11 with 0 LBA
Page |1
1. First you need to remove the PCB from HDA case and connect it to the HD Doctor Console. Power
supply to the PCB should be on
2. Go to CMD mode, use command “Ctrl+Z” to switch the command line prompt to be F3 T>, as
follow:
5. Then mount the PCB back to HDA case; DO NOT power off or disconnect the PCB from the HD
Doctor Console when doing this step.
6. In CMD mode, under F3 2> prompt, input command “U” and press “Enter” to start spindle motor.
9. Perform a power reset, you will see the drive stayed BUSY before is showing READY now.
10. Finally go to New Feature tab specially designed for Seagate 7200.11, Click “Repair LBA=0” button
to fix the problem that made the drive’s LBA detected with 0.
For Seagate 7200.11 drives with SMART error, users can make use of the “Repair SMART Error” button
to have it fixed.
All the above operations won’t damage the data on the patient drive.