Sunteți pe pagina 1din 7

Environmental

Odour Control
www.anotec.com.au

Diffuse & Point


Source Emissions
Sewage Treatment,
Landfill, Site
Remediation

Anotec Pty Limited


PO Box 292 | Botany | NSW | 1455
Tel: (02) 9700 1222 | Fax: (02) 9700 1771
Anotec Pty Limited
Email: service@anotec.com.au
Tel: (02) 9700 1222 | Fax: (02) 9700 1771 | Email: service@anotec.com.au
Anotec® 0307
Composition
• Proprietary blend, safe, synergized
surfactants, nature identical odour
control agents.
Odour Control – Vapour Phase
Features Anotec® Odour control solution are an
• Removal Efficiency for Odour >80% odour mitigation chemical for
industrial, fugitive and related
Safe Non-toxic and immediate odorous emissions.
reduction Applications
To significantly reduce and/or
eliminate malodours associated with
foundries (ferrous & non-ferrous),
resin manufacturers, soil and site
remediation activities, landfill
applications & end-user activities that
liberate odours to atmosphere
(fugitive or diffuse sources).

www.anotec.com.au

Anotec Pty Limited


Tel: (02) 9700 1222 | Fax: (02) 9700 1771 | Email: service@anotec.com.au
All rights reserved by Anotec Pty Limited
Tel: (02) 9700 1222 | Fax: (02) 9700 1771 | Email: service@anotec.com.au

General Information

DESCRIPTION
The chemical constituents of Anotec® 0307 are highly
active organic compounds that include but are not Neither slight branching nor increments in the length
limited to sugar derivatives and peptides. Anotec’s of the carbon chain appear to exert a significant
unique blend of compounds forms complexes that effect on the rate of degradation. Run-off can be
effectively absorb and treat offending odour disposed of via normal wastewater channels. The
molecules. Further, the Anotec® 0307 blend, when proprietary additives for binding, enhancing
applied, reduces the surface tension in the liquid biodegradation and odour profiling – each of which is
phase and assists in the blocking or inhibition of >2% - are all food grade quality. The active
volatisation of malodours. The effectiveness of ingredients in this product have boiling points in
Anotec® 0307 Odour Control formulations stems from >1500C. Anotec® 0307 is fully miscible in water and
the unique chemistry of synergised surfactants ad the product does not have a measurable flash point.
odour profiling technology, enabling efficient and Application via a misting or fogging system ensures
immediate reduction in chemical odour direct contact between the Anotec odour control
concentrations when compared to conventional odour formulation and the malodorous emission. Upon
abatement technologies. The non-ionic surfactants in direct contact, odour analysis shows a significant
the product are readily biodegradable in standard reduction in chemical odour concentrations for each
component identified in any malodorous mix.*
BOD tests and CO2 evolution procedures.

* GC/MS & Olfactometry – Laboratory & Field tests

TYPICAL PROPERTIES
Test Unit Result

Appearance Clear / White liquid


Vapour Pressure
(mm of Hg@250C) Similar to water
0
Flash Point, closed cup C >150
Solubility in water % 100

3
All rights reserved by Anotec Pty Limited
Tel: (02) 9700 1222 | Fax: (02) 9700 1771 | Email: service@anotec.com.au

Performance Characteristics of Anotec® 0307 odour control formula compared


with Conventional Odour Abatement Methods (Masking Agent) – Extrapolated
Data

Anotec® 0307 Masking Agent


(1:300 dilution) (1:300 dilution)
Odour Profiling Perfume
Technology
Removal Efficiency Removal Efficiency
(%) (%)
VOCs and Other Odours

Chemical Components (ppm)……………………….


1,1,1 trichloroethane 5.62………………………... 95 0.5
2-methyl pentane 3.5…………………………….. 98.25 8.7
2-methyl butane 0.9………………………………. 95.71 0.2

Chemical Mixtures (ppm)


Orgnosphosphates12.0……………………………. 99.3 Increase
Termiticide10.8……………………………………… 99.95 Increase
C7-C11 alkanes 79.36……………………………. 89.90 9.6

Chemical Components (ppm)


C3-alkylbenzenes 9.6…………………………….. 99.64 Increase
Carbon disulfide 2.3………………………………. 98.13 0.9
Carbonyl sulphide 8.2…………………………….. 99.96 0.7

Chemical Components (ppm)


(Olfactometry reported = 300 ODU) ODU = 4 ODU = 515
Dimethyl sulphide 15.3…………………………… 99.14 0.31
Hydrogen sulphide 58.9………………………….. 99.98 3.20
Methyl mercaptan 21.32…………………………. 99.92 2.93
Methyl amine 16.8………………………………… 98.81 0.2

Simulated Wind Tunnel Tests H2O Only


(Permeation device)
Raw / Untreated Odour: ODU = 18, 227 ODU = 1063 ODU = 26,309

HOW TO USE: CONCENTRATE FORMULAS:


Anotec® 0307 – Vapour Phase
Industrial: (Liquid Phase) Formulations. To yield a 200-L “Ready-To-Use” Product:
Anotec® 0307 odour profiling formulations may be 1. Partially fill an empty 200-Litre tank water
used as an additive ingredient for highly odorous (approx. half way)
products such as pesticides, slurries, lagoons, paint 2. Pour 5-Litres of Anotec concentrate
etc. The product is identified as Anotec PRO5L and is formula into the partially filled tank.
stable upon application that does not affect the 3. Place water source hose into the tank
chemistry of the product to be treated. If added to making sure that it is fully submerged in
wet scrubber liquor, an anti-foaming agent may be the liquid. This will ensure that the
required and is available via Anotec’s network of product is being mixed whilst being filled
distributors. Anotec PRO5L, when used as an odour up with water.
control additive to finished products must not be 4. Stop filling the tank once the level has
diluted prior to use. This product is supplied as a reached the 200-L mark.
Hyperconcentrate formulation. Available in 200-L, 25- 5. Your product is now ready to be used via
L 5-L & 1-L containers. Other volumes available upon the misting system (make sure if you are
request. using a Dosmatic or Dosatron that they are
set at the pre-determined dilution rate –
call your local service person)
4
All rights reserved by Anotec Pty Limited
Tel: (02) 9700 1222 | Fax: (02) 9700 1771 | Email: service@anotec.com.au

INDUSTRIAL & WASTE MANAGEMENT


(Vapour Phase Formulations)
Anotec® 0307 odour control formulations are diluted LIMITATIONS
with clean water prior to use. Once the chemistry of
the emission has been determined, the appropriate Anotec products are neither tested nor represented
Anotec® 0307 formulation will be supplied. As a as suitable for medical or pharmacological use.
guideline, Dilution rates vary between 1:40 – 1:1000.
Example, small sewage installations with low-medium PRODUCT EVALUATION & ASSESSMENT
odour levels will dilute Anotec® 0307 1:40 prior to INFORMATION
use.
Evaluation of Anotec odour control formulations have
Anotec® 0307 products can be applied via high been carried out by numerous government and
pressure or air atomisation devices, via portable private laboratories and organisations. These include
(hand-held and larger) misting systems or custom but are not limited to ANSTO, Environmental Science
built application equipment depending on the Program (AUS), Odor Science Engineering (USA),
industry type and area to be treated. Korea Heavy Industry Group (ROK), Stephenson &
Associates (AUS), CH2MHill (AUS), Dow Corning (NZ
APPLICATION Achieving the correct droplet size is for PRO5L), University of New South Wales (AUS).
fundamental in ensuring the efficacy of Anotec odour Removal Efficiency (RE%) using Anotec formulations
control formulations. Anotec product consumption to challenge malodours have consistently been
rates heavily depend on application device and reported to be >80%.
duration of atomisation.
LIMITED WARRANTY INFORMATION – PLEASE READ
USABLE LIFE & STORAGE When stored between 200C CAREFULLY
ad 400C Anotec® 0307 odour control products have a
shelf life of two years from the date of manufacture. The information contained herein is offered in good
Once opened, the product will need to be consumed faith and is believed to be accurate. However, due
within 6 months to retain efficacy. to varying conditions and methodologies engaged by
clients when using our products that are beyond our
PACKAGING control, we strongly advise against using this
All Anotec odour control formulations are available information in conjunction with any other product
from 500-ml bottles to 1000-L tanks. and forbid the use of any analytical or sensory
assessments to be used as support for implementation
at any given site unless a comparative study is
conducted onsite.

Anotec’s sole warranty is that the product will meet


the Anotec sales specification in effect at the time of
despatch from their warehouse or delivery dock.
Your exclusive remedy for breach of such warranty is
limited to refund of purchase price or replacement of
any product proven to be other than as warranted.

5
All rights reserved by Anotec Pty Limited
Tel: (02) 9700 1222 | Fax: (02) 9700 1771 | Email: service@anotec.com.au

Application Equipment

6
All rights reserved by Anotec Pty Limited
Tel: (02) 9700 1222 | Fax: (02) 9700 1771 | Email: service@anotec.com.au