Analog/ISDN/GeoCENTREX
Calling Line Identication Restriction (CLIR)
Availability
Analog Subscriber GeoCENTREX subscriber X X ISDN X X
Benefits ... for the operator complementary function to the feature Calling Line Identication Presentation (CLIP) with additional marketing possibilities ... for the subscriber the calling subscriber remains anonymous
Mode of operation
The feature Calling Line Identification Restriction (CLIR) prevents call data from being displayed to the called subscriber. The feature can be activated by the operator or the subscriber and remains active until it is deactivated. The following functions can be used to influence the display of call data to the called subscriber: CLIRREQ - to suppress the calling subscribers call data on request (CLIR on request), for the next call only CLIRSUSP - to suspend the suppression of the calling subscribers call data for the next call (CLIR suspension)
Interactions For interaction with other features, see Feature Interactions. Standards The feature is based on the following standards: ETS 300 093
Network node
or
CLIR active
The CLIR information is transferred from the originating network node to the destination network node during call setup. Signaling with SS7 TUP or ISUP is possible. The destination network node then suppresses the display of the calling subscribers call data to the called subscriber. Capacity The percentages indicate the number of authorized subscribers for the feature within the network node and their simultaneous application.
Analog Authorization Subscriber GeoCENTREX subscriber 10% 10% Use ISDN Authorization 10% 10% Use
Signaling method Analog Pulse DTMF Keypad X X ----------X X ----ISDN Functional protocol --------------X -------
Activate Deactivate Enter data Delete data Enter data and activate Delete data and deactivate Activate with/without data Feature use Status request Data request Status request with/without data
X X ----------X X -----
X X ----------X X -----
100% 100%
100% 100%
Explanation of the input procedures The meaning of the pictograms and abbreviations is explained in the overview in the section on subscriber controlled input, as well as the differences in the procedure for pulse dialing. Activate DT (( ) IND Deactivate DT (( ) IND Interrogate state DT (( ) IND Feature use Analog CLIRREQ/CLIRSUSP for the next connection DT SC DN-B A-B Start Directory number Connection PIN) SC optional SC PIN) optional SC PIN) optional
An ISDN subscriber can also request one-off usage of CLIR by setting the display indicator of the calling subscribers directory number to restricted. In the case of the feature option CLIRSUSP the calling ISDN subscriber can suspend the CLIR function for the next call, thus permitting the display of the call data to the called subscriber. For one-off suspension of CLIR per call (CLIRSUSP, in case of ISDN), the display indicator for the called subscribers directory number is set to allowed. In this case, the calling subscribers directory number is displayed if the called subscriber has authorization for the feature CLIP. Otherwise, the display indicator for the calling subscribers directory number is set to restricted. Additional possibilities for feature control
Feature Automatic Feature Subscription (AFS) Remote Subscriber Controlled Input (RSCI) Feature Control Offline (FCOFF) General Facility Reset (GFR) Use ----X X
ISDN Keypad protocol CLIRSUSP for the next connection DT SC DN-B A-B Start Directory number Connection
Assign authorization Remove authorization Assign authorization to modify Remove authorization to modify Status request, data request Use
ISDN Function protocol FK IND DN-B A-B FK CLIR-REQ/SUSP Directory number Connection
Administration
The operator can perform all administration functions on the NetManager by means of user-friendly applications or MML commands. Feature authorization The network operator assigns authorization for the feature when requested by the subscriber. Subscriber access types The feature can be used with the following types of subscriber access:
Type Subscriber Analog Main station Basic access PBX PBX with BA and/or PA PBX line PBX line with Direct Dialing In (DDI) PBX line, connected like a subscriber Coinbox Emergency call station MLHG line Basic attendant console MAC attendant console X --X ----X ------------ISDN --X --X ----------------GeoCENTREX Analog X --X ----X ------------ISDN --X --X -----------------
Call charge registration For more information, please refer to OMN:EXCH-TA. System administration The following feature data can be administrated in the network node: options for subscriber controlled input display and modication of network node options creation of announcements recording by means of trafc measurement For more information, please refer to OMN:EXCH-SY. Routing administration For more information, please refer to OMN:EXCH-RO. Subscriber administration For more information, please refer to OMN:EXCH-SU. GeoCENTREX administration For more information, please refer to OMN:EXCH-CTX.
Requirements
Hardware UI-LTG with OCANEQ speech equipment and INDAS for: acknowledging subscriber controlled input Signaling Signaling between the network nodes Signaling system no. 7 (SS7) ISDN user part (ISUP) Telephony user part (TUP) Subscriber signaling Analog Dual-tone multi-frequency (DTMF) Pulse dialing ISDN Digital subscriber signaling system no.1 (DSS1) Subscriber interfaces The following interfaces for subscriber access are required: DLU LTG V5.1 interface V5.2 interface
ISDN basic service The allocation and usage of the feature are service specific. The basic code may be different, depending on the individual project.
Basis service Circuit mode: speech Circuit mode: 64 kbit/s unrestricted Circuit mode: 3.1 kHz audio Basis code 01 02 03
Copyright (C) Siemens AG 2002 Issued by Information and Communications Group Hofmannstrae 51 D-81359 Mnchen Technical modifications possible. Technical specifications and features are binding only insofar as they are specifically and expressly agreed upon in a written contract. Order Number: A30828-X1160-B632-1-7629 Visit our Website at: http://www.siemens.com