Documente Academic
Documente Profesional
Documente Cultură
P A S A D E N A
C I T Y
H A L L
C/S Stone Paver Seismic Covers allow the Pasadena City Hall to move 30"
For the seismic upgrade of the Pasadena City Hall ARG architects specified 33" SSRW Seismic Stone Paver Floor Covers to fill the moat area surrounding the buildings perimeter in its inner courtyard. The covers provide full four way movement and are designed to work in conjunction with the base isolators when a seismic event occurs.
retrofit and historic restoration. Seismic retrofit of the building included the installation of structural base isolators that now allow the
building to withstand future earthquake activity. Restoration activities were undertaken topreserve many of the historic architectural elements of City Hall.
Architect: Architectural Resources Group (ARG) San Francisco, CA Construction Manager: DM-JMH+N Contractor: Clark Construction Group
C/S
E X P A N S I O N
J O I N T
C O V E R S
No matter how much movement your project requires, we can hide it.
C/S @ de Young Museum
A major consideration of the de Young project was that the expansion joint covers must be virtually invisible within the museums weathered copper skin. Architects Fong & Chan, SF; and Herzog & de Meuron specified CS XLS cover system knowing it could be seamlessly incorporated into the facades copper panel frame. The 24" XLS covers are designed to release from the wall to provide full seismic movement.
Newseum
Architect: Polshek Partnership To provide movement and security between the Newseum and the adjacent Canadian Embassy, Polshek Partnership specified SC-1200 Exterior Covers and SRJ-1200 Roof Covers that tie both buildings together. The covers with factory mitered transitions are attached to the buildings delicate marble surface.
C/S
E X P A N S I O N
J O I N T
C O V E R S
Selection Chart
This catalog is designed to convey the design concept and variations available with C/S joint cover systemsfor more accurate details go to: www.c-sgroup.com
Floor Covers
The size of joint and movement dynamics dictate whether you require a standard or seismic expansion joint cover system. Before making a selection, there are other decisions you must make. The selection of the floor cover is often the most critical step in the specification process since the performance of the floor cover has the greatest impact on the occupants of the building. The presence of rolling loads and the need for hygiene are major considerations in cover selection, while aesthetics in seismic covers is also a significant issue.
Specialty Covers
Specialty covers, such as roof covers and vehicular joint systems, are available for most joint sizes and movement dynamics.
Cover Type
Allway Metal
Exterior Wall
Roof
Appearance
Joint Size
2" to 4"
4" and up
1" to 4"
4" and up
4" to 36"
1" to 4"
2" and up
4" and up
1" to 4"
2" and up
2" and up
1" to 16"
Description
Finishes
Carpet, vinyl, ceramic tile, terrazzo, stone Carpet, vinyl Carpet, vinyl, terrazzo, stone Concrete, carpet, vinyl Concrete, pavers, carpet, vinyl, ceramic tile Carpet, vinyl Drywall, ceramic tile Drywall, ceramic tile Drywall, panel systems, metal cladding, stone All finishes All finishes All roof finishes Concrete, paver
Designed For
All roofs
% Movement +/-
Page #
10-11
12-13
14-17
18-19
20-21
22-23
24-25
26-27
26-27
28-29
30-33
34-35
36-37
Matching Floor
N/A
N/A
N/A
N/A
N/A
N/A
8-9
10-11
12-15
16-17
N/A
N/A
N/A
Wall/Ceiling
24-25 24-25 26-27 28-29 26-27 22-23 N/A N/A N/A N/A N/A N/A N/A
Fire Barriers
Reflex Page 39 Multiflex Page 39 Multiflex or FB-97 Page 39 Reflex Page 39 Multiflex Page 39 FB-97 Page 39 Reflex Page 39 Multiflex Page 39 Multiflex or FB-97 Page 39 Reflex or Multiflex Page 39 Contact Factory Contact Factory Contact Factory
Cost Index
65 105 125 100 100 N/A 55 180 N/A 100 150 N/A N/A
All C/S Expansion Joint Covers, Seals and Processes are ISO 9001: 2000 compliant.
100
By assigning our metal systems a cost of 100, you can determine how much an alternate system of similar size will cost.
Model Data
JOINT WIDTH
Floor to Floor Covers 1" 0.75" 1.25" 1.25" GFT 100 2" 1.5" 2.5" 1.88" GFT 200 1" 0.75" 1.25" 1.18" GFPS 100 2" 1.5" 2.5" 1.88" GFPS 200 1" 0.75" 1.25" 4.31" GFS 100 2" 1.5" 2.5" 5.13" GFS 200 1" 0.75" 1.25" 4.31" GFST 100 2" 1.5" 2.5" 5.06" GFST 200
F LU S H
Thinline Floor
CO V E R S 1" - 2 "
Miami International Airport, FL
Model Data
JOINT WIDTH
Floor to Wall Covers 1" 0.75" 1.25" 1.12" GFTW 100 2" 1.5" 2.5" 1.88" GFTW 200 1" 0.75" 1.25" 1.18" GFPSW 100 2" 1.5" 2.5" 1.88" GFPSW 200 1" 0.75" 1.25" 2.63" GFSW 100 2" 1.5" 2.5" 3.56" GFSW 200 1" 0.75" 1.25" 2.63" GFSTW 100 2" 1.5" 2.5" 3.56" GFSTW 200
For odd and larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com
Floor Covers
Floor Covers
1"-3"
1"-3"
GFT-100
GFTW-100
GFPS-100
GFST-200
ES
Use this cover for: Applications with small, interior joints where minimal visual impact is preferred. Suitable for most floor finishes. Frame depth and configuration is variable to suit selected finish. Where wheeled equipment is to be used. Where hygiene is important. How it works: Single gasket expands and compresses during movement. 2" model includes aluminum support plate for added durability.
Floor Finish
Carpet
ES
1"-3"
1"-3"
GFT-200
GFTW-200
GFPS-200
GFS-200
Gasket Colors
Black White Gray Greige
10
11
Model Data
JOINT WIDTH
F LU S H
Twinline Floor
CO V E R S 2" - 4 "
Inova Fairfax Hospital, VA
Model Data
JOINT WIDTH
Floor to Wall Covers 2" 1.5" 2.5" 4.25" GTRW 200 3" 2.25" 3.75" 6.5" GTRW 300 4" 3.0" 5.0" 7.5" GTRW 400 2" 1.5" 2.5" 4.31" GTPW-HD 200 3" 2.25" 3.75" 6.56" GTPW-HD 300 4" 3.0" 5.0" 7.56" GTPW-HD 400 2" 1.5" 2.5" 4.25" GTPW 200 3" 2.25" 3.75" 6.5" GTPW 300 4" 3.0" 5.0" 7.5" GTPW 400
For odd and larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com
Floor Covers
Gasket Continuous Extruded Aluminum Recessed Center Plate Floor Finish Matching (By Others)
Floor Cover
Heavy Duty 2,000 lb. Point Load 1/4" Aluminum Center Plate ES
GTR
GTRW
GTR-HD
(Heavy Duty)
Gasket
ES
ES
Use this cover for: Applications with larger thermal movement requirements and where a flush, concealed cover is preferred. Applications using carpet or vinyl floor covering up to 1/8" deep. 3/8 Recessed center plate available. Where wheeled equipment is expected. Where hygiene is important. How it works: Dual gaskets allow for greater expansion and compression during movement. Durable aluminum plate spans joint opening.
GTP
5/8" Floor Finish (By Others)
5/8"
3/4"
GTPW
GTPW-HD
(Heavy Duty)
Gasket Colors
Black White Gray Greige
12
13
Model Data
JOINT WIDTH
Floor to Floor Covers 5" 2.5" 8.0" 12.0" SGR 500 6" 2.5" 9.0" 13.0" SGR 600 7" 2.5" 11.0" 15.0" SGR 700 8" 3.0" 12.0" 16.0" SGR 800 9" 3.0" 14.0" 18.0" SGR 900 10" 3.0" 15.0" 19.0" SGR 1000 11" 3.0" 17.0" 21.0" SGR 1100 12" 3.0" 18.0" 22.0" SGR 1200 13" 3.0" 20.0" 24.0" SGR 1300 14" 3.0" 21.0" 25.0" SGR 1400 15" 3.0" 23.0" 27.0" SGR 1500 16" 3.0" 24.0" 28.0" SGR 1600
F LU S H
Seismic Floor
CO V E R S 5" - U P
40 Bank Street, London
Model Data
JOINT WIDTH
Floor to Wall Covers 5" 4.0" 7.0" 8.5" SGRW 500 6" 4.5" 8.0" 9.5" SGRW 600 7" 5.25" 9.5" 11.0" SGRW 700 8" 5.5" 10.5" 12.0" SGRW 800 9" 5.75" 12.0" 13.5" SGRW 900 10" 6.25" 13.0" 14.5" SGRW 1000 11" 6.75" 14.5" 16.0" SGRW 1100 12" 7.25" 15.5" 17.0" SGRW 1200 13" 7.75" 17.0" 18.5" SGRW 1300 14" 8.25" 18.0" 19.5" SGRW 1400 15" 8.75" 19.5" 21.0" SGRW 1500 16" 9.25" 20.5" 22.0" SGRW 1600
SGR and SGP have same model data. SGRW and SGPW have same model data. For odd and larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com
Cycling
Plate Deflectors Ensure System Remains Operable through Major Seismic Activity
Floor Covers
Turnbar Rotates and Keeps Plate Centered During Movement Cycle ES 3/4" 3/4"
ES
SGR Contracted
SGR*
SGRW
ES 3/4"
ES
Seismic interior applications requiring a completely flush joint cover virtually concealed in the surrounding floor finishes. Applications using carpet or vinyl floor covering up to 1/8" deep. Where wheeled equipment is expected. Where hygiene is important. How it works: Dual gaskets expand and contract during minor thermal movement. During full seismic activity, gaskets disengage and the aluminum center plate that spans the joint opening temporarily displaces.
SGR Expanded SGP*
W
SGPW
Gasket Colors
Black White Gray Greige
14
15
Model Data
JOINT WIDTH
Floor to Floor Covers 2" 1.0" 3.0" 10.88" SSR 200 4" 2.5" 9.0" 12.88" SSR 400 6" 3.0" 11.0" 14.88" SSR 600 8" 4.0" 12.5" 18.6" SSR 800 10" 4.0" 15.5" 20.5" SSR 1000 12" 4.0" 18.5" 23.75" SSR 1200 14" 4.0" 21.5" 26.75" SSR 1400 16" 4.0" 24.5" 32.75" SSR 1600
PA N
Seismic Floor
CO V E R S 4 " - U P
San Francisco International Airport, CA
Model Data
JOINT WIDTH
Floor to Wall Covers 2" 1.0" 3.0" 6.44" SSRW 200 4" 1.5" 6.5" 8.44" SSRW 400 6" 2.0" 8.5" 10.44" SSRW 600 8" 4.0" 10.25" 14.38" SSRW 800 10" 4.0" 12.75" 16.88" SSRW 1000 12" 4.0" 15.25" 19.38" SSRW 1200 14" 4.0" 17.75" 21.88" SSRW 1400 16" 4.0" 20.25" 24.32" SSRW 1600
For odd and larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com
Cycling
Floor Covers
Center Pan Lifts Clear Of Moving Structure But Remains Centered Over Opening
Infill Material
2-1/4"
SSR Contracted
SSR-200-600
SSRW-400
Use this cover for: Interior and exterior seismic applications where cover concealment is desired in deeper floor finishes. Applications with floor finishes of up to 1-1/2" thick. Heavy duty versions available for limited vehicular access. How it works: Sealant and Backer Rod expand and contract for minor thermal movement. During seismic activity the center pan assembly lifts for additional movement and returns to normal position after event.
SSR Expanded SSR-800
W Unique Gravity Activated Turnbar System Returns Cover To Normal Position After Event Modular Pan Construction For High Strength ES 2-1/4" 2-1/4" Unit Sealed With Standard Caulking Can be used As Moat Cover For Base Isolated Structures ES
SSRW-800
16
17
Model Data
JOINT WIDTH
Floor to Floor Covers 1" .7" 1.2" 1.7" APF 25 2" 1.5" 2.5" 3.25" APF 50 4" 3.1" 4.7" 5.25" APF 100 2" 0.0" 4.0" 3.65" ALR 200 4" 1.0" 7.0" 6.43" ALR 400 2" 0.0" 4.0" 7.75" ALS 200 4" 1.0" 7.0" 11.75" ALS 400 2" 0" 4.0" 9.00" AL 200/HD 4" 1.0" 7.0" 12.50" AL 400/HD 2" 0.0" 3.5" 5.25" PC 200 4" 0.0" 6.5" 8.25" PC 400 2" 1.0" 3.0" .081" FYW 200 4" 2.5" 5.5" 1.25" FYW 400
S TA N DA R D A L LWAY
Metal Floor
CO V E R S 1" - 4 "
Chek Lap Kok Airport, Hong Kong
Model Data
JOINT WIDTH
Floor to Wall Covers 2" 1.0" 3.0" 2.82" ALRW 200 4" 2.5" 5.5" 5.18" ALRW 400 2" 1.0" 3.0" 4.87" ALSW 200 4" 2.5" 5.5" 7.87" ALSW 400 2" 1.0" 3.0" 6.75" ALW 200/HD 4" 2.0" 5.5" 8.25" ALW 400/HD 2" 0.0" 3.5" 3.75" PCW 200 4" 0.0" 6.5" 6.75" PCW 400 2" 1.0" 3.0" .081" FYWW 200 4" 2.5" 5.5" 1.25" FYWW 400
For odd and larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com
Floor Covers
Floor Covers
1/8 Floor Finish (By Others) Continuous Extruded Aluminum Center Plate ES 1" 1"
APF
ALR
ALRW
Continuous Extruded Aluminum Serrated Plate ES
Serrated Side Plates Create A More Flush Surface, But Impact Visibility
Use this cover for: Use APF Series for applications with heavy rolling loads. Interior applications where low maintenance is desirable or for tamperproof applications. Suitable for most floor finishes frame configuration variable to suit selected finish.
1"
1"
AL-HD
W Specify Heavy Duty Model AL-HD For 2000 lb. Rolling Loads
ALS
ALSW
How it works: Free-floating aluminum center plate spans joint and slides between frame assemblies to allow movement when required.
1"
ES
Gasket Colors
FYW
W W
PC
PCW
Note: All joint systems on this page are available for 1"-4" joints. Contact factory if required size is not listed.
18
19
Model Data
JOINT WIDTH
Floor to Floor Covers 4" 2.0" 6.0" 8.75" SJ-HD400 6" 3.0" 9.0" 11.75" SJ-HD600 8" 3.0" 13.0" 14.75" SJ-HD800 2" 1.0" 3.5" 5.5" SJPF 200 4" 1.0" 6.5" 8.5" SJPF 400 6" 1.0" 9.75" 11.5" SJPF 600 2" 1.0" 4.38" 3.5" SJP 200 4" 1.0" 7.0" 7.5" SJP 400 6" 1.0" 11.5" 11.88" SJP 600 8" 1.0" 13.5" 15.0" SJP 800 10" 1.0" 17.0" 17.88" SJP 1000 12" 1.0" 20.0" 21.0" SJP 1200 14" 1.0" 23.0" 23.88" SJP 1400 16" 1.0" 25.5" 27.0" SJP 1600
S E I S M I C A L LWAY
Metal Floor
CO V E R S 4 " - U P
Banner Gateway Medical Center, AZ
Model Data
JOINT WIDTH
Floor to Wall Covers 4" 3.0" 5.0" 6.38" 6" 4.25" 7.5" 8.88" 8" 5.0" 10.5" 12.38" 2" 1.0" 3.0" 3.75" SJPFW 200 4" 1.0" 5.25" 6.25" SJPFW 400 6" 1.0" 7.88" 8.75" SJPFW 600 2" 0.5" 3.13" 3.24" SJPW 200 4" 2.25" 5.5" 5.75" SJPW 400 6" 3.25" 8.5" 9.0" SJPW 600 8" 4.38" 11.0" 11.5" SJPW 800 10" 5.38" 13.5" 14.0" SJPW 1000 12" 6.38" 16.0" 16.5" SJPW 1200 14" 7.38" 18.5" 19.0" SJPW 1400 16" 8.38" 21.0" 21.5" SJPW 1600
For odd and larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com
Floor Covers
Floor Covers
ES Non-Shrink Grout Continuous Extruded Aluminum Side Frame ES 1-1/8" 1-1/8" 1-1/8" Aluminum Center Plate Floor Finish ES Bronze or Stainless Center Plate
Turnbar
Turnbar Assembly W
SJPF*
SJPFW*
SJPFB/SS*
Use this cover for: Interior or exterior seismic applications where aesthetics are not a primary concern. Limited vehicular access (heavy duty models). How it works: Self centering aluminum center plate remains flush during thermal movement, but temporarily displaces and slides over floor surface during seismic movement.
1-3/8"
SJHD*
Heavy Duty 2,000 lb. Point Load
SJWHD*
Heavy Duty 2,000 lb. Point Load
SJP*
20
21
SEISMIC
Cover Details
Unique Honeycomb Structure Supports Plate Throughout Movement Cycle Also Available As A Conventional Lineal Cover, Model XYZ
Corridor Covers
FOR BASE ISOLATED STRUCTURES
This system allows full access between base isolated and fixed structures. It is perfect for where egress is necessary
during an earthquake. Because base isolated structures are
Center Pan Locked Into And Guided By Track At Base Of Side Walls
Floor/Wall Section
assembly, provides full movement of up to 100% in any horizontal direction. The floor cover may be used
independently of the wall and ceiling covers for lineal applications where lateral shear is a problem
de Young Museum, CA
How the Gyrometric Cover Works OSHPD approved designs Complies with ASTM E1399 Complimentary pre-construction design assistance Fire rating available; compliant with UL 2079 Wide range of custom finishes available Virtually any joint size/movement capability
can be accommodated
Lateral Shear The cab is attached to the fixed structure by means of a friction-free
sliding track assembly to allow full lateral shear between buildings.
22
23
Model Data
1" 0.75" 1.25" 1.0" FCF 100 2"
Ceiling Covers 3" 1.0" 4.5" 3.0" FCF 300 4" 1.0" 6.0" 4.0" FCF 400 2" 1.0" 3.0" 2.0" FCS 200 3" 1.0" 6.0" 3.0" FCS 300 4" 1.0" 8.0" 4.0" FCS 400
F LU S H
Thinline Wall
& C E I L I N G CO V E R S 1" - 10 "
Ontario Convention Center, CA
Model Data
JOINT WIDTH
Corner Wall Covers 1" 0.75" 1.25" 1.0" FWFC 100 2" 1.0" 3.0" 2.0" FWFC 200 3" 1.0" 4.5" 3.0" FWFC 300 4" 1.0" 6.0" 4.0" FWFC 400 2" 1.0" 3.0" 2.0" FWSC 200 3" 1.0" 6.0" 3.0" FWSC 300 4" 1.0" 8.0" 4.0" FWSC 400
Model Data
1" 0.75" 1.25" 1.0" FCFC 100 2"
Corner Ceiling Covers 3" 1.0" 4.5" 3.0" FCFC 300 4" 1.0" 6.0" 4.0" FCFC 400 2" 1.0" 3.0" 2.0" FCSC 200 3" 1.0" 6.0" 3.0" FCSC 300 4" 1.0" 8.0" 4.0" FCSC 400
For odd and larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com
Wall Covers
Wall Covers
Ceiling Covers
Suspended Ceiling W
Gasket
ES Suspended Ceiling ES ES ES
FWF
FWFC-M
FCF
FCFC
Use this cover for: Wall and ceiling applications to align with and match flush Thinline covers used in the floor. Suitable for most wall and ceiling finishes frame configuration variable to suit selected finish.
ES
ES
Where hygiene is important. How it works: Multi-directional flush single gasket wall and ceiling cover accommodates both thermal and seismic movement.
FWS
FWFC
Ribbed Gasket Offers Better Movement
FCS
ES
FCSC
Gasket Colors
Black White Gray Greige
24
25
F LU S H
Twinline Wall
& C E I L I N G CO V E R S 2 " - U P
National Archives II, MD
Model Data
JOINT WIDTH
Corner Wall Covers 2" 1.5" 3.5" 4.25" 4" 3.0" 6.0" 7.5" 6" 4.5" 7.75" 9.5" 8" 5.5" 10.25" 12.0" 10" 6.5" 12.75" 14.5" 12" 7.5" 15.25" 17.0" 14" 8.5" 17.75" 19.5" 16" 9.5" 20.25" 22.0" 4" 2.0" 8.0" 7.62" 6" 2.0" 12.0" 9.62" LAFC 600 8" 2.0" 16.0" 11.62" LAFC 800 10" 2.0" 20.0" 13.62" LAFC 1000 12" 2.0" 24.0" 15.62" 14" 2.0" 28.0" 17.62" 16" 2.0" 32.0" 19.62" LAFC 1600
SGWC 600 SGWC 800 SGWC 1000 SGWC 1200 SGWC 1400 SGWC 1600 LAFC 400
For odd and larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com
Wall Covers
Continuous Extruded Aluminum Frame
Wall Covers
Aluminum Panel Deflector
Turnbar
ES
LAF
GTW
Shock Cord
SGW
Ceiling Cover
Shock Cord
LAFC SGC
Aluminum Panel
Gasket Colors
Black White Gray Greige
26
27
Model Data
1" 0.0" 5.0" 2.0" HC 100
Ceiling Covers 3" 0.0" 9.0" 4.0" HC 300 4" 0.0" 10.0" 5.0" HC 400
A L LWAY M E TA L
Model Data
JOINT WIDTH
Corner Wall Covers 1" 0.63" 1.38" 2.37" AFWC 100 2" 1.25" 2.75" 4.25" AFWC 200 3" 1.5" 4.5" 6.25" AFWC 300 4" 2.5" 5.5" 7.25" AFWC 400 1" 0.5" 1.5" 1.875" ASMC 100 2" 0.5" 3.0" 3.375" ASMC 200 3" 0.5" 6.0" 6.375" ASMC 300 4" 0.5" 6.0" 6.375" ASMC 400
Model Data
1" 0.0" 5.0" 1.5" HCW 100
Corner Ceiling Covers 3" 0.0" 9.0" 3.5" HCW 300 4" 0.0" 10.0" 4.5" HCW 400
For odd and larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com
Wall Covers
Ceiling Covers
AFW
ES Continuous Extruded Aluminum Cover Plate Continuous Extruded Aluminum Center Plate
ES
AFWC
HC
Use this cover for: Interior applications to match Allway metal floor covers. Standard aluminum covers supplied clear anodized, but Kynar paint and bronze or stainless top plates available. How it works: This wall covers free-floating aluminum center plate spans joint and slides between frame assemblies to allow movement when required. Cover can be painted to match wall finish.
Continuous Extruded Wall Joint Cover Snaps Into Retaining Clip For Simple Installation W Cover Edges Gasketed For Better Fit To Wall W Suspended Acoustical Ceiling (By Others)
W ES ES
ASM
ASMC
HCW
Dual Durometer PVC White Gasket
28
29
E X T E R I O R WA L L
Flexible Seals
2" - U P
Ohio State University, OH
For odd and larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com
Wall Covers
Continuous Extruded Secondary Seal W
Wall Covers
Wall Covers
ES
SF-300
SF-800
Turnbar
Use this cover for: Exterior vertical applications where weather protection is critical. Frames designed to attach to most external skin structures. 2" to 36" joint sizes with multi-directional movement. Factory welded transitions available. Four standard gasket colors (12 standard VF colors).
VF
SC-400
Continuous Extruded Aluminum Frame
SC-1200
Model VF Colors
How it works: Flush, colorable seals for exterior applications, expand and compress during movement, while providing a weather tight seal.
Precast White Gray Limestone Sandstone
Gasket Colors
Black White Gray Greige
Natural Stone
Dusty Rose
Adobe Tan
Rustic Brick
Blue Spruce
Bronze
Charcoal
Black
30
31
SEISMIC
Exterior Wall
CO V E R S 4 " - U P
de Young Museum, CA
Model Data
JOINT WIDTH
Corner Wall Covers 8" 4.0" 16.0" 13.0" XLSC 800 10" 4.0" 20.0" 15.0" XLSC 1000 12" 4.0" 24.0" 17.0" XLSC 1200 14" 4.0" 28.0" 19.0" XLSC 1400 16" 4.0" 32.0" 21.0" XLSC 1600 4" 3.0" 7.5" 8.0" ESC 400 8" 5.0" 12.0" 13.0" ESC 800 12" 7.0" 17.5" 18.0" ESC 1200 16" 9.0" 22.5" 23.0" ESC 1600
For odd and larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com
Cycling
Wall Covers
Moisture Seal
Turnbar
Vapor Barrier
Magnet
Strike Plate
XLS Contracted
ES
XLS
ESW
SS Hinge
Wall Frame
Use this cover for: Exterior seismic wall applications where cover concealment is desired within curtain wall finishes. Lightweight finish applications up to 9/16" thick (supplied by others). Zero maintenance required after an earthquake. Where high wind loads are expected. How it works: Flush exterior wall cover releases from wall on one side to provide full seismic movement. Cover returns to closed position after an event via counterweight system.
Wall Panels Field Installed, and Supplied by Others Wall Substrate Control Assembly Frame Welded Aluminum Tube Frame W Hinge Frame
Moisture Seal
Turnbar W
Vapor Barrier
XLSC
ESC
XLS Expanded
32
33
Model Data
JOINT WIDTH
Roof Covers 2" 1.0" 3.0" 10.0" BRJ 200 4" 1.0" 6.0" 12.0" BRJ 400 6" 1.0" 9.0" 14.0" BRJ 600 8" 1.0" 12.0" 16.0" BRJ 800 10" 0.0" 15.0" 18.0" BRJ 1000 12" 0.0" 18.0" 20.0" BRJ 1200 14" 0.0" 21.0" 22.0" BRJ 1400 16" 0.0" 24.0" 24.0" BRJ 1600 4" 0.5" 8.0" 12.0" SRJ 400 6" 0.5" 11.5" 15.0" SRJ 600 8" 0.5" 13.5" 18.0" SRJ 800 10" 0.5" 17.5" 21.0" SRJ 1000 12" 0.5" 20.5" 24.0" SRJ 1200 14" 0.5" 21.5" 27.0" SRJ 1400 16" 0.5" 25.0" 30.0" SRJ 1600
Roof Covers
2" - U P
Round Valley Office Complex, NJ
SPECIFY MODEL
Model Data
JOINT WIDTH
Roof to Wall Covers 2" 1.0" 3.0" 6.0" BRJW 200 4" 1.0" 6.0" 8.0" BRJW 400 6" 1.0" 9.0" 10.0" BRJW 600 8" 1.0" 12.0" 12.0" BRJW 800 10" 1.0" 15.0" 14.0" 12" 0.0" 18.0" 16.0" 14" 0.0" 21.0" 18.0" 16" 0.0" 24.0" 20.0" 4" 2.5" 6.5" 8.0" 6" 3.5" 8.5" 10.5" SRJW 600 8" 4.5" 11.0" 13.0" SRJW 800 10" 5.5" 13.5" 15.5" 12" 6.5" 16.0" 18.0" 14" 7.5" 18.5" 20.5" 16" 8.5" 21.0" 23.0"
BRJW 1000 BRJW 1200 BRJW 1400 BRJW 1600 SRJW 400
For odd and larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com
BRJ
BRJW
Gyrometric Cover
Use this cover for: Applications in built-up, flat roofs. Joint sizes from 2" to 36" Multi-directional movement requirements. How it works: For metal roof covers, aluminum frames create a seal to the underside of sliding metal cover plates. For flexible roof joint covers, bellows material expands and contracts for multi-directional movement.
Moisture Seal Extruded Aluminum Frame Aluminum Cover Plate Turnbar Factory Fabricated End Transition Tucks Up Behind Vertical Seal Factory Fabricated Base Closure For Vertical Seal
Vapor Barrier
SRJ
SRJW
Parapet Transitions
34
35
Model Data
JOINT WIDTH
Floor to Floor Covers 4" 2.0" 6.0" 17.0" KB 400 6" 3.0" 9.0" 22.0" KB 600 8" 4.0" 12.0" 26.0" KB 800 6" 0.0" 11.0" 24.5" PTC 600 8" 0.0" 13.0" 26.5" PTC 800 10" 0.0" 16.0" 29.5" PTC 1000 12" 0.0" 19.0" 32.25" PTC 1200 14" 0.0" 22.0" 35.25" PTC 1400 16" 0.0" 25.0" 38.25" PTC 1600 4" 1.25" 5.25" 7.63"
Model Data
6" 1.25" 8.0" 11.13"
PA R K I N G
KBW400
KBW600
Model Data
JOINT WIDTH
Floor to Floor Covers 2.0" 1.0" 3.0" 9.0" ZB200 3.0" 1.5" 4.5" 10.0" ZB300 4.0" 2.0" 6.0" 11.0" ZB400 1.0" 0.6" 1.5" 1.0" HB100 2.0" 1.13" 3.0" 2.0" HB200 3.0" 1.5" 4.5" 3.0" HB300 4.0" 2.0" 6.0" 4.0" HB400 .87" 0.43" 1.25" 0.87" HBF100 1.68" .87" 2.5" 1.68" HBF200 2.56" 1.37" 3.75" 2.56" HBF300 3.43" 1.81" 5.0" 3.43" HBF400
For odd and larger sized joints, call (800) 233-8499 or visit www.c-sgroup.com
ZB
Aluminum Top Cap (Stainless Steel Optional)
HBF
Hybrid Compression Seal Incorporating Built In Reservoirs for Epoxy Adhesive
KB
No Inflation Needed For Cast-In Place Applications
Compression Seal
Vapor Barrier
Use this cover for: Seismic applications in parking and other areas with vehicular access. Available in standard or HS-20 heavy duty loading. New Cast-In-Place Model Available for post-tensioned slab applications. How it works: For a complete description call (800) 233-8493 and request a parking cover catalog or go to www.c-sgroup.com
PTC
W Extruded Aluminum Rotational Frame Vapor Barrier
PDA
HB
KBC
Extruded Aluminum Frame Elastomeric Concrete Compression Spring Aluminum Cover Plate Leveling Grout (By Others)
36
37
N O M AT T E R W H AT J O I N T CO V E R YO U N E E D,
When an expansion or seismic joint passes through a fire-rated structure it is necessary to maintain the fire integrity of that structure. Maintaining the integrity of a 2" wide joint is quite simple; however, a joint designed for seismic movement up to 24 inches becomes a more difficult proposition. In general, the wider the joint, the more complex the fire barrier. Most manufacturers use the same barrier design for all joint sizes. C/S has simplified our fire barrier for small joint sizes for easy installation and to maximize cost effectiveness (see Reflex). Floor applications are relatively simple configurations regardless of joint size unless lateral shear is required. Walls, on the other hand, can be more complex. All C/S fire barriers require only one barrier in the wall and require that the studs be
wrapped with drywall to maintain full integrity. (Includes shaft walls) Variations in wall configurations and finishes, as well as transitions between adjacent fire barriers, make it critical to consult the manufacturer concerning typical applications. C/S has a technical expert available to assist you in detailing these applications. Since 1996 building codes require fire barriers to limit the passing of heat and flame for 2, 3 and sometimes 4 hours, as well as accommodating the dynamic movement for which the joint was designed. ASTM E 1966 and UL 2079 specify criteria for cycling a fire barrier 500 times prior to fire testing. C/S tests all of its fire barriers at Underwriters Laboratories (UL) because they represent the most stringent and universally accepted testing authority.
C/S MODEL GYPSUM WALL RFX-1W (GYP.) RFX-1W (1 HR GYP.) RFX-2W (GYP.) RFX-2W (1 HR GYP.)
C/S MODEL MASONRY WALL RFX-1W(CONC) RFX-1W(1 HR CONC.) RFX-2W(CONC) RFX-2W(1 HR CONC.)
Multiflex 3"-12"
Sandwich assembly of layers of stainless steel foil and insulation contained in a stainless steel mesh. Standard barrier allows up to 50% lateral shear in floor applications.
NOMINAL JOINT WIDTH 3-6 7-12 C/S MODEL FLOORS MFX-3F-6F MFX-7F-12F C/S UL NUMBER FLOOR FF-D-1066 FF-D-2009 C/S MODEL GYPSUM WALL MFX-3W-6W(GYP) MFX-7W-12W(GYP) C/S UL NUMBER GYPSUM WALL WW-D-1056 WW-D-2011 C/S MODEL MASONRY WALL MFX-3W-6W(CONC) MFX-7W-12W(CONC) C/S UL NUMBER MASONRY WALL WW-D-1057 WW-D-2012
FB97 13"-Up
Multiple drape configurations of stainless foil and insulation utilizing air pockets for additional insulation performance. Sliding frame available for 100% lateral shear applications in floors.
NOMINAL JOINT WIDTH 13-24 25-36 13-24 25-36 C/S MODEL FLOORS FB97-13-24 FB97-25-36 FB97-13(LS)-24(LS) FB97-25(LS)-36(LS) C/S UL NUMBER FLOOR FF-D-3005 FF-D-4001 FF-D-3006 FF-D-4002 C/S MODEL GYPSUM WALL FB97-13-24(GYP) NA NA NA C/S UL NUMBER GYPSUM WALL WW-D-3007 NA NA NA C/S MODEL MASONRY WALL FB97-13-24(CONC) NA NA NA C/S UL NUMBER MASONRY WALL WW-D-3008 NA NA NA
LS designation indicates a special adaptation of the floor fire barrier to accommodate Lateral Shear movement. FB-97 wall fire barriers naturally provide lateral shear movement.
6696 State Route 405, Muncy, Pennsylvania 17756 U.S.A., 570-546-5941 895 Lakefront Promenade, Mississauga, Ontario L5E 2C2 Canada, 905-274-3611
www.c-sgroup.com
The C/S Family of Products For more than 60 years, Construction Specialties has been a leader in architectural specialty products, including: Acrovyn Wall and Door Protection, Pedisystems Entrance Flooring, Expansion Joint Covers, Cubicle Track and Curtains, Smoke and Explosion Venting Systems, Architectural Grilles, Architectural Louvers and Sun Controls.
We have operations throughout the world and can provide C/S Products virtually anywhere. For a complete list of our international locations, visit www.c-sgroup.com.
For the nearest C/S representative, or literature and samples, call toll free 800-233-8493 in U.S.A. and 888-895-8955 in Canada, or visit www.c-sgroup.com
Copyright 2009 Construction Specialties, Inc. Construction Specialties, Inc. reserves the right to make design changes or to withdraw any design without notice. Printed in U.S.A. Series 10