Sunteți pe pagina 1din 3

Stefan Xhunga 04-Tirana AL

kriselaengineering@yahoo.com Mobile: 00355692495712; 00355683334265 Phone: 00355 44 80 44 64

______________________________________________________________________

Orifice Plate for Flow Measurement Model FOP-10 WIKA Data Sheet AC 09.15
Referenca: http://en-co.wika.de/upload/DS_AC0915_GB_843.pdf

Disk i hapur pr matjen e prurjeve


Applications (Prdoret): Power generation (Prodhim energjie) Oil production and refining(Prodhim dhe rafinim vaji)

Water treatment and distribution

(Prpunim dhe shprndarje uji) Gas processing and transmission(Prpunim dhe shprndarje
gazi)
Chemistry and petrochemistry(Kimi

dhe Petrokimi)

Special Features
Maximum working temperature 800 C

(Temperatura max. e puns 800 C)


Maximum working pressure 400 bar

(I prshtatshm pr matjen e prurjeve


pr lngje, gaze dhe avuj)
Accuracy 1 % of actual flow rate Repeatability of measurement 0.1 %

(Presioni max. i puns 400 bar)


Suitable for liquid, gas, and steam flow measurement

Description
FOP-10 is an orifice plate for flow rate measurement of aggressive and non-aggressive media. It is particularly designed for large pipelines. This orifice plate produce a differential pressure signal proportional to the square of the flow rate. The differential pressure output is normally piped to a differential pressure transmitter in order to generate an electrical signal proportional to the flow rate. A differential pressure gauge or switch can be used to provide local mechanical indication or flow rate switching. For certain applications, the differential pressure transmitter can be directly mounted on to the FOP-10 via an integral 3 or 5 valve

manifold.
Orifice flange with orifice plate, sealign-type smooth (RF) In every flange there are two outlet-bores (placed offset of 180 ) and a jackscrew aligned correspondingly. Special desings. i. e. other angle positions of the pressure taps and screwed-in pressure tabs are possible.

Specifications
Fits pipe sizes 50 to 2000 mm Nominal pressure PN 1 up to PN 100 Sealing type smooth Accuracy 1 % of actual flow rate Repeatability 0.1 % of measurement Reynolds number Minimum 2 x 103 Suitable for media Liquid, gas and steam Maximum viscosity 50 cp (mPas)

Standard Features
Probe material Stainless steel Identification On inlet side of handle: +, Tag-No., nominal pressure, inner pipe diamenter, bore diameter and material Design Orifice plate

Design of version with orifice flange

Optional extras

____________________________________________________________ WIKA Orifice Plate for Flow Measurement


WIKA Data Sheet AC 09.15

Stefan Xhunga 04-Tirana AL


Fits pipe sizes 10 to 400 mm with seeling-type nose and tongue or lense Nominal pressure up to PN 400 with sealing-type lense Quarter circle nozzle, orifice with nose, lense-sealing and ring-joint sealing With orifice flnage and pressure-tap With meter runs for welding in or with joint flanges Ring chamber orifice plate Orifice plate with carrier ring, single bore pressure tabs

kriselaengineering@yahoo.com Mobile: 00355692495712; 00355683334265 Phone: 00355 44 80 44 64

______________________________________________________________________

Design of version with orifice flange


Orifice flange with orifice plate, sealign-type smooth (RF) In every flange there are two outlet-bores (placed offset of 180 ) and a jackscrew aligned correspondingly. Special desings. i. e. other angle positions of the pressure taps and screwed-in pressure tabs are possible.

Designs of orifice plate


They depend on nominal size, media and the required sealing-type. Normal configuration is the orifice plate (figure 1). A special configuration is the reducer orifice plate (figure 2). It servers mainly in small pipes for pressurereduction and for flow-linitation. The quarter circle nozzle

(figure 3) is assigned for use with small Reynolds figures. x = not standardised in DIN standard (DN 50 adapted to general practice) Thickness is laid out for a differential pressure of max. 1000 mbar. Thickness of the orifice plate Orifice with nose, lense-sealing and ring-joint-sealing (figures 4 - 6) show you the possible sealing-types. Quarter circle nozzles according to VDI/VDE 2041 for special requirements are available for deliver.

Tek WIKA Data Sheet AC 09.15 jepen te dhena te plota per parametrat, etj. Design of version with meter run:

____________________________________________________________ WIKA Orifice Plate for Flow Measurement


WIKA Data Sheet AC 09.15

Stefan Xhunga 04-Tirana AL

kriselaengineering@yahoo.com Mobile: 00355692495712; 00355683334265 Phone: 00355 44 80 44 64

______________________________________________________________________

Ktu Ju mund t vendosni porosin tuaj me parametrat q dshironi! Porosia juaj mund t jet edhe pr konfigurime te tjera: WIKA Data Sheet AC 09.15 Ju, pr porosin tuaj, duhet t percaktoni t gjitha tiparet e veanta, ekzaktesisht, duke shkruar vetem vlerat e opsionit qe ju duhet:
http://en-co.wika.de/upload/DS_AC0915_GB_843.pdf http://en-co.wika.de/download_datasheets_AC_en_co.WIKA?ActiveID=5118

/Accessories/Orifice Plate for Flow Measurement


Porosin tuaj ju duhet q ta drgoni ne adresn:

kriselaengineering@yahoo.com
Oferta, per Ju, do te vije direct nga WIKA. mimi i arsyeshm!

____________________________________________________________ WIKA Orifice Plate for Flow Measurement


WIKA Data Sheet AC 09.15

S-ar putea să vă placă și