PRODUCT PROFILE

ADVANTAGES
The 1747-DPS1 RS-232/DF1 port splitter allows a single RS-232/DF1 port on a Rockwell Automation controller (e.g. SLC 500, MicroLogix, PLC-5, ControlLogix, CompactLogix) to be expanded (or split) for communication with two external devices at the same time. From a single DF1 port, the splitter creates one full-function port for twoway communication between the controller and a local network. The second port is respond-only and is primarily designed to run a programming terminal or human machine interface (HMI). Both the initiate/respond, and respond-only ports are DF1 full-duplex 19.2 kbaud. CONTROLLER PLATFORMS.

RS-232/DF1 PORT SPLITTER

NEW RS-232/DF1 PORT SPLITTER FROM ROCKWELL AUTOMATION EXPANDS CONNECTIVITY OPTIONS FOR ALLEN-BRADLEY

An external 24V dc power source must be connected to the port splitter power source terminals. All communications ports are connected using standard Allen-Bradley programming cables.

KEY FEATURES
Fixed port configuration for easy setup (DF1 full-duplex, 8 bits, no parity, 1 stop bit, CRC checksum) 8-pin DIN Controller port can autobaud between 19.2 and 38.4 Kbps to take advantage of the controllers maximum baud rates 8-pin DIN Network port allows message initiation from the controller to be passed through; the baud rate is 19.2 Kbps 9-pin male D-shell Prog/HMI port is respond only, for use with an HMI or programming terminal; the baud rate is 19.2 Kbps DIN-rail mounting hardware is provided Uses standard Allen-Bradley programming cables

SPECIFICATIONS
Dimensions Dimensions with DIN Rail Mounting Hardware
3.18 in. (H) x 1.83 in. (W) x 0.97 in (D) 80.8 mm (H) x 46.5 mm (W) x 24.5 mm (D) 4.29 in. (H) x 1.99 in. (W) x 1.22 in. (D) 109 mm (H) x 50.6 mm (W) x 31 mm (D)

1.55 in. (39.3 mm) and 3.42 in. (86.9 mm) Mounting Hole Center-to-Center Spacing

Temperature Range Power Supply Requirements

0 to 60 C (32 to 140 F) 100 mA at 24V dc Class 2 / SEL V

Controller Port Baud Rate Autobaud at 19.2 Kbps or 38.4 Kbps / Auto-checksum BCC or CRC Network Port Baud Rate Prog/HMI Port Baud Rate Standards and Regulatory Approvals
19.2 Kbps / CRC 19.2 Kbps / CRC UL, C-UL-US listed, C-Tick and CE compliant for all applicable directives when product or packaging is marked

NETWORK DIAGRAM
MicroLogix 1500 Controller (or other controller with RS-232/DF1 Full Duplex port) 24V dc, 100mA, Class 2 power supply 1761-NET-ENI 1761-NET-AIC EtherNet/IP Network DeviceNet Network 1761-NET-DNI Operator Interface SLC 5/03, 5/04 and 5/05 (Channel 0) (or other controller with RS-232/DF1 Full Duplex port)

RS-232/DF1 Port Splitter

Publication 1747-PP018A-EN-P June 2005

Copyright 2005 Rockwell Automation, Inc. All Rights Reserved. Printed in USA.