Sunteți pe pagina 1din 21

07 95 00/CON BuyLine 1803

C/S Expansion Joints @ The Cathedral of Christ the Light

P A S A D E N A

C I T Y

H A L L

C/S Expansion Joint Covers on the job

An 80 year old architectural icon gets a seismic makeover.


Pasadena City Hall was built in 1927 to inspire a city with beauty, boldness and vision. It is an important part of this communitys rich architectural heritage. It is one of the finest examples of the California Mediterranean style. Designed by Bakewell and Brown in San Francisco, the 80 year old Pasadena City Hall is one of the most

C/S Stone Paver Seismic Covers allow the Pasadena City Hall to move 30"
For the seismic upgrade of the Pasadena City Hall ARG architects specified 33" SSRW Seismic Stone Paver Floor Covers to fill the moat area surrounding the buildings perimeter in its inner courtyard. The covers provide full four way movement and are designed to work in conjunction with the base isolators when a seismic event occurs.

distinctive public buildings in the United States and is listed on the


National Register of Historic Places. One of the primary reasons for the seismic retrofit of Pasadena City Hall was that studies in the 1990s indicated that major earthquakes in the future could destroy several parts of the building completely and result in loss of life. In 2003, the City Council approved a plan for the seismic

retrofit and historic restoration. Seismic retrofit of the building included the installation of structural base isolators that now allow the
building to withstand future earthquake activity. Restoration activities were undertaken topreserve many of the historic architectural elements of City Hall.

Pasadena City Hall achieves LEED Gold status


Along with the seismic upgrade, the City of Pasadena requested that the building be LEED Certified. The design team used sustainable strategies throughout the project. Even the C/S expansion joint covers in the patio area are hidden beneath a 4" layer of decomposed granite.

Architect: Architectural Resources Group (ARG) San Francisco, CA Construction Manager: DM-JMH+N Contractor: Clark Construction Group

C/S

E X P A N S I O N

J O I N T

C O V E R S

No matter how much movement your project requires, we can hide it.
C/S @ de Young Museum
A major consideration of the de Young project was that the expansion joint covers must be virtually invisible within the museums weathered copper skin. Architects Fong & Chan, SF; and Herzog & de Meuron specified CS XLS cover system knowing it could be seamlessly incorporated into the facades copper panel frame. The 24" XLS covers are designed to release from the wall to provide full seismic movement.

C/S @ Orange County Performing Arts Center


In the interior of the magnificent Segerstrom Concert Hall, Architect Pelli Clarke Pelli specified C/S 12" LAF Seismic Wall Covers. Virtually imperceptible the LAF wall covers are lightweight, match the concert halls wall finish without visual interruption and provide full movement of the joint without damage to surrounding wall surfaces.

San Francisco International Airport


Architect: Skidmore, Owings & Merrill Throughout San Francisco International Airports base isolated main terminal, massive C/S wall floor and ceiling covers provide four way movement up to 60" while being virtually invisible. The SSR Stone Paver floor joints are 200' long and provide 36" of movement.

Newseum
Architect: Polshek Partnership To provide movement and security between the Newseum and the adjacent Canadian Embassy, Polshek Partnership specified SC-1200 Exterior Covers and SRJ-1200 Roof Covers that tie both buildings together. The covers with factory mitered transitions are attached to the buildings delicate marble surface.

C/S

E X P A N S I O N

J O I N T

C O V E R S

Solving complex building movement problems for 40 years


Utah State Capitol Building
Project Manager: Parsons Corporation A seismic upgrade was required for this landmark building. Parsons specified C/S Gyrometric cabs (Model MACC) and SSRW Seismic moat covers to provide egress from the building during seismic activity.

Center for the Intrepid Armed Forces Physical Rehabilitation Center


Architect: The Smith Group C/S supplied unobtrusive SM-2 Wall Covers to match blend surrounding wall surfaces and to provide multi-directional thermal movement in order to keep the facility walls from cracking.

Selection Chart
This catalog is designed to convey the design concept and variations available with C/S joint cover systemsfor more accurate details go to: www.c-sgroup.com

Floor Covers
The size of joint and movement dynamics dictate whether you require a standard or seismic expansion joint cover system. Before making a selection, there are other decisions you must make. The selection of the floor cover is often the most critical step in the specification process since the performance of the floor cover has the greatest impact on the occupants of the building. The presence of rolling loads and the need for hygiene are major considerations in cover selection, while aesthetics in seismic covers is also a significant issue.

Wall & Ceiling Covers


Having selected the floor cover, identifying a matching wall cover is a relatively simple task. When it comes to seismic covers, however, there are options driven by both functionality and aesthetics. Choose from covers that become detached from the wall to minimize damage or ones that are self-closing to minimize post-event maintenance. Many of our wall covers are designed to accept a range of surface materials to maximize concealment of the cover.

Specialty Covers
Specialty covers, such as roof covers and vehicular joint systems, are available for most joint sizes and movement dynamics.

Cover Type

Flush Thinline Gasketed

Flush Twinline Dual Gasketed

Flush Seismic, Seismic Pan

Standard Allway Metal

Seismic Allway Metal

Seismic Corridor Cover

Flush Thinline Gasketed

Flush Twinline Dual Gasketed

Seismic Flush Twinline

Allway Metal

Exterior Wall

Roof

Parking & Stadiums

Appearance

Joint Size

1" and 2"

2" to 4"

4" and up

1" to 4"

4" and up

4" to 36"

1" to 4"

2" and up

4" and up

1" to 4"

2" and up

2" and up

1" to 16"

Description

Minimum exposed surface, sealed gasket installation

Minimum exposed surface, sealed gasket installation, larger movement

Minimum exposed surface, optional sealed gasket installation, seismic movement

Robust applications, low maintenance

Robust applications, low maintenance, seismic movement

Corridors in base isolated structures with multi-directional movement

Minimum exposed surface, sealed gasket installation

Minimum exposed surface, sealed gasket installation, larger movement

Minimum exposed surface, optional sealed gasket installation, seismic movement

Robust applications, low maintenance, full movement range

Minimum exposed surface, sealed gasket installation, full movement range

Formed aluminum and EPDM bellows options, full movement range

Exterior, waterproof applications, full movement range

Finishes
Carpet, vinyl, ceramic tile, terrazzo, stone Carpet, vinyl Carpet, vinyl, terrazzo, stone Concrete, carpet, vinyl Concrete, pavers, carpet, vinyl, ceramic tile Carpet, vinyl Drywall, ceramic tile Drywall, ceramic tile Drywall, panel systems, metal cladding, stone All finishes All finishes All roof finishes Concrete, paver

Designed For

Hygienic, wheeled equipment

Hygienic, wheeled equipment

Hygienic, wheeled equipment, deep floor finish materials, also exterior

Industrial, heavy wheeled equipment

Industrial, heavy wheeled equipment, also exterior

Commercial and healthcare interiors

Hygienic, matches Thinline floor covers

Hygienic, matches Twinline floor covers

All commercial and healthcare interiors and exteriors

Industrial, matches Allway floor covers

All exteriors, colorable

All roofs

Vehicular traffic, stadium seating bowls and concourse

% Movement +/-

25% Of Joint Width

50% Of Joint Width

50-100% Of Joint Width

50-100% Of Joint Width

50-100% Of Joint Width

50-100% Of Joint Width

25-100% Of Joint Width

50-100% Of Joint Width

50-100% Of Joint Width

50-100% Of Joint Width

50-100% Of Joint Width

50-100% Of Joint Width

25-100% Of Joint Width

Page #

10-11

12-13

14-17

18-19

20-21

22-23

24-25

26-27

26-27

28-29

30-33

34-35

36-37

Matching Floor

N/A

N/A

N/A

N/A

N/A

N/A

8-9

10-11

12-15

16-17

N/A

N/A

N/A

Wall/Ceiling
24-25 24-25 26-27 28-29 26-27 22-23 N/A N/A N/A N/A N/A N/A N/A

Fire Barriers
Reflex Page 39 Multiflex Page 39 Multiflex or FB-97 Page 39 Reflex Page 39 Multiflex Page 39 FB-97 Page 39 Reflex Page 39 Multiflex Page 39 Multiflex or FB-97 Page 39 Reflex or Multiflex Page 39 Contact Factory Contact Factory Contact Factory

Cost Index
65 105 125 100 100 N/A 55 180 N/A 100 150 N/A N/A

All C/S Expansion Joint Covers, Seals and Processes are ISO 9001: 2000 compliant.

100

By assigning our metal systems a cost of 100, you can determine how much an alternate system of similar size will cost.

Model Data
JOINT WIDTH

Floor to Floor Covers 1" 0.75" 1.25" 1.25" GFT 100 2" 1.5" 2.5" 1.88" GFT 200 1" 0.75" 1.25" 1.18" GFPS 100 2" 1.5" 2.5" 1.88" GFPS 200 1" 0.75" 1.25" 4.31" GFS 100 2" 1.5" 2.5" 5.13" GFS 200 1" 0.75" 1.25" 4.31" GFST 100 2" 1.5" 2.5" 5.06" GFST 200

MINIMUM OPENING MAXIMUM OPENING

F LU S H

EXPOSED SURFACE SPECIFY MODEL

Thinline Floor
CO V E R S 1" - 2 "
Miami International Airport, FL

Model Data
JOINT WIDTH

Floor to Wall Covers 1" 0.75" 1.25" 1.12" GFTW 100 2" 1.5" 2.5" 1.88" GFTW 200 1" 0.75" 1.25" 1.18" GFPSW 100 2" 1.5" 2.5" 1.88" GFPSW 200 1" 0.75" 1.25" 2.63" GFSW 100 2" 1.5" 2.5" 3.56" GFSW 200 1" 0.75" 1.25" 2.63" GFSTW 100 2" 1.5" 2.5" 3.56" GFSTW 200

MINIMUM OPENING MAXIMUM OPENING EXPOSED SURFACE SPECIFY MODEL

For odd and larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com

Floor Covers

Floor to Wall Covers


ES Non-Shrink Grout ES Gasket Continuous Extruded Aluminum Wall Frame

Floor Covers

Floor Finish Carpet ES ES

1"-3"

1"-3"

GFT-100

Continuous Extruded Aluminum Frame

GFTW-100

GFPS-100

Continuous Extruded Aluminum Frame

GFST-200

ES

Use this cover for: Applications with small, interior joints where minimal visual impact is preferred. Suitable for most floor finishes. Frame depth and configuration is variable to suit selected finish. Where wheeled equipment is to be used. Where hygiene is important. How it works: Single gasket expands and compresses during movement. 2" model includes aluminum support plate for added durability.

Non-Shrink Grout ES Gasket

Floor Finish

Continuous Extruded Aluminum Wall Frame ES

Carpet

ES

1"-3"

1"-3"

Continuous Extruded Central Plate W

GFT-200

Continuous Extruded Aluminum Frame

GFTW-200

GFPS-200

GFS-200

Gasket Colors
Black White Gray Greige

Note: Custom colors available. Call 800-233-8493.

10

For comprehensive information on these products, visit www.c-sgroup.com/expansion-joint-covers

11

Model Data
JOINT WIDTH

Floor to Floor Covers


2" 1.0" 3.0" 6.5" GTR 200 3" 1.5" 4.5" 10.0" GTR 300 4" 2.0" 6.0" 11.0" GTR 400 2" 1" 3" 6.5" GTR-HD 200 3" 1.5" 4.5" 10" GTR-HD 300 4" 2" 6" 11" GTR-HD 400 2" 1.0" 3.0" 6.5" GTP 200 3" 1.5" 4.5" 10.0" GTP 300 4" 2.0" 6.0" 11.0" GTP 400

MINIMUM OPENING MAXIMUM OPENING

F LU S H

EXPOSED SURFACE SPECIFY MODEL

Twinline Floor
CO V E R S 2" - 4 "
Inova Fairfax Hospital, VA

Model Data
JOINT WIDTH

Floor to Wall Covers 2" 1.5" 2.5" 4.25" GTRW 200 3" 2.25" 3.75" 6.5" GTRW 300 4" 3.0" 5.0" 7.5" GTRW 400 2" 1.5" 2.5" 4.31" GTPW-HD 200 3" 2.25" 3.75" 6.56" GTPW-HD 300 4" 3.0" 5.0" 7.56" GTPW-HD 400 2" 1.5" 2.5" 4.25" GTPW 200 3" 2.25" 3.75" 6.5" GTPW 300 4" 3.0" 5.0" 7.5" GTPW 400

MINIMUM OPENING MAXIMUM OPENING EXPOSED SURFACE SPECIFY MODEL

For odd and larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com

Floor Covers
Gasket Continuous Extruded Aluminum Recessed Center Plate Floor Finish Matching (By Others)

Floor to Wall Covers


ES

Floor Cover
Heavy Duty 2,000 lb. Point Load 1/4" Aluminum Center Plate ES

ES 5/8" 5/8" 3/4"

GTR

W Continuous Extruded Aluminum Frame

GTRW

GTR-HD
(Heavy Duty)

Heavy Duty Frame

Gasket

Continuous Extruded Aluminum Flush Center Plate ES

ES

ES

Use this cover for: Applications with larger thermal movement requirements and where a flush, concealed cover is preferred. Applications using carpet or vinyl floor covering up to 1/8" deep. 3/8 Recessed center plate available. Where wheeled equipment is expected. Where hygiene is important. How it works: Dual gaskets allow for greater expansion and compression during movement. Durable aluminum plate spans joint opening.
GTP
5/8" Floor Finish (By Others)

5/8"

3/4"

Continuous Extruded Aluminum Frame

GTPW

GTPW-HD
(Heavy Duty)

Gasket Colors
Black White Gray Greige

Note: Custom colors available. Call 800-233-8493.

12

For comprehensive information on these products, visit www.c-sgroup.com/expansion-joint-covers

13

Model Data
JOINT WIDTH

Floor to Floor Covers 5" 2.5" 8.0" 12.0" SGR 500 6" 2.5" 9.0" 13.0" SGR 600 7" 2.5" 11.0" 15.0" SGR 700 8" 3.0" 12.0" 16.0" SGR 800 9" 3.0" 14.0" 18.0" SGR 900 10" 3.0" 15.0" 19.0" SGR 1000 11" 3.0" 17.0" 21.0" SGR 1100 12" 3.0" 18.0" 22.0" SGR 1200 13" 3.0" 20.0" 24.0" SGR 1300 14" 3.0" 21.0" 25.0" SGR 1400 15" 3.0" 23.0" 27.0" SGR 1500 16" 3.0" 24.0" 28.0" SGR 1600

MINIMUM OPENING MAXIMUM OPENING

F LU S H

EXPOSED SURFACE SPECIFY MODEL

Seismic Floor
CO V E R S 5" - U P
40 Bank Street, London

Model Data
JOINT WIDTH

Floor to Wall Covers 5" 4.0" 7.0" 8.5" SGRW 500 6" 4.5" 8.0" 9.5" SGRW 600 7" 5.25" 9.5" 11.0" SGRW 700 8" 5.5" 10.5" 12.0" SGRW 800 9" 5.75" 12.0" 13.5" SGRW 900 10" 6.25" 13.0" 14.5" SGRW 1000 11" 6.75" 14.5" 16.0" SGRW 1100 12" 7.25" 15.5" 17.0" SGRW 1200 13" 7.75" 17.0" 18.5" SGRW 1300 14" 8.25" 18.0" 19.5" SGRW 1400 15" 8.75" 19.5" 21.0" SGRW 1500 16" 9.25" 20.5" 22.0" SGRW 1600

MINIMUM OPENING MAXIMUM OPENING EXPOSED SURFACE SPECIFY MODEL

SGR and SGP have same model data. SGRW and SGPW have same model data. For odd and larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com

Cycling
Plate Deflectors Ensure System Remains Operable through Major Seismic Activity

Floor Covers
Turnbar Rotates and Keeps Plate Centered During Movement Cycle ES 3/4" 3/4"

Floor to Wall Covers


Hinged Side Frame

ES

SGR Contracted

SGR*

SGRW

Hinged Side Frame Gaskets Disengage to Allow Full Seismic Movement

Use this cover for:


3/4"

ES 3/4"

ES

Seismic interior applications requiring a completely flush joint cover virtually concealed in the surrounding floor finishes. Applications using carpet or vinyl floor covering up to 1/8" deep. Where wheeled equipment is expected. Where hygiene is important. How it works: Dual gaskets expand and contract during minor thermal movement. During full seismic activity, gaskets disengage and the aluminum center plate that spans the joint opening temporarily displaces.
SGR Expanded SGP*
W

SGPW

Gasket Colors
Black White Gray Greige

Note: Custom colors available. Call 800-233-8493.

*Can be modified to provide up to 100% movement

14

For comprehensive information on these products, visit www.c-sgroup.com/expansion-joint-covers

15

Model Data
JOINT WIDTH

Floor to Floor Covers 2" 1.0" 3.0" 10.88" SSR 200 4" 2.5" 9.0" 12.88" SSR 400 6" 3.0" 11.0" 14.88" SSR 600 8" 4.0" 12.5" 18.6" SSR 800 10" 4.0" 15.5" 20.5" SSR 1000 12" 4.0" 18.5" 23.75" SSR 1200 14" 4.0" 21.5" 26.75" SSR 1400 16" 4.0" 24.5" 32.75" SSR 1600

MINIMUM OPENING MAXIMUM OPENING

PA N

EXPOSED SURFACE SPECIFY MODEL

Seismic Floor
CO V E R S 4 " - U P
San Francisco International Airport, CA

Model Data
JOINT WIDTH

Floor to Wall Covers 2" 1.0" 3.0" 6.44" SSRW 200 4" 1.5" 6.5" 8.44" SSRW 400 6" 2.0" 8.5" 10.44" SSRW 600 8" 4.0" 10.25" 14.38" SSRW 800 10" 4.0" 12.75" 16.88" SSRW 1000 12" 4.0" 15.25" 19.38" SSRW 1200 14" 4.0" 17.75" 21.88" SSRW 1400 16" 4.0" 20.25" 24.32" SSRW 1600

MINIMUM OPENING MAXIMUM OPENING EXPOSED SURFACE SPECIFY MODEL

For odd and larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com

Cycling

Floor Covers

Floor to Wall Covers

Center Pan Lifts Clear Of Moving Structure But Remains Centered Over Opening

Sealant and Backer

Infill Material

Extruded Aluminum Center Pan ES

Continuous Aluminum Pan Nosing

Aluminum Hinge ES 2-1/4"

2-1/4"

SSR Contracted

W Continuous Aluminum Frame

SSR-200-600

SSRW-400

Use this cover for: Interior and exterior seismic applications where cover concealment is desired in deeper floor finishes. Applications with floor finishes of up to 1-1/2" thick. Heavy duty versions available for limited vehicular access. How it works: Sealant and Backer Rod expand and contract for minor thermal movement. During seismic activity the center pan assembly lifts for additional movement and returns to normal position after event.
SSR Expanded SSR-800
W Unique Gravity Activated Turnbar System Returns Cover To Normal Position After Event Modular Pan Construction For High Strength ES 2-1/4" 2-1/4" Unit Sealed With Standard Caulking Can be used As Moat Cover For Base Isolated Structures ES

SSRW-800

16

For comprehensive information on these products, visit www.c-sgroup.com/expansion-joint-covers

17

Model Data
JOINT WIDTH

Floor to Floor Covers 1" .7" 1.2" 1.7" APF 25 2" 1.5" 2.5" 3.25" APF 50 4" 3.1" 4.7" 5.25" APF 100 2" 0.0" 4.0" 3.65" ALR 200 4" 1.0" 7.0" 6.43" ALR 400 2" 0.0" 4.0" 7.75" ALS 200 4" 1.0" 7.0" 11.75" ALS 400 2" 0" 4.0" 9.00" AL 200/HD 4" 1.0" 7.0" 12.50" AL 400/HD 2" 0.0" 3.5" 5.25" PC 200 4" 0.0" 6.5" 8.25" PC 400 2" 1.0" 3.0" .081" FYW 200 4" 2.5" 5.5" 1.25" FYW 400

MINIMUM OPENING MAXIMUM OPENING

S TA N DA R D A L LWAY

EXPOSED SURFACE SPECIFY MODEL

Metal Floor
CO V E R S 1" - 4 "
Chek Lap Kok Airport, Hong Kong

Model Data
JOINT WIDTH

Floor to Wall Covers 2" 1.0" 3.0" 2.82" ALRW 200 4" 2.5" 5.5" 5.18" ALRW 400 2" 1.0" 3.0" 4.87" ALSW 200 4" 2.5" 5.5" 7.87" ALSW 400 2" 1.0" 3.0" 6.75" ALW 200/HD 4" 2.0" 5.5" 8.25" ALW 400/HD 2" 0.0" 3.5" 3.75" PCW 200 4" 0.0" 6.5" 6.75" PCW 400 2" 1.0" 3.0" .081" FYWW 200 4" 2.5" 5.5" 1.25" FYWW 400

MINIMUM OPENING MAXIMUM OPENING EXPOSED SURFACE SPECIFY MODEL

For odd and larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com

Floor Covers

Floor Covers
1/8 Floor Finish (By Others) Continuous Extruded Aluminum Center Plate ES 1" 1"

Floor to Wall Covers


Continuous Extruded Aluminum Plate For Carpet/Vinyl Recessed Cover Plate ES Continuous Extruded Aluminum Floor To Wall Frame

Continuous Extruded Aluminum Cover Plate ES

Continuous Extruded Aluminum Center Plate Insert

APF

Extruded Aluminum Frame

ALR

Continuous Extruded Aluminum Frame

ALRW
Continuous Extruded Aluminum Serrated Plate ES

Continuous Extruded Aluminum Serrated Cover Plate ES

Continuous Extruded Aluminum Frame

Continuous Extruded Aluminum Center Plate ES 1"

Serrated Side Plates Create A More Flush Surface, But Impact Visibility

Continuous Extruded Aluminum Floor To Wall Frame

Use this cover for: Use APF Series for applications with heavy rolling loads. Interior applications where low maintenance is desirable or for tamperproof applications. Suitable for most floor finishes frame configuration variable to suit selected finish.

1"

1"

AL-HD

W Specify Heavy Duty Model AL-HD For 2000 lb. Rolling Loads

ALS

W Extruded Aluminum Frame Continuous Extruded Aluminum Cover Plate ES

ALSW

ES Continuous Extruded Aluminum Floor To Wall Cover Plate

1/4 & 1/8 Carpet

How it works: Free-floating aluminum center plate spans joint and slides between frame assemblies to allow movement when required.
1"

ES

Gasket Colors
FYW
W W

PC

PCW

Note: All joint systems on this page are available for 1"-4" joints. Contact factory if required size is not listed.

18

For comprehensive information on these products, visit www.c-sgroup.com/expansion-joint-covers

19

Model Data
JOINT WIDTH

Floor to Floor Covers 4" 2.0" 6.0" 8.75" SJ-HD400 6" 3.0" 9.0" 11.75" SJ-HD600 8" 3.0" 13.0" 14.75" SJ-HD800 2" 1.0" 3.5" 5.5" SJPF 200 4" 1.0" 6.5" 8.5" SJPF 400 6" 1.0" 9.75" 11.5" SJPF 600 2" 1.0" 4.38" 3.5" SJP 200 4" 1.0" 7.0" 7.5" SJP 400 6" 1.0" 11.5" 11.88" SJP 600 8" 1.0" 13.5" 15.0" SJP 800 10" 1.0" 17.0" 17.88" SJP 1000 12" 1.0" 20.0" 21.0" SJP 1200 14" 1.0" 23.0" 23.88" SJP 1400 16" 1.0" 25.5" 27.0" SJP 1600

MINIMUM OPENING MAXIMUM OPENING

S E I S M I C A L LWAY

EXPOSED SURFACE SPECIFY MODEL

Metal Floor
CO V E R S 4 " - U P
Banner Gateway Medical Center, AZ

Model Data
JOINT WIDTH

Floor to Wall Covers 4" 3.0" 5.0" 6.38" 6" 4.25" 7.5" 8.88" 8" 5.0" 10.5" 12.38" 2" 1.0" 3.0" 3.75" SJPFW 200 4" 1.0" 5.25" 6.25" SJPFW 400 6" 1.0" 7.88" 8.75" SJPFW 600 2" 0.5" 3.13" 3.24" SJPW 200 4" 2.25" 5.5" 5.75" SJPW 400 6" 3.25" 8.5" 9.0" SJPW 600 8" 4.38" 11.0" 11.5" SJPW 800 10" 5.38" 13.5" 14.0" SJPW 1000 12" 6.38" 16.0" 16.5" SJPW 1200 14" 7.38" 18.5" 19.0" SJPW 1400 16" 8.38" 21.0" 21.5" SJPW 1600

MINIMUM OPENING MAXIMUM OPENING EXPOSED SURFACE SPECIFY MODEL

SJW-HD400 SJW-HD600 SJW-HD800

For odd and larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com

Floor Covers

Floor to Wall Covers

Floor Covers

ES Non-Shrink Grout Continuous Extruded Aluminum Side Frame ES 1-1/8" 1-1/8" 1-1/8" Aluminum Center Plate Floor Finish ES Bronze or Stainless Center Plate

Turnbar

Turnbar Assembly W

SJPF*

Continuous Extruded Aluminum Frame

SJPFW*

SJPFB/SS*

Use this cover for: Interior or exterior seismic applications where aesthetics are not a primary concern. Limited vehicular access (heavy duty models). How it works: Self centering aluminum center plate remains flush during thermal movement, but temporarily displaces and slides over floor surface during seismic movement.
1-3/8"

Continuous Extruded Aluminum HD Frame ES

ES Heavy Duty Frame Formed Aluminum Center Plate

Aluminum Center Plate May be Bronze or Stainless Steel ES 1-3/8" 1-1/2"

SJHD*
Heavy Duty 2,000 lb. Point Load

Continuous Extruded Aluminum Frame

SJWHD*
Heavy Duty 2,000 lb. Point Load

SJP*

*Can be modified to provide up to 100% movement.

20

For comprehensive information on these products, visit www.c-sgroup.com/expansion-joint-covers

21

SEISMIC

Cover Details
Unique Honeycomb Structure Supports Plate Throughout Movement Cycle Also Available As A Conventional Lineal Cover, Model XYZ

Corridor Covers
FOR BASE ISOLATED STRUCTURES

Typical Floor Section

This system allows full access between base isolated and fixed structures. It is perfect for where egress is necessary
during an earthquake. Because base isolated structures are

free to move in any horizontal direction, they create


distinct challenges for the design of the seismic joint covers. The C/S solution for base isolated structures is an integrated assembly approach with floor, wall and ceiling covers connected and moving in unison. This Gyrometric System, or cab

Center Pan Locked Into And Guided By Track At Base Of Side Walls

Floor/Wall Section

assembly, provides full movement of up to 100% in any horizontal direction. The floor cover may be used
independently of the wall and ceiling covers for lineal applications where lateral shear is a problem
de Young Museum, CA

(specify model XYZ).

How the Gyrometric Cover Works OSHPD approved designs Complies with ASTM E1399 Complimentary pre-construction design assistance Fire rating available; compliant with UL 2079 Wide range of custom finishes available Virtually any joint size/movement capability
can be accommodated

Full Open (During Tension) During an event in the expansion


or tension mode the cab slides fully out.

Full Closed (During Compression) During an event in the


contraction or compression mode the cab slides fully into the adjoining structure.

Lateral Shear The cab is attached to the fixed structure by means of a friction-free
sliding track assembly to allow full lateral shear between buildings.

22

For comprehensive information on these products, visit www.c-sgroup.com/expansion-joint-covers

23

Model Data Wall to Wall Covers


JOINT WIDTH MINIMUM OPENING MAXIMUM OPENING 1" 0.75" 1.25" 1.0" FWF 100 2" 1.0" 3.0" 2.0" FWF 200 3" 1.0" 4.5" 3.0" FWF 300 4" 1.0" 6.0" 4.0" FWF 400 2" 1.0" 3.0" 2.0" FWS 200 3" 1.0" 6.0" 3.0" FWS 300 4" 1.0" 8.0" 4.0" FWS 400

Model Data
1" 0.75" 1.25" 1.0" FCF 100 2"

Ceiling Covers 3" 1.0" 4.5" 3.0" FCF 300 4" 1.0" 6.0" 4.0" FCF 400 2" 1.0" 3.0" 2.0" FCS 200 3" 1.0" 6.0" 3.0" FCS 300 4" 1.0" 8.0" 4.0" FCS 400

1.0" 3.0" 2.0" FCF 200

F LU S H

EXPOSED SURFACE SPECIFY MODEL

Thinline Wall
& C E I L I N G CO V E R S 1" - 10 "
Ontario Convention Center, CA

Model Data
JOINT WIDTH

Corner Wall Covers 1" 0.75" 1.25" 1.0" FWFC 100 2" 1.0" 3.0" 2.0" FWFC 200 3" 1.0" 4.5" 3.0" FWFC 300 4" 1.0" 6.0" 4.0" FWFC 400 2" 1.0" 3.0" 2.0" FWSC 200 3" 1.0" 6.0" 3.0" FWSC 300 4" 1.0" 8.0" 4.0" FWSC 400

Model Data
1" 0.75" 1.25" 1.0" FCFC 100 2"

Corner Ceiling Covers 3" 1.0" 4.5" 3.0" FCFC 300 4" 1.0" 6.0" 4.0" FCFC 400 2" 1.0" 3.0" 2.0" FCSC 200 3" 1.0" 6.0" 3.0" FCSC 300 4" 1.0" 8.0" 4.0" FCSC 400

MINIMUM OPENING MAXIMUM OPENING EXPOSED SURFACE SPECIFY MODEL

1.0" 3.0" 2.0" FCFC 200

For odd and larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com

Wall Covers

Wall Covers

Ceiling Covers

Corner Ceiling Covers

W Continuous Aluminum Frame Feathered Joint Cement

Suspended Ceiling W

Gasket

ES Suspended Ceiling ES ES ES

Continuous Aluminum Frame

FWF

FWFC-M

FCF

Continuous Extruded Aluminum Frame

FCFC

Corner Wall Covers


W W Continuous Aluminum Frame Feathered Joint Cement Continuous Extruded Aluminum Frame Suspended Ceiling W Suspended Ceiling W

Use this cover for: Wall and ceiling applications to align with and match flush Thinline covers used in the floor. Suitable for most wall and ceiling finishes frame configuration variable to suit selected finish.
ES

ES

ES Feathered Joint Cement

Where hygiene is important. How it works: Multi-directional flush single gasket wall and ceiling cover accommodates both thermal and seismic movement.

FWS

FWFC
Ribbed Gasket Offers Better Movement

FCS

Continuous Extruded Aluminum Frame

ES

FCSC

Gasket Colors
Black White Gray Greige

Note: Custom colors available. Call 800-233-8493.

24

For comprehensive information on these products, visit www.c-sgroup.com/expansion-joint-covers

25

Model Data Wall Covers


JOINT WIDTH MINIMUM OPENING MAXIMUM OPENING 2" 1.0" 3.0" 6.5" GTW 200 4" 2.0" 6.0" 11.0" GTW 400 6" 3.0" 9.0" 13.0" SGW 600 8" 3.0" 12.0" 16.0" SGW 800 10" 3.0" 15.0" 19.0" SGW 1000 12" 3.0" 18.0" 22.0" SGW 1200 14" 3.0" 21.0" 25.0" SGW 1400 16" 3.0" 24.0" 28.0" SGW 1600 4" 1.0" 8.0" 11.13" LAF 400 6" 1.0" 12.0" 13.13" LAF 600 8" 1.0" 16.0" 15.13" LAF 800 10" 1.0" 20.0" 17.13" LAF 1000 12" 1.0" 24.0" 19.13" LAF 1200 14" 1.0" 28.0" 21.13" LAF 1400 16" 1.0" 32.0" 23.13" LAF 1600

F LU S H

EXPOSED SURFACE SPECIFY MODEL

Twinline Wall
& C E I L I N G CO V E R S 2 " - U P
National Archives II, MD

Model Data
JOINT WIDTH

Corner Wall Covers 2" 1.5" 3.5" 4.25" 4" 3.0" 6.0" 7.5" 6" 4.5" 7.75" 9.5" 8" 5.5" 10.25" 12.0" 10" 6.5" 12.75" 14.5" 12" 7.5" 15.25" 17.0" 14" 8.5" 17.75" 19.5" 16" 9.5" 20.25" 22.0" 4" 2.0" 8.0" 7.62" 6" 2.0" 12.0" 9.62" LAFC 600 8" 2.0" 16.0" 11.62" LAFC 800 10" 2.0" 20.0" 13.62" LAFC 1000 12" 2.0" 24.0" 15.62" 14" 2.0" 28.0" 17.62" 16" 2.0" 32.0" 19.62" LAFC 1600

MINIMUM OPENING MAXIMUM OPENING EXPOSED SURFACE SPECIFY MODEL

GTWC 200 GTWC 400

SGWC 600 SGWC 800 SGWC 1000 SGWC 1200 SGWC 1400 SGWC 1600 LAFC 400

LAFC 1200 LAFC 1400

For odd and larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com

Wall Covers
Continuous Extruded Aluminum Frame

Wall Covers
Aluminum Panel Deflector

Turnbar

Gasket Disengages To Allow Seismic Movement

ES Gasket Continuous Extruded Aluminum Cover To Match Wall Finish

ES

ES Continuous Extruded Aluminum Frame

LAF

GTW

Aluminum Honey Comb Panel

Shock Cord

SGW

Continuous Extruded Aluminum Frame

Corner Wall Covers


Use this cover for: Wall and ceiling applications to match flush Twinline covers used in the floor. Suitable for most wall and ceiling finishes. How it works: Dual gaskets expand and compress during movement, durable aluminum center plate can be painted to match wall finish and temporarily displaces during seismic events.
GTWC
ES Continuous Extruded Aluminum Frame Gasket Continuous Extruded Aluminum Center Plate

Corner Wall Covers


Aluminum Panel Deflector

Ceiling Cover

Turnbar Continuous Formed Aluminum Frame Continuous Extruded Aluminum Frame ES ES

Shock Cord

LAFC SGC

Aluminum Panel

Gasket Colors
Black White Gray Greige

Note: Custom colors available. Call 800-233-8493.

26

For comprehensive information on these products, visit www.c-sgroup.com/expansion-joint-covers

27

Model Data Wall Covers


JOINT WIDTH MINIMUM OPENING MAXIMUM OPENING 1" 0.25" 1.75" 5.0" AFW 100 2" 0.5" 3.5" 7.75" AFW 200 3" 0.25" 6.0" 10.75" AFW 300 4" 1.0" 7.0" 11.75" AFW 400 1" 0.375" 1.5" 3.125" ASM 100 2" 0.375" 3.0" 4.625" ASM 200 3" 0.375" 6.0" 7.625" ASM 300 4" 0.375" 6.0" 7.625" ASM 400

Model Data
1" 0.0" 5.0" 2.0" HC 100

Ceiling Covers 3" 0.0" 9.0" 4.0" HC 300 4" 0.0" 10.0" 5.0" HC 400

2" 0.0" 6.0" 3.0" HC 200

A L LWAY M E TA L

EXPOSED SURFACE SPECIFY MODEL

Wall & Ceiling


CO V E R S 1" - 4 "
Duracell Headquarters, CT

Model Data
JOINT WIDTH

Corner Wall Covers 1" 0.63" 1.38" 2.37" AFWC 100 2" 1.25" 2.75" 4.25" AFWC 200 3" 1.5" 4.5" 6.25" AFWC 300 4" 2.5" 5.5" 7.25" AFWC 400 1" 0.5" 1.5" 1.875" ASMC 100 2" 0.5" 3.0" 3.375" ASMC 200 3" 0.5" 6.0" 6.375" ASMC 300 4" 0.5" 6.0" 6.375" ASMC 400

Model Data
1" 0.0" 5.0" 1.5" HCW 100

Corner Ceiling Covers 3" 0.0" 9.0" 3.5" HCW 300 4" 0.0" 10.0" 4.5" HCW 400

2" 0.0" 6.0" 2.5" HCW 200

MINIMUM OPENING MAXIMUM OPENING EXPOSED SURFACE SPECIFY MODEL

For odd and larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com

Wall Covers

Corner Wall Covers

Ceiling Covers

W Aluminum Anchor Clip ES W

AFW

ES Continuous Extruded Aluminum Cover Plate Continuous Extruded Aluminum Center Plate

ES

AFWC

HC

Dual Durometer PVC White Gasket

Use this cover for: Interior applications to match Allway metal floor covers. Standard aluminum covers supplied clear anodized, but Kynar paint and bronze or stainless top plates available. How it works: This wall covers free-floating aluminum center plate spans joint and slides between frame assemblies to allow movement when required. Cover can be painted to match wall finish.
Continuous Extruded Wall Joint Cover Snaps Into Retaining Clip For Simple Installation W Cover Edges Gasketed For Better Fit To Wall W Suspended Acoustical Ceiling (By Others)

W ES ES

ASM

ES 2" Wide Aluminum Anchor Clip

ASMC

HCW
Dual Durometer PVC White Gasket

28

For comprehensive information on these products, visit www.c-sgroup.com/expansion-joint-covers

29

Model Data Wall Covers


JOINT WIDTH MINIMUM OPENING MAXIMUM OPENING 2" 0.75" 3.0" 2.0" SF 200 3" 0.75" 4.5" 3.0" SF 300 4" 0.75" 6.0" 4.0" SF 400 5" 0.75" 7.5" 5.0" SF 500 6" 2.0" 9.0" 6.0" SF 600 7" 2.0" 10.5" 7.0" SF 700 8" 2.0" 12.0" 8.0" SF 800 9" 2.0" 13.5" 9.0" SF 900 10" 2.0" 15.0" 10.0" SF 1000 12" 6.0" 18.0" 12.0" SF 1200 14" 6.0" 21.0" 14.0" SF 1400 16" 6.0" 24.0" 16.0" SF 1600 1.0" .05" 1.5" 1.0" VF 100 2.0" 1.0" 3.0" 2.0" VF 200 3.0" 1.5" 4.5" 3.0" VF300 4.0" 2.0" 6.0" 4.0" VF 400 6.0" 3.0" 9.0" 6.0" VF 600 8.0" 4.0" 12.0" 8.0" VF 800

E X T E R I O R WA L L

EXPOSED SURFACE SPECIFY MODEL

Flexible Seals
2" - U P
Ohio State University, OH

Model Data Wall Covers


JOINT WIDTH MINIMUM OPENING MAXIMUM OPENING EXPOSED SURFACE SPECIFY MODEL 4" 0.75" 8.0" 4.0" SC 400 5" 0.75" 10.0" 5.0" SC 500 6" 2.0" 12.0" 6.0" SC 600 7" 2.0" 14.0" 7.0" SC 700 8" 2.0" 16.0" 8.0" SC 800 9" 2.0" 18.0" 9.0" SC 900 10" 2.0" 20.0" 10.0" SC 1000 11" 6.0" 22.0" 11.0" SC 1100 12" 6.0" 24.0" 12.0" SC 1200 13" 6.0" 26.0" 13.0" SC 1300 14" 6.0" 28.0" 14.0" SC 1400 15" 6.0" 30.0" 15.0" SC 1500 16" 6.0" 32.0" 16.0" SC 1600

For odd and larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com

Wall Covers
Continuous Extruded Secondary Seal W

Wall Covers

Wall Covers

ES

C/S Supplied Adhesive

SF-300

ES Continuous Extruded Aluminum Frame Continuous Extruded Santoprene Seal

SF-800
Turnbar

SF-200 (typical corner condition)

Use this cover for: Exterior vertical applications where weather protection is critical. Frames designed to attach to most external skin structures. 2" to 36" joint sizes with multi-directional movement. Factory welded transitions available. Four standard gasket colors (12 standard VF colors).
VF

Impregnated Compressible Foam Block W

Pantograph Load Support W

Continuous Extruded Aluminum Frame

ES Factory Applied Silicone Face

SC-400
Continuous Extruded Aluminum Frame

Continuous Extruded Santoprene Seal

SC-1200

ES Cont. Extruded Alum. Center Mullion

Model VF Colors
How it works: Flush, colorable seals for exterior applications, expand and compress during movement, while providing a weather tight seal.
Precast White Gray Limestone Sandstone

Gasket Colors
Black White Gray Greige

Natural Stone

Dusty Rose

Adobe Tan

Rustic Brick

Blue Spruce

Bronze

Charcoal

Black

Note: Custom colors available. Call 800-233-8493.

30

For comprehensive information on these products, visit www.c-sgroup.com/expansion-joint-covers

31

Model Data Wall Covers


JOINT WIDTH MINIMUM OPENING MAXIMUM OPENING 8" 4.0" 16.0" 17.31" XLS 800 10" 4.0" 20.0" 19.31" XLS 1000 12" 4.0" 24.0" 21.31" XLS 1200 14" 4.0" 28.0" 23.31" XLS 1400 16" 4.0" 32.0" 25.31" XLS 1600 4" 2.0" 8.0" 12.0" ESW 400 8" 2.0" 16.0" 18.0" ESW 800 12" 2.0" 23.0" 24.0" ESW 1200 16" 2.0" 29.0" 30.0" ESW 1600

SEISMIC

EXPOSED SURFACE SPECIFY MODEL

Exterior Wall
CO V E R S 4 " - U P
de Young Museum, CA

Model Data
JOINT WIDTH

Corner Wall Covers 8" 4.0" 16.0" 13.0" XLSC 800 10" 4.0" 20.0" 15.0" XLSC 1000 12" 4.0" 24.0" 17.0" XLSC 1200 14" 4.0" 28.0" 19.0" XLSC 1400 16" 4.0" 32.0" 21.0" XLSC 1600 4" 3.0" 7.5" 8.0" ESC 400 8" 5.0" 12.0" 13.0" ESC 800 12" 7.0" 17.5" 18.0" ESC 1200 16" 9.0" 22.5" 23.0" ESC 1600

MINIMUM OPENING MAXIMUM OPENING EXPOSED SURFACE SPECIFY MODEL

For odd and larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com

Cycling

Wall Covers

Extruded Aluminum Frame W

Moisture Seal

Turnbar

Vapor Barrier

Magnet

Strike Plate

XLS Contracted

Wall Panels Field Installed, and Supplied by Others

ES

ES Ladder System Accepts Wide Range of Mounting Systems and Panels

XLS

Wall Panels Field Installed, and Supplied by Others

ESW
SS Hinge

Aluminum Cover Plate

Wall Frame

Use this cover for: Exterior seismic wall applications where cover concealment is desired within curtain wall finishes. Lightweight finish applications up to 9/16" thick (supplied by others). Zero maintenance required after an earthquake. Where high wind loads are expected. How it works: Flush exterior wall cover releases from wall on one side to provide full seismic movement. Cover returns to closed position after an event via counterweight system.
Wall Panels Field Installed, and Supplied by Others Wall Substrate Control Assembly Frame Welded Aluminum Tube Frame W Hinge Frame

Moisture Seal

Turnbar W

Vapor Barrier

XLSC

ES Wall Panels Field Installed, and Supplied by Others S.S. Hinge

ESC

Aluminum Cover Plate

XLS Expanded

32

For comprehensive information on these products, visit www.c-sgroup.com/expansion-joint-covers

33

Model Data
JOINT WIDTH

Roof Covers 2" 1.0" 3.0" 10.0" BRJ 200 4" 1.0" 6.0" 12.0" BRJ 400 6" 1.0" 9.0" 14.0" BRJ 600 8" 1.0" 12.0" 16.0" BRJ 800 10" 0.0" 15.0" 18.0" BRJ 1000 12" 0.0" 18.0" 20.0" BRJ 1200 14" 0.0" 21.0" 22.0" BRJ 1400 16" 0.0" 24.0" 24.0" BRJ 1600 4" 0.5" 8.0" 12.0" SRJ 400 6" 0.5" 11.5" 15.0" SRJ 600 8" 0.5" 13.5" 18.0" SRJ 800 10" 0.5" 17.5" 21.0" SRJ 1000 12" 0.5" 20.5" 24.0" SRJ 1200 14" 0.5" 21.5" 27.0" SRJ 1400 16" 0.5" 25.0" 30.0" SRJ 1600

MINIMUM OPENING MAXIMUM OPENING EXPOSED SURFACE

Roof Covers
2" - U P
Round Valley Office Complex, NJ

SPECIFY MODEL

Model Data
JOINT WIDTH

Roof to Wall Covers 2" 1.0" 3.0" 6.0" BRJW 200 4" 1.0" 6.0" 8.0" BRJW 400 6" 1.0" 9.0" 10.0" BRJW 600 8" 1.0" 12.0" 12.0" BRJW 800 10" 1.0" 15.0" 14.0" 12" 0.0" 18.0" 16.0" 14" 0.0" 21.0" 18.0" 16" 0.0" 24.0" 20.0" 4" 2.5" 6.5" 8.0" 6" 3.5" 8.5" 10.5" SRJW 600 8" 4.5" 11.0" 13.0" SRJW 800 10" 5.5" 13.5" 15.5" 12" 6.5" 16.0" 18.0" 14" 7.5" 18.5" 20.5" 16" 8.5" 21.0" 23.0"

MINIMUM OPENING MAXIMUM OPENING EXPOSED SURFACE SPECIFY MODEL

BRJW 1000 BRJW 1200 BRJW 1400 BRJW 1600 SRJW 400

SRJW 1000 SRJW 1200 SRJW 1400 SRJW 1600

For odd and larger sized joints, call (800) 233-8493 or visit www.c-sgroup.com

Roof To Roof Covers

Roof To Wall Covers

Specialty Roof Joint Covers


High Movement and High Wind Loads

Furnace Bellows Closed Cell Foam Aluminum Retainer

Extruded Secondary Seal (Optional) Continuous Metal Retainer

Composite Design to Meet Project Wind Loads and Movement Criteria

BRJ

BRJW

Gyrometric Cover

Use this cover for: Applications in built-up, flat roofs. Joint sizes from 2" to 36" Multi-directional movement requirements. How it works: For metal roof covers, aluminum frames create a seal to the underside of sliding metal cover plates. For flexible roof joint covers, bellows material expands and contracts for multi-directional movement.

Moisture Seal Extruded Aluminum Frame Aluminum Cover Plate Turnbar Factory Fabricated End Transition Tucks Up Behind Vertical Seal Factory Fabricated Base Closure For Vertical Seal

Vapor Barrier

SRJ

SRJW

Parapet Transitions

34

For comprehensive information on these products, visit www.c-sgroup.com/expansion-joint-covers

35

Model Data
JOINT WIDTH

Floor to Floor Covers 4" 2.0" 6.0" 17.0" KB 400 6" 3.0" 9.0" 22.0" KB 600 8" 4.0" 12.0" 26.0" KB 800 6" 0.0" 11.0" 24.5" PTC 600 8" 0.0" 13.0" 26.5" PTC 800 10" 0.0" 16.0" 29.5" PTC 1000 12" 0.0" 19.0" 32.25" PTC 1200 14" 0.0" 22.0" 35.25" PTC 1400 16" 0.0" 25.0" 38.25" PTC 1600 4" 1.25" 5.25" 7.63"

Model Data
6" 1.25" 8.0" 11.13"

Floor to Wall Covers 8" 1.25" 10.25" 14.13" KBW800

MINIMUM OPENING MAXIMUM OPENING

PA R K I N G

EXPOSED SURFACE SPECIFY MODEL

Covers & Seals


1" - 16 "
Annapolis City Marina Parking, MD

KBW400

KBW600

Model Data
JOINT WIDTH

Floor to Floor Covers 2.0" 1.0" 3.0" 9.0" ZB200 3.0" 1.5" 4.5" 10.0" ZB300 4.0" 2.0" 6.0" 11.0" ZB400 1.0" 0.6" 1.5" 1.0" HB100 2.0" 1.13" 3.0" 2.0" HB200 3.0" 1.5" 4.5" 3.0" HB300 4.0" 2.0" 6.0" 4.0" HB400 .87" 0.43" 1.25" 0.87" HBF100 1.68" .87" 2.5" 1.68" HBF200 2.56" 1.37" 3.75" 2.56" HBF300 3.43" 1.81" 5.0" 3.43" HBF400

MINIMUM OPENING MAXIMUM OPENING EXPOSED SURFACE SPECIFY MODEL

For odd and larger sized joints, call (800) 233-8499 or visit www.c-sgroup.com

One-Piece EPDM Seal Bonded in an Epoxy Bed for Fast Installation ES

Sealant Neoprene Seal Elastomeric Concrete Installed with Epoxy Adhesive

Turnbar Housing Prevents Shearing of Bolts

Removable Vapor Barrier

ZB
Aluminum Top Cap (Stainless Steel Optional)

HBF
Hybrid Compression Seal Incorporating Built In Reservoirs for Epoxy Adhesive

KB
No Inflation Needed For Cast-In Place Applications

For Joint Sizes up to 9" with 50% Movement

Compression Seal

Vapor Barrier

Use this cover for: Seismic applications in parking and other areas with vehicular access. Available in standard or HS-20 heavy duty loading. New Cast-In-Place Model Available for post-tensioned slab applications. How it works: For a complete description call (800) 233-8493 and request a parking cover catalog or go to www.c-sgroup.com
PTC
W Extruded Aluminum Rotational Frame Vapor Barrier

PDA

Extruded Aluminum Side Frame

HB

KBC
Extruded Aluminum Frame Elastomeric Concrete Compression Spring Aluminum Cover Plate Leveling Grout (By Others)

36

For comprehensive information on these products, visit www.c-sgroup.com/expansion-joint-covers

37

N O M AT T E R W H AT J O I N T CO V E R YO U N E E D,

Weve got the right fire barrier.


C H O O S E T H E F I R E B A R R I E R T H AT B E S T S U I T S YO U R P R O J E C T.
UL Testing
All C/S Fire Barriers are tested rigorously at Underwriters Laboratories, including UL 2079 Cycling Tests.

Reflex 1"- 4"


Stainless steel foil drape with block insulation affords maximum economy in material and installation. Wall barriers limited to 1 - 4 joints and require no stainless foil.

When an expansion or seismic joint passes through a fire-rated structure it is necessary to maintain the fire integrity of that structure. Maintaining the integrity of a 2" wide joint is quite simple; however, a joint designed for seismic movement up to 24 inches becomes a more difficult proposition. In general, the wider the joint, the more complex the fire barrier. Most manufacturers use the same barrier design for all joint sizes. C/S has simplified our fire barrier for small joint sizes for easy installation and to maximize cost effectiveness (see Reflex). Floor applications are relatively simple configurations regardless of joint size unless lateral shear is required. Walls, on the other hand, can be more complex. All C/S fire barriers require only one barrier in the wall and require that the studs be

wrapped with drywall to maintain full integrity. (Includes shaft walls) Variations in wall configurations and finishes, as well as transitions between adjacent fire barriers, make it critical to consult the manufacturer concerning typical applications. C/S has a technical expert available to assist you in detailing these applications. Since 1996 building codes require fire barriers to limit the passing of heat and flame for 2, 3 and sometimes 4 hours, as well as accommodating the dynamic movement for which the joint was designed. ASTM E 1966 and UL 2079 specify criteria for cycling a fire barrier 500 times prior to fire testing. C/S tests all of its fire barriers at Underwriters Laboratories (UL) because they represent the most stringent and universally accepted testing authority.

NOMINAL JOINT WIDTH 1 2 3 4

C/S MODEL FLOORS RFX-1F RFX-1X RFX-2F RFX-2F RFX-3F RFX-4F

C/S UL NUMBER FLOOR FF-D-0044 FF-D-0044 FF-D-0045 FF-D-0045 FF-D-1055 FF-D-1065

C/S MODEL GYPSUM WALL RFX-1W (GYP.) RFX-1W (1 HR GYP.) RFX-2W (GYP.) RFX-2W (1 HR GYP.)

C/S UL NUMBER GYPSUM WALL WW-D-0048 WW-D-0059 WW-D-0049 WW-D-0061

C/S MODEL MASONRY WALL RFX-1W(CONC) RFX-1W(1 HR CONC.) RFX-2W(CONC) RFX-2W(1 HR CONC.)

C/S UL NUMBER MASONRY WALL WW-D-0050 WW-D-0060 WW-D-0051 WW-D-0062

FOR WALL APPLICATIONS OVER 2" PLEASE SEE MULTIFLEX OFFERING

Multiflex 3"-12"
Sandwich assembly of layers of stainless steel foil and insulation contained in a stainless steel mesh. Standard barrier allows up to 50% lateral shear in floor applications.
NOMINAL JOINT WIDTH 3-6 7-12 C/S MODEL FLOORS MFX-3F-6F MFX-7F-12F C/S UL NUMBER FLOOR FF-D-1066 FF-D-2009 C/S MODEL GYPSUM WALL MFX-3W-6W(GYP) MFX-7W-12W(GYP) C/S UL NUMBER GYPSUM WALL WW-D-1056 WW-D-2011 C/S MODEL MASONRY WALL MFX-3W-6W(CONC) MFX-7W-12W(CONC) C/S UL NUMBER MASONRY WALL WW-D-1057 WW-D-2012

FB97 13"-Up
Multiple drape configurations of stainless foil and insulation utilizing air pockets for additional insulation performance. Sliding frame available for 100% lateral shear applications in floors.
NOMINAL JOINT WIDTH 13-24 25-36 13-24 25-36 C/S MODEL FLOORS FB97-13-24 FB97-25-36 FB97-13(LS)-24(LS) FB97-25(LS)-36(LS) C/S UL NUMBER FLOOR FF-D-3005 FF-D-4001 FF-D-3006 FF-D-4002 C/S MODEL GYPSUM WALL FB97-13-24(GYP) NA NA NA C/S UL NUMBER GYPSUM WALL WW-D-3007 NA NA NA C/S MODEL MASONRY WALL FB97-13-24(CONC) NA NA NA C/S UL NUMBER MASONRY WALL WW-D-3008 NA NA NA

LS designation indicates a special adaptation of the floor fire barrier to accommodate Lateral Shear movement. FB-97 wall fire barriers naturally provide lateral shear movement.

6696 State Route 405, Muncy, Pennsylvania 17756 U.S.A., 570-546-5941 895 Lakefront Promenade, Mississauga, Ontario L5E 2C2 Canada, 905-274-3611

www.c-sgroup.com

The C/S Family of Products For more than 60 years, Construction Specialties has been a leader in architectural specialty products, including: Acrovyn Wall and Door Protection, Pedisystems Entrance Flooring, Expansion Joint Covers, Cubicle Track and Curtains, Smoke and Explosion Venting Systems, Architectural Grilles, Architectural Louvers and Sun Controls.

We have operations throughout the world and can provide C/S Products virtually anywhere. For a complete list of our international locations, visit www.c-sgroup.com.

For the nearest C/S representative, or literature and samples, call toll free 800-233-8493 in U.S.A. and 888-895-8955 in Canada, or visit www.c-sgroup.com
Copyright 2009 Construction Specialties, Inc. Construction Specialties, Inc. reserves the right to make design changes or to withdraw any design without notice. Printed in U.S.A. Series 10

S-ar putea să vă placă și