Sunteți pe pagina 1din 3

OGP Safety Zone

11/28/12 6:02 AM

OGP safety alert


Printable version

DIVING DECOMPRESSION CHAMBERS - NOT FIT FOR PURPOSE - RISK OF INJURY TO PERSONNEL AND MULTIPLE FATALITIES
Country: --Location: --Incident Date: --- Time: --Type of Activity: Diving, Subsea, ROV Type of Injury: --Function: ---

A number of Air Decompression chambers have been identified during verification audits that contain serious safety hazards. 1. A decompression chamber was recently found carrying a genuine Identification plate complying with ASME PVHO requirements fitted after construction. This decompression chamber had a subsequent engineering modification with the addition of a medical equipment lock (photo 1), this modification was not carried out by the original manufacturer, and contrary to ASME PVHO requirements the Identification/ Certification plate was not amended.

The engineering quality of the modification was grossly incompatible with the standards required by ASME PVHO (photo 1& 2) No pressure test had ever been conducted on the external door of the medical lock. Should the Medical lock have been used as designed, the lack of engineering quality increased the probability of catastrophic failure and explosive decompression, resulting in the death of the chamber occupants This Chamber had been owned by various Diving Contractors and equipment suppliers, none of which identified the modification
2. A number of Decompression chambers manufactured under ASME PVHO standard have been identified that contain corrosion grossly in excess of the maximum tolerance required by ASME PVHO standard and with the subsequent risk of pressure vessel rupture and death of the occupants.

The location of the corrosion is between the 5 and 8 o'clock position on the outer lock to inner lock shell. (Sketch 1 & 2, & photo 3) This corrosion is the product of poor maintenance during the working life of the chamber In many cases observed, erroneous actions were taken to repair this corrosion. These include, lacquering with successive layers of paint, filling the corrosion area with packer material or weld bead material and grinding flush prior to repainting.

What Went Wrong?:


Failure to maintain equipment to the manufacturer's standards
Failure to maintain records of design, construction, modification and testing

http://info.ogp.org.uk/safety/SafetyAlerts/alerts/Detail.asp?alert_id=246

Page 1 of 3

OGP Safety Zone

11/28/12 6:02 AM

Failure of inspection auditors to identify non compliance and corrosion.

Corrective Actions and Recommendations:


Verify Decompression chambers are designed, constructed, tested and maintained to a recognised standard Check all documentation is available for the chamber Verify with the issuing authorities that the documentation is accurate Inspect chambers for compliance and corrosion hotspots

http://info.ogp.org.uk/safety/SafetyAlerts/alerts/Detail.asp?alert_id=246

Page 2 of 3

OGP Safety Zone

11/28/12 6:02 AM

safety alert number: 246 OGP Safety Alerts http://info.ogp.org.uk/safety/ Disclaimer Whilst every effort has been made to ensure the accuracy of the information contained in this publication, neither the OGP nor any of its members past present or future warrants its accuracy or will, regardless of its or their negligence, assume liability for any foreseeable or unforeseeable use made thereof, which liability is hereby excluded. Consequently, such use is at the recipient's own risk on the basis that any use by the recipient constitutes agreement to the terms of this disclaimer. The recipient is obliged to inform any subsequent recipient of such terms. This document may provide guidance supplemental to the requirements of local legislation. Nothing herein, however, is intended to replace, amend, supersede or otherwise depart from such requirements. In the event of any conflict or contradiction between the provisions of this document and local legislation, applicable laws shall prevail.

http://info.ogp.org.uk/safety/SafetyAlerts/alerts/Detail.asp?alert_id=246

Page 3 of 3

S-ar putea să vă placă și