AIRFIELD LIGHTING PRIMARY CABLE

TSXB7Pe 5 kV Type C In compliance to FAA Specification for L-824, AC 150/5345-7D

Construction : 1. Round Stranded Tinned Copper Conductor 2. Extruded Semiconductive Shield ( conductor shield ) 3. Extruded XLPE Insulation 4. Semiconductive Shield ( Insulation shield ) 5. Brass Tape Shield 6. Polyester Tape 7. Extruded PE Anti Termite Outer Sheath/Jacket ( Black Color ) *. Other color of Jacket is available

Item Code

Nominal Max. Approx. Approx. Conducto Nominal thickness No. of core conductor Overall weight of r number Insulation of Brass and size resistance diameter cable of wire thickness tape at 20 C mm 2.3 mm 0.1 mm 11.4 kg/km 189 /km 3.11

Rated Min. Insulation Ampere resistance at 40 C at 20 C in ground M.Ohm.km Ampere 3,200 86

DTSXB7P0001065MC

1 x 6 mm

TSXC7Pe/PVC 5 kV Type C In compliance to FAA Specification for L824, AC 150/5345-7D

Construction : 1. Round Stranded Tinned Copper Conductor 2. Extruded Semiconductive Shield ( conductor shield ) 3. Extruded XLPE Insulation 4. Semiconductive Shield ( Insulation shield ) 5. Copper Tape Shield 6. Polyester Tape 7. Extruded PVC Anti Termite Outer Sheath/Jacket ( Black Color ) *. Other color of Jacket is available

Item Code

Nominal Max. Approx. Approx. Conducto Nominal thickness No. of core conductor Overall weight of r number Insulation of Brass and size resistance diameter cable of wire thickness tape at 20 C 1 x 6 mm 7 mm 2.3 mm 0.1 mm 11.4 kg/km 193 /km 3.11

Rated Min. Insulation Ampere resistance at 40 C at 20 C in ground M.Ohm.km Ampere 3,200 86

DTSXC7PPVC1065MC

AIRFIELD LIGHTING PRIMARY CABLE


TSXB7E 5 kV Type C In compliance to FAA Specification for L824, AC 150/5345-7D

Construction : 1. Round Stranded Tinned Copper Conductor 2. Extruded Semiconductive Shield ( conductor shield ) 3. Extruded XLPE Insulation 4. Semiconductive Shield ( Insulation shield ) 5. Brass Tape Shield 6. Polyester Tape 7. Extruded PE Anti Termite Outer Sheath/Jacket ( Black Color ) *. Other color of Jacket is available

Item Code

Nominal Max. Approx. Approx. Conducto Nominal thickness No. of core conductor Overall weight of r number Insulation of Brass and size resistance diameter cable of wire thickness tape at 20 C 1 x AWG 8 7 mm 2.3 mm 0.1 mm 11.5 kg/km 213 /km 2.011

Rated Min. Insulation Ampere resistance at 40 C at 20 C in ground M.Ohm.km Ampere 3,100 92

DTSXB7E0001085MC

TSXC7E 5 kV Type C In compliance to FAA Specification for L-824, AC 150/5345-7D

Construction : 1. Round Stranded Tinned Copper Conductor 2. Extruded Semiconductive Shield ( conductor shield ) 3. Extruded XLPE Insulation 4. Semiconductive Shield ( Insulation shield ) 5. Copper Tape Shield 6. Polyester Tape 7. Extruded PE Anti Termite Outer Sheath/Jacket ( Black Color ) *. Other color of Jacket is available

Item Code

Nominal Max. Approx. Approx. Conducto Nominal thickness No. of core conductor Overall weight of r number Insulation of Brass and size resistance diameter cable of wire thickness tape at 20 C 1 x AWG 8 7 mm 2.3 mm 0.1 mm 11.5 kg/km 215 /km 2.011

Rated Min. Insulation Ampere resistance at 40 C at 20 C in ground M.Ohm.km Ampere 3,100 92

DTSXC7E0001085MC

AIRFIELD LIGHTING PRIMARY CABLE

PCU/PE/PVC 3 kV In compliance to BS 6234, BS 6360, BS 6007, BS 6746, M&E 42

Construction : 1. Round Stranded Copper Conductor 2. Extruded PE Insulation 3. Extruded PVC Outer Sheath/Jacket *. Other color of Jacket is available

Item Code

Max. Conducto Nominal Nominal Approx. Approx. No. of core conductor r number Insulation thickness Overall weight of and size resistance of wire thickness of Sheath diameter cable at 20 C 7 mm 2.8 mm 1.2 mm 11.1 kg/km 164 /km 3.08

Rated Min. Insulation Ampere resistance at 40 C at 20 C in ground M.Ohm.km Ampere 4,000 72

DPCUPEPVC01063MC 1 x 6 mm

AIRFIELD LIGHTING PRIMARY CABLE

TCU/EPR/PE 5 kV
In compliance to BS 6234, BS 6360, BS 6007, BS 6746, M&E 42

Construction : 1. Round Stranded Tinned Copper Conductor 2. Extruded EPR Insulation 3. Extruded PE Outer Sheath/Jacket *. Other color of Jacket is available

Item Code

Max. Conducto Nominal Nominal Approx. Approx. No. of core conductor r number Insulation thickness Overall weight of and size resistance of wire thickness of Sheath diameter cable at 20 C 7 mm 2.8 mm 1.2 mm 11.1 kg/km 188 /km 3.11

Rated Min. Insulation Ampere resistance at 40 C at 20 C in ground M.Ohm.km Ampere 600 72

DTCUEPRPE01065MC 1 x 6 mm

TCU/EPR/PCP 5 kV In compliance to FAA Specification for L-824, AC 150/5345-7D

Construction : 1. Round Stranded Tinned Copper Conductor 2. Extruded EPR Insulation 3. Extruded Polycloroprene Sheath *. Other color of Jacket is available

Item Code

Max. Conducto Nominal Nominal Approx. Approx. No. of core conductor r number Insulation thickness Overall weight of and size resistance of wire thickness of Sheath diameter cable at 20 C 7 7 19 mm 2.3 2.3 2.3 mm 1.2 1.2 1.2 mm 10.1 10.9 11.0 kg/km 128 166 167 /km 3.11 2.011 2.011

Rated Min. Insulation Ampere resistance at 40 C at 20 C in ground M.Ohm.km Ampere 600 72 400 92 400 92

DTCUEPRPCP1065MC 1 x 6 mm DTCUEPRPCP1085MC 1 x AWG 8 DTCUEPRPCP1185MC 1 x AWG 8

AIRFIELD LIGHTING PRIMARY CABLE

FL2XCY 6 kV Type C In compliance to FAA Specification for L824, AC 150/5345-7D

Construction : 1. Round Stranded Copper Conductor 2. Extruded Semiconductive Shield ( conductor shield ) 3. Extruded XLPE Insulation 4. Semiconductive Shield ( Insulation shield ) 5. Copper Wire Shield 6. Polyester Tape 7. Extruded PVC Anti Termite Outer Sheath/Jacket ( Red Color ) *. Other color of Jacket is available

Item Code

Conducto Nominal No. of core r number Insulation and size of wire thickness mm 2.5

Dia of copper wire screen mm 0.5

Max. Approx. Approx. conductor Overall weight of resistance diameter cable at 20 C mm 15.2 kg/km 298 /km 3.08

Rated Min. Insulation Ampere resistance at 40 C at 20 C in ground M.Ohm.km Ampere 3,200 86

DFL2XCY0010666MC 1 x 6/6 mm

FLYCY 6 kV Type C In compliance to FAA Specification for L-824, AC 150/5345-7D

Construction : 1. Round Stranded Copper Conductor 2. Extruded Semiconductive Shield ( conductor shield ) 3. Extruded PVC Insulation 4. Semiconductive Shield ( Insulation shield ) 5. Copper Wire Shield 6. Polyester Tape 7. Extruded PVC Anti Termite Outer Sheath/Jacket ( Black Color ) *. Other color of Jacket is available

Item Code

Conducto Nominal No. of core r number Insulation and size of wire thickness mm 2.5

Dia of copper wire screen mm 0.5

Max. Approx. Approx. conductor Overall weight of resistance diameter cable at 20 C mm 15.2 kg/km 325 /km 3.08

Rated Min. Insulation Ampere resistance at 40 C at 20 C in ground M.Ohm.km Ampere 60 62

DFLYCY00010666MC 1 x 6/6 mm

AIRFIELD LIGHTING SECONDARY CABLE


SRN 600 V Type A In compliance to FAA Specification, AC 150/5345-7D ( L-824)

Construction : 1. Round Bunhed Tinned Copper Conductor 2. Extruded Rubber Insulation 3. Extruded Polychloroprene Outer Sheath/Jacket *. Other color of Jacket is available

Item Code

Max. Nominal Nominal Approx. Approx. No. of core Max. dia conductor Insulation thickness Overall weight of and size of wire resistance thickness of Sheath diameter cable at 20 C 0.26 0.31 mm 0.9 1.0 mm 2.0 2.0 mm 11.8 13.0 kg/km 173 223 /km 8.21 5.09

Rated Min. Insulation Ampere resistance at 40 C at 20 C in ground M.Ohm.km Ampere 800 32 700 44

DSRN0000002205FC 2 x 2,5 mm DSRN0000002004FC 2 x 4 mm

PVC/Nylon 600 V In compliance to FAA Specification for L846, AC 150/5345

Construction : 1. Round Stranded Copper Conductor 2. Extruded PVC Insulation (85 o C) 3. Extruded Nylon Outer Sheath/Jacket, Melting point 185o C *. Other color of Jacket is available

Item Code

Max. Conducto Nominal Nominal Approx. Approx. No. of core conductor r number Insulation thickness Overall weight of and size resistance of wire thickness of Sheath diameter cable at 20 C 7 mm 0.51 mm 0.3 mm 4.2 kg/km 51 /km 4.61

Rated Min. Insulation Ampere resistance at 40 C at 20 C in ground M.Ohm.km Ampere 30 47

DPVCNYLON01004MC 1 x 4 mm