National Voluntary Laboratory Accreditation Program

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005


Idaho National Laboratory - Calibration Services Dept. P. O. Box 1625 Idaho Falls, ID 83415-4137 Mr. Jim Allred Phone: 208-526-2017 Fax: 208-526-5462 E-Mail: jim.allred@inl.gov URL: http://info.inel.gov/calibration/capabilities.asp

CALIBRATION LABORATORIES
NVLAP Code: 20/A01 DIMENSIONAL NVLAP Code: 20/D03 Gage Blocks

NVLAP LAB CODE 200115-0 Revised Scope: 2009-02-04


Compliant

ANSI/NCSL Z540-1-1994; Part 1

Range in inches
Master Set Calibration 0.010 to 0.09375 0.100 to 1.000 2.000 3.000 4.000 0.050 to 0.09375 0.100 to 1.000 2.000 3.000 4.000 0.050 to 0.09375 0.100 to 1.000 2.000 3.000

Best Uncertainty () in in note 1 3.6 3.0 3.0 3.0 3.5 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0

Remarks Steel Steel Steel Steel Steel Chrome Carbide Chrome Carbide Chrome Carbide Chrome Carbide Chrome Carbide Tungsten Carbide Tungsten Carbide Tungsten Carbide Tungsten Carbide

2009-01-01 through 2009-12-31


___________________________________________ Effective dates _______________________________________________________ For the National Institute of Standards and Technology

Page 1 of 6

NVLAP-01S (REV. 2004-10-31)

National Voluntary Laboratory Accreditation Program


CALIBRATION LABORATORIES NVLAP LAB CODE 200115-0 Revised Scope: 2009-02-04
3.0 Tungsten Carbide

4.000 Long Block Calibration 5 6 7 8 10 12 16 20

4.4 4.4 5.3 5.3 6.6 7.5 10.3 11.8 Best Uncertainty () in m note 1 0.08 0.08 0.08 0.08 0.08 0.09

Steel Steel Steel Steel Steel Steel Steel Steel

Range in mm
Master Set Calibration 0.3 to 0.9 1.0 to 24.5 25 50 75 100 Long Block Calibration 125 150 175 200 250 300 400 500

Remarks
Steel Steel Steel Steel Steel Steel

0.10 0.11 0.12 0.13 0.17 0.19 0.27 0.30

Steel Steel Steel Steel Steel Steel Steel Steel

2009-01-01 through 2009-12-31


___________________________________________ Effective dates _______________________________________________________ For the National Institute of Standards and Technology

Page 2 of 6

NVLAP-01S (REV. 2004-10-31)

National Voluntary Laboratory Accreditation Program


CALIBRATION LABORATORIES NVLAP LAB CODE 200115-0 Revised Scope: 2009-02-04

ELECTROMAGNETICS - DC/LOW FREQUENCY NVLAP Code: 20/E05 Resistance Range in Ohms 0.1 1.0 10.0 100 1k 10 k 100 k 1M NVLAP Code: 20/E06 DC Voltage Range in Volts Fixed Points 10 J Array 1.018 J Array 10 J Array 1.018 J Array 10 Zener Reference Comparison Variable Points Up to 100 m 0.1 to 1 1 to 10 10 to 100 100 to 1000 4.0 0.8 0.5 0.8 2.5 Zener + Divider Zener + Divider Zener + Divider Zener + Divider Zener + Divider Best Uncertainty ( V/V)note 1 Remarks Best Uncertainty ( /) note 1 0.35 0.3 0.35 0.5 0.6 0.5 1.0 5.0

Remarks
In air In oil In oil In oil In oil In oil In air In air

0.013 0.11 0.06 0.23 0.3

Single Measurement Single Measurement Over Extended Time Over Extended Time Over Extended Time

2009-01-01 through 2009-12-31


___________________________________________ Effective dates _______________________________________________________ For the National Institute of Standards and Technology

Page 3 of 6

NVLAP-01S (REV. 2004-10-31)

National Voluntary Laboratory Accreditation Program


CALIBRATION LABORATORIES NVLAP LAB CODE 200115-0 Revised Scope: 2009-02-04

TIME AND FREQUENCY NVLAP Code: 20/F01 Frequency Dissemination Range in MHz 0.1, 1, 5, 10 MECHANICAL NVLAP Code: 20/M06 Force Tension and Compression Range in lbf 10 to 20 >20 to 40 >40 to 50 >50 to 400 >400 to 1000 100 to 1000 1000 to 11 000 10 000 to 100 000 100 000 to 400 000 NVLAP Code: 20/M08 Mass Range 1 kg 500 g 200 g 100 g 50 g 20 g 10 g Best Uncertainty () in g note 1 140 98 58 22 15 8.0 3.8 Best Uncertainty () % of F/S note 1 0.017 0.006 0.0058 0.0043 0.0042 0.020 0.0078 0.0073 0.05 Best Uncertainty () note 1 1 x 10-12/24 hours

Remarks
NIST FMS System

Remarks
Primary Standard (Deadweight) Primary Standard (Deadweight) Primary Standard (Deadweight) Primary Standard (Deadweight) Primary Standard (Deadweight) Secondary Standards (Load Cells) Secondary Standards (Load Cells) Secondary Standards (Load Cells) Secondary Standards (Load Cells)

Remarks
Repetitive Double Substitution Repetitive Double Substitution Repetitive Double Substitution Repetitive Double Substitution Repetitive Double Substitution Repetitive Double Substitution Repetitive Double Substitution

2009-01-01 through 2009-12-31


___________________________________________ Effective dates _______________________________________________________ For the National Institute of Standards and Technology

Page 4 of 6

NVLAP-01S (REV. 2004-10-31)

National Voluntary Laboratory Accreditation Program


CALIBRATION LABORATORIES NVLAP LAB CODE 200115-0 Revised Scope: 2009-02-04
5.7 3.8 5.4 2.0 0.95 2.8 4.1 2.1 0.7 1.9 2.2 1.8 Repetitive Double Substitution Repetitive Double Substitution Repetitive Double Substitution Repetitive Double Substitution Repetitive Double Substitution Repetitive Double Substitution Repetitive Double Substitution Repetitive Double Substitution Repetitive Double Substitution Repetitive Double Substitution Repetitive Double Substitution Repetitive Double Substitution

5g 2g 1g 0.5 g 0.2 g 0.1 g 0.05 g 0.02 g 0.01 g 0.005 g 0.002 g 0.001 g Balances In-Lab and On-Site Range in g 1 m to 60 >60 to 80 >80 to 200 >200 to 500 >500 to 1 k >1k to 6 k >6k to 10.1 k >10.1k to 32 k

Best Uncertainty () in mg note 1 0.10 0.12 0.50 0.80 4.0 30 40 300

Remarks Using ASTM Class 1 Weights Using ASTM Class 1 Weights Using ASTM Class 1 Weights Using ASTM Class 1 Weights Using ASTM Class 1 Weights Using ASTM Class 1 Weights Using ASTM Class 1 Weights Using ASTM Class 1 Weights

2009-01-01 through 2009-12-31


___________________________________________ Effective dates _______________________________________________________ For the National Institute of Standards and Technology

Page 5 of 6

NVLAP-01S (REV. 2004-10-31)

National Voluntary Laboratory Accreditation Program


CALIBRATION LABORATORIES NVLAP LAB CODE 200115-0 Revised Scope: 2009-02-04

THERMODYNAMICS NVLAP Code: 20/T05 Pressure Deadweight Pressure Gauge Direct Pressure Comparison Range in psi 0.4 to 18 18 to 700 700 to 4000 4000 to 40 000 NVLAP Code: 20/T07 Resistance Thermometry Fixed Certification of PRTs Range in C 0 232 420 Best Uncertainty () in mK note 1 5.7 7.1 9.4 Remarks Comparison to Reference SPRT Comparison to Reference SPRT Comparison to Reference SPRT Best Uncertainty () in ppm note 1 32 44 37 78

Remarks
Air Air Oil Oil

_____________ 1. Represents an expanded uncertainty using a coverage factor, k = 2, at an approximate level of confidence of 95 %.

2009-01-01 through 2009-12-31


___________________________________________ Effective dates _______________________________________________________ For the National Institute of Standards and Technology

Page 6 of 6

NVLAP-01S (REV. 2004-10-31)