Motor starters up to 65 A TeSys Play your own combination!

TeSys motor starters up to 65 A

Save space
45 and 55 mm widths Compact DC contactor S-shape and multiple tap-off busbar systems

Smaller

With a width of 45 mm up to 38 A and 55 mm up to 65 A, TeSys motor starters fit more easily into electrical enclosures.

Install without wiring

Special busbar systems allow fast pre-wiring of power connections. Assemble a motor starter on a single rail with the S shape busbar system.

Increase automation
Direct Control Quickfit pre-wired control technology

Control and save

Control TeSys low consumption contactor from your PLC outputs.

Pre-wire and communicate

The TeSys Quickfit pre-wired solution allows communication with PLCs via Advantys STB interface or a splitter box.

Save time
Spring terminals and Reverser kit Common accessories range

Combine without wiring

Simple manual unclipping of a terminal block allows you to combine the circuit-breaker with the contactor. Assembling a reverser becomes childs play. Using standard contactors, you can build your reversing starter in less than 2 minutes on the clock, without any risk of wiring errors. Flexibility using add-on blocks and accessories, that are common throughout the 9 to 65A motor starters range.

Increase reliability and safety


Auxiliary safety contacts Spring terminals and Type 2 tested motor starters

Increase safety

Mechanically linked auxiliary and mirror contacts ensure reliable return of information and allow you to include TeSys contactors in your safety applications.

Increase reliability

Spring terminals and Schneider Electrics new, patented terminal block technology ensure permanent tightening quality by compensating for cable creep.

Guarantee performance

Continuity of service is guaranteed by using tested combinations with high breaking capacity. Type 2 coordination allows operation to be resumed more quickly after a short-circuit fault.

TeSys motor starters selection guide

TeSys GV2 + LC1D


High breaking capacity / Icu/400v Setting range of thermal trips Thermal-magnetic circuit-breaker Standard breaking capacity / Icu/400v Setting range of thermal trips Thermal-magnetic circuit-breaker Ie AC-3 (A) Ie AC1 (T<60C) (A) Contactor 130KA GV2P02 130KA GV2ME02 0.2 25 LC1D09

Circuit breaker + contactor


130KA GV2P03 130KA GV2ME03 0.3 25 LC1D09 130KA GV2P04 130KA GV2ME04 0.44...0.6 25 LC1D09 130KA GV2P05 130KA GV2ME05 0.85 25 LC1D09 130KA 11.6 A GV2P06 130KA 11.6 A GV2ME06 1.1...1.5 25 LC1D09 130KA 1.62.5 A GV2P07 130KA 1.62.5 A GV2ME07 1.9 25 LC1D09 130KA 2.5...4 A GV2P08 130KA 2.5...4 A GV2ME08 2.7...3.6 25 LC1D09

0.160.25 A 0.250.40 A 0.400.63 A 0.631 A

0.160.25 A 0.250.40 A 0.400.63 A 0.631 A

Connection : GV2P, GV2ME, LC1D up to 32 A : by screw clamp terminal (for power and control spring terminal, add 3 at the end of

Standard power ratings of 3-phase motors 50-60 Hz in category AC3/400V (kw)

0.06

0.09

0.12...0.18

0.25

0.37...0.55

0.75

1.1...1.5

TeSys GV2 + LC1D + LRD


High breaking capacity / Icu/400v Magnetic circuit-breaker Standard breaking capacity / Icu/400v Magnetic circuit-breaker Ie AC3 (A) Ie AC1 (T<60C) (A) Contactor Setting range Thermal overload relay cl10A Setting range Thermal overload relay cl10A Setting range Thermal overload relay cl20 Setting range Thermal overload relay cl20 130KA GV2L02 130KA GV2LE02 0.2 25 LC1D09 130KA GV2L03 130KA GV2LE03 0.3 25 LC1D09

Circuit breaker + contactor + thermal relay


130KA GV2L04 130KA GV2LE04 0.44...0.6 25 LC1D09 130KA GV2L05 130KA GV2LE05 0.85 25 LC1D09 130KA GV2L06 130KA GV2LE06 1.1...1.5 25 LC1D09 11.7 A LRD06 130KA GV2L07 130KA GV2LE07 1.9 25 LC1D09 1.62.5 A LRD07 130KA GV2L08 130KA GV2LE08 2.7...3.6 25 LC1D09 2.5...4 A LRD08 2.5...4 A LRD1508 -

0.160.25 A 0.250.40 A 0.400.63 A 0.631 A LRD02 LRD03 LRD04 LRD05 -

Connection : GV2L, GV2LE, LC1D & LRD up to 32 A : by screw clamp terminal (for power and control spring terminal, add 3 at the end of the reference

Coil voltage Contactor AC Standard DC 5,4 W BD ED SD FD MD Low consumption DC * < 2,4 W BL EL SL

24 V 48 V 72 V 110 V 120 V 220 V 230 V 240 V 380 V 400 V 415 V 440 V

50/60 HZ B7 E7 F7 G7 M7 P7 U7 Q7 V7 N7 R7

* Only for LC1D40 to D65, please order LAD4DBL accessory for direct control from a PLC.

TeSys GV3 + LC1D


130KA 4...6.3 A GV2P10 130KA 4...6.3 A GV2ME10 4.9 25 LC1D09 130KA 6...10 A GV2P14 130KA 6...10 A GV2ME14 6.5 25 LC1D09 130KA 6...10 A GV2P14 130KA 6...10 A GV2ME14 8.5 25 LC1D09 130KA 9...14 A GV2P16 15KA 9...14 A GV2ME16 11.5 25 LC1D12 100KA 12...18 A GV3P18 15KA 13...18 A GV2ME20 15.5 32 LC1D18 100KA 12...18 A GV3P25 15KA 17...23 A GV2ME21 18.1 40 LC1D25 100KA 17...25 A GV3P25 15KA 20...25 A GV2ME22 22 40 LC1D25 100KA 23...32 A GV3P32 15KA 24...32 A GV2ME32 29 50 LC1D32 50KA 30...40 A GV3P40 50KA 30...40 A GV3P40 35 60 LC1D40A 50KA 37...50 A GV3P50 50KA 37...50 A GV3P50 41 80 LC1D50A 50KA 48...65 A GV3P65 50KA 48...65 A GV3P65 55 80 LC1D65A

the reference selected). GV3P, LC1D40 to D65 : by EverLink terminal (for control spring terminal, add 3 at the end of the reference selected). Connection by lugs add the digit 6 at the end of the reference selected

2.2

5.5

7.5

11

15

18.5

22

30

TeSys GV3 + LC1D + LRD3


130KA GV2L10 130KA GV2LE10 4.9 25 LC1D09 4...6 A LRD10 4...6 A LRD1510 130KA GV2L14 130KA GV2LE14 6.5 25 LC1D09 5.5...8 A LRD12 5.5...8 A LRD1512 130KA GV2L14 130KA GV2LE14 8.5 25 LC1D09 7...10 A LRD14 7...10 A LRD1514 50KA GV2L16 15KA GV2LE16 11.5 25 LC1D12 9...13 A LRD16 9...13 A LRD1516 50KA GV2L20 15KA GV2LE20 15.5 32 LC1D18 12...18 A LRD21 12...18 A LRD1521 50KA GV2L22 15KA GV2LE22 18.1 40 LC1D25 16...24 A LRD22 17...25 A LRD1522 100KA GV3L25 15KA GV2LE22 22 40 LC1D25 16...24 A LRD22 17...25 A LRD325 17...25 A LRD1522 17...25 A LRD325L 100KA GV3L32 15KA GV2LE32 29 50 LC1D32 23...32 A LRD32 23..32 A LRD332 25...32 A LRD1532 23...32 A LRD332L 50KA GV3L40 50KA GV3L40 35 60 LC1D40A 30...40 A LRD340 30...40 A LRD340L 50KA GV3L50 50KA GV3L50 41 80 LC1D50A 37...50 A LRD350 37...50 A LRD350L 50KA GV3L65 50KA GV3L65 55 80 LC1D65A 48...65 A LRD365 48...65 A LRD365L

selected). GV3L, LC1D & LRD3 : by EverLink terminal (for control spring terminal, add 3 at the end of the reference selected). Connection by lugs add the digit 6 at the end of the reference selected

Add-on blocks common to TeSys GV2-GV3 circuit-breakers


CONTACT BLOCK Instantaneous auxiliary contacts Mounting position Left-hand side Front "F" or "O" GVAE1 "F" and "O" GVAN11 (1) GVAE11
(1)

"F" + "F" GVAN20 (1) GVAE20 (1)

(1) For spring terminal version, add 3 to the end of the reference, example: GVAN11 becomes GVAN113

Fault contact + instantaneous auxiliary contact Mounting position Left-hand side Front GV3 only

"F" (fault) + "O" GVAD1001 GVAED011 (2)

"F" (fault) + "F" GVAD1010 GVAED101 (2)

"O" (fault) + "O" GVAD0101

"O" (fault) + "F" GVAD0110

(2) For spring terminal version, add 3 to the end of the reference, example: GVAED011 becomes GVAED0113 (GV3 only)

Short-circuit signalling contact Mounting position Left-hand side

"OF" with common point GVAM11

Accessories for TeSys GV2-GV3 circuit-breakers


SETS OF 3-POLE 63 A BUSBARS Number of combined GV2 circuit-breakers Bar pitch (1) 45 mm 54 mm 72 mm SETS OF 3-POLE 115 A BUSBARS Number of combined GV3 circuit-breakers Bar pitch TERMINAL BLOCKS For supply to one or more busbar sets Connection from the top "Large spacing" terminal block UL508 GV2ME/P/L GV1G09 GV2P..H7 GV2GH7 PADLOCKING DEVICE For 4 padlocks GV2ME/P/L-GV3P/L PADLOCKABLE EXTERNAL OPERATOR Colour of operator GV2P/L GV2LE GV3P/L Padlocking Padlocking Padlocking Black handle/blue legend plate In ON and OFF positions GV2AP01 In ON and OFF positions GV2AP03 In ON and OFF positions GV3AP01 In OFF position GV3AP02 Red handle/yellow legend plate In OFF position GV2AP02 Shank diameter 6 mm max., padlocks not supplied GV2V03 GV3P/L GV3P GV3G66 64 mm 2 GV3G264 3 GV3G364 2 GV2G245 GV2G254 GV2G272 3 GV2G345 GV2G354 4 GV2G445 GV2G454 GV2G472 5 GV2G554 -

(1) Protective end cover for unused busbar outlets, reference: GV1G10

Add-on blocks for TeSys LC1D contactors


CONTACT BLOCK Instantaneous auxiliary contacts Mounting position Front Side Time delay auxiliary contacts Mounting position Front On-delay Off-delay 1F LADN10 0.1...3 s LADT0 LADR0 10 LADN01 0.1...30 s LADT2 LADR2 1F + 10 LADN11 LAD8N11 10...180 s LADT4 LADR4 2F LADN20 LAD8N20 20 LADN02 LAD8N02 2F + 20 LADN22 -

LC1D
1F + 30 LADN13 3F + 10 LADN31 -

TeSys motor starter mounting accessories


COMBINATION MOUNTING < 38 A (with GV2 range) GV2AF3 (on mounting rail) GV2AF4 (on mounting plate LAD311)
(1) GV3P/L can be ordered without outgoing terminal block. Ex : GV3P651

< 65 A (with GV3 range) Without accessory (1)

SIDE-BY-SIDE MOUNTING S-SHAPE BUSBAR SYSTEM < 38 A (with GV2 range) < 65 A (with GV3 range) GV3S (2)
(2) Can be associated with a combination reverser assembly

COMBINATION REVERSER ASSEMBLY REVERSER KIT (3) < 38 A LAD9R1V


(3) Can be associated with a side-by-side assembly

from 40 to 65 A LAD9R3

SEPARATE RELAY MOUNTING TERMINAL BLOCK < 38 A (for LRD) LAD7B106 < 65 A (for LRD3) LAD96560

2 4

1 3

MOUNTING WITH PRE-WIRED CONTROL TECHNOLOGY TESYS QUICKFIT MOUNTING KIT (for LC1D..3 contactor with spring terminals) Motor connection module - Direct Without relay LAD9AP3D1 Motor connection module - Reverser Without relay LAD9AP3D2 Parallel wiring module Advantys STB 4xRJ45 STBEPI2145
3 2 1

Electronic relay (for DC coil control) LAD9AP31 Electronic relay (for DC coil control) LAD9AP32 Splitter block LU9G02
4

2xHE10 / 8xRJ45

www.schneider-electric.com

Schneider Electric Industries S.A.S.


DIA1ED1070901EN 01/ 2008 Head office 89 boulevard Franklin Roosevelt 92504 Rueil-Malmaison Cedex France Owing to changes in standards and equipment, the characteristics given in the text and images in this document are not binding until they have been confirmed by us. Design/Production: JAPA Printed by: http://www.schneider-electric.com Photos: Schneider Electric

ART. 831641