Salient Features 1.0 General


Source River VDC District Zone Development Region Type of Scheme Gross Head Net Head Design Discharge Installed Capacity Plant Factor Net Annual Generation : : : : : : : : : : : : Tinau Khola Dobhan and Koldanda and Masyam Palpa Lumbini Mid-western Run-of-River 92.5 m 86.95 m 3.13 m3/s 2400 kW 66.37% 13.96 GWh

2.0 Hydrology & Meteorology


Catchment Area Average Annual Precipitation Monsoon Wetness Index Maximum Monthly Rainfall Design 100-yrs Flood Long-term Average Flow Design Discharge (Q40) : : : : : : : 205.6 km2 2453.07 mm 1500 mm 1596.3 mm 733.78m3/s 3.84m3/s 3.13m3/s

3.0 Diversion Weir & Intake


Diversion Weir - Type - Weir height - River bed level - Crest Level of weir - Normal Water level Intake - Type - No of orifice - Size - Crest Level Undersluice - No. of Bays - Width - Height - Crest Level - Highest Flood Level : : : : : : : : : : : : : Uncontrolled ogee crest 6.78m 486.1m 492.844 m 493.0 m Side intake 2 2.0m x 1.0 m 491.3 m 1 Nos. 5.0 m 6.0 m : 485.6 m 497.051 m

Prepared by DK Consult (P.) Ltd.

Tinau-I Small Hydropower Project Palpa District

Feasibility Study Report

4.0 Gravel Trap


-Type -Size -Particles to be settled : : : Continuous Flushing 12.0 m x 3.0 m x 3.1 with FB 10 mm

5.0 Desilting Basin


-Type -Size (L x W x H) -Particle Size to be Settled : : : Dufour (Double-chamber) 55 m x 3.5 m x 4.6 m with FB exceeding 0.2 mm

6.0 Headpond
-Type -Size (L x W x H) -Detention time : : : Modified as outlet zone of desander 11 m x 5.0 m x 4.69 m 60 sec

7.0 Water Conveyance


Connecting pipe - Type - Size - Length - Thickness Headrace Pipe - Type - Size - Length - Thickness Surge Pipe - Type - Size - Thickness - Length Penstock Pipe - Type - Size - Thickness - Length : : : : : : : : : : : : : : : : Low pressure buried pipe 1500 mm ID 320.1 m 6mm thick Mild Steel, Circular 1600 mm ID 2413.35 m 6mm thick Mild Steel 1500 mm ID 8 mm thick 108.27m Mild Steel (1500-1400) mm ID (10-12) mm thick 338.59m

8.0 Surge Tank


- Type - Diameter - Height : : : Circular vertical 4 m ID 16.6 m

9.0 Powerhouse
- Type - Clear Size - Number of Units : : : Surface 29 m x 10.6 m x 7.5 m (L x B x H) 2 Nos.

Prepared by DK Consult (P.) Ltd.

vi

Tinau-I Small Hydropower Project Palpa District - Type of Turbine - Rated Capacity : : Francis 1200 kW

Feasibility Study Report

10.0

Tailrace Canal - Type - Size - Length Gates

: : :

RCC Open Culvert 2.0 m x 1.6 m (B x D) 30 m

11.0

(A) Undersluice Gate:


- Type - Number - Size (B x H) - Mode of Operation : : : : Radial gate 1 No. 5.0 m x 6.0m Mechanical operation

(B) Canal inlet control Gate:


- Type - Number - Size (B x H) - Mode of Operation : : : : Vertical lift 1 Nos. 1.8 m x 1.5 m manual hoisting

(C) Desander inlet control Gate:


- Type - Number - Size (B x H) - Mode of Operation (D) Sand Flushing Gate: - Type - Number - Size (B x H) - Mode of Operation : : : : : : : : Vertical lift 2 Nos. 1.8 m x 2.6 m manual hoisting vertical lift 2 Nos. 0.65m X 0.6 m Manual hoisting

12.0

Trashracks (A) Intake Trashrack: - Type - Number - Size (B x H) - Max.m Spacing of Bars - Inclination (B) Penstock Inlet Trashrack: - Type - Number - Size (B x H) - Max.m Spacing of Bars - Inclination

: : : : : : : : : : :

Inclined 2 Nos. 2 m x 1.0 m (clear opening of intake) 50 mm 15o to vertical Inclined. 1Nos. 2.2 m x 4.0 m 20 mm 15o with vertical Inclined.

(C) Trashrack at Desander:


- Type

Prepared by DK Consult (P.) Ltd.

vii

Tinau-I Small Hydropower Project Palpa District - Number - Size (B x H) - Max.m Spacing of Bars - Inclination : : : : 1Nos. 5.0 m X 2.95 m 25 mm 15o with vertical

Feasibility Study Report

13.0

Transmission Line & Grid Connection -Specification : -Type : -Length : Transformers Step-up Transformer - Rating - Specific.n Generator - Type - Specific.n - No. of Units - Speed - No of Pole Approach Road Existing To be Constructed

33 kV, 3 Phase, 50 Hz DOG ACSR Conductor 6.0 km from Tinau PH to Butwal substation.

14.0

: :

11/132 kV, 13 MVA, 50 Hz 3 Phase, Vector Group Dyn 11, ONAF

15.0

: : : : : : :

Synchronous, 3 Phase 1.41 MVA, 11000 V, 50 Hz, 0.85 pf 2 Nos. 750 RPM 8 Butwal- Palpa black topped road is 100 away from the Powerhouse site. Approx. 100 m of access road to PH site from Existing Butwal-Palpa road and about 3.5km access road from PH to Headworks should be constructed. NRs. 418.197 million US$ 1,572 per kW NRs. 3.72 per kWH 16.96 % 1.42 36 months

16.0

17.0 18.0 19.0 20.0 21.0 22.0

Total Cost of the Project Specific Project Cost Unit Energy Cost Internal Rate of Return (IRR) Benefit Cost Ratio (B/C Ratio) Construction Period

: : : : : :

These values are adopted from Nisi SHPP (3.5 Mw) for reff, as they are comparable to Sisa SHPP (3.89 Mw)