Basic Settings Displays set value for modulating AF signal.
*Analog signal generator functions only on the analog measurement software.

Slide 15 MX269022A-J-L-1

MX269018A Basic Settings (Rx mode)


Supports measurements with simple setting

Rx Tests

(2) (1) (2) (3) (4) (5) (6) (7) (8)

(3)

(4)

(5)

(9)
*Modulation Analysis display, AF Setting display see following slides. (6): Restarts Tx output for modulation signals (7): Outputs signal modulation ON/OFF (8): Outputs signal ON/OFF (9): Others
*Analog signal generator functions only on the analog measurement software.

(1): Measurement mode (2): Output frequency (3): Output level (4): Measurements (5): AF Signal

Slide 16 MX269022A-J-L-1

MX269018A Basic Settings ~Modulation~


Supports detailed settings for modulation analysis

Rx Tests

RX:(4)
[A] Modulation [A]
Selects output signal modulation method FM: Frequency modulation M: modulation AM: Amplitude modulation

[B]

[B] Signal Output Play Mode


Selects modulation signal continuous output, or output time for wavelength Once: Modulation signal output time for wavelength Repeat: Modulation signal continuous output Method for determining wavelength When using user waveforms: Wavelength of user waveform When not using user waveforms: AF signal tone frequency and DCS setting

*Analog signal generator functions only on the analog measurement software.

Slide 17 MX269022A-J-L-1

MX269018A Basic Settings ~AF Signal Setting (1/2)~


Sets AF signals output from analog signal generator with Rx mode Rx Tests

(5)
[A] [B] [C] [D] [E] [F] [G] [H] [I] [J] [K] [L]

[A], [B] AF1/2 Tone


Selects signal output for AF1/2 signal source
Off: No signal generation On: Generates tone signals User: Generates user file signals (AF1) selected by Select AF1 Wave setting AF2 Tone and Digital Code Squelch setting automatically OFF when selected

[ I ] Digital Code Squelch


Selects signal output for DCS (when FM)

[J] Digital Code Squelch Data


Sets DCS Code (when Digital Code Squelch ON)
000 to 777 (octal, three digits)

[M] [C], [D] AF1/2 Tone Frequency


Sets tone frequency for AF1/2 signal source
20.0 to 40000.0 Hz

[K] Digital Code Squelch Deviation


Sets deviation for DCS signals (when Digital
Code Squelch ON)

[E], [F] AF1/2 Tone Deviation (FM)0.0 to 100000.0 Hz AF1/2 Tone Radian ( M) [L] Device Sets device user waveform saved AF1/2 Tone Depth (AM) Sets Deviation (FM)/Radian ( M)/Depth (AM) [M] Select AF1 Wave
for AF1/2 signals
0.0 to 100000.0 Hz (when FM) 0.0 to 50.0 rad (when M) 0 to 100% (when AM)

Selects Wave file saved in folder of drive specified at Device setting

Supported Wave file formats Supports Wave audio format with following limitation: -Linear PCM file [G] AF Monitor (ADPCM, extended PCM compression format not supported) Monitors combined AF1 Tone and AF2 Tone -Monaural or stereo replay output (when USB Audio connected) (Multiple channels not supported. Use L-Channel for replay when stereo format) [H] Monitor Volume -8 or 16 bit sampling quantization bit (Sets modulation degree for full scale at modulation) Sets output level for AF monitor signals (when -Max 10 s replay time USB Audio connected) -Sampling frequency is one of 44.1 kHz, 48 kHz, 96 kHz *Analog signal generator functions only on the analog measurement software.

Slide 18 MX269022A-J-L-1

MX269018A Basic Settings ~AF Signal Setting (2/2)~


Generates AF signals as follows: Rx Tests

AF signal generation concept


*Analog signal generator functions only on the analog measurement software.

Slide 19 MX269022A-J-L-1

MX269018A Demodulated Voice Output with USB Audio


Demodulation Voice Output

Monitors the audio signal demodulated RF signal from the wireless equipment with USB Audio and speaker etc. on the market.

3.

4.
Speaker (Commercial Item)

2.

1.
1. Outputs AF signal from Audio Generator 2. Outputs RF signal from the wireless equipment 3. Demodulate RF signal in MX269018A 4. Outputs demodulated voice

MX269022A-J-L-1

MX269018A Basic Settings ~Demodulation Voice Output~


Demodulation Voice Output

Outputs demodulated voice signals from USB connector when USB Audio connected to MS2830A

Tx

[A] Monitor Out


Monitor Out ON starts outputting demodulated AF signals running monitor... message displayed at screen top during demodulation monitoring, and all operations except Mode, Monitor Out and Monitor Volume disabled until demodulation monitoring stops.

[B] Monitor Volume


Sets output level for AF signals

[A] [B]

Slide 21 MX269022A-J-L-1

[Merit 1] High-performance Spectrum Analyzer


~Measures F3E out-of-band/proximity spurious for worst-case standard under all conditions~
MS2830A (Opt-062: With Low Phase Noise) SSB Phase Noise Performance Out-of-band spurious measurement example (Frequency: 162MHz; Standard: -80 dBc/10 Hz)

W/O Opt.062 With Opt.062

Standard: -80dBc -114 dBc/Hz Performance

The MS2830A with MS2830A-062 option measures F3E out-of-band/proximity spurious for the worst-case standard under all conditions with excellent SSB phase noise performance (114 dBc/Hz @ 1-kHz offset).
Slide 22 MX269022A-J-L-1

MX269018A Specifications
Items Tx Measurements Common Specification
Target Signal Frequency Range Level Range Analysis Time Carrier Frequency Accuracy Frequency Deviation FM Measurement Demodulation Frequency Range Frequency Deviation Accuracy Residual FM Demodulation Distortion DCS Measurement Function M Deviation M Measurement Demodulation Frequency Range M Deviation Accuracy Residual M Demodulation Distortion AM AM Measurement Demodulation Frequency Range AM Accuracy Residual AM Demodulation Distortion Low Pass Filter High Pass Band Pass De-emphasis Transmit Power Amplitude Measurement Accuracy

Demodulation Monitor

MX269018A Specifications When Input Level proper compared with the input signal is set as long as it doesn't provide separately by each item, the following standards are guaranteed. FM, M, AM signal 300 kHz to 2700 MHz 15 to +30 dBm (at preamp OFF or no preamp) 25 to +10 dBm (preamp ON) 80ms, 300ms(measured DCS) At 18 to 28C, after calibration, (Reference frequency accuracy x carrier frequency + 1)Hz 0 to 20 kHz 20 Hz to 20 kHz 1% of indicated value Residual FM 3.35 Hz rms, SN > 50 dB (at 1.5 kHz deviation, demodulation band: 0.3 to 3 kHz) 0.3% (at demodulation frequency: 1 kHz, Frequency Deviation: 5 kHz, demodulation band: 0.3 to 3 kHz Demodulated result display of Digital Code Squelch 0 to (20 kHz/demodulation frequency [Hz]) rad 20 Hz to 20 kHz 1% of indicated value Residual M 0.01 rad rms (demodulation band: 0.3 to 3 kHz) 1% (demodulation band: 0.3 to 3 kHz) 0% to 98% 20 Hz to 20 kHz 1% of indicated value Residual AM 0.3% (at demodulation band: 0.3 to 3 kHz) 0.3% (at demodulation band: 0.3 to 3 kHz) 300 Hz, 3 kHz, 15 kHz, 20 kHz 50 Hz, 300 Hz, 400 Hz CCITT, C-Message 750 s At 18 to 28C, after calibration, input attenuator 10 dB, when input signal within measurement level range and under Input Level 0.5 dB (at preamp OFF or no preamp) Transmit Power Accuracy based on MS2830A main frame Absolute Amplitude Accuracy. Output demodulated signal to USB audio equipment connected to MS2830A USB terminal

Slide 23 MX269022A-J-L-1

MX269018A Specifications
MX269018A Specifications The function becomes effective when MS2830A-088/188 3.6GHz Analog Signal Generator is installed, or when MS2830A-020/021 Vector Signal Generator and MS2830A-022 Low Power Extension for Vector Signal Generator and MS2830A-029 Analog Function Extension Rx Power Measurement fo The performance applies to MS2830A-088/188 performance or MS2830A-020/021 RF Signal performance when MS2830A-029 is mounted. Frequency Setting Range 100 kHz to 2700 MHz Output Frequency Deviation Setting Range FM Tone Deviation(FM)/Digital Code Squelch Deviation: 0 to 100 kHz Frequency Deviation Setting Resolution 0.1 Hz Frequency Deviation Accuracy 1% of set value (excludes Residual FM) Internal Modulation Signal Source AF Tone Source x 2 Digital Code Squelch Signal Generator Internal Modulation Frequency Range Tone Frequency: 20 Hz to 40 kHz Internal Modulation Frequency Resolution 3 Hz of set value when 0.1 Hz Digital Code Squelch signal used DCS Code Setting Range DCS Code: 000 to 777 (octal, 3 digit) Tone Radian(M): 0 to 50.0 rad (internal modulation frequency x phase deviation) Phase Deviation Setting Range <100 kHz setting range M Phase Deviation Setting Resolution 0.01 rad Phase Deviation Accuracy 1% of set value (excludes Residual M) Internal Modulation Signal Source AF Tone source x 2 Internal Modulation Frequency Range Tone Frequency: 20 Hz to 40 kHz Internal Modulation Frequency Resolution 0.1 Hz Modulation Setting Range AM Tone Depth(AM): 0% to 100% Modulation Setting Resolution 1% Modulation Accuracy 1% of set value (excludes Residual M) Internal Modulation Signal Source AF Tone source x 2 Internal Modulation Frequency Range Tone Frequency: 20 Hz to 40 kHz Internal Modulation Frequency Resolution 0.1 Hz
Items
Max. reverse input

Items

Common Specification

Frequency Range

Output Level Accuracy

Arbitrary Signal Generator

MS2830A-029/088/188/189 Specifications 0Vdc (max.) +18dBm (<20MHz), +30dBm (20MHz) The following specification are added to the specification of the MS2830A-020/021 and MS2830A-022 are installed. MS2830A-088/188/189: 100 kHz to 3.6 GHz MS2830A-029: Lower Limit frequency 100kHz, Upper Limit frequency depends on the vector signal generator installed. When the MS2830A-029/088/188 is installed, At CW and 18 to 28C Output Level p[dBm] -110p-3 3.0 dB typ. (100 kHz f < 250kHz) Available only when MS2830A-189 installed(MS2830A-088/188 installed)

Slide 24 MX269022A-J-L-1

Function Comparison with Old Model MS555B Radio Communication Analyzer


Items Tx Power Anntena VSWR Tx Frequency FM Dev iation Tx Meas Microphone input sensitiv ity Modulation f requency characteristics Distortion S/N Measure Item Tone Frequency SINAD Bandwidth AF Power Rx Meas Demodulation f requency characteristic Distortion S/N Squelch sensitiv ity Power Frequency Counter FM Linear Detector GPIB AF Lev el Meter Sy nthesized Signal Generator Power Meter Monitor demodulated audio signal AF generator Functions Printer Meter Mode Addition modulation of external signal and internal modulation signal Microphone interf ace Tone generator CM coupler Automatic measurement Battery Anritsu MS555B MX269018A a a a a a a a a a a a a a a a a a a a a a a a a a a a a a OPTION OPTION OPTION OPTION*3 *3 Outputs f rom Analog Signal Generator Option a a *1 *1 a a a *2 *2 *2 *2 *2 *2 *2 *2 a a a *2 *2Measure with Audio Analy zer OPTION*3 *3Outputs f rom Analog Signal Generator Option OPTION*4 *4With USB Power MeterUSB OPTION*5 *5 With USB Audio and commercial speaker etc. *1 *1Measure to control external with Audio Generator *2 Measure with Audio Analy zer *2Measure with Audio Analy zer *2 Measure with Audio Analy zer *2Measure with Audio Analy zer *2 Measure with Audio Analy zer *2Measure with Audio Analy zer *2 Measure with Audio Analy zer *2Measure with Audio Analy zer *1Measure to control external with Audio Generator *1 Measure to control external with Audio Generator a Note

Slide 25 MX269022A-J-L-1

Ordering Information (1/2)


The necessary composition is different according to the function to use with MX269018A.
Function of analog measurement software and necessary composition Modulation method of target signal Requires Options Analog measurement software function*1 FM M AM
Carrier Frequency and Carrier Frequency Error RF Frequency Transmit Power RF Power Modulation measurement*2 Deviation(FM), Radian(M), Depth(AM) Result of analyzed DCS Code DCS Code Demodulation Frequency Frequency Effective Value for Level at Demodulation Frequency Level Distortion Ratio of Demodulation Frequency(S/N) Distortion Power vs Time Graph Result TX Measure measurement result display

1., 2., 3. 5. is mandatory

Tx Test

1.Signal Analyzer (MS2830A-040/041/043*) 2.Low Phase Noise Performance (MS2830A-062) 3.Analog Measurement Software (MX269018A)

AF Measure measurement result display

*MS2830A-043 cannot be installed MS2830A-062 and 4. analog signal generator simultaneously. 1.+2.+3.+ 4.Analog Signal Generator (Refer to Slide27 about 4.) 1.+2.+3.+ 5.USB Audio(A0086A) 6.commercial speaker

Rx Test

FM/M/AM Outputs from analog signal generator Demodulate Input RF Signals from wireless equipment and Output Voice from USB connector*3

Demodulated Voice Output

*1:Spurious measurement is also possible by Spectrum analyzer standard measurement function. *2:Deviation(FM), Radian(M), Depth(AM) *3:The voice can be monitored by connecting a speaker etc. on the market with USB Audio.

Slide 26 MX269022A-J-L-1

Ordering Information (2/2)


Ordering Information relationed Analog Measurement Software
Name
3.6GHz Signal Analyzer 6GHz Signal Analyzer Mandatory 13.5GHz Signal Analyzer Mandatory Low Phase Noise Performance Mandatory Analog Measurement Software 3.6GHz Vector Signal Generator 6GHz Vector Signal Generator Low Power Extension for Vector Signal Generator recommend Analog Function Extension for Vector Signal Generator 3.6GHz Analog Signal Generator Vector Function Extension for Analog Signal Generator Mandatory USB Audio MS2830A-043 Model New Order Retrofit MS2830A-040 MS2830A-041 -

Note
9 kHz to 3.6 GHz 9 kHz to 6 GHz 9 kHz to 13.5 GHz Cannot be installed MS2830A-062 and signal generator options simultaneously Cannot retrofit.Improved phase noise performance

MS2830A-062 MX269018A MS2830A-020 MS2830A-120 250 kHz to 3.6 GHz MS2830A-021 MS2830A-121 250 kHz to 6 GHz The lower bound value at the output level is enhanced. MS2830A-022 MS2830A-122 Mandatory to MS2830A-029 Add analog function to MS2830A-020/021 MS2830A-029 Necessary for Rx Test.Refer to the selection condition to below Table MS2830A-022 corresponding is included MS2830A-088 MS2830A-188 Necessary for Rx Test.Refer to the selection condition to below Table MS2830A-189 Add vector function to MS2830A-088/188 A0086A Necessary for Demodulated Voice Output

Option model are decided by the MS2830A which required analog signal generator. Please note that there is a case where an analog SG function cannot be installed for a part of MS2830A composition.
Optional combination necessary for mounting analog signal generator
MS2830A order case Frequency option of MS2830A Installed vector SG SG that can be added Analog SG Analog SG+ Vector SG new order 088*1 020 or 021+022 +029 The case that retrfit analog SG to MS2830A MS2830A-040/041 MS2830A-043 not installed 188*1 188+189*3 MS2830A-020/021 *2 cannot be installed

*1:MS2830A-022 corresponding is included *2: Contact your Anritsu sales representative for details. *3:can select only 3.6GHz Vector SG

Slide 27 MX269022A-J-L-1

Note

Specifications are subject to change without notice.

Anritsu Corporation

5-1-1 Onna, Atsugi-shi, Kanagawa, 243-8555 Japan Phone: +81-46-223-1111 Fax: +81-46-296-1238

Italy

Anritsu S.r.l.

India

U.S.A.

Via Elio Vittorini 129, 00144 Roma, Italy Phone: +39-6-509-9711 Fax: +39-6-502-2425

Anritsu Pte. Ltd. India Branch Office

Anritsu Company

1155 East Collins Blvd., Suite 100, Richardson, TX 75081, U.S.A. Toll Free: 1-800-267-4878 Phone: +1- 972-644-1777 Fax: +1-972-671-1877

Sweden

Anritsu AB

3rd Floor, Shri Lakshminarayan Niwas, #2726, 80 ft Road, HAL 3rd Stage, Bangalore - 560 075, India Phone: +91-80-4058-1300 Fax: +91-80-4058-1301

Borgarfjordsgatan 13A, 164 40 KISTA, Sweden Phone: +46-8-534-707-00 Fax: +46-8-534-707-30

P.R. China (Hong Kong)


Anritsu Company Ltd.
Units 4 & 5, 28th Floor, Greenfield Tower, Concordia Plaza, No. 1 Science Museum Road, Tsim Sha Tsui East, Kowloon, Hong Kong Phone: +852-2301-4980 Fax: +852-2301-3545

Canada

Finland

Anritsu Electronics Ltd.

Anritsu AB

700 Silver Seven Road, Suite 120, Kanata, Ontario K2V 1C3, Canada Phone: +1-613-591-2003 Fax: +1-613-591-1006

Teknobulevardi 3-5, FI-01530 VANTAA, Finland Phone: +358-20-741-8100 Fax: +358-20-741-8111

Brazil

Denmark

P.R. China (Beijing)

Anritsu Eletrnica Ltda.

Anritsu A/S (Service Assurance) Anritsu AB (Test & Measurement)

Anritsu Company Ltd. Beijing Representative Office

Praa Amadeu Amaral, 27 - 1 Andar 01327-010 - Bela Vista - So Paulo - SP - Brazil Phone: +55-11-3283-2511 Fax: +55-11-3288-6940

Kay Fiskers Plads 9, 2300 Copenhagen S, Denmark Phone: +45-7211-2200 Fax: +45-7211-2210

Room 2008, Beijing Fortune Building, No. 5, Dong-San-Huan Bei Road, Chao-Yang District, Beijing 100004, P.R. China Phone: +86-10-6590-9230 Fax: +86-10-6590-9235

Mexico

Russia

Anritsu Company, S.A. de C.V.

Anritsu EMEA Ltd. Representation Office in Russia


Tverskaya str. 16/2, bld. 1, 7th floor. Russia, 125009, Moscow Phone: +7-495-363-1694 Fax: +7-495-935-8962

Korea

Anritsu Corporation, Ltd.

Av. Ejrcito Nacional No. 579 Piso 9, Col. Granada 11520 Mxico, D.F., Mxico Phone: +52-55-1101-2370 Fax: +52-55-5254-3147

8F Hyunjuk Building, 832-41, Yeoksam Dong, Kangnam-ku, Seoul, 135-080, Korea Phone: +82-2-553-6603 Fax: +82-2-553-6604

U.K.

Anritsu EMEA Ltd.

United Arab Emirates


Anritsu EMEA Ltd. Dubai Liaison Office
P O Box 500413 - Dubai Internet City Al Thuraya Building, Tower 1, Suit 701, 7th Floor Dubai, United Arab Emirates Phone: +971-4-3670352 Fax: +971-4-3688460

Australia

Anritsu Pty. Ltd.

200 Capability Green, Luton, Bedfordshire, LU1 3LU, U.K. Phone: +44-1582-433200 Fax: +44-1582-731303

Unit 21/270 Ferntree Gully Road, Notting Hill, Victoria 3168, Australia Phone: +61-3-9558-8177 Fax: +61-3-9558-8255

France

Anritsu S.A.

Taiwan

Anritsu Company Inc.

12 avenue du Qubec, Btiment Iris 1- Silic 612, 91140 VILLEBON SUR YVETTE, France Phone: +33-1-60-92-15-50 Fax: +33-1-64-46-10-65

Singapore Anritsu Pte. Ltd.

7F, No. 316, Sec. 1, NeiHu Rd., Taipei 114, Taiwan Phone: +886-2-8751-1816 Fax: +886-2-8751-1817

Germany

Anritsu GmbH

Nemetschek Haus, Konrad-Zuse-Platz 1 81829 Mnchen, Germany Phone: +49-89-442308-0 Fax: +49-89-442308-55

60 Alexandra Terrace, #02-08, The Comtech (Lobby A) Singapore 118502 Phone: +65-6282-2400 Fax: +65-6282-2533

1103

Please Contact:

Printed on Recycled Paper

No. MX269018A-E-L-1-(1.00)

Printed in Japan

2011-6

MG

S-ar putea să vă placă și