The ABLE range of turbine flowmeters offers high accuracy and
reliability. A ferritic, stainless steel rotor revolves within a non Variable Yes No
magnetic housing on the outside of which is located a pick off
Foam
coil containing a permanent magnet. As the rotor blades pass
the tip of the permanent magnet, the reluctance of the magnetic Conductive
circuit is changed and a small ac voltage is induced in the coil.
Non-conductive
The frequency of the ac voltage is proportional to flowrate, and
the total number of pulses produced represents total flow passed ∆ Conductivity
through the meter.
Contact
The electrical signal is a sinusoidal pulse of minimum height Non-contact
50mV peak at lowest flowrate, rising to 800mV peak at max
Clean
flowrate.
Liquids
Dirty
For normal transmission distance pre-amplifiers are not Coating
essential since pulse shaping and conditioning are carried out
in the appropriate electronic readout unit. In cases where heavy Non-Coating
electrical noise is present or where transmission distances are Vapours
over 500 metres, pre-amplifiers of standard or intrinsically safe
design are available as head mounted weatherproof units and
loop powered.
Applications
The flowmeters are suitable for use on lubricating A comprehensive range of sizes from 3/8” upward
and non-lubricating liquids of low to medium viscosity ensures ABLE turbines are configurable for most
and are largely insensitive to density variations, applications.
pressure or temperature fluctuations.
Features
A unique feature of the design is the use of In all cases, the spindle is of tungsten carbide ABLE Instruments & Controls Ltd.
helically milled rotors cut from solid in sizes up with Cobalt binder, and thrust balls of tungsten Cutbush Park, Danehill, Lower Earley,
to 65mm. Bearing bushes are of PTFE/Carbon carbide. Stainless steel ball races are used in Reading, Berks., RG6 4UT UK
Tel: +44 (0)118 931 1188
HY49 or similar, or tungsten carbide depending the smaller sizes.
Fax: +44 (0)118 931 2161
upon nature of metered fluid. Email: sales@able.co.uk
Website: www.able.co.uk
return to
main menu
ABLE Turbine
ABLE Turbine Flowmeter
Normal Applications
Technical Data
Linear Accuracy +/-0.5% over 10:1 range
Flow Range 10:1 standard
Repeatability +/-0.1% of reading Wider ranges possible
Sizing Table
Sanitary Applications
ABLE have a number of specially designed variants for high consequently have designed these flow meters with an absence
accuracy flow measurement and batch control in the liquid food of crevices where bacteria can lodge and breed. The materials of
industries. In the basic design, ABLE were aware of the particular construction also ensures that no corrosive attack occurs when
hygienic requirements of the brewing and diary industries and clean in place solutions are used.
Technical Data
Linear Accuracy +/-0.5% over 10:1 range Flow Range 10:1 standard
Wider ranges possible
Repeatability +/-0.1% of reading
Temperature 120 oC
Response Time <50millisecs for 50% step
change in flowrate Transmission Distance 300 metres max without pre-
amplifiers for low noise
Output Signal Sinusoidal pulses 50mV- environment
800mV peak varying with
flowrate Mounting Attitude Horizontal or vertical (flow
upwards) or inclined
Operating Pressure Twice the pressure drop
across the meter plus vapour Maximum Pressure Limited only by end fittings
pressure of liquid
Sizing Table
Type Flow Range Approx. Linearity Pressure Drop Overall End Fittings Type
Number (Linear) ltr. (Bar) at max. Length RJT ISS Tri-clamp
ltrs/min flow
AHT500 9.0-90 1000 .5% .22 162 1" 1" 1"
AHT1000 18-180 300 .5% .22 162 1" 1" 1"
AHT1500 25-250 240 .5% .20 162 1.5" 1.5" 1"
AHT36 65-650 90 .5% .30 155 2" 2" 1.5"
AHT50 90-900 33 .5% .30 165 2" 2" 2"
AHT65 120-1200 17 .5% .30 216 3" 3" 3"
1 4 5 7
2 3 6
D
A B C D
C
AT 3 51 110 25 82
AT 5 64 110 25 82
AT 7 64 110 25 82
AT 11 85 110 38 84
AT 13 85 110 38 86
B AT 19 114 150 51 89
AT 24 114 150 51 91
AT 32 135 174 64 95
AT 38 150 174 64 98
D
AT 48 180 210 76 103
AT 65 - 258 100 112
C
AT 80 - 316 100 119
AT 100 - 386 167 130
AT 150 - 410 167 155
Dimensions (Sanitary Applications) Allow an extra 50mm height on dimension 'C' for pick off coil
connector.
Type Number A B C
C
AHT 500 162 50 75
AHT 1000 162 50 78
B
AHT 1500 162 50 80
AHT 36 155 64 85
AHT 50 165 75 92
A AHT 65 216 96 98
A length of straight pipe of bore equal to the meter inlet should Varying densities have no appreciable effect on the accuracy of
be provided, preferably 10 diameters in length, and if possible axial flow turbine meters so far as volumetric flow is concerned. If
containing flow straightening vanes at the inlet end. Turbine readout is required in mass flow terms, we can supply density or
meters are sensitive to swirl and any pipe swirl present upstream temperature compensation equipment to automatically correct
may cause a change in meter factor. for density variation. All turbine meters are to some extent
sensitive to viscosity changes and any likely viscosity variation
Strainers should be provided to minimise the risk of damage should be advised at the order stage.
due to small solids in suspension.