TUWAIRQI STEEL MILLS LIMITED

Doc. Title:

DATA SHEET OF HORTICULTURE SYSTEM PUMPS

Date:

Sep. 11, 2012

Doc. No.:

P1210-DS-P602

Rev. A

Sheet 1 of 2

DATA SHEET OF HORTICULTURE SYSTEM PUMPS

A Rev.

Issued for Review Description

Sep. 24, 2012 Date

TA Prepared

ZW Checked

IUS Approved

Doc. Title.

TUWAIRQI STEEL MILLS LIMITED DATA SHEET OF HORTICULTURE SYSTEM PUMPS

Doc. No.: Prep./Chk By Rev. Date Owner A Issue:

P1210-DS-P602 TA/ZW App. By IUS

Issued for Review Sheet Vendor 2 of 2

24-Sep-2012 Contractor

1
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46

Applicable To: For Tag No. Pumps Qty. Item No. Engine Qty. Item No. Pump Mfr. 0 1

Proposals PU-F66.4 Motor Qty. Turbine Qty.

Purchase

As Built Site Service

Data Filled By:

Consultant

Tuwairqi Steel Mills Limited 1 0

TSML DRI Plant- Port Qasim, Karachi RO Rejected Water Supply To Green Lawns Centrifugal Mtd By Mtd By Serial No. -

Provided By Item Description Provided By Item Description Type

OPERATING CONDITIONS Liquid RO Reject Water 30 40 1 0.07 0.75 Flow at PT. (m/hr) Discharge Press. (barg) Suct. Press.(barg) Diff. Press. (bar) Diff. Head (m) NPSHA (m) 1500 TDS Outdoor Intermittent CONSTRUCTION Nozzles Suction Discharge Case-mount: Split: Press: Connect: Impeller Dia. : Mount: Bearings-type: Lube: Coupling: Driver Mtd. By: Packing: Mech. Seal: Axial Vent Rated Between Bearings Radial Ring Oil Mfr. Pump Mfr. Mfr. & Type Mfr. & Model Mfr. Code AUXILIARY PIPING (AS APPLICABLE) C.W. Pipe Plan Total cooling water (m/hr) Packing Cooling Injection Req'd: Seal Flush Piping Plan External Seal Flush Fluid Auxiliary Seal Plan Aux. Seal Quench Fluid MOTOR DRIVER (VTA) VTS RPM TEFC VTS Frame Bearings Insulation Mfr. Siemens/ABB Volts/Phase/Cycles Lube Type F Full Load Amps 400V/3f/50Hz CS SS CS SS Total m/hr Other Total m/hr Other CS SS Other Tubing Sight F.I. Req'd barg Tubing barg Tubing Pipe Pipe Pipe Flood Oil Mist Size (in) 6" (Note-2) 6" (Note-2) Centerline Rad; Max. Allow Rating 150# 150# Foot Volute Type: barg @ Drain Max. Overhung Thrust Flinger Model Driver Mfr. Size/No. of Rings Pressure Facing RF RF Bracket SGL Vert. (Type) DBL Diffuser barg C Hydro Test Gage Type: Location Non-Wit. Perf. Area: Random Safe 0.00 125 Rated 4.0 Rated 4.50 46 8.0 Hyd. Power (kW) 14 Hazardous -0.50 Note-3 RPM VTS

PERFORMANCE (VTA) Proposal Curve No. NPSHR (Water) BHP Rated (kW) 17.5 (VTC) VTA VTA VTA 60 Eff. % 80 (VTC)

Normal Pumping Temp. (C) Max. Pumping Temp. (C) Sp. Gr. at PT. Vap. Press. at PT. (bara) Viscosity @ PT. (cP) Corr/Eros. Caused by Location: Working: Indoor Continuous

Max. BHP rated IMP (kW) Max. Head Rated IMP (m) Min. Continuous (m/hr) Rotation (Viewed from CPLG End) Shut off Head (m) (Max) SHOP TESTS

Wit. Perf. Wit. Hydro Wit. NPSH

Non-Wit. Hydro Non-Wit. NPSH Req'd. Shop Inspection Dismant. & Insp. Amer Test Other

Running MATERIALS (VTA) Case Impeller (s) Line Sham Pump Sham Wear Ring Bearings VTA SS 316 SS 316 N/A

Suction Strainer Sleeve Coupling VERTICAL PUMPS (N/A) Pit or Sump Depth (m) Min. Submergence Req'd. (m) Column Pipe: Line Sham: Brgs: Bowl Brg. Lube
Float & Rod

Flanged Open

Threaded Enclosed Line Sham

Water CS UP

Oil SS BRZ

Grease None

Float Switch Pump thrust, kg. Motor Notes DOWN Approx. Weight Pump & Base (kg) Turbine

47 Power (kW) 48 49 50 51 52

Cooling Type Enclosure

Cable Entries Top T.Box

B Temp. Rise Locked Rotor Amps Class I, Div.II IP-55 (Note-4) NOTES

53 1. Vendor to confirm or advise as necessary. 54 2. Suction & Discharge Line Size. Vendor to provide appropriate reducers & expanders. 55 3. The rated flow of pump shall be 110% of Normal flow at the discharge head. 56 4. Enclosure shall be according to Doc. No. 3822-MC-02S 57 5. Pump drain sizes shall be provided by vendor 58 VTA - Vendor to Advise 59 VTC - Vendor to Confirm 60 VTS - Vendor to Specify