No. Of Starts Considered Atmospheric Pressure Air Reciever Max. Pressure Air Reciever Min. Pressure (Equivalent to Max. Presuure of air Starter) Unit Cum Cum Bar Bar Bar
Vt=
Vt= Vt=
Note: But Standard Air recievr Available is 500 Ltrs @ 35 Bar Hence the Values will be AIR RECIEVER SIZING SRN 1 2 3 4 5 6 Representation Vt Vs N Pa P max P min Description Unit Air Tank Capacity Cum Starting ir Requirement Per Start Cum No. Of Starts Considered Atmospheric Pressure Bar Air Reciever Max. Pressure Bar Air Reciever Min. Pressure Bar (Equivalent to Max. Presuure of air Starter i.e. 10 Bar )
Formula; Vt= Vs X N X Pa (Pmax-Pmin) 1.3 X 6 X 1 (35-Pmin) 19.4 19.4 > 10 CuM Bar
0.5
Since the Pmin is greater than required 10 Bar Pressure for air starter the selection is OK
I.E The pressure in the receiver will drop from 35 bar to 19.4 bar considering no input from the compressor.Please note that the 0.41 m3/ min of air bin filled simultanously.
19.024 min