# lsdev -Cc adapter ent0 Available 03-20 4-Port 10/100/1000 Base-TX PCI-X Adapter (14101103) ent1 Available 03-21

4-Port 10/100/1000 Base-TX PCI-X Adapter (14101103) ent2 Available 03-30 4-Port 10/100/1000 Base-TX PCI-X Adapter (14101103) ent3 Available 03-31 4-Port 10/100/1000 Base-TX PCI-X Adapter (14101103) ent4 Available Virtual I/O Ethernet Adapter (l-lan) ent5 Available Virtual I/O Ethernet Adapter (l-lan) ent6 Available Shared Ethernet Adapter ent7 Available Virtual I/O Ethernet Adapter (l-lan) ent8 Available Virtual I/O Ethernet Adapter (l-lan) ent9 Available Shared Ethernet Adapter ent10 Available Virtual I/O Ethernet Adapter (l-lan) ent11 Available Shared Ethernet Adapter fcs0 Available 05-08 FC Adapter fcs1 Available 05-09 FC Adapter pager0 Available Pager Kernel Extension sissas0 Defined 00-08 PCI-X266 Planar 3Gb SAS Adapter sisscsia0 Defined 04-08 PCI-XDDR Dual Channel Ultra320 SCSI Adapter vasi0 Available Virtual Asynchronous Services Interface (VASI) vbsd0 Available Virtual Block Storage Device (VBSD) vhost0 Available Virtual SCSI Server Adapter vhost1 Defined Virtual SCSI Server Adapter vhost2 Available Virtual SCSI Server Adapter

vhost3 Available Virtual SCSI Server Adapter vhost5 Available Virtual SCSI Server Adapter vhost7 Available Virtual SCSI Server Adapter vhost8 Available Virtual SCSI Server Adapter vhost9 Available Virtual SCSI Server Adapter vhost10 Available Virtual SCSI Server Adapter vhost11 Available Virtual SCSI Server Adapter vsa0 Available LPAR Virtual Serial Adapter # lsattr -El ent6 accounting enabled Enable per-client accounting of network statistics True ctl_chan ent5 Control Channel adapter for SEA failover True gvrp no Enable GARP VLAN Registration Protocol (GVRP) True ha_mode auto High Availability Mode True jumbo_frames no Enable Gigabit Ethernet Jumbo Frames True large_receive no Enable receive TCP segment aggregation True largesend 1 Enable Hardware Transmit TCP Resegmentation True netaddr 0 Address to ping True pvid 117 PVID to use for the SEA device True pvid_adapter ent4 Default virtual adapter to use for non-VLAN-tagged packets True qos_mode disabled N/A True real_adapter ent0 Physical adapter associated with the SEA True thread 1 Thread mode enabled (1) or disabled (0) True virt_adapters ent4 List of virtual adapters associated with the SEA (comma separated) True # # lscfg -vpl ent6 lscfg: device ent6 not found. # lscfg -vpl ent0 ent0 U7311.D20.650B4BC-P1-C01-T1 4-Port 10/100/1000 Base-TX PCI-X Adapter (14101103) 4-Port 10/100/1000 Base-TX PCI-X Adapter: Part Number.................03N5444 FRU Number..................03N5444 EC Level....................H13855 Manufacture ID..............YL1021 Network Address.............001A64B95CB8 ROM Level.(alterable).......CN0110 Hardware Location Code......U7311.D20.650B4BC-P1-C01-T1 PLATFORM SPECIFIC Name: ethernet Node: ethernet@4

Device Type: network Physical Location: U7311.D20.650B4BC-P1-C01-T1 # lscfg -vpl ent4 ent4 U8204.E8A.65081F2-V2-C11-T1 Virtual I/O Ethernet Adapter (l-lan) Network Address.............DA5BD6BD870B Displayable Message.........Virtual I/O Ethernet Adapter (l-lan) Hardware Location Code......U8204.E8A.65081F2-V2-C11-T1 PLATFORM SPECIFIC Name: l-lan Node: l-lan@3000000b Device Type: network Physical Location: U8204.E8A.65081F2-V2-C11-T1 # # lscfg -vpl ent5 ent5 U8204.E8A.65081F2-V2-C12-T1 Virtual I/O Ethernet Adapter (l-lan) Network Address.............DA5BD6BD870C Displayable Message.........Virtual I/O Ethernet Adapter (l-lan) Hardware Location Code......U8204.E8A.65081F2-V2-C12-T1 PLATFORM SPECIFIC Name: l-lan Node: l-lan@3000000c Device Type: network Physical Location: U8204.E8A.65081F2-V2-C12-T1 # # # ####################################################################### #################3333 # lscfg -vpl ent9 lscfg: device ent9 not found. # lsattr -El ent9 accounting enabled Enable per-client accounting of network statistics True ctl_chan ent8 Control Channel adapter for SEA failover True gvrp no Enable GARP VLAN Registration Protocol (GVRP) True ha_mode auto High Availability Mode True jumbo_frames no Enable Gigabit Ethernet Jumbo Frames True

large_receive no Enable receive TCP segment aggregation True largesend 1 Enable Hardware Transmit TCP Resegmentation True netaddr 130.7.0.10 Address to ping True pvid 7 PVID to use for the SEA device True pvid_adapter ent7 Default virtual adapter to use for non-VLAN-tagged packets True qos_mode disabled N/A True real_adapter ent1 Physical adapter associated with the SEA True thread 1 Thread mode enabled (1) or disabled (0) True virt_adapters ent7 List of virtual adapters associated with the SEA (comma separated) True # lscfg -vpl ent1 ent1 U7311.D20.650B4BC-P1-C01-T2 4-Port 10/100/1000 Base-TX PCI-X Adapter (14101103) 4-Port 10/100/1000 Base-TX PCI-X Adapter: Part Number.................03N5444 FRU Number..................03N5444 EC Level....................H13855 Manufacture ID..............YL1021 Network Address.............001A64B95CB9 ROM Level.(alterable).......CN0110 Hardware Location Code......U7311.D20.650B4BC-P1-C01-T2 PLATFORM SPECIFIC Name: ethernet Node: ethernet@4,1 Device Type: network Physical Location: U7311.D20.650B4BC-P1-C01-T2 # ksh: ^[[B^[[B^[[B^[[B^[[B^[[B^[[B^[[B: not found # # lscfg -vpl ent1 ent1 U7311.D20.650B4BC-P1-C01-T2 4-Port 10/100/1000 Base-TX PCI-X Adapter (14101103) 4-Port 10/100/1000 Base-TX PCI-X Adapter: Part Number.................03N5444 FRU Number..................03N5444 EC Level....................H13855 Manufacture ID..............YL1021 Network Address.............001A64B95CB9 ROM Level.(alterable).......CN0110 Hardware Location Code......U7311.D20.650B4BC-P1-C01-T2

PLATFORM SPECIFIC Name: ethernet Node: ethernet@4,1 Device Type: network Physical Location: U7311.D20.650B4BC-P1-C01-T2 # # lscfg -vpl ent7 ent7 U8204.E8A.65081F2-V2-C13-T1 Virtual I/O Ethernet Adapter (l-lan) Network Address.............DA5BD6BD870D Displayable Message.........Virtual I/O Ethernet Adapter (l-lan) Hardware Location Code......U8204.E8A.65081F2-V2-C13-T1 PLATFORM SPECIFIC Name: l-lan Node: l-lan@3000000d Device Type: network Physical Location: U8204.E8A.65081F2-V2-C13-T1 # # lscfg -vpl ent8 ent8 U8204.E8A.65081F2-V2-C14-T1 Virtual I/O Ethernet Adapter (l-lan) Network Address.............DA5BD6BD870E Displayable Message.........Virtual I/O Ethernet Adapter (l-lan) Hardware Location Code......U8204.E8A.65081F2-V2-C14-T1 PLATFORM SPECIFIC Name: l-lan Node: l-lan@3000000e Device Type: network Physical Location: U8204.E8A.65081F2-V2-C14-T1 # ########################################################333 # lscfg -vpl ent11 lscfg: device ent11 not found. # lsattr -El ent11

accounting enabled Enable per-client accounting of network statistics True ctl_chan Control Channel adapter for SEA failover True gvrp no Enable GARP VLAN Registration Protocol (GVRP) True ha_mode disabled High Availability Mode True jumbo_frames no Enable Gigabit Ethernet Jumbo Frames True large_receive no Enable receive TCP segment aggregation True largesend 1 Enable Hardware Transmit TCP Resegmentation True netaddr 0 Address to ping True pvid 5 PVID to use for the SEA device True pvid_adapter ent10 Default virtual adapter to use for non-VLAN-tagged packets True qos_mode disabled N/A True real_adapter ent2 Physical adapter associated with the SEA True thread 1 Thread mode enabled (1) or disabled (0) True virt_adapters ent10 List of virtual adapters associated with the SEA (comma separated) True # lscfg -vpl ent2 ent2 U7311.D20.650B4BC-P1-C01-T3 4-Port 10/100/1000 Base-TX PCI-X Adapter (14101103) 4-Port 10/100/1000 Base-TX PCI-X Adapter: Part Number.................03N5444 FRU Number..................03N5444 EC Level....................H13855 Manufacture ID..............YL1021 Network Address.............001A64B95CBA Hardware Location Code......U7311.D20.650B4BC-P1-C01-T3 PLATFORM SPECIFIC Name: ethernet Node: ethernet@6 Device Type: network Physical Location: U7311.D20.650B4BC-P1-C01-T3 # lscfg -vpl ent10 ent10 U8204.E8A.65081F2-V2-C18-T1 Virtual I/O Ethernet Adapter (l-lan) Network Address.............DA5BD6BD8712 Displayable Message.........Virtual I/O Ethernet Adapter (l-lan) Hardware Location Code......U8204.E8A.65081F2-V2-C18-T1 PLATFORM SPECIFIC Name: l-lan

Node: l-lan@30000012 Device Type: network Physical Location: U8204.E8A.65081F2-V2-C18-T1 #