In order to offer a range of small tendons with flat anchorages especially adapted for the post-tensioning of buildings or thin elements (slabs, floors), Freyssinet developed the system B prestressing anchorages. The system B is suitable for traditional internal post-tensioning using tendons made up of high-strength steel strands, in accordance with NFA 35-045 or pr EN 10138 or other relevant standards, with the characteristics mentioned below: Diameter Type 12.7 12.9 15.2 15.7 T13 T13S T15 T15S Designation Standard strand Super strand Standard strand Super strand Fm max 183.7 kN 186 kN 260 kN 279 kN
ANCHORAGE dimENSiONS
The strands are anchored individually, in cylindrical-conical holes in the anchorages, by conical wedges composed of three parts (Freyssinet Unigrip wedges).
5B15 anchorage with sheath A distinction is made between two family units, depending on the prestressing application: Bonded post-tensioning units (most current), composed of bare strands protected by a flat sheath, usually made of smooth or corrugated steel or high density polyethylene (HDPE) pipe injected with cement grout bonding the concrete structure and protecting the tensioned strands. Unbonded post-tensioning units made up of unbonded strands. The strands are individually protected by grease and a HDPE sheath, so that the strand is free to slide inside the sheath without being bonded to the structure. Both families use tendons composed of 3, 4 or 5 strands.
Freyssinet - 1 bis rue du Petit-Clamart - 78140 Vlizy-Villacoublay - Tel : +33 (0)1 46 01 84 84 - Fax : +33 (0)1 46 01 85 85 - www.freyssinet.com
pERFORmANCES
Approval static tests according to BS 4447 have been carried out on the anchorages of the B range. They can be used with all classes of standard or super strands (T13, T13S, T15, T15S), in concrete structures. B range anchorages can be used on slabs with a minimal thickness of 180 mm. The minimal concrete compressive strength at stressing shall be the following depending on the strand type : Strand type T13 S T15 T15 S Minimal cylinder concrete compressive strength 20 MPa 21 MPa 23 MPa Minimal cube concrete compressive strength 25 MPa 26 MPa 28 MPa
BURSTiNG REiNFORCEmENT
The recommended bursting reinforcement is described in the sketch below.
mANUFACTURiNG
PPC ZA du Monay - BP 18 - Saint Eusbe 71210 MONTCHANIN - France Tel.: + 33 (0) 3 85 73 69 00 Fax: + 33 (0) 3 85 73 69 01 Sales manager: Bernard CADOT or Bruno ZACCARO Tel.: + 33 (0) 3 85 73 69 49 / + 33 (0) 3 85 73 69 43 bernard.cadot@freyssinet.com / bruno.zaccaro@freyssinet.com Technical contact: Nicolas DEMEY Tel. + 33 (0) 1 46 01 85 15 nicolas.demey@freyssinet.com