MAKING MODERN LIVING POSSIBLE

Design your application for superior performance Size heat exchangers for a perfect match
Danfoss XGC gasketed plate heat exchangers

One
global partner
With Danfoss you get one reliable partner for support, warranty and service. Danfoss and our service partners are nearby present on all world continents.

districtenergy.danfoss.com

Designed in every scale for superior energy efficiency and performance

Demands for quality, efficiency and economy Basically every customer demands the security of a stable and efficient operation of the heating and cooling installation. To avoid low comfort periods in the building or downtime caused by maintenance and repair, the system installation has to be service friendly. A gasketed plate heat exchanger meets these requirements as an efficient and high-quality solution. Since large scale heat exchangers are extensive investments, the total economy of the system investment is of significant importance. It is necessary that the operating cost is minimized with high energy efficiency and expectancy of a long total system lifetime.

These demand conditions require superior performance of all parts of the system installation and high quality of all components. Your supplier must fulfil these demands. Danfoss XGC gasketed plate heat exchangers Danfoss XGC heat exchangers are designed for demanding temperature, pressure and flow conditions. Danfoss offers a very comprehensive range of efficient heat exchangers for applications in any scale. The heat exchangers are built on a module based concept. Frames, plates and connections can be combined to form a number of different exchanger types. By using different types of plates,

with different characteristics, the exchangers can be adapted to a wide variety of applications. The XGC heat exchangers can easily be dismantled for inspection, cleaning and maintenance. Another benefit of the XGC gasketed plate heat exchangers is that they can easily be expanded or adapted by adding or replacing plates when the conditions change. The product range is suited for applications requiring high energy efficiency like district cooling interchangers, district heating substations or cooling/ heating pressure breakers.

The XGC range offers: Tall and narrow types with long thermal length to achieve close temperature approach Compact types for general heating, HVAC and hot water systems Large flow systems Double wall types for separation of drinking water from heating or cooling water

Product range specifications: Flow range: Working pressure: Connections: Temperature: 10 - 4000 m3/h 10 - 25 bar DN 32 DN 500 -20 to +180C

XGC-008

XGC-009

XGC-013 XGC-016

XGC-026

XGC-042 XGC-044

Connection size, DN 32-50

DN 100

XGC-051 XGC-054

XGC-091

XGC-118

XGC-060

XGC-100

XGC-140

DN 150

DN 200

XGC-085

XGC-145

XGC-205

XGC-265

XGC-325

DN 300

XGC-230

XGC-330

XGC-430

DN 500

In every scale

options from 77 cm to 4,4 meters!

Dimensions Type XGC 008 XGC 009 XGC 013 XGC 016 XGC 026 XGC 042 XGC 044 XGC 051 XGC 054 XGC 091 XGC 118 XGC 060 XGC 100 XGC 140 XGC 085 XGC 145 XGC 205 XGC 265 XGC 325 XGC 230 XGC 330 XGC 430 Heat transfer area per plate (m2) 0.075 0.088 0.12 0.135 0.27 0.44 0.44 0.55 0.552 0.91 1.18 0.56 1.01 1.46 0.91 1.53 2.14 2.76 3.37 2.37 3.27 4.17 32 40 50 50 100 100 100 150 150 150 150 200 200 200 300 300 300 300 300 500 500 500 Connections (DN) Width B (mm) 180 250 320 320 450 450 450 585/630 630 626 626 825 825 825 1060 1060 1060 1060 1060 1380/1510/1540 1380/1510/1540 1380/1510/1540 Height H (mm) 774 725 832 832 1110/1265 1520/1675 1675 1730 1730 2390 2870 1700 2280 2860 1985 2565 3215 3795 4375 3172 3782 4392 Length D (mm) 72 90 140 140 164/220 164/220 220 300 300 300 300 350 350 350 360 360 360 360 360 450 450 450 E (mm) 640 555 592 592 779 1189 1189 1143 1143 1800 2280 910 1490 2070 1140 1720 2300 2880 3460 2090 2700 3310 F (mm) 60 100 135 135 226 226 226 300 300 285 285 420 420 420 570 570 570 570 570 700 700 700

Wide span frame types to fit your needs


Frame types
Frame type NI and PI Frame type N and P

Plates, gaskets materials, working conditions

Plate materials AISI 304 / EN 1.4301 AISI 316 / EN 1.4401 Titanium Grade 1 254 SMO C-276 Titanium Grade 11 Nickel 200/201 Gaskets Nitril EPDM FKM, Viton Max. working pressure T-frame 6 bar NI/N 10 bar PI/P 16 bar SI/S 25 bar Max. working temp. Nitril 140C EPDM 170C FKM 180C Approvals PED 97/23/EC

Special demanding applications


we manage the challenges!

Double wall heat exchangers No risk of flow media contamination with double wall heat exchangers. The plates are welded together around the port holes in pairs. This design requires one additional plate per flow channel. In case a plate or gasket is leaking, the primary and secondary media will not be mixed. The leakage will also be visible from outside. The Heat exchangers are approved for drinking water.

Gasket Medium 1

Gasket Medium 2

Even if medium 1 should leak, it cannot mix with medium 2.

Gasketed heat exchangers for district cooling The district cooling systems with plate heat exchangers often replace traditional air-conditioning system in buildings. As the district cooling plant transfers cold water through the network to building and end-users, the district cooling system offers operating flexibility, lower operation costs and reduced start-up investment. Due to the increased heat exchanger surface required for efficient transfer of cold water into the cooling system, gasketed plate heat exchangers are typically the preferred choice.

Picture: Stockmann Oyj Abp

District Cooling at Stockmann Store-house, Helsinki, Finland: Substation with large scale gasketed heat exchangers from Danfoss.

- Outer dimensions of the substation: Length 15 m, width 6.5 m and height 3.5 m - Capacity of the cooling substation is 7.7 MW, divided into 3 circuits

- The substation includes 7 large gasketed plate heat exchangers - Pipe sizes on the primary side are DN 300, on the secondary side DN 150/250/300

Service and maintenance

efficient operation and reduced downtime

Dirt and scale can block your heat exchanger and cause unplanned downtime. Through a partnership agreement with a leading service provider, Danfoss offer service at customer site or in service centres located strategic places worldwide. If you have no time for servicing, a service engineer will attend your site to inspect the plate heat exchanger. The engineer will work out an individual action plan to fit your requirements,

carry out performance diagnostics, high pressure washing of plates while hanging in the frame, plate inspection, checking and replacing gaskets as needed and reassemble the unit. A fouled plate pack can be replaced with a spare plate pack to reduce the service time on the unit. The fouled plates will be carefully packed and shipped to the closest service centre.

At partner service centres, Danfoss can provide you the advanced service that cannot be performed on site. We offer high level competence together with advanced equipment to ensure comprehensive service. We clean the plates and put in new gaskets. Every plate is thoroughly inspected to locate any pinhole or cracks. After a final hydrostatic test they are packed and shipped back to your location.

One global partner With Danfoss you get one reliable partner for support, warranty and service. Danfoss and our service partners are nearby present on all world continents.

Controls for every district heating and cooling application


Danfoss provides a complete range of automatic controls, heat exchangers and substations needed throughout the process of generating and distributing heat or cooling to homes and buildings. Our products contribute to individual comfort, reduce energy consumption as well as providing reliable and lasting operations and guarantee minimum servicing. The product range consists of controllers for all purposes: Differential pressure and flow controllers Self-acting temperature controllers Electronic controllers Motorized control valves Ball valves Heat meters Danfoss offers a wide range of prefabricated substation for heating and cooling with XGC heat exchangers.

System performance benefits - enabled by Danfoss automatic controls


Differential pressure control provides: Hydraulic balancing of the district heating network Constant differential pressure (p) across the control valve Low diffenrential pressure (p) across the control valve Flow control and flow limitation provide: Exact limitation of the flow Temperature controllers provide: Exact temperature control Ensures adequate heat or cooling supply to all subscribers Reduces flow in the network Reduces energy loss Increases pump performance

Enables accurate temperature control and low return temperature Prolongs the life of the control equipment Prevents cavitation Reduces noise emission in the system Secures adequate heat or cooling supply to all subscribers Establishes a reliable basis for settling of fixed subscriber costs Ensures optimum hydraulic balance Ensures adequate temperatures in your system Offers modular design possibilities (e.g. controller + safety thermostat) Offers safety functions (according to DIN standards)

E-mail: heating@danfoss.com www.districtenergy.danfoss.com

VB.EJ.B1.02

24487 www.factorx.dk