Sunteți pe pagina 1din 2

Product Data Submittal

ICS/ICX Standard Skid Packages


Completely Skid Mounted, Piped, and Wired Steam Packages

W A L K W A Y

D
C

5
B

Connections:
1 2 3 4 5 6

1 3

Single Point Electric Single Point Steam Single Point Water Single Point Drain Fuel Inlet (Natural Gas) Flue Outlet

B C
4

Standard single source skid mounted systems


Including boiler, vertical feedwater system with preheat kit, blowoff separator with cooling kit, chemical feed and water softener: - Single point electrical connection (Fused disconnect for fuel-fired boilers) - Single point steam outlet - Single point water inlet - Single point drain - Structural steel base with solid steel deck - Turn-key system

Dimensions
Boiler Model ICS-4 ICS/ICX-6 ICS/ICX-9.5 ICS/ICX-10 ICS/ICX-15 ICS/ICX-20 ICS-25 ICS/ICX-30 ICS-50 ICS-60 Steam Output Tank Model
LB/Hr

Water Softener Model


100% makeup

A. Height (inches)
Not including steam system piping

B. Width (inches) 124 124 124 124 120 132 132 138 156 156

C. Depth (inches) 66 66 66 66 72 72 72 72 84 84

D. Height (inches)
Required for burner removal

138 207 328 345 518 690 863 1,035 1,725 2,070

VT-10 VT-10 VT-10 VT-10 VT-20 VT-20 VT-30 VT-30 VT-50 VT-60

FB-300-900 FB-300-900 FB-300-900 FB-300-900 FB-300-900 FB-300-900 FB-300-900 FB-300-900 FB-600-900 FB-600-900

65 75 83 83 89 93 96 106 106 119

76.25 86.25 96.25 90.25 96.25 100.25 102.25 110.25 118.25 128.25

D
W A L K W A Y

6
C

Connections:
1 2 3 4 5 6

3 1

Single Point Electric Single Point Steam Single Point Water Single Point Drain Fuel Inlet (Natural Gas) Flue Outlet

B C
4

Standard single source skid mounted systems


Including boiler, vertical feedwater system with preheat kit, blowoff separator with cooling kit, chemical feed and water softener: - Single point electrical connection (Fused disconnect for fuel-fired boilers) - Single point steam outlet - Single point water inlet - Single point drain - Structural steel base with solid steel deck - Turn-key system

Dimensions
Boiler Model ICS-4 ICS/ICX-6 ICS/ICX-9.5 ICS/ICX-10 ICS/ICX-15 ICS/ICX-20 ICS-25 ICS/ICX-30 ICS-50 ICS-60 Steam Output Tank Model
LB/Hr

Water Softener Model


100% makeup

A. Height (inches)
Not including steam system piping

B. Width (inches) 124 124 124 124 132 138 144 150 156 156

C. Depth (inches) 66 66 66 66 72 72 72 72 84 84

D. Height (inches)
Required for burner removal

138 207 328 345 518 690 863 1,035 1,725 2,070

HT-10 HT-10 HT-10 HT-10 HT-20 HT-20 HT-30 HT-30 HT-50 HT-60

FB-300-900 FB-300-900 FB-300-900 FB-300-900 FB-300-900 FB-300-900 FB-300-900 FB-300-900 FB-600-900 FB-600-900

71 75 83 83 89 93 96 106 113 113

76.25 86.25 96.25 90.25 96.25 100.25 102.25 110.25 118.25 128.25

Notes:
-- Skid may be disassembled for shipping -- Dimensions and equipment/components subject to change based on options/accessories purchased. Typical components shown -- Not all connections are shown and / or called out -- Overall height does not include any steam system piping outside of the Fulton skid

The heat transfer innovators.


The Fulton Companies
972 Centerville Road, Pulaski, NY 13142 Call: (315) 298-5121 Fax: (315) 298-6390

www.fulton.com
ICS-ICXstdskd-wtrtreat-pds_2012-0613