Sunteți pe pagina 1din 5

Both for the V3 and V2 site, the ID_DOG have 15 bits in logical.

There are two switches S1 and S2 physically.


For each bit of S1 and S2, status ON means 0, OFF means 1 S1 bits 18 are mapped ID_DOG logical bits 07; S2 bit 18 are mapped ID_DOG logical bits 815;

V3
FI GURE 1 - CABINET-TOP DIP SWI TCHES

15

14

13

12

11

10

BTS_TYPE

BTS_N O

SLAVE1_ POR T

SLAVE2_ SATE ABIS_POR T POR T

ABIS_TS

The meaning of each bit is explained as follows:


NO 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 SATE ABIS_PORT ABIS_TS Whether to use the satellite Abis link or not O&M port number The O&M LAPD timeslot on the Abis interface SLAVE2_PORT The E1 port of the basic cabinet to connect extended cabinet 2 SLAVE1_PORT The E1 port of the basic cabinet to connect extended cabinet 1 Name BTS_TYPE Meaning BTS TYPE Description 1100: B8018 1101: B8112 1110: M8202 1111: M8204 00: Basic cabinet 01: Extended cabinet 10: Extended cabinet 00: Port E of the basic cabinet 01: Port F of the basic cabinet 10: Port G of the basic cabinet 11: Port H of the basic cabinet 00: Port E of the basic cabinet 01: Port F of the basic cabinet 10: Port G of the basic cabinet 11: Port H of the basic cabinet 0: Common Abis 1: Satellite Abis 00: Port A 01: Port B 10: Port C 11: Port D 000: TS16 001: TS31 010: TS30 011: TS29 100: TS28 101: TS27 110: TS26 111: TS25

BTS_NO

No. of the cabinet of the same site

The number of the E1 port of the basic cabinet to connect the lower-level site cannot be the same as of SLAVE_PORT1 or SLAVE_PORT2. For example, suppose Port F of the basic cabinet connects with the lower-level site, then the values of SLAVE_PORT1

and SLAVE_PORT2 cannot be 01. For example,site1 and site2 are BTS B8018,site2 is the downsite of site1.Both sites use the common Abis,site1 E1 port A connect to BSC,site2 E1 port A connect to site1 port D. The O&M timeslot of site2 is TS31.Then the dip switches are Site1: S1(18) 00000000 S2(18) 00000011 Site2: S1(18) 10000000 S2(18) 00000011

V2
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

INDO OR

SY N

CHAN EL_NO

BTS_NO

SLAV E1_PO RT

SLA VE2_PORT

SATE

ABIS_PORT

ABIS_TS

The meaning of each bit is explained as follows:


NO 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 SATE ABIS_PORT ABIS_TS Whether to use the satellite Abis link or not O&M port number The O&M LAPD timeslot on the Abis interface SLAVE2_PORT The E1 port of the basic cabinet to connect extended cabinet 2 SLAVE1_PORT The E1 port of the basic cabinet to connect extended cabinet 1 Name INDOOR SYN CHANNEL_NO Meaning BTS TYPE Network syn_clock source Port of the monitor Description 0: Indoor 1:Outdoor 0: Get from E1 1: SDH syn_clock 00:RS232 for transparent channel 01:RS422 for transparent channel 10:RS232 for SMC 00: Basic cabinet 01: Extended cabinet 10: Extended cabinet 00: Port C of the basic cabinet 01: Port D of the basic cabinet 10: Port E of the basic cabinet 11: Port F of the basic cabinet 00: Port C of the basic cabinet 01: Port D of the basic cabinet 10: Port E of the basic cabinet 11: Port F of the basic cabinet 0: Common Abis 1: Satellite Abis 00: Port A 01: Port B 10: Port C 11: Port D 000: TS16 001: TS31 010: TS30 011: TS29 100: TS28 101: TS27 110: TS26 111: TS25

BTS_NO

No. of the cabinet of the same site

The number of the E1 port of the basic cabinet to connect the lower-level site cannot be the same as of SLAVE_PORT1 or SLAVE_PORT2. For example, suppose Port D of the basic cabinet connects with the lower-level site, then the values of SLAVE_PORT1 and SLAVE_PORT2 cannot be 01.

For example,site1 and site2 are BTSV2,site2 is the downsite of site1.Both sites use the common Abis, site1 E1 port A connect to BSC,site2 E1 port A connect to site1 port D.The O&M timeslot of site2 is TS31.Then the dip switches are Site1: S1(18) 00000000 S2(18) 00000000 Site2: S1(18) 10000000 S2(18) 00000000 Note To check the DIP switch status in site by signal trace Site Power On Report (157)- last 4 they are in HEX change to BINARY this is for ibsc For V2 leaving last 2 next 4 (Reset site and find this message in signal tracing(OAM))

DIP Configuration for Micro BTS(M8202)

S1

S2

S3
1 OFF 2 OFF 3 ON 4 OFF

Figure 1: For Common Abis (Abis TS 16) S1 S3 S2


1 ON 2 ON 3 ON 4 ON 5 ON 6 OFF 7 OFF 8 OFF

1 OFF 2 OFF 3 ON 4 OFF

Figure 2: For Satellite Abis (Abis TS 25)