DESCRIPTION OF APPARTUS: The apparatus consists of a guarded hot plate and cold plate. A specimen whose thermal conductivity is to be measured is sand witched between the hot and cold plate. Both hot plate and guard heaters are heated by electrical heaters. A small trough is attached to the cold plate to hold coolant water circulation. A similar arrangement is made on the other side of the heater as shown in the figure. Thermocouples are attached to measure temperature in between the hot plate and specimen plate, also cold plate and the specimen plate. A multi point digital temperature indicator with selector switch is provided to note the temperatures at different locations. An electronic regulator is provided to control the input energy to the main heater and guard heater. An ammeter and voltmeter are provided to note and vary the input energy to the heater. The whole assembly is kept in an enclosure with heat insulating material filled all around to minimize the heat loss. SPECIFICATION: Thickness of specimen = 2.5mm Diameter of specimen (d) = 20cm
MODEL CALCULATIONS:
FORMULA USED: Since the guard heater enables the heat flow in uni direction q = KA dT/dx Where A = surface area of the test plate considered for heat flow = m2 dx = thickness of the specimen plate = m dt = average temperature gradient across the specimen = c q = Q/2 since the heat flow is from both sides of the heater = watts Tavg1 = T1 + T2 / 2 ; Tavg2 = T3 +T4 / 2 Q = V.I. Watts Q = K1 A. dT / dx (for lower side) Q = K1. d2/4 (Tavg1 T5)/dx Where dx = 2.5mm = 0.0025m Diameter of specimen
d = 20cm = 0.2m Q = K2 d2/4 . (Tavg2 T6)/dx ( for upper side) KAvg = (K1 + K2 )/ 2 PROCEDURE: 1. Connect the power supply to the unit. Turn the regulator knob clockwise to power the main heater to any desired value. 2. Adjust the guard heaters regulator so that the main heater temperature is less than or equal to the guard heater temperature. 3. Allow water through the cold plate at steady rate. Note the temperatures at different locations when the unit reaches steady state. The steady state is defined, as the temperature gradient across the plate remains same at different time intervals. 4. For different power inputs is in ascending order only the experiment may by repeated and readings are tabulated as below.
(Characteristic length) PROCEDURE: 1. Connect the three pin plug to a 230V, 50Hz, 15A power and switch on the unit. 2. Keep the thermocouple selector switch in first position. 3. Turn the regulator knob to clockwise and set the power to the heater to any desired value by looking at the voltmeter and ammeter. 4. Allow the unit to stabilize. 5. Switch ON the blower. 6. Set the airflow rate to any desired value looking at the difference in U tube manometer limb levels. 7. Note down the temperatures indicated by temperature indicator. 8. Repeat the experiment by a. heater constant. b. rate constant. Varying the power input to the heater and keeping the air flow Varying the airflow rate and keeping the power input to the
9. Tabulate the readings and calculate for different conditions. 10. After all the experiment is over, put off the blower switch, turn the energy regulator knob anti clockwise, put off the main switch and disconnect the power supply.
Sl.No.
Manometer reading h1 h2
Amb. temp. T6
CALCULATIONS :
Volume of air flowing through the duct Vo Where cd g ha a1 a2 h = cd a1a2 2gha / a12 a22 = co-efficient of orifice = 0.6 = gravitational constant = 9.81 m/sec2 = heat of air = (lw /la)h = area of the pipe. = area of the orifice. = manometer differential head.
Velocity of air in the duct = Vo / (W X B) Where W D = width of the duct. = breadth of the duct.
REYNOLDS NUMBER OF AIRFLOW: Reynolds number Re = (L X Va X Pa) / a Where Va Pa a L = Velocity of air in the duct. = density of air in the duct. = Viscosity of air at to C. = length of fin.
ka
actual heat transferred by the fin (heat which been transferred if entire fin where at the base temperature) = Tan Hyperbolic ML/ML Where, h L M P A kb = = = = = = heat transfer co-efficient length of the fin hp/(kb X A) perimeter of the fin ( X dia of the fin) cross sectional area of the fin. thermal conductivity of brass rod.
would have
Temperature distribution = Tx = [cosh M (L-X) /cosh ML (To - Ta)] + Ta X = distance between thermocouple and heater.
EVALUATION OF THE HEAT TRANSFER CO-EFFICIENT (h) Natural convection (blower off) Nuav = (hd)/k = 1.1 (Gr Pr)1/6 for 1/10 < Gr Pr < 104 Nuav = 0.53 (Gr Pr)1/4 for 104 < Gr Pr < 109 Nuav = 0.13 (Gr Pr)1/3 for 109 < Gr Pr < 1012 Where Nuav = average Nusselt number = (hD) / k D K = = Dia. of fin thermal conductivity of air. D 3 / r2
PIN-FIN
V 135 A 0.6 T1 67 T2 61 T3 59 T4 56 T5 49 T6 47 T7 46 T8 29 h1cm h2cm 75 15.5
Vol. of airflow thro duct = Q = Cd a1 a2 2gh / a12 - a22 a1 = /4 (0.04)2 = 1.256 X 10-3 a2 = /4 (0.02)2 = 3.14 X 10-4 h =w / a ( 0.155 0.075) = 68.96m Q = 8.704 X 10-6 / 1.216 X 10-3 = 7.158 X 10-3 m3/sec Velocity of air flow thro duct = Q/A A = Length X Breadth of the duct = 0.15 X 0.1 = 0.015 m2 Velocity = 0.477 m/sec Re = D / = D = Length of the Fin = 0.145 = 0.145 X0.477/ 17.95 X 10-6 = 3853
= 5.54 w/m2 o c M = hp / kb A = 5.54 X 0.0376 / 110.7 X = 4.078 kg/m Fin efficiency Temp. distribution T2 T3 T4 T5 T6 T7 = Tan G ML/ML =0.89 = 89o = [cosh M (L-X) /cosh ML (To - Ta)] + Ta = [cosh M (0.022) /1.17997 (67 - 29)] 0.85088(38) = = = = = = 61.33o c 0.8588(32) + 29 = 56.22o c 0.8588(30) + 29 = 54.5o c 0.8588(27) + 29 = 51.9o c 0.8588(20) + 29 = 46o c 0.8588(18) + 29 = 44o c /4(0.012)2
RESULT : The efficiency of the fin is found to be ---------------------Temperature at x = 20mm, T20 = ------------Temperature at x = 40mm, T40 = ------------Temperature at x = 60mm, T60 = ------------Temperature at x = 80mm, T80 = -------------
AIM: To measure the emissivity of the test plate surface. DESCRIPTION OF APPARATUS : An ideal black surface is one, which absorbs the radiation falling on it. Its reflectivity and transivity is zero. The radiation emitted per unit time per unit area from the surface of the body is called emissive power. The emissive power of a body to the emissive power of black body at the same temperature is known as emissivity of that body. For a black body absorptivity is 1 and by Kirchaffs law its emissivity is also 1. Emissivity depends on the surface temperature and the nature of the surface. The experimental set up consists of two circular aluminum plates identical in size and are provided with heating coils at the bottom. The plates or mounted on thick asbestos sheet and kept in an enclosure so as to provide undisturbed natural convection surroundings. The heat input to the heaters is varied by two regulators and is measured by an ammeter and voltmeter. The temperatures of the plates are measured by Ir/Con thermocouples. Each plate is having three thermocouples; hence an average temperature may be taken. One thermocouple is kept in the enclosure to read the chamber temperature. One plate is blackened by a layer of enamel black paint to form the idealized black surface whereas the other plate is the test plate. The heat dissipation by conduction is same in both cases. SPECIFICATION : Diameter of test plate and black surface = 150mm PROCEDURE: a) b) Connect the three pin plug to the 230V, 50Hz, 15 amps main supply and switch on the unit. Keep the thermocouple selector switch in first position. Keep the toggle switch in position 1. By operating the energy regulator 1 power will be fed to black plate. Now
keep the toggle switch in position 2 and operate regulator 2 and feed power to the test surface. c) d) e) f) g) Allow the unit to stabilize. Ascertain the power inputs to the black and test surfaces are at set values. i.e. equal. Turn the thermocouple selector switch clockwise step by step and note down the temperatures indicated by the temperature indicator from channel 1 to 7. Tabulate the readings and calculate. After the experiment is over turn both the energy regulators 1 & 2. For various power inputs repeat the experiment. TABULATION : Black body Polished body Emmissivity Average Average Chamber temperature temperature Sl.No. Temp. Temp. Temp. T4 T5 T6 T7 Tb T1 T2 T3 Tp
CALCULATIONS: Temperature of the black body in absolute unit T ba Temperature of the polished body in absolute unit T pa Temperature of the chamber in absolute unit T ca Emissivity p = b X T4 ba - T4 ca / T4 pa - T4 ca Where b, emissivity of black body which is equal to 1. Emmissivity apparatus : V 100 A 0.4 T1 89 T2 92 T3 90 T4 40 T5 79 T6 80 T7 81 = T b + 273 = T p + 273 = T 7 + 273
Avg. temp. of polished plate = 363.3o k = (89 + 92 + 90 / 3) + 273 Avg. temp. of Black plate = (79 + 80 + 81 / 3) + 273 = 353 o k. Chamber temp. = 40 + 273 = 313 o k Power Input Q = pA (Tp4 - Ta4) = bA (Tb4 - Ta4) Since the power input is same for both heaters and area of radiating surface (A) is also same, knowing the b =1. The emmissivity of polished surface p = b (Tb4 - Ta4) / (Tp4 - Ta4) = 3534 - 3134 / 3634 - 3134
= 5.9 X 109 / 7.76 X 109 = 0.76 RESULT : Emissivity of the specimen is found to be ---------------
TABULATION:
SPECIFICATION:
1. Thermal conductivity Of sheet asbestos Thickness Thickness 3. Dia. Of plates = 0.116 W/MK = 6mm = 0.052W/MK = 10mm = 300mm
PROCEDURE
1. Turn the screw rod handle clockwise to tighten the plates. 2. Switch on the unit and turn the regulator clockwise to provide any desired heat input. 3. Note the ammeter and voltmeter readings. 4. Wait till steady state temperature is reached. 5. (The steady state condition is defined as the temperature gradient across the plates does not change with time.) 6. When steady state is reached note temperatures and find the temperature gradient across each slab. 7. Since heat flow is from the bottom to top of the heater the heat input is taken as Q/2 and the average temperature gradient between top and bottom slabs from the heater to be taken for calculations. Different readings are tabulated as follows.
CALCULATION:
Now the resistance ( R ) offered by individual plates for heat flow. R1 = L1/AK1 R2 = L2 / AK2 R3 = L3/AK3 Where A = Area of the plate K = Thermal Conductivity L = Thickness of the plate. Knowing the thermal conductivities Q = (T4 T1)/R =(T2 T1)/R1=(T3 T2)/R2=(T4 T3)/R3
COMPOSITE WALLS
V A 182 0.5 T1 T2 T3 T4 T5 T6 76 75 72 71 66 67 heater ms 71.5 ashess 66.5 Area of the plate / 4 (0.3)2 = 0.07m2 T7 T8 50 51 wood 50.5 Time for 1 Rev. E.M
Resistance of Asbestos (R1) = L1 /A1K1 = 0.005/0.07 X 69 X 10-3 =1.03 Resistance of Wood (R2) = L2/A2K2 = 0.008/0.07 X 52 X 10-3 = 2.19 Heat flow Q1 = Temp. across Asbestos / R1 = 5/1.03 =4.85 Watts Q2 = Temp. across Wood / R2 = 16/2.19= 7.3 Watts As per electrical anology Q1 = Q2 = Q3 Total Resistance R3 = 1.03 + 2.19 = 3.22 Q3 =(Temp. across Asbestos + Wood) / R3 = 21/3.22 = 6.521 As we have find the inside heat transfer co-efficient for heat flow from heater to MS plate, we consider only the second and third layer.
RESULT:
The rate of heat transfer through different materials are found to be a. MS section b. Wood section c. Asbestos section = ------------- W = ------------- W = --------------W
5. FREE CONVECTION
Date: AIM: To find the heat transfer coefficient under natural convection environment. DESCRIPTION OF APPARATUS: Convection is a mode of heat transfer where by a moving fluid transfers heat from a surface. When the fluid movement is caused by density differences in the fluid due to temperature variations, it is called FREE or NATURAL CONVECTION. This apparatus provides students with a sound introduction to the features of free convection heat transfer from a heated vertical rod. A vertical duct is fitted with a heated vertical placed cylinder. Around this cylinder air gets heated and becomes less dense, causing it to rise. This in turn gives rise to a continuous flow of air upwards in the duct. The instrumentation provided gives the heat input and the temperature at different points on the heated cylinder. SPECIFICATION: Length of cylinder = 50 cm PROCEDURE: 1. Switch on the unit and adjust the regulator to provide suitable power input. 2. Allow some time for the unit to reach steady state condition. 3. Note the temperature of inlet air, outlet air and temperatures along the heater rod. 4. Note ammeter and voltmeter readings. 5. For different power inputs the experiments may be repeated. The readings are tabulated as below: -
FORMULA USED: The power input to heater = V X A = hAt Where A = Area of heat transfer = dl D = Dia. Of heater rod = 40mm L = Length of heater rod = 500mm t= Avg. temp. Of heater rod Avg. temp. of air.
THEORETICAL METHOD
Using free convection correlations for vertical cylinders. Nu = hl / K = 0.53(GrPr)1/4 for GrPr < 105 Nu = hl / K = 0.56(GrPr)1/4 for 105 < GrPr < 108 Nu = hl / K = 0.13(GrPr)1/3 for 108 < GrPr < 1012 Characteristic length is the height of the cylinder (l) K = Thermal conductivity of air P = Prandtl number of air Gr = gl3 t / 2 = 1 / Mean temp. of air + 273 K The properties of air at mean temperature = (T1+T2+T3++T8 )/ 8 Hence h can be evaluated. NATURAL CONVECTION: V A T10c T20c T30c 85 0.38 30 55 60 = 1/51.8 + 273 = 3 X 10-3 Gr = gl3 t / 2 = 3.05 X 108 where l = length of heater = Kinematic viscosity of air at mean temp. Pr = from data book for air mean temp. = 0.698 Hence GrPr = 2.13 X 108 Hence using free convection correlations Nu = hl / K = 0.13 (GrPr)1/3 where K is the Thermal conductivity of air at mean temp. t = [(T2 + T3 + T4 + T5) / 4 ] [(T1+F6)/2] = 3 X 10-3 X 9.81 X (0.5)3 X 26.75 / (17.96 X 10-6)2
T40c 65
T50c 63
T60c 38
= 72.82 Overall heat transfer co-efficient h = 72.82 X 28.26 X 10-3 / 0.5 = 4.11 w/m2-0c
6. FORCED CONVECTION
AIM: To find the heat transfer coefficient under forced convection environment. DESCRIPTION OF APPARATUS: The important relationship between Reynolds number, Prandtl number and Nusselt number in heat exchanger design may be investigated in this self contained unit. The experimental set up (see sketch) consists of a tube through which air is sent in by a blower. The test section consists of a long electrical surface heater on the tube which serves as a constant heat flux source on the flowing medium. The inlet and outlet temperatures of the flowing medium are measured by thermocouples and also the temperatures at several locations along the surface heater from which an average temperature can be obtained. An orifice meter in the tube is used to measure the airflow rate with a U tube water manometer. An ammeter and a voltmeter is provided to measure the power input to the heater. A power regulator is provided to vary the power input to heater. A multi point digital temperature indicator is provided to measure the above thermocouples input. A valve is provided to regulate the flow rate of air.
TABULATION: Sl Inlet temp. of air Outlet temp. of air Temperatures along the duct No
PROCEDURE: 1. Switch on the mains. 2. Switch on the blower. 3. Adjust the regulator to any desired power input to heater. 4. Adjust the position of the valve to any desired flow rate of air. 5. Wait till steady state temperature is reached. 6. Note manometer readings h1 and h2. 7. Note temperatures along the tube. Note air inlet and outlet temperatures 8. Note volt meter and ammeter reading. 9. Adjust the position of the valve and vary the flow rate of air and repeat the experiment. 10. For various valve openings and for various power inputs and readings may be taken to repeat the experiments. The readings are tabulated
The heat input Q = h A L M T D = m cp (temp. of tube temp. of air) M = mass of air. cp = specific heat of air. 1n x (Avg. temp of tube outlet temp. of air) (Avg. temp of tube inlet temp. of air) H= heat transfer co-efficient. A = area of heat transfer = T1d1 From the above the heat transfer co-efficient h can be calculated. experimentally determined values may be compared with theoretical values. Calculate the velocity of the air in the tube using orifice meter / water manometer. The volume of air flowing through the tube (Q) = (cd21222gh0 ) / (a12 a22 ) m3 / sec. ho = heat of air causing the flow. = (h1 h2)w/ a h1 and h2 are manometer reading in meters. These LMTD=(Avg Temp Of tube outlet air temp) (Avg. temp of tube inlet air temp.)
a 1= area of the tube. a2 = area of the orifice. Hence the velocity of the air in the tube V = Q / a1 m/sec heat transfer rate and flow rates are expressed in dimension less form of Nusselt number and Reynolds number which are defined as Nu = h D/k D = Dia. Of the pipe V = Velocity of air K = Thermal conductivity of air. The heat transfer co-efficient can also be calculated from Dittus-Boelter correlation. Nu = 0.023 Re 0.8 Pr 0.4 Where Pr is the Prandtl number for which air can be taken as 0.7. The Prandtl number represents the fluid properties. The results may be represented as a plot of Nu exp/ Nu corr. Vs Re which should be a horizontal line. Re = Dv/
FORCED CONVECTION
V 50 A 1 T1 35 T2 42 T3 45 T4 46 T5 47 T6 38 h1cm h2cm 9 19 Avg. Temp. Of heater = (42 + 45 + 46 + 47) / 4 = 45oC Avg. Temp. of Air = (35 + 38) / 2 = 36.5oC Vol. Of air flow Q = (Cda1a22gh) / (a12 a22 ) Cd = 0.6 A1 = /4 (0.04)2 = 1.256 X 10-3 A2 = /4 (0.02)2 = 3.14 X 10-4 H = water/air (h1 h 2) mtrs = 1000/1.16 (0.1) = 86.2 mtrs. Q = [0.6 X 1.256 X 10-3 X 3.14 X 10-4 (2 X 9.81 X 4)] / (1.256X10-3)2 (3.14X10-4)2 = 9.73 X 10-6 / 1.256 X 10-3 = 8.002 x 10-3
Velocity of air flow = Q / a1 = 6.37 m/sec Re = D/ r = 15023 R = kinematic viscosity at mean temp. Using forced convection correlation Nu = hD /k = 0.023 Re 0.8 Pr 0.4 Pr at mean temp = 0.699 = 0.023(15023)0.8 (0.699)0.4 hD/k = 43.7 k= Thermal conductivity of air at mean temp h = 43.7 X 28.56 X 10-3 / (0.04) = 31.2 w/mc.
AIM: To find Stefan-Boltzman constant. DESCRIPTION OF APPARATUS: Stefan Boltzman law which establishes the dependence of integral hemispherical radiation on temperature. We can verify this phenomenon in this unit. The experimental set up consisting of concentric hemispheres with provision for the hot water to pass through the annulus. A hot water source is provided. The water flow may be varied using the control valve provided, there by to control the hot water temperature. A small disk is placed at the bottom of the hemisphere, which receives the heat radiation and can be removed (or) refitted while conducting the experiment. A multi point digital temperature indicator and thermocouples (Fe/Ko) are provided to measure temperature at various points on the radiating surface of the hemisphere and on the disc. SPECIFICATIONS: 1. Mass of the disc 2. Dia. of the disc 3. Material of the disc 4. Cp = 0.005 kg. = 0.020 m. = copper = 381 J/KgK
Td
PROCEDURE: 1. Allow water to flow through the hemisphere. Remove the disc from the bottom of the hemisphere. temperature. 2. Note down the temperatures T1, T2 and T3. The average of these temperatures is the hemisphere temperature (Th). 3. Refit the disc at the bottom of the hemisphere and start the stop clock. 4. The raise in temperature T4 with respect to time is noted. Also note down the disc temperature at T4 when steady state is reached (Td). Switch on the heater and allow the hemisphere to reach a steady
To find the thermal conductivity of different insulating material. DESCRIPTION OF APPARATTUS : The insulation defined as a material, which retards the heat flow with reasonable effectiveness. Heat is transferred through insulation by conduction, convection and radiation or by the combination of these three. There is no insulation, which is 100% effective to prevent the flow of heat under temperature gradient. The experimental set up in which the heat is transferred through insulation by conduction is under study in the given apparatus. The apparatus consisting of a rod heater with asbestos lagging. The assembly is inside as MS pipe. Between the asbestos lagging and MS pipe saw dust is filled. The set up as shown in the figure. Let r1 be the radius of the heater, r2 be the radius of the heater with asbestos lagging and r3 be the inner radius of the outer MS pipe. Now the heat flow through the lagging materials is given by Q = K1 2 L(t) / (In(r2)/r1) or = K2 2 L(t) / (In(r3)/r2) Where t is the temperature across the lagging. K1 is the thermal conductivity of asbestos lagging material and K2 is the thermal conductivity of saw dust. L is the length of the cylinder. Knowing the thermal conductivity of one lagging material the thermal conductivity of the other insulating material can be found.
TABULATION : Heat temperature S.No 1 2 3 Asbestos Sawdust temperature 7 8 avg Volts Amps temperature avg 4 5 6 avg
SPECIFICATION: Diameter of heater rod Diameter of heater rod with asbestos lagging Diameter of heater with asbestos lagging and saw dust The effective length of the above set up of cylinders PROCEDURE: 1. 2. 3. Switch on the unit and check if all channels of temperature indicator showing proper temperature. Switch on the heater using the regulator and keep the power input at some particular value. Allow the unit to stabilize for about 20 to 30 minutes. Now note down the ammeter, voltmeter reading which given the heat input. 4. Temperatures 1,2 and 3 are the temperature of heater rod, 4,5 and 6 are the temperatures on the asbestos layer, 7 and 8 are temperatures on the sawdust lagging. 5. The average temperature of each cylinder is taken for calculation. The temperatures are measured by thermocouple (Fe/Ko) with multi point digital temperature indicator. 6. The experiment may be repeated for different heat inputs. The readings are tabulated as below: CALCULATIONS : Lagged Pipe: V 90 A 0.4 T1 108 T2 117 T3 89 T4 51 T5 59 T6 53 T7 41 T8 41 = 20mm = 40mm = 80mm = 500mm
Avg. Temp. of heater Avg. Temp. of Asbestos lagging Avg. Temp. of sawdust lagging
q k1
= k1 2 l (t) / ln (r2 / r1) = Thermal conductivity of asbestos lagging from data look at = 110.5 X 10-3 w/mo k. = 54o c
r2 r1 l
= Radius of the asbestos lagging = 20 = Radius of the heater = 10 mm = Length of the heater = 0.5 mtrs.
Substituting these values q = 110.5 X 10-3 X 2 X X 0.5 X Substituting this value of q to find the thermal conductivity of sawdust. 25.19 = k2 X 2 X X l X 13.3 / ln (r3/r2) k2 = 25.19 X ln (40/20) / 2XX13.3X8. = 0.417
A simple heat exchanger of transfer type can be in the form of a tube arrangement. One fluid flowing through the inner tube and the other through the annulus surrounding it. The heat transfer takes place across the walls of the inner tube.
TABULATION :
FOR COUNTER FLOW Time for 1 Lit. of Time for 1 Lit. of Sl.No. T1 Hot Water (sec) cold water (sec)
T2
T3
T4
The apparatus consists of a concentric tube heat exchanger. The hot fluid i.e. hot water is obtained from an electric geyser and flows through the inner tube. The cold fluid i.e. cold water can be admitted at any one of the ends enabling the heat exchanger to run as a parallel flow apparatus or a counter flow apparatus. This can be done by operating the different valves provided. Temperatures of the fluids can be measured using thermometers. Flow rate can be measured using stop clock and measuring flask. The outer tube is provided with adequate asbestos rope insulation to minimize the heat loss to the surroundings. SPECIFICATIONS: Length of the heat exchanger Inner copper tube ID OD Outer GI tube ID PROCEDURE: 1. Connect water supply at the back of the unit. The inlet water flows through geyser and inner pipe of the heat exchanger and flows out. = = = 12mm 15mm 40mm
Also the inlet water flows through the annulus gap of the heat exchanger and flows out. 2. For parallel flow open valve V2 , V4 and V5. For counter flow open valve V3, V1 and V5. 3. Control the hot water flow approximately 2 lit./min. and cold water flow approximately 5 lit./min. 4. Switch ON the geyser. Allow the temperature to reach steady state. 5. Note temperatures T1 and T2 (hot water inlet and outlet temperature respectively).
6. Under parallel flow condition T3 is the cold-water inlet temperature and T4 is the cold water outlet temperature.Note the temperatures T3 and T4.Under counter flow condition T4 is the cold-water inlet temperature T3 is the cold-water outlet temperature. 7. Note the time for 1 liter flow of the hot and cold water. Calculate mass flow rate Kg/sec. 8. Change the water flow rates and repeat the experiment.
CALCULATIONS:
Refer drawing and find LMTD (tm) = t1 to / ln (t1 / to) Please not t1 and to to be calculated as per drawing for Parallel flow and Counter flow. Qh = A U L M T D Hence the overall Heat transfer co-efficient
U = qh / A L M T D Where qh = mh cp (Thi Tho) cp = specific heat of water (j/kgc) A = Outer area of hot water pipe. Mh = mass of hot water (kg/sec) Effectiveness of Heat exchanger = Actual heat transfer/ Max. possible heat transfer = (tco tci) / (thi tci) THEORETICAL METHOD: The overall Heat transfer co-efficient 1/U = (1/ho) + (1/h1) Neglecting the thickness of inner tube and film resistance where ho and h1 are the coefficient of heat transfer of hot and cold side respectively. h1 = Inside Heat transfer co-efficient (from hot to inner surface of the inner tube) ho = Out side heat transfer co-efficient (from outer wall of the inner tube to the cold fluid). Re = hot water flow = D / = Velocity of hot water. Knowing the mass flow rates () may be calculated for hot and cold water. Nu = 0.023 (Re)0.8 (Pr)0.3 = (hiD) /K K = Thermal conductivity of water. In a similar manner ho can also be calculated. However for finding ho the
characteristic dia. Is taken as the annulus which is given by the (ID of the outer pipe OD of outer pipe). Hence, U the overall Heat transfer co-efficient is evaluated. Parallel flow / Counter flow Heat exchanger.
Parallel Flow
Cold Water Inlet T1 Thi 37 Inlet T3 Tci 28 Outlet T4 Tco 31 24 Sec. water flow 1 lit.
for Water
LMTD = (Thi Tci) (Tho Tco) / ln (Thi Tci / Tho Tco) = (40 28) (37 31) / ln 40 28 / 37 31 Heat input qb = A.U LMTD Hence the overall heat transfer co-efficient, U = qb / A L M T D qb = mb cb (Thi Tho) = 1/24 X 4.178 X 3 = 0.522 kw U = 0.522 / K
Theoretical Method: 1/U = 1/hi + 1/ho hi = Volume of hot water flow = (1/24) / 1000 m3 / sec. = 4.166 X 10-5 m3 / sec. Velocity of hot water flow = 4.166 X 10-5 / /4(0.012) 2 m/sec = 0.368 m/sec Re = D / = 0.012 X 0.368 / 0.75 X 10-6 = 5888. Using the heat transfer correlation Nu = 0.023 (Re)0.8 (Pr)0.3 k = Thermal conductivity of water = hiD/k
hi = 39.79 X 605 X 10-3 / 0.012 = 2006 ho = Volume flow rate of Cold water (1/21) / 1000 m3 / sec. Qc = 4.76 X 10-5 m3 / sec. Velocity of Cold water flow Vc = Qc / Ac Ac = Annulus area i.e. /4(0.04)2 - /4 (0.015)2 = 1.08 X 10-5
Vc = 4.76 X 10-5 / 1.08 X 10-3 = 0.044 m/sec Re = D / = (0.04 0.015) X 0.044 / 0.75 X 10-6
= 1466 Since the flow is not turbulent we can using the following equation. Nu = 0.37(Re)0.6 (Pr)0.33 hoDc / k = 51.5 h o = 1247. 1/U = 1/hi + 1/ho = 1/2006 + 1/1247 U = 769 W/m2 o c. This procedure is repeated for counter flow heat exchanger, however care to be taken while calculating LMTD. Dc = Annulus dia. (0.04 0.015) = 0.025
RESULT : (i) Parallel flow Overall heat transfer coeffient by theoretical method ----------- W/ m2 K Overall heat transfer coeffient by prctical method (i) Counter flow Overall heat transfer coeffient by theoretical method ----------- W/ m2 K Overall heat transfer coeffient by prctical method ----------- W/ m2 K ----------- W/ m2 K